Georgiy Ts. Dambaev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Georgiy Ts. Dambaev has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Г. Ц. Дамбаев
Сибирский государственный медицинский университет
5 shared publications- M. M. Soloviev
Siberian State Medical University
4 shared publications - Oleg V. Kokorev
Siberian State Medical University
4 shared publications - Viktor Eduardovich Gunther
National Research Tomsk State University
4 shared publications - Dmitrii Vladimirovich Vasilchenko
Siberian State Medical University
3 shared publications - N. E. Kurtseitov
Siberian State Medical University
3 shared publications
Latest Publications
- Open Access
- 28 October 2025
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 28 (3) , 97-106
Prospective testing of the effectiveness and safety of using a medical device “Wound coating based on the NovoSkin collagen-laminate matrix”
The study examines the effectiveness and safety of the medical device “Wound coating based on the NovoSkin collagen-laminate matrix”, conducted from February to May 2024 at the Ryazan State Medical University (Ryazan, Russia). Purpose of a study: to evaluate the use of wound coating NovoSkin in patients with skin defects. Materials and methods. NovoSkin is a sterile, round-shaped coating with a uniform matte and transparent surface. It is made of type 1 collagen and laminin, using safe ingredients, which makes it biocompatible and absorbable within 10–14 days. The use of the coating is indicated for burns of I–III degrees, trophic ulcers and pressure sores, however, it is contraindicated in open bleeding wounds and hypersensitivity to the components. The study included 60 patients (28 men (46.67 %) were and 32 women (53.33 %)) aged from 27 to 92 years (mean age (66.8 ± ± 12.4) years old). The main procedures included demographic data collection, local screening, vital signs assessment, and NovoSkin application. Efficacy was assessed by the percentage of patients with an increase in granulation area of at least 20 % by day 14. The results. Absolute majority (96.67 %) of patients showed a significant increase in granulations, indicating a high coverage efficiency. The safety of the application was assessed through the frequency of undesirable events and changes in vital signs. No serious adverse events have been reported, which confirms NovoSkin’s good tolerability. Conclusion. NovoSkin wound coating has demonstrated high efficacy and safety in the treatment of skin defects, which makes it a promising tool in clinical practice. The test results confirm the product’s compliance with established standards and its feasibility for use in medical institutions.
- 28 October 2025
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 28 (3) , 97-106
Open AccessProspective testing of the effectiveness and safety of using a medical device “Wound coating based on the NovoSkin collagen-laminate matrix”
The study examines the effectiveness and safety of the medical device “Wound coating based on the NovoSkin collagen-laminate matrix”, conducted from February to May 2024 at the Ryazan State Medical University (Ryazan, Russia). Purpose of a study: to evaluate the use of wound coating NovoSkin in patients with skin defects. Materials and methods. NovoSkin is a sterile, round-shaped coating with a uniform matte and transparent surface. It is made of type 1 collagen and laminin, using safe ingredients, which makes it biocompatible and absorbable within 10–14 days. The use of the coating is indicated for burns of I–III degrees, trophic ulcers and pressure sores, however, it is contraindicated in open bleeding wounds and hypersensitivity to the components. The study included 60 patients (28 men (46.67 %) were and 32 women (53.33 %)) aged from 27 to 92 years (mean age (66.8 ± ± 12.4) years old). The main procedures included demographic data collection, local screening, vital signs assessment, and NovoSkin application. Efficacy was assessed by the percentage of patients with an increase in granulation area of at least 20 % by day 14. The results. Absolute majority (96.67 %) of patients showed a significant increase in granulations, indicating a high coverage efficiency. The safety of the application was assessed through the frequency of undesirable events and changes in vital signs. No serious adverse events have been reported, which confirms NovoSkin’s good tolerability. Conclusion. NovoSkin wound coating has demonstrated high efficacy and safety in the treatment of skin defects, which makes it a promising tool in clinical practice. The test results confirm the product’s compliance with established standards and its feasibility for use in medical institutions.
- Open Access
- 2 December 2024
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 27 (3) , 67-85
Formation of a sphincter mechanism in colostomy using titanium nickelide implants in an experiment
Purpose of the study: to conduct a comparative assessment of the formation of the sphincter mechanism during colostomy using titanium nickelide-based implants in an experiment.Material and methods. The experimental study was conducted on 45 sexually mature male rats Wistar with an average body weight of (531.3 ± 13.4) g. The animals were randomized into three equal groups of 15 animals each. In the 1st experimental group, a cylindrical spiral made of titanium nickelide with invagination of the serosalmuscular layer of the colon was used to create a colostomy. In the 2nd experimental group, a similar spiral was used, but without invagination of the serous-muscular layer. The control group underwent the standard procedure of single-barrel colostomy formation. Animals were removed from the experiment on the 7th, 30th and 60th days after the operation, 5 animals at each stage. Histologic examination of the area of the formed colostomy with constipation apparatus was performed.Results. The use of cylindrical spiral implants from titanium nickelide in colostomy formation (both with and without invagination of the serosal-muscular layer of the colon) had no significant effect on the dynamics of body weight of experimental animals compared to the classical method. Colostomy formation without invagination of the serous-muscular layer did not lead to an increase in the incidence of postoperative complications in comparison with the traditional method. However, invagination of the serous-muscular layer was accompanied by an increased incidence of complications in the postoperative period.Conclusion. The complex analysis of experimental data, including the assessment of survival rate, body weight dynamics, incidence of postoperative complications, morphological changes, the course of regenerative processes and stoma functionality, allows us to recommend as a promising method of colostomy the use of a cylindrical spiral made of titanium nickelide without invagination of the serous-muscular layer of the intestine.
- 2 December 2024
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 27 (3) , 67-85
Open AccessFormation of a sphincter mechanism in colostomy using titanium nickelide implants in an experiment
Purpose of the study: to conduct a comparative assessment of the formation of the sphincter mechanism during colostomy using titanium nickelide-based implants in an experiment.Material and methods. The experimental study was conducted on 45 sexually mature male rats Wistar with an average body weight of (531.3 ± 13.4) g. The animals were randomized into three equal groups of 15 animals each. In the 1st experimental group, a cylindrical spiral made of titanium nickelide with invagination of the serosalmuscular layer of the colon was used to create a colostomy. In the 2nd experimental group, a similar spiral was used, but without invagination of the serous-muscular layer. The control group underwent the standard procedure of single-barrel colostomy formation. Animals were removed from the experiment on the 7th, 30th and 60th days after the operation, 5 animals at each stage. Histologic examination of the area of the formed colostomy with constipation apparatus was performed.Results. The use of cylindrical spiral implants from titanium nickelide in colostomy formation (both with and without invagination of the serosal-muscular layer of the colon) had no significant effect on the dynamics of body weight of experimental animals compared to the classical method. Colostomy formation without invagination of the serous-muscular layer did not lead to an increase in the incidence of postoperative complications in comparison with the traditional method. However, invagination of the serous-muscular layer was accompanied by an increased incidence of complications in the postoperative period.Conclusion. The complex analysis of experimental data, including the assessment of survival rate, body weight dynamics, incidence of postoperative complications, morphological changes, the course of regenerative processes and stoma functionality, allows us to recommend as a promising method of colostomy the use of a cylindrical spiral made of titanium nickelide without invagination of the serous-muscular layer of the intestine.
- Open Access
- 12 December 2023
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 28 (4) , 88-92
Nodular hepatocellular carcinoma
The paper describes a clinical observation of asymptomatic course and late diagnosis of hepatocellular carcinoma with solitary giant tumor atypically located “on a pedicle” in a liver segment. The patient independently detected a neoplasm in the abdominal cavity. The paper presents stages of outpatient laboratory and instrumental diagnostics. Pattern of 13 cm tumor growth in one segment of the liver was considered uncommon but appropriate for the surgery – atypical liver resection. Such location of the tumor raised doubts about the organ reference prior to surgery. The patient underwent successful surgical treatment, specific treatment and follow-up in a certain medical institution.
- 12 December 2023
- Published by Annals of Surgical Hepatology in Annaly khirurgicheskoy gepatologii = Annals of HPB surgery
- Vol. 28 (4) , 88-92
Open AccessNodular hepatocellular carcinoma
The paper describes a clinical observation of asymptomatic course and late diagnosis of hepatocellular carcinoma with solitary giant tumor atypically located “on a pedicle” in a liver segment. The patient independently detected a neoplasm in the abdominal cavity. The paper presents stages of outpatient laboratory and instrumental diagnostics. Pattern of 13 cm tumor growth in one segment of the liver was considered uncommon but appropriate for the surgery – atypical liver resection. Such location of the tumor raised doubts about the organ reference prior to surgery. The patient underwent successful surgical treatment, specific treatment and follow-up in a certain medical institution.
- Open Access
- 17 April 2023
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 26 (1) , 15-29
Compression anastomoses in colon surgery (literature review)
А review of domestic and foreign literature on compression methods for the formation of colonic anastomoses is presented in the paper.Despite advances in the improvement of the manual suture of the colon, the frequency of postoperative complications remains high – 68.7%, while mortality ranges from 1% to 26%. Thus, it was not possible to achieve the absolute reliability of the traditional manual suture in the formation of colonic anastomoses.Compression anastomosis has an advantage over manual. When forming an anastomosis using a compression method, a decrease in time was noted, ease of creating an anastomosis, a significant decrease in postoperative complications and a high quality of the formed anastomoses, confirmed by morphological studies.
- 17 April 2023
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 26 (1) , 15-29
Open AccessCompression anastomoses in colon surgery (literature review)
А review of domestic and foreign literature on compression methods for the formation of colonic anastomoses is presented in the paper.Despite advances in the improvement of the manual suture of the colon, the frequency of postoperative complications remains high – 68.7%, while mortality ranges from 1% to 26%. Thus, it was not possible to achieve the absolute reliability of the traditional manual suture in the formation of colonic anastomoses.Compression anastomosis has an advantage over manual. When forming an anastomosis using a compression method, a decrease in time was noted, ease of creating an anastomosis, a significant decrease in postoperative complications and a high quality of the formed anastomoses, confirmed by morphological studies.
- Open Access
- 3 February 2023
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (4) , 92-97
State of the problem of artificial sphincter formation during colostomy (literature review)
Based on the analysis of domestic and foreign literature in the context of comparative effectiveness, the characteristics of the methods for creating an artificial sphincter during colostomy are presented. Various methods of colostomy formation are highlighted. Currently more than 200 methods and modifications of colostomy are known each of which has advantages and disadvantages and therefore cannot be considered ideal. In addition, there is the problem of maintenance of the colostomy associated with the constant functioning of the intestine and accordingly the release of contents. Therefore the search for a solution to the issue of preventing complications of terminal colostomy and improving the technique of forming an artificial anus is a very urgent and far from solved problem of operative coloproctology.
- 3 February 2023
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (4) , 92-97
Open AccessState of the problem of artificial sphincter formation during colostomy (literature review)
Based on the analysis of domestic and foreign literature in the context of comparative effectiveness, the characteristics of the methods for creating an artificial sphincter during colostomy are presented. Various methods of colostomy formation are highlighted. Currently more than 200 methods and modifications of colostomy are known each of which has advantages and disadvantages and therefore cannot be considered ideal. In addition, there is the problem of maintenance of the colostomy associated with the constant functioning of the intestine and accordingly the release of contents. Therefore the search for a solution to the issue of preventing complications of terminal colostomy and improving the technique of forming an artificial anus is a very urgent and far from solved problem of operative coloproctology.
- Open Access
- 31 October 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (3) , 86-91
History of the creation of autonomous electrical stimulators of the gastrointestinal tract
История создания автономных электростимуляторов желудочно-кишечного тракта
- 31 October 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (3) , 86-91
Open AccessHistory of the creation of autonomous electrical stimulators of the gastrointestinal tract
История создания автономных электростимуляторов желудочно-кишечного тракта
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 7-14
Usage composite ferroelectric membranes for healing of purulent wounds in the experiment
The paper contains the results of an experimental study of the effect of ferroelectric composite polymer membranes on the healing process of purulent wounds. The membranes were formed by electrospinning based on vinylidene fluoride-terafluoroethylene copolymer, polyvinylpyrrolidone K17 (PVP) polymer, zinc oxide nanoparticles (ZnO). Five spinning solutions with different contents of PVP were prepared: 0, 5, 10, 20 and 40 mass %.The effect of the membranes was evaluated depending on the content of PVP. The conductivity and viscosity ofthe spinning solutions were determined. The structure of the formed membranes was studied. The diameter of the fibers forming the membranes was determined by scanning electron microscopy. The antibacterial activity of the membranes was evaluated. The ability of the developed membranes to heal a purulent wound was studied in experiments on laboratory animals.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 7-14
Open AccessUsage composite ferroelectric membranes for healing of purulent wounds in the experiment
The paper contains the results of an experimental study of the effect of ferroelectric composite polymer membranes on the healing process of purulent wounds. The membranes were formed by electrospinning based on vinylidene fluoride-terafluoroethylene copolymer, polyvinylpyrrolidone K17 (PVP) polymer, zinc oxide nanoparticles (ZnO). Five spinning solutions with different contents of PVP were prepared: 0, 5, 10, 20 and 40 mass %.The effect of the membranes was evaluated depending on the content of PVP. The conductivity and viscosity ofthe spinning solutions were determined. The structure of the formed membranes was studied. The diameter of the fibers forming the membranes was determined by scanning electron microscopy. The antibacterial activity of the membranes was evaluated. The ability of the developed membranes to heal a purulent wound was studied in experiments on laboratory animals.
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 57-67
Elaboration and pilot study of 3D vaccines for oncotherapy
The purpose of the study was to study the possibility of using intracorporeal constructs in vivo with healthy or autologous dead tumor cells on porous extracellular matrix of titanium nickelide (PEMTN).We aimed to determine the advantage of the effect of this method on the change in the immunological status of cancer patients in comparison with patients receiving traditional treatment.The study used CBA and AKR JY mice and studied 10 patients with solid stage IV tumors of various localization (pancreas, intestines, lungs, ovary, head and neck) and 3 oncohematological patients (lymphoblastic lymphosarcoma, chronic myeloid leukemia (CML)).PEMTN was seeded with a suspension with bone marrow cells from CBA mice and cultured for 8 weeks in a long-term Dexter culture. It was shown that after 6 weeks of incubation of bone marrow cells on PEMNT in vitro, the proportion of bone marrow cells produced from the pores of the matrix into the liquid medium varied within 58–82%, which corresponded to the figures of the 1st week of incubation.After implantation of PEMTN with fetal liver cells in AKR/JY mice with spontaneous lympholeukemia, the implant successfully engrafted and after 30 days, no noticeable fluctuations in the leukocyte count were observed. After 3–4 weeks implantation, a 3-fold increase in the level of erythrocytes with fetal hemoglobin, which is not normally found in adult AKR/JY mice, was observed. There was also an increase (by 274%, p < 0.05) in the number of blood reticulocytes and a 26% decrease in the activity of the tumor process.In cancer patients with solid tumors, the level of SH-groups erythrocytes of blood increased 1.5–2.3 times 2 months after the implantation of hybrid oncotherapy implants carrying autologous apoptized tumor cells, treated in vitro. This implants, already 3–4 weeks after implantation in oncopatients, restored the blood system parameters.The most active (2–3 times) increased individual indicators of cellular immunity, in particular the number of NK cells, active (CD25+) and apoptotic lymphocytes (CD95+ marker). From the 3rd month of the study, the level of humoral immunity increased (immunoglobulins, circulating immune complexes). Clinically, the activation of immunity was accompanied by the stabilization of the process or a decrease in the volume and fragmentation of the primary nodes of solid tumors.In oncohematological patients, an increase in the CD95 marker in the peripheral cells of blood was observed.Therefore, in a patient with CML, the implantation, which followed therapy with low doses of cytostatics (myelosan, hydroxyurea) and the immune effect of the implantation, led to a 6-month hematological remission with normal values of the total number of leukocytes and leukocyte blood count. It has been shown that healthy cells in this matrix retain their viability and it allows them to multiply both in the in vitro system and in the in vivo system. The possibility of clinical use of PEMNT carrying autologous dead tumor cells treated in vitro with the aim of improving antitumor immunity, accelerating the recovery of blood counts in cancer patients and achieving partial remission has been shown.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 57-67
Open AccessElaboration and pilot study of 3D vaccines for oncotherapy
The purpose of the study was to study the possibility of using intracorporeal constructs in vivo with healthy or autologous dead tumor cells on porous extracellular matrix of titanium nickelide (PEMTN).We aimed to determine the advantage of the effect of this method on the change in the immunological status of cancer patients in comparison with patients receiving traditional treatment.The study used CBA and AKR JY mice and studied 10 patients with solid stage IV tumors of various localization (pancreas, intestines, lungs, ovary, head and neck) and 3 oncohematological patients (lymphoblastic lymphosarcoma, chronic myeloid leukemia (CML)).PEMTN was seeded with a suspension with bone marrow cells from CBA mice and cultured for 8 weeks in a long-term Dexter culture. It was shown that after 6 weeks of incubation of bone marrow cells on PEMNT in vitro, the proportion of bone marrow cells produced from the pores of the matrix into the liquid medium varied within 58–82%, which corresponded to the figures of the 1st week of incubation.After implantation of PEMTN with fetal liver cells in AKR/JY mice with spontaneous lympholeukemia, the implant successfully engrafted and after 30 days, no noticeable fluctuations in the leukocyte count were observed. After 3–4 weeks implantation, a 3-fold increase in the level of erythrocytes with fetal hemoglobin, which is not normally found in adult AKR/JY mice, was observed. There was also an increase (by 274%, p < 0.05) in the number of blood reticulocytes and a 26% decrease in the activity of the tumor process.In cancer patients with solid tumors, the level of SH-groups erythrocytes of blood increased 1.5–2.3 times 2 months after the implantation of hybrid oncotherapy implants carrying autologous apoptized tumor cells, treated in vitro. This implants, already 3–4 weeks after implantation in oncopatients, restored the blood system parameters.The most active (2–3 times) increased individual indicators of cellular immunity, in particular the number of NK cells, active (CD25+) and apoptotic lymphocytes (CD95+ marker). From the 3rd month of the study, the level of humoral immunity increased (immunoglobulins, circulating immune complexes). Clinically, the activation of immunity was accompanied by the stabilization of the process or a decrease in the volume and fragmentation of the primary nodes of solid tumors.In oncohematological patients, an increase in the CD95 marker in the peripheral cells of blood was observed.Therefore, in a patient with CML, the implantation, which followed therapy with low doses of cytostatics (myelosan, hydroxyurea) and the immune effect of the implantation, led to a 6-month hematological remission with normal values of the total number of leukocytes and leukocyte blood count. It has been shown that healthy cells in this matrix retain their viability and it allows them to multiply both in the in vitro system and in the in vivo system. The possibility of clinical use of PEMNT carrying autologous dead tumor cells treated in vitro with the aim of improving antitumor immunity, accelerating the recovery of blood counts in cancer patients and achieving partial remission has been shown.
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 15-24
Comparative evaluation of the effectiveness of bronchial stump formation using titanium nickelide and lavsan thread implant
Titanium nickelide is a promising material for use in surgical practice, starting from hernia gate plasty with the use of mesh implant, including the use of this material in surgical interventions of internal organs. Considering that the wound healing by primary tension occurs when using this material, this material is suitable for the formation of a bronchial stump. The results of the study are presented in this paper. 18 operated rats underwent lobectomy and formation of the bronchial stump using the titanium nickelide implant in 9 rats and formation of the bronchial stump using the lavsan thread. The results of macroscopic, radiological, barometric, histological studies and the results of electron microscopy are described and demonstrated.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 15-24
Open AccessComparative evaluation of the effectiveness of bronchial stump formation using titanium nickelide and lavsan thread implant
Titanium nickelide is a promising material for use in surgical practice, starting from hernia gate plasty with the use of mesh implant, including the use of this material in surgical interventions of internal organs. Considering that the wound healing by primary tension occurs when using this material, this material is suitable for the formation of a bronchial stump. The results of the study are presented in this paper. 18 operated rats underwent lobectomy and formation of the bronchial stump using the titanium nickelide implant in 9 rats and formation of the bronchial stump using the lavsan thread. The results of macroscopic, radiological, barometric, histological studies and the results of electron microscopy are described and demonstrated.
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 25-37
Regenerative effect tissue engineering scaffold based on fibrous permeable TiNi-based alloy
The aim of this study was to explore the in vivo applicability of intracorporeal constructions with hepatocytes cultured in the fiber TiNi-based scaffold (FTNS). We also sought to determine whether application of hepatocytes cultured in the FTNS was superior to simple hepatocyte injection in terms of restoration of liver functions and survival time in a CCl4-induced hepatitis rat model. In investigation 200 animals were assigned to explore the experimental groups as follows: Group I – control; Group II – animals with CCl4-induced hepatitis; Group III – animals with toxic hepatitis followed by implantation of cell-free FTNS (sham-surgery); Group IV – animals with toxic hepatitis followed by infusion of hepatocytes only (20 × 106 cells/ml); Group V – animals with toxic hepatitis followed by implantation of hepatocytes cultured in the FTNS. In terms of restoration of liver function, Group V showed a significant reduction of serum alanine aminotransferase level compared to Group II. Group IV also showed a significant decrease in ALT level at 15 days. However, the level of ALT increased at 30 days, and the level was similar with results of the Group II. This probably was caused by a short-term effect of hepatocyte injection only. The change patterns of serum protein, lactate, albumin, fibrinogen, and total bilirubin levels were similar to the results of ALT. The survival time of animals was significantly longer in Group V. These findings showed possible abilities of the FTNS as a scaffold to support the hepatocellular metabolism. Using 12 animals, image analysis of SEM data of in vivo hepatocyte evolution in the FTNS was carried out. In the SEM analysis, hepatocytes demonstrated good adhesion and proliferation in the pore space of the FTNS. Moreover, mature tissue comprising both colloidal and fibrous components filled the pore body by 95% in 28 days. Overall, this study sheds a light on how the implantable «auxiliary liver» by engrafting the cultured FTNS substitutes the missing hepatic function without the need to replace the whole liver.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 25-37
Open AccessRegenerative effect tissue engineering scaffold based on fibrous permeable TiNi-based alloy
The aim of this study was to explore the in vivo applicability of intracorporeal constructions with hepatocytes cultured in the fiber TiNi-based scaffold (FTNS). We also sought to determine whether application of hepatocytes cultured in the FTNS was superior to simple hepatocyte injection in terms of restoration of liver functions and survival time in a CCl4-induced hepatitis rat model. In investigation 200 animals were assigned to explore the experimental groups as follows: Group I – control; Group II – animals with CCl4-induced hepatitis; Group III – animals with toxic hepatitis followed by implantation of cell-free FTNS (sham-surgery); Group IV – animals with toxic hepatitis followed by infusion of hepatocytes only (20 × 106 cells/ml); Group V – animals with toxic hepatitis followed by implantation of hepatocytes cultured in the FTNS. In terms of restoration of liver function, Group V showed a significant reduction of serum alanine aminotransferase level compared to Group II. Group IV also showed a significant decrease in ALT level at 15 days. However, the level of ALT increased at 30 days, and the level was similar with results of the Group II. This probably was caused by a short-term effect of hepatocyte injection only. The change patterns of serum protein, lactate, albumin, fibrinogen, and total bilirubin levels were similar to the results of ALT. The survival time of animals was significantly longer in Group V. These findings showed possible abilities of the FTNS as a scaffold to support the hepatocellular metabolism. Using 12 animals, image analysis of SEM data of in vivo hepatocyte evolution in the FTNS was carried out. In the SEM analysis, hepatocytes demonstrated good adhesion and proliferation in the pore space of the FTNS. Moreover, mature tissue comprising both colloidal and fibrous components filled the pore body by 95% in 28 days. Overall, this study sheds a light on how the implantable «auxiliary liver» by engrafting the cultured FTNS substitutes the missing hepatic function without the need to replace the whole liver.