Romain Mailler
Romain Mailler has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Johnny Gasperi
LEE, Universite Gustave Eiffel, F-44344 Bouguenais, France
13 shared publications - Emmanuelle Vulliet
Universite Claude Bernard Lyon 1, CNRS, ISA, UMR5280, 5 rue de la Doua, F-69100 Villeurbanne, France
8 shared publications Vincent Rocher
Direction de l'Innovation, SIAAP, Colombes, France
8 shared publicationsV. Rocher
SIAAP (service public de l’assainissement francilien), Direction Innovation, Colombes, France
7 shared publications- Régis Moilleron
Leesu - Univ Paris Est Creteil, Ecole des Ponts, Creteil, F-94010, France
6 shared publications Catherine Morlay
Univ Lyon, CNRS, Université Claude Bernard Lyon 1, Institut National des Sciences Appliquées-Lyon, MATEIS, UMR 5510, Villeurbanne, France
5 shared publications
Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Devenir des micropolluants prioritaires et émergents dans les filières conventionnelles de traitement des eaux résiduaires urbaines (files eau et boues), et au cours du traitement tertiaire par charbon actif
Le premier chapitre de ce manuscrit est dédié aux traitements primaires et biologiques conventionnels. Les abattements de nombreux polluants prioritaires et émergents ont été déterminés pour la décantation, la décantation physico-chimique lamellaire, les boues activées faible charge et la biofiltration. Les composés hydrophobes et les métaux, les composés organiques volatils et les molécules biodégradables sont plutôt bien éliminés par ces filières. La normalisation des abattements à celui de l'azote a permis de démontrer que la filière décantation physico-chimique lamellaire + biofiltration a une efficacité comparable à la filière décantation + boues activées, bien que plus compacte et opérant avec un temps de séjour hydraulique plus faible. En complément, l'analyse dans trois effluents de STEP du SIAAP de 55 résidus pharmaceutiques et hormones (PPHs), et de 6 autres polluants émergents, a permis de caractériser finement la contamination de ces rejets par ces composés, et de montrer la forte fréquence de détection à des concentrations supérieures à 100 ng/L de 14 composés. Dans le second chapitre, les campagnes menées ont permis de fournir des données sur cinq types de boues, dont les boues brutes, centrifugées, digérées, séchées et les cakes de boues, et sur quatre procédés de traitement des boues communément utilisés en France (centrifugation, digestion anaérobie, séchage thermique et cuisson + filtration presse). De nombreux composés ont été détectés dans ces boues et ce à des niveaux de concentrations variant du µg/kg MS (matière sèche) au g/kg MS. Certains polluants, comme les LAS, métaux ou PCBs, ne sont pas du tout éliminés au cours des traitements des boues, entrainant une augmentation de leur teneur, alors que d'autres, tels que les alkylphénols ou les PPHs, sont abattus partiellement par digestion et séchage thermique. La digestion anaérobie est le procédé qui permet la meilleure élimination de ces composés. La présence de plusieurs composés dans les centrats et condensats indique qu'un transfert a lieu et que la biodégradation et la volatilisation ne sont pas les seuls mécanismes d'élimination. Le dernier chapitre décrit les performances d'un pilote de traitement tertiaire, fonctionnant avec du charbon actif en poudre (CAP) ou en micro-grain (CAµG), à l'échelle industrielle, au cours de 32 campagnes de mesure. Les résultats ont montré que la plupart des PPHs, alkylphénols, édulcorants, pesticides et parabènes pouvaient être abattus efficacement (> 80%) par du charbon actif en lit fluidisé, à des doses limitées de charbon (10-20 g/m3). La dose de charbon influence fortement les performances, que ce soit avec du CAP ou du CAµG. Le CAµG permet d'obtenir des abattements en PPHs comparables au CAP à une même dose (10 ou 20 gCAµG/m3), même si certains composés sont légèrement mieux abattus (5-15%) avec le CAP, probablement par l'action du FeCl3. Cependant, le CAµG a plusieurs avantages opérationnels par rapport au CAP. En particulier, le CAµG est réactivable, facile à utiliser, il fonctionne à des temps de séjour élevés favorisant le développement d'une activité biologique et sans ajout de coagulant/flocculant pour maintenir le lit de charbon. Par ailleurs, ce type de procédé permet l'affinage du traitement des paramètres globaux de qualité des eaux, notamment le CAµG qui retient les MES et élimine totalement les nitrites. La corrélation entre performances du procédé et abattement de l'absorbance UV à 254 nm a été établie, indiquant que ce paramètre pourrait être utilisé comme indicateur de performance. La mise en place d'expériences complémentaires en laboratoire a permis de mieux appréhender le processus de sorption sur le CAP. Le lien étroit entre surface spécifique, densité apparente du CAP et abattement des PPHs a été démontré, ainsi que l'importance de la dose de CAP et du temps de contact. L'impact positif du FeCl3, et l'influence négative de la quantité et de la qualité de la matière organique ont été observés
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Devenir des micropolluants prioritaires et émergents dans les filières conventionnelles de traitement des eaux résiduaires urbaines (files eau et boues), et au cours du traitement tertiaire par charbon actif
Le premier chapitre de ce manuscrit est dédié aux traitements primaires et biologiques conventionnels. Les abattements de nombreux polluants prioritaires et émergents ont été déterminés pour la décantation, la décantation physico-chimique lamellaire, les boues activées faible charge et la biofiltration. Les composés hydrophobes et les métaux, les composés organiques volatils et les molécules biodégradables sont plutôt bien éliminés par ces filières. La normalisation des abattements à celui de l'azote a permis de démontrer que la filière décantation physico-chimique lamellaire + biofiltration a une efficacité comparable à la filière décantation + boues activées, bien que plus compacte et opérant avec un temps de séjour hydraulique plus faible. En complément, l'analyse dans trois effluents de STEP du SIAAP de 55 résidus pharmaceutiques et hormones (PPHs), et de 6 autres polluants émergents, a permis de caractériser finement la contamination de ces rejets par ces composés, et de montrer la forte fréquence de détection à des concentrations supérieures à 100 ng/L de 14 composés. Dans le second chapitre, les campagnes menées ont permis de fournir des données sur cinq types de boues, dont les boues brutes, centrifugées, digérées, séchées et les cakes de boues, et sur quatre procédés de traitement des boues communément utilisés en France (centrifugation, digestion anaérobie, séchage thermique et cuisson + filtration presse). De nombreux composés ont été détectés dans ces boues et ce à des niveaux de concentrations variant du µg/kg MS (matière sèche) au g/kg MS. Certains polluants, comme les LAS, métaux ou PCBs, ne sont pas du tout éliminés au cours des traitements des boues, entrainant une augmentation de leur teneur, alors que d'autres, tels que les alkylphénols ou les PPHs, sont abattus partiellement par digestion et séchage thermique. La digestion anaérobie est le procédé qui permet la meilleure élimination de ces composés. La présence de plusieurs composés dans les centrats et condensats indique qu'un transfert a lieu et que la biodégradation et la volatilisation ne sont pas les seuls mécanismes d'élimination. Le dernier chapitre décrit les performances d'un pilote de traitement tertiaire, fonctionnant avec du charbon actif en poudre (CAP) ou en micro-grain (CAµG), à l'échelle industrielle, au cours de 32 campagnes de mesure. Les résultats ont montré que la plupart des PPHs, alkylphénols, édulcorants, pesticides et parabènes pouvaient être abattus efficacement (> 80%) par du charbon actif en lit fluidisé, à des doses limitées de charbon (10-20 g/m3). La dose de charbon influence fortement les performances, que ce soit avec du CAP ou du CAµG. Le CAµG permet d'obtenir des abattements en PPHs comparables au CAP à une même dose (10 ou 20 gCAµG/m3), même si certains composés sont légèrement mieux abattus (5-15%) avec le CAP, probablement par l'action du FeCl3. Cependant, le CAµG a plusieurs avantages opérationnels par rapport au CAP. En particulier, le CAµG est réactivable, facile à utiliser, il fonctionne à des temps de séjour élevés favorisant le développement d'une activité biologique et sans ajout de coagulant/flocculant pour maintenir le lit de charbon. Par ailleurs, ce type de procédé permet l'affinage du traitement des paramètres globaux de qualité des eaux, notamment le CAµG qui retient les MES et élimine totalement les nitrites. La corrélation entre performances du procédé et abattement de l'absorbance UV à 254 nm a été établie, indiquant que ce paramètre pourrait être utilisé comme indicateur de performance. La mise en place d'expériences complémentaires en laboratoire a permis de mieux appréhender le processus de sorption sur le CAP. Le lien étroit entre surface spécifique, densité apparente du CAP et abattement des PPHs a été démontré, ainsi que l'importance de la dose de CAP et du temps de contact. L'impact positif du FeCl3, et l'influence négative de la quantité et de la qualité de la matière organique ont été observés
- 6 September 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 8 (10) , 2358-2372
Biocidal substances in the Seine River: contribution from urban sources in the Paris megacity
This work addresses river contamination by biocidal substances up- and downstream a megacity, with the aim of investigating the contribution of urban discharges and proposing effective and concerted mitigation solutions. To this end, ten campaigns were conducted in the two main rivers of the Paris conurbation. Eighteen previously prioritized biocides were all quantified at three sampling locations, and several were found at concentrations that may present a risk to the aquatic ecosystem (dichloroisothiazolinone, diuron, and benzalkonium C12 and C14, with concentrations up to 42, 75, 1700, and 150 ng L−1, respectively). The collected data enabled the assessment of daily mass loads of biocides (from −1; 0.1 < isoproturon < 5.7 ng L−1), which may be related to urban inputs. Our results offer prospects for specific mitigation solutions at three scales: emissions, transport in the sewer system and treatment before discharge.
- 6 September 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 8 (10) , 2358-2372
Biocidal substances in the Seine River: contribution from urban sources in the Paris megacity
This work addresses river contamination by biocidal substances up- and downstream a megacity, with the aim of investigating the contribution of urban discharges and proposing effective and concerted mitigation solutions. To this end, ten campaigns were conducted in the two main rivers of the Paris conurbation. Eighteen previously prioritized biocides were all quantified at three sampling locations, and several were found at concentrations that may present a risk to the aquatic ecosystem (dichloroisothiazolinone, diuron, and benzalkonium C12 and C14, with concentrations up to 42, 75, 1700, and 150 ng L−1, respectively). The collected data enabled the assessment of daily mass loads of biocides (from −1; 0.1 < isoproturon < 5.7 ng L−1), which may be related to urban inputs. Our results offer prospects for specific mitigation solutions at three scales: emissions, transport in the sewer system and treatment before discharge.
- 9 December 2021
- Published by Taylor & Francis in Environmental Technology
- Vol. 44 (11) , 1653-1666
Long-term performances and membrane lifespan of full-scale MBR treating filtrate from sludge ultra-dewatering
A MBR treating filtrate from sludge ultra-dewatering (FSD) was studied in order to evaluate the real applicability to concentrated effluents. The MBR operation is comparable to conventional wastewater MBRs in terms of F/M and nitrogen to sludge ratios, SRT and MLSS in biological tanks. In contrary, the volume treated is lower with a comparable pollution load, the effluent being concentrated in nitrogen and carbon. Very high and stable ammonium (97.7 ± 2.4%), total phosphorus (81.8 ± 11.9%), chemical (89.5 ± 2.3%) and biochemical oxygen demands (98.8 ± 0.7%) removals are observed despite a significant modification of the FSD composition. The MBR removal performances are whether comparable or greater than those reported at full-scale for Sharon or Anammox processes. The evolution of membranes properties, in particular the decrease of permeability induced by the irreversible fouling, lead to a decrease of the daily permeate volume produced and an increase of the chemical cleaning need. The membrane lifespan was determined to be 5.5 years based on both the permeability loss and TSS in permeate. The permeability is directly correlated to the cumulated filtered flux of colloidal matter and a total of 350 kg O2 / m2 of membrane (COD in supernatant) is needed to reach a permeability below 100 LMH/bar. The specific energy consumption is comparable to other wastewater MBRs in kWh / kgCOD removed but the intensive chemical cleanings need to be 2.5 to 4.5 times more frequent. Overall, it can be concluded that MBR is adapted to treat FSD efficiently. GRAPHICAL ABSTRACT
- 9 December 2021
- Published by Taylor & Francis in Environmental Technology
- Vol. 44 (11) , 1653-1666
Long-term performances and membrane lifespan of full-scale MBR treating filtrate from sludge ultra-dewatering
A MBR treating filtrate from sludge ultra-dewatering (FSD) was studied in order to evaluate the real applicability to concentrated effluents. The MBR operation is comparable to conventional wastewater MBRs in terms of F/M and nitrogen to sludge ratios, SRT and MLSS in biological tanks. In contrary, the volume treated is lower with a comparable pollution load, the effluent being concentrated in nitrogen and carbon. Very high and stable ammonium (97.7 ± 2.4%), total phosphorus (81.8 ± 11.9%), chemical (89.5 ± 2.3%) and biochemical oxygen demands (98.8 ± 0.7%) removals are observed despite a significant modification of the FSD composition. The MBR removal performances are whether comparable or greater than those reported at full-scale for Sharon or Anammox processes. The evolution of membranes properties, in particular the decrease of permeability induced by the irreversible fouling, lead to a decrease of the daily permeate volume produced and an increase of the chemical cleaning need. The membrane lifespan was determined to be 5.5 years based on both the permeability loss and TSS in permeate. The permeability is directly correlated to the cumulated filtered flux of colloidal matter and a total of 350 kg O2 / m2 of membrane (COD in supernatant) is needed to reach a permeability below 100 LMH/bar. The specific energy consumption is comparable to other wastewater MBRs in kWh / kgCOD removed but the intensive chemical cleanings need to be 2.5 to 4.5 times more frequent. Overall, it can be concluded that MBR is adapted to treat FSD efficiently. GRAPHICAL ABSTRACT
- 1 February 2021
- Published by Elsevier in Water Research
- Vol. 190, 116749
Fluorescence excitation/emission matrices as a tool to monitor the removal of organic micropollutants from wastewater effluents by adsorption onto activated carbon
- 1 February 2021
- Published by Elsevier in Water Research
- Vol. 190, 116749
Fluorescence excitation/emission matrices as a tool to monitor the removal of organic micropollutants from wastewater effluents by adsorption onto activated carbon
- 1 February 2021
- Published by Elsevier in Journal of Environmental Management
- Vol. 280, 111745
Sludge conditioning, thickening and dewatering optimization in a screw centrifuge decanter: Which means for which result?
- 1 February 2021
- Published by Elsevier in Journal of Environmental Management
- Vol. 280, 111745
Sludge conditioning, thickening and dewatering optimization in a screw centrifuge decanter: Which means for which result?
- Open Access
- 4 January 2021
- Published by IWA Publishing in Water Science & Technology
- Vol. 83 (4) , 781-791
What removals of pathogen indicators can be expected within large-scale wastewater treatment facilities in the context of wastewater reuse in Paris conurbation?
The fate of pathogen indicators (Escherichia coli – EC, intestinal enterococci – IE, RNA-F bacteriophages and spores of sulfite reducing bacteria – SSR) was extensively studied in Parisian large-scale wastewater treatment plants (WWTPs), based on conventional activated sludge, biofiltration or membrane bioreactor (MBR) processes. Between 14 and 87 campaigns were performed between 2014 and 2018 in five WWTPs. High removals of 3 log for both EC and IE, and lower removals of 1–2 log for SSR and RNA-F bacteriophages, were observed in conventional activated sludge and biofiltration WWTPs. The MBR WWTP achieves notably greater removals of 4.5–5.5 log for faecal bacteria and 3–4 log for SSR and RNA-F bacteriophages. This WWTP is the only one already in compliance with reuse standards, the other ones being non-compliant because of SSR and RNA-F bacteriophages. The implementation of a micro-grain activated carbon process would increase the WWTP removals of 0.8 log for faecal bacteria, due to particles retention, with no significant effect on both other pathogens. Ozonation (0.9–1.3 g O3/g dissolved organic carbon) or performic acid (0.8–1.2 ppm) would have greater benefits with additional removals of 1.5–2.5 log for EC, 1–2 log for IE and 0.5–1 log for SSR and RNA-F bacteriophages. Correlations between pathogen indicator removals and initial concentrations were found, as well as a significant decrease of RNA-F bacteriophage concentrations in Parisian raw wastewater, below 2 log. Thus, RNA-F bacteriophages could be a real issue to evaluate the compliance of Parisian wastewater with reuse. The time evolution of removals demonstrated that SSR is the most problematic parameter regarding reuse in conventional activated sludge and biofiltration WWTPs, as its initial concentration is high (5 log) but removals insufficient (<2 log). In contrast, removals of RNA-F bacteriophages greater than 2 log can be obtained within WWTPs completed or not with a tertiary treatment when the initial concentration in raw wastewater is sufficient. Correlations were also found between the removals of pathogen indicators and the removals of physico-chemical parameters, but they are not good enough to allow performance predictions.
- 4 January 2021
- Published by IWA Publishing in Water Science & Technology
- Vol. 83 (4) , 781-791
Open AccessWhat removals of pathogen indicators can be expected within large-scale wastewater treatment facilities in the context of wastewater reuse in Paris conurbation?
The fate of pathogen indicators (Escherichia coli – EC, intestinal enterococci – IE, RNA-F bacteriophages and spores of sulfite reducing bacteria – SSR) was extensively studied in Parisian large-scale wastewater treatment plants (WWTPs), based on conventional activated sludge, biofiltration or membrane bioreactor (MBR) processes. Between 14 and 87 campaigns were performed between 2014 and 2018 in five WWTPs. High removals of 3 log for both EC and IE, and lower removals of 1–2 log for SSR and RNA-F bacteriophages, were observed in conventional activated sludge and biofiltration WWTPs. The MBR WWTP achieves notably greater removals of 4.5–5.5 log for faecal bacteria and 3–4 log for SSR and RNA-F bacteriophages. This WWTP is the only one already in compliance with reuse standards, the other ones being non-compliant because of SSR and RNA-F bacteriophages. The implementation of a micro-grain activated carbon process would increase the WWTP removals of 0.8 log for faecal bacteria, due to particles retention, with no significant effect on both other pathogens. Ozonation (0.9–1.3 g O3/g dissolved organic carbon) or performic acid (0.8–1.2 ppm) would have greater benefits with additional removals of 1.5–2.5 log for EC, 1–2 log for IE and 0.5–1 log for SSR and RNA-F bacteriophages. Correlations between pathogen indicator removals and initial concentrations were found, as well as a significant decrease of RNA-F bacteriophage concentrations in Parisian raw wastewater, below 2 log. Thus, RNA-F bacteriophages could be a real issue to evaluate the compliance of Parisian wastewater with reuse. The time evolution of removals demonstrated that SSR is the most problematic parameter regarding reuse in conventional activated sludge and biofiltration WWTPs, as its initial concentration is high (5 log) but removals insufficient (<2 log). In contrast, removals of RNA-F bacteriophages greater than 2 log can be obtained within WWTPs completed or not with a tertiary treatment when the initial concentration in raw wastewater is sufficient. Correlations were also found between the removals of pathogen indicators and the removals of physico-chemical parameters, but they are not good enough to allow performance predictions.
- 1 June 2020
- Published by Taylor & Francis in Environmental Technology
- Vol. 42 (25) , 4015-4026
Normalization of wastewater coagulation-flocculation trials and implications in terms of variability in treatment performance and comparison of commercial coagulants
Normalizations by TSS or P-PO43- initial concentrations are consistent as they are correlated to the Jar-test performances. Jar-tests results are independent of the wastewater quality variations in terms of TSS and P-PO43- and independent of the WWTP origin of the water. A notable variability in the TSS results indicates that the pollutant’s initial load has to be taken into account even with normalizations. This variability is lower with normalization by P-PO43-, indicating that this is the best indicator to consider. It is possible to determine that the optimal cation dosage is 60 mol Fe3+ / kg P-PO43- as it guarantees a residual concentration of 0.7-1.0 mgP/L and a good removal of TSS. Then, six commercially available cationic coagulants were compared, demonstrating a comparable effect at a comparable normalized molar dose, whatever the coagulant on both TSS and P-PO43-, as well as on soluble carbon and nitrogen. The differences observed between these types of coagulants in the literature are then probably due to methodological issues. Settling velocity distribution charts were also very similar for the different coagulants. This confirms that the source of cation and the type of cation have no significant effect on physico-chemical settling performances. HIGHLIGHTS
- 1 June 2020
- Published by Taylor & Francis in Environmental Technology
- Vol. 42 (25) , 4015-4026
Normalization of wastewater coagulation-flocculation trials and implications in terms of variability in treatment performance and comparison of commercial coagulants
Normalizations by TSS or P-PO43- initial concentrations are consistent as they are correlated to the Jar-test performances. Jar-tests results are independent of the wastewater quality variations in terms of TSS and P-PO43- and independent of the WWTP origin of the water. A notable variability in the TSS results indicates that the pollutant’s initial load has to be taken into account even with normalizations. This variability is lower with normalization by P-PO43-, indicating that this is the best indicator to consider. It is possible to determine that the optimal cation dosage is 60 mol Fe3+ / kg P-PO43- as it guarantees a residual concentration of 0.7-1.0 mgP/L and a good removal of TSS. Then, six commercially available cationic coagulants were compared, demonstrating a comparable effect at a comparable normalized molar dose, whatever the coagulant on both TSS and P-PO43-, as well as on soluble carbon and nitrogen. The differences observed between these types of coagulants in the literature are then probably due to methodological issues. Settling velocity distribution charts were also very similar for the different coagulants. This confirms that the source of cation and the type of cation have no significant effect on physico-chemical settling performances. HIGHLIGHTS
- 1 April 2020
- Published by Elsevier in Water Research
- Vol. 172, 115487
Influence of dissolved organic matter on the removal of 12 organic micropollutants from wastewater effluent by powdered activated carbon adsorption
- 1 April 2020
- Published by Elsevier in Water Research
- Vol. 172, 115487
Influence of dissolved organic matter on the removal of 12 organic micropollutants from wastewater effluent by powdered activated carbon adsorption
- 1 April 2020
- Published by Elsevier in Chemosphere
- Vol. 245, 125530
Benefits of ozonation before activated carbon adsorption for the removal of organic micropollutants from wastewater effluents
- 1 April 2020
- Published by Elsevier in Chemosphere
- Vol. 245, 125530
Benefits of ozonation before activated carbon adsorption for the removal of organic micropollutants from wastewater effluents