Jonas Hansson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jonas Hansson has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Wouter van der Wijngaart
KTH Royal Institute of Technology, Sweden
7 shared publications - Aman Russom
Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden
4 shared publications Tommy Haraldsson
KTH Royal Institute of Technology, Stockholm, Sweden
3 shared publicationsCarl Fredrik Carlborg
KTH Royal Institute of Technology, Stockholm, Sweden
2 shared publications- Hjalmar Brismar
KTH Royal Institute of Technology
2 shared publications J. Mikael Karlsson
KTH Royal Institute of Technology, Stockholm, Sweden
2 shared publications
Latest Publications
- 23 April 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (9) , 6194-6199
Synthetic Paper Separates Plasma from Whole Blood with Low Protein Loss
The separation of plasma from whole blood is the first step in many diagnostic tests. Point-of-care tests often rely on integrated plasma filters, but protein retention in such filters limits their performance. Here, we investigate plasma separation on interlocked micropillar scaffolds ("synthetic paper") by the local agglutination of blood cells coupled with the capillary separation of the plasma. We separated clinically relevant volumes of plasma with high efficiency in a separation time on par with that of state of the art techniques. We investigated different covalent and non-covalent surface treatments (PEGMA, HEMA, BSA, O2 plasma) on our blood filter and their effect on protein recovery, and identified O2 plasma treatment and 7.9 μg/cm2 agglutination antibody as most suitable treatments. Using these treatments, we recovered at least 82% of the blood plasma proteins, more than with state-of-the-art filters. The simplicity of our device and the performance of our approach could enable better point-of-care tests.
- 23 April 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (9) , 6194-6199
Synthetic Paper Separates Plasma from Whole Blood with Low Protein Loss
The separation of plasma from whole blood is the first step in many diagnostic tests. Point-of-care tests often rely on integrated plasma filters, but protein retention in such filters limits their performance. Here, we investigate plasma separation on interlocked micropillar scaffolds ("synthetic paper") by the local agglutination of blood cells coupled with the capillary separation of the plasma. We separated clinically relevant volumes of plasma with high efficiency in a separation time on par with that of state of the art techniques. We investigated different covalent and non-covalent surface treatments (PEGMA, HEMA, BSA, O2 plasma) on our blood filter and their effect on protein recovery, and identified O2 plasma treatment and 7.9 μg/cm2 agglutination antibody as most suitable treatments. Using these treatments, we recovered at least 82% of the blood plasma proteins, more than with state-of-the-art filters. The simplicity of our device and the performance of our approach could enable better point-of-care tests.
- 31 October 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (22) , 13393-13399
High-Yield Passive Plasma Filtration from Human Finger Prick Blood
Whole-blood microsampling provides many benefits such as remote, patient-centric, and minimally invasive sampling. However, blood plasma, and not whole blood, is the prevailing matrix in clinical laboratory investigations. The challenge with plasma microsampling is to extract plasma volumes large enough to reliably detect low-concentration analytes from a small finger prick sample. Here we introduce a passive plasma filtration device that provides a high extraction yield of 65 %, filtering 18 µl of plasma from 50 µl of undiluted human whole blood (hematocrit 45 %) within less than 10 minutes. The enabling design element is a wedge-shaped connection between the blood filter and the hydrophilic bottom surface of a capillary channel. Using finger prick and venous blood samples from more than 10 healthy volunteers, we examined the filtration kinetics of the device over a hematocrit range of 35-55 % and showed that 73 ± 8 % of the total protein content was successfully recovered after filtration. The presented plasma filtration device tackles a major challenge towards patient-centric blood microsampling by providing high-yield plasma filtration, potentially allowing reliable detection of low-concentration analytes from a blood microsample.
- 31 October 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (22) , 13393-13399
High-Yield Passive Plasma Filtration from Human Finger Prick Blood
Whole-blood microsampling provides many benefits such as remote, patient-centric, and minimally invasive sampling. However, blood plasma, and not whole blood, is the prevailing matrix in clinical laboratory investigations. The challenge with plasma microsampling is to extract plasma volumes large enough to reliably detect low-concentration analytes from a small finger prick sample. Here we introduce a passive plasma filtration device that provides a high extraction yield of 65 %, filtering 18 µl of plasma from 50 µl of undiluted human whole blood (hematocrit 45 %) within less than 10 minutes. The enabling design element is a wedge-shaped connection between the blood filter and the hydrophilic bottom surface of a capillary channel. Using finger prick and venous blood samples from more than 10 healthy volunteers, we examined the filtration kinetics of the device over a hematocrit range of 35-55 % and showed that 73 ± 8 % of the total protein content was successfully recovered after filtration. The presented plasma filtration device tackles a major challenge towards patient-centric blood microsampling by providing high-yield plasma filtration, potentially allowing reliable detection of low-concentration analytes from a blood microsample.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 339-341
Capillary pumping with a constant flow rate independent of the liquid sample viscosity and surface energy
We introduce and experimentally verify a capillary pump design that, for the first time, enables autonomous pumping of sample liquid with a flow rate constant in time and independent of the sample viscosity and sample surface energy. These results are of interest for applications that rely on a predictable flow rate and where the sample fluid viscosity or surface energy are not precisely known, e.g. in capillary driven diagnostic lateral flow biosensors for urine or blood sample, where large variations exist in both viscosity and surface energy between different patient samples.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 339-341
Capillary pumping with a constant flow rate independent of the liquid sample viscosity and surface energy
We introduce and experimentally verify a capillary pump design that, for the first time, enables autonomous pumping of sample liquid with a flow rate constant in time and independent of the sample viscosity and sample surface energy. These results are of interest for applications that rely on a predictable flow rate and where the sample fluid viscosity or surface energy are not precisely known, e.g. in capillary driven diagnostic lateral flow biosensors for urine or blood sample, where large variations exist in both viscosity and surface energy between different patient samples.
- 4 March 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (8) , 1439-1446
Leak-tight vertical membrane microvalves
Pneumatic microvalves are fundamental control components in a large range of microfluidic applications. Their key performance parameters are small size, i.e. occupying a minimum of microfluidic real estate, low flow resistance in the open state, and leak-tight closing at limited control pressures. In this work we present the successful design, realization and evaluation of the first leak-tight, vertical membrane, pneumatic microvalves. The realization of the vertical membrane microvalves is enabled by a novel dual-sided molding method for microstructuring monolithic 3D microfluidic networks in PDMS in a single step, eliminating the need for layer-to-layer alignment during bonding. We demonstrate minimum lateral device features down to 20–30 μm in size, and vertical via density of ∼30 000 per cm2, which provides significant gains in chip real estate compared to previously reported PDMS manufacturing methods. In contrast to horizontal membrane microvalves, there are no manufacturing restrictions on the cross-sectional geometry of the flow channel of the vertical membrane microvalves. This allows tuning the design towards lower closing pressure or lower open state flow resistance compared to those of horizontal membrane microvalves.
- 4 March 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (8) , 1439-1446
Leak-tight vertical membrane microvalves
Pneumatic microvalves are fundamental control components in a large range of microfluidic applications. Their key performance parameters are small size, i.e. occupying a minimum of microfluidic real estate, low flow resistance in the open state, and leak-tight closing at limited control pressures. In this work we present the successful design, realization and evaluation of the first leak-tight, vertical membrane, pneumatic microvalves. The realization of the vertical membrane microvalves is enabled by a novel dual-sided molding method for microstructuring monolithic 3D microfluidic networks in PDMS in a single step, eliminating the need for layer-to-layer alignment during bonding. We demonstrate minimum lateral device features down to 20–30 μm in size, and vertical via density of ∼30 000 per cm2, which provides significant gains in chip real estate compared to previously reported PDMS manufacturing methods. In contrast to horizontal membrane microvalves, there are no manufacturing restrictions on the cross-sectional geometry of the flow channel of the vertical membrane microvalves. This allows tuning the design towards lower closing pressure or lower open state flow resistance compared to those of horizontal membrane microvalves.
- 21 November 2014
- Published by Springer Nature in Biotechnology Letters
- Vol. 37 (4) , 825-830
Microfluidic-based isolation of bacteria from whole blood for sepsis diagnostics
Blood-stream infections (BSI) remain a major health challenge, with an increasing incidence worldwide and a high mortality rate. Early treatment with appropriate antibiotics can reduce BSI-related morbidity and mortality, but success requires rapid identification of the infecting organisms. The rapid, culture-independent diagnosis of BSI could be significantly facilitated by straightforward isolation of highly purified bacteria from whole blood. We present a microfluidic-based, sample-preparation system that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100 % viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.
- 21 November 2014
- Published by Springer Nature in Biotechnology Letters
- Vol. 37 (4) , 825-830
Microfluidic-based isolation of bacteria from whole blood for sepsis diagnostics
Blood-stream infections (BSI) remain a major health challenge, with an increasing incidence worldwide and a high mortality rate. Early treatment with appropriate antibiotics can reduce BSI-related morbidity and mortality, but success requires rapid identification of the infecting organisms. The rapid, culture-independent diagnosis of BSI could be significantly facilitated by straightforward isolation of highly purified bacteria from whole blood. We present a microfluidic-based, sample-preparation system that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100 % viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10846999,p. 987-990
Low gas permeable and non-absorbent rubbery OSTE+ for pneumatic microvalves
In this paper we introduce a new polymer for use in microfluidic applications, based on the off-stoichiometric thiol-ene-epoxy (OSTE+) polymer system, but with rubbery properties. We characterize and benchmark the new polymer against PDMS. We demonstrate that Rubbery OSTE+: has more than 90% lower permeability to gases compared to PDMS, has little to no absorption of dissolved molecules, can be layer bonded in room temperature without the need for adhesives or plasma treatment, can be structured by standard micro-molding manufacturing, and shows similar performance as PDMS for pneumatic microvalves, albeit allowing handling of larger pressure.
- 1 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10846999,p. 987-990
Low gas permeable and non-absorbent rubbery OSTE+ for pneumatic microvalves
In this paper we introduce a new polymer for use in microfluidic applications, based on the off-stoichiometric thiol-ene-epoxy (OSTE+) polymer system, but with rubbery properties. We characterize and benchmark the new polymer against PDMS. We demonstrate that Rubbery OSTE+: has more than 90% lower permeability to gases compared to PDMS, has little to no absorption of dissolved molecules, can be layer bonded in room temperature without the need for adhesives or plasma treatment, can be structured by standard micro-molding manufacturing, and shows similar performance as PDMS for pneumatic microvalves, albeit allowing handling of larger pressure.
- 27 July 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (22) , 4644-4650
Inertial microfluidics in parallel channels for high-throughput applications
Passive particle focusing based on inertial microfluidics was recently introduced as a high-throughput alternative to active focusing methods that require an external force-field to manipulate particles. In this study, we introduce inertial microfluidics in flows through straight, multiple parallel channels. The scalable, single inlet and two outlet, parallel channel system is enabled by a novel, high-density 3D PDMS microchannel manufacturing technology, mediated via a targeted inhibition of PDMS polymerization. Using single channels, we first demonstrate how randomly distributed particles can be focused into the centre position of the channel in flows through low aspect ratio channels and can be effectively fractionated. As a proof of principle, continuous focusing and filtration of 10 μm particles from a suspension mixture using 4- and 16-parallel-channel devices with a single inlet and two outlets are demonstrated. A filtration efficiency of 95–97% was achieved at throughputs several orders of magnitude higher than previously shown for flows through straight channels. The scalable and low-footprint focusing device requiring neither external force fields nor mechanical parts to operate is readily applicable for high-throughput focusing and filtration applications as a stand-alone device or integrated with lab-on-a-chip systems.
- 27 July 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (22) , 4644-4650
Inertial microfluidics in parallel channels for high-throughput applications
Passive particle focusing based on inertial microfluidics was recently introduced as a high-throughput alternative to active focusing methods that require an external force-field to manipulate particles. In this study, we introduce inertial microfluidics in flows through straight, multiple parallel channels. The scalable, single inlet and two outlet, parallel channel system is enabled by a novel, high-density 3D PDMS microchannel manufacturing technology, mediated via a targeted inhibition of PDMS polymerization. Using single channels, we first demonstrate how randomly distributed particles can be focused into the centre position of the channel in flows through low aspect ratio channels and can be effectively fractionated. As a proof of principle, continuous focusing and filtration of 10 μm particles from a suspension mixture using 4- and 16-parallel-channel devices with a single inlet and two outlets are demonstrated. A filtration efficiency of 95–97% was achieved at throughputs several orders of magnitude higher than previously shown for flows through straight channels. The scalable and low-footprint focusing device requiring neither external force fields nor mechanical parts to operate is readily applicable for high-throughput focusing and filtration applications as a stand-alone device or integrated with lab-on-a-chip systems.
- 4 July 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (8)
Fabrication and transfer of fragile 3D PDMS microstructures
- 4 July 2012
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 22 (8)
Fabrication and transfer of fragile 3D PDMS microstructures
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1777-1780
Inertial particle focusing in parallel microfluidic channels for high-throughput filtration
In this study, we introduce inertial microfluidics in straight, parallel channels for high-throughput particle filtration. We show that particles flowing through low aspect ratio rectangular microchannels can be focused into four particle streams, distributed at the centers of each wall face, or into two particle streams, at the centers of the longest channel walls, depending on the particles' size. For high-throughput filtration, we fabricated scalable, single inlet and two outlet, parallel channel microdevices, using a high-density 3D microfluidic PDMS channel manufacturing technology, in a design that allows for easy integration with other downstream on-chip functions we recently described. We demonstrate filtration of 24 μm particles from a suspension mixture in a microdevice with four parallel channels. The filtration efficiency at a non-optimized flow rate of 0.8 ml/min was 82%.
- 1 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2159547X,p. 1777-1780
Inertial particle focusing in parallel microfluidic channels for high-throughput filtration
In this study, we introduce inertial microfluidics in straight, parallel channels for high-throughput particle filtration. We show that particles flowing through low aspect ratio rectangular microchannels can be focused into four particle streams, distributed at the centers of each wall face, or into two particle streams, at the centers of the longest channel walls, depending on the particles' size. For high-throughput filtration, we fabricated scalable, single inlet and two outlet, parallel channel microdevices, using a high-density 3D microfluidic PDMS channel manufacturing technology, in a design that allows for easy integration with other downstream on-chip functions we recently described. We demonstrate filtration of 24 μm particles from a suspension mixture in a microdevice with four parallel channels. The filtration efficiency at a non-optimized flow rate of 0.8 ml/min was 82%.