Paolo Cecchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paolo Cecchi has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Mirco Cosottini
Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
13 shared publications - Stefano Diciotti
Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi”, University of Bologna, Cesena, Italy
11 shared publications Ilaria Pesaresi
Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Risorgimento 36, Pisa 56126, Italy
8 shared publications- Ubaldo Bonuccelli
Department of Clinical and Experimental Medicine, Neurology Unit, University of Pisa, Pisa, Italy
8 shared publications Andrea Ginestroni
7 shared publicationsMario Mascalchi
7 shared publications
Latest Publications
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 36085-36098
Enhancing Radar-Based Stroke Detection: A Novel Approach Integrating Huygens’ Principle and Deep Learning Techniques
Microwave imaging is rapidly gaining prominence as a favorable alternative to X-ray and MRI for various medical applications. In this study, we focus on investigating the Huygens’ principle (HP) imaging method for brain imaging to detect strokes. The method has already shown promise in clinical trials for breast cancer detection. Adapting HP for brain imaging presents distinct challenges due to the brain’s complex structure, necessitating the integration of advanced techniques. Current advancements in artificial intelligence and deep learning, despite their reliance on extensive datasets, offer valuable enhancements over traditional signal-processing methods. Through Finite Difference Time Domain (FDTD) simulations, we are able to generate the necessary comprehensive datasets, enabling the effective application of deep learning. Techniques such as U-net are explored for their ability to refine HP images into detailed stroke representations. Our findings through simulations demonstrate that integrating the magnitude and phase of HP imaging with deep learning methods significantly enhances stroke detection and classification. Specifically, using the magnitude of HP images resulted in an 83% accuracy rate in stroke classification, whereas utilizing the phase of HP images achieved an accuracy rate of 97%. Moreover, we successfully tested our model using data collected from two patients who participated in our first round of clinical trials.
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 36085-36098
Enhancing Radar-Based Stroke Detection: A Novel Approach Integrating Huygens’ Principle and Deep Learning Techniques
Microwave imaging is rapidly gaining prominence as a favorable alternative to X-ray and MRI for various medical applications. In this study, we focus on investigating the Huygens’ principle (HP) imaging method for brain imaging to detect strokes. The method has already shown promise in clinical trials for breast cancer detection. Adapting HP for brain imaging presents distinct challenges due to the brain’s complex structure, necessitating the integration of advanced techniques. Current advancements in artificial intelligence and deep learning, despite their reliance on extensive datasets, offer valuable enhancements over traditional signal-processing methods. Through Finite Difference Time Domain (FDTD) simulations, we are able to generate the necessary comprehensive datasets, enabling the effective application of deep learning. Techniques such as U-net are explored for their ability to refine HP images into detailed stroke representations. Our findings through simulations demonstrate that integrating the magnitude and phase of HP imaging with deep learning methods significantly enhances stroke detection and classification. Specifically, using the magnitude of HP images resulted in an 83% accuracy rate in stroke classification, whereas utilizing the phase of HP images achieved an accuracy rate of 97%. Moreover, we successfully tested our model using data collected from two patients who participated in our first round of clinical trials.
- Open Access
- 8 April 2024
- Published by Wiley in Journal of Neuroimaging
- Vol. 34 (4) , 475-485
Detection of pathological contrast enhancement with synthetic brain imaging from quantitative multiparametric MRI
Background and Purpose: We aimed to test whether synthetic T1‐weighted imaging derived from a post‐contrast Quantitative Transient‐state Imaging (QTI) acquisition enabled revealing pathological contrast enhancement in intracranial lesions.Methods: The analysis included 141 patients who underwent a 3 Tesla‐MRI brain exam with intravenous contrast media administration, with the post‐contrast acquisition protocol comprising a three‐dimensional fast spoiled gradient echo (FSPGR) sequence and a QTI acquisition. Synthetic T1‐weighted images were generated from QTI‐derived quantitative maps of relaxation times and proton density. Two neuroradiologists assessed synthetic and conventional post‐contrast T1‐weighted images for the presence and pattern of pathological contrast enhancement in intracranial lesions. Enhancement volumes were quantitatively compared.Results: Using conventional imaging as a reference, synthetic T1‐weighted imaging was 93% sensitive in revealing the presence of contrast enhancing lesions. The agreement for the presence/absence of contrast enhancement was almost perfect both between readers (k = 1 for both conventional and synthetic imaging) and between sequences (k = 0.98 for both readers). In 91% of lesions, synthetic T1‐weighted imaging showed the same pattern of contrast enhancement visible in conventional imaging. Differences in enhancement pattern in the remaining lesions can be due to the lower spatial resolution and the longer acquisition delay from contrast media administration of QTI compared to FSPGR. Overall, enhancement volumes appeared larger in synthetic imaging.Conclusions: QTI‐derived post‐contrast synthetic T1‐weighted imaging captures pathological contrast enhancement in most intracranial enhancing lesions. Further comparative studies employing quantitative imaging with higher spatial resolution is needed to support our data and explore possible future applications in clinical trials.
- 8 April 2024
- Published by Wiley in Journal of Neuroimaging
- Vol. 34 (4) , 475-485
Open AccessDetection of pathological contrast enhancement with synthetic brain imaging from quantitative multiparametric MRI
Background and Purpose: We aimed to test whether synthetic T1‐weighted imaging derived from a post‐contrast Quantitative Transient‐state Imaging (QTI) acquisition enabled revealing pathological contrast enhancement in intracranial lesions.Methods: The analysis included 141 patients who underwent a 3 Tesla‐MRI brain exam with intravenous contrast media administration, with the post‐contrast acquisition protocol comprising a three‐dimensional fast spoiled gradient echo (FSPGR) sequence and a QTI acquisition. Synthetic T1‐weighted images were generated from QTI‐derived quantitative maps of relaxation times and proton density. Two neuroradiologists assessed synthetic and conventional post‐contrast T1‐weighted images for the presence and pattern of pathological contrast enhancement in intracranial lesions. Enhancement volumes were quantitatively compared.Results: Using conventional imaging as a reference, synthetic T1‐weighted imaging was 93% sensitive in revealing the presence of contrast enhancing lesions. The agreement for the presence/absence of contrast enhancement was almost perfect both between readers (k = 1 for both conventional and synthetic imaging) and between sequences (k = 0.98 for both readers). In 91% of lesions, synthetic T1‐weighted imaging showed the same pattern of contrast enhancement visible in conventional imaging. Differences in enhancement pattern in the remaining lesions can be due to the lower spatial resolution and the longer acquisition delay from contrast media administration of QTI compared to FSPGR. Overall, enhancement volumes appeared larger in synthetic imaging.Conclusions: QTI‐derived post‐contrast synthetic T1‐weighted imaging captures pathological contrast enhancement in most intracranial enhancing lesions. Further comparative studies employing quantitative imaging with higher spatial resolution is needed to support our data and explore possible future applications in clinical trials.
- 16 September 2019
- Published by BMJ in Journal of Neurology, Neurosurgery & Psychiatry
- Vol. 91 (1) , 98-103
Midbrain MRI assessments in progressive supranuclear palsy subtypes
Objectives To explore the role of the available midbrain-based MRI morphometric assessments in (1) differentiating among progressive supranuclear palsy (PSP) subtypes (PSP Richardson’s syndrome (PSP-RS), PSP with predominant parkinsonism (PSP-P) and the other variant syndromes of PSP (vPSP)), and (2) supporting the diagnosis of PSP subtypes compared with Parkinson’s disease (PD) and healthy controls (HC). Methods Seventy-eight patients with PSP (38 PSP-RS, 21 PSP-P and 19 vPSP), 35 PD and 38 HC were included in the present analysis. Available midbrain-based MRI morphometric assessments were calculated for all participants. Results Current MRI midbrain-based assessments do not display an adequate sensitivity and specificity profile in differentiating PSP subtypes. On the other hand, we confirmed MR Parkinsonism Index (MRPI) and pons area to midbrain area ratio (P/M) have adequate diagnostic value to support PSP-RS clinical diagnosis compared with both PD and HC, but low sensitivity and specificity profile in differentiating PSP-P from PD as well as from HC. The same measures show acceptable sensitivity and specificity profile in supporting clinical diagnosis of vPSP versus HC but not versus PD. Similar findings were detected for the newer MRPI and P/M versions. Conclusions Further studies are warranted to identify neuroimaging biomarkers supporting the clinical phenotypic categorisation of patients with PSP. MRPI and P/M have diagnostic value in supporting the clinical diagnosis of PSP-RS. Classification of evidence This study provides class III evidence that available MRI midbrain-based assessments do not have diagnostic value in differentiating the Movement Disorder Society PSP subtypes.
- 16 September 2019
- Published by BMJ in Journal of Neurology, Neurosurgery & Psychiatry
- Vol. 91 (1) , 98-103
Midbrain MRI assessments in progressive supranuclear palsy subtypes
Objectives To explore the role of the available midbrain-based MRI morphometric assessments in (1) differentiating among progressive supranuclear palsy (PSP) subtypes (PSP Richardson’s syndrome (PSP-RS), PSP with predominant parkinsonism (PSP-P) and the other variant syndromes of PSP (vPSP)), and (2) supporting the diagnosis of PSP subtypes compared with Parkinson’s disease (PD) and healthy controls (HC). Methods Seventy-eight patients with PSP (38 PSP-RS, 21 PSP-P and 19 vPSP), 35 PD and 38 HC were included in the present analysis. Available midbrain-based MRI morphometric assessments were calculated for all participants. Results Current MRI midbrain-based assessments do not display an adequate sensitivity and specificity profile in differentiating PSP subtypes. On the other hand, we confirmed MR Parkinsonism Index (MRPI) and pons area to midbrain area ratio (P/M) have adequate diagnostic value to support PSP-RS clinical diagnosis compared with both PD and HC, but low sensitivity and specificity profile in differentiating PSP-P from PD as well as from HC. The same measures show acceptable sensitivity and specificity profile in supporting clinical diagnosis of vPSP versus HC but not versus PD. Similar findings were detected for the newer MRPI and P/M versions. Conclusions Further studies are warranted to identify neuroimaging biomarkers supporting the clinical phenotypic categorisation of patients with PSP. MRPI and P/M have diagnostic value in supporting the clinical diagnosis of PSP-RS. Classification of evidence This study provides class III evidence that available MRI midbrain-based assessments do not have diagnostic value in differentiating the Movement Disorder Society PSP subtypes.
- 1 August 2019
- Published by Elsevier in NeuroImage
- Vol. 197, 557-564
Echo-time dependency of quantitative susceptibility mapping reproducibility at different magnetic field strengths
- 1 August 2019
- Published by Elsevier in NeuroImage
- Vol. 197, 557-564
Echo-time dependency of quantitative susceptibility mapping reproducibility at different magnetic field strengths
- 1 July 2019
- Published by Elsevier in NeuroImage
- Vol. 195, 362-372
Multi-site repeatability and reproducibility of MR fingerprinting of the healthy brain at 1.5 and 3.0 T
- 1 July 2019
- Published by Elsevier in NeuroImage
- Vol. 195, 362-372
Multi-site repeatability and reproducibility of MR fingerprinting of the healthy brain at 1.5 and 3.0 T
- Open Access
- 1 January 2019
- Published by Elsevier in NeuroImage: Clinical
- Vol. 24, 101999
Quantitative susceptibility mapping in atypical Parkinsonisms
- 1 January 2019
- Published by Elsevier in NeuroImage: Clinical
- Vol. 24, 101999
Open AccessQuantitative susceptibility mapping in atypical Parkinsonisms
- Open Access
- 1 January 2019
- Published by Elsevier in NeuroImage: Clinical
- Vol. 24, 101934
MRI cortical feature of bulbar impairment in patients with amyotrophic lateral sclerosis
- 1 January 2019
- Published by Elsevier in NeuroImage: Clinical
- Vol. 24, 101934
Open AccessMRI cortical feature of bulbar impairment in patients with amyotrophic lateral sclerosis
- 1 December 2018
- Published by Elsevier in Psychiatry Research: Neuroimaging
- Vol. 282, 126-131
Functional magnetic resonance imaging with encoding task in patients with mild cognitive impairment and different severity of leukoaraiosis
- 1 December 2018
- Published by Elsevier in Psychiatry Research: Neuroimaging
- Vol. 282, 126-131
Functional magnetic resonance imaging with encoding task in patients with mild cognitive impairment and different severity of leukoaraiosis
- Open Access
- 25 November 2018
- Published by Wiley in Neural Plasticity
- Vol. 2018, 1-11
Potentials of Ultrahigh-Field MRI for the Study of Somatosensory Reorganization in Congenital Hemiplegia
Reorganization of somatosensory function influences the clinical recovery of subjects with congenital unilateral brain lesions. Ultrahigh-field (UHF) functional MRI (fMRI) with the use of a 7 T magnet has the potential to contribute fundamentally to the current knowledge of such plasticity mechanisms. The purpose of this study was to obtain preliminary information on the possible advantages of the study of somatosensory reorganization at UHF fMRI. We enrolled 6 young adults (mean age 25 ± 6 years) with congenital unilateral brain lesions (4 in the left hemisphere and 2 in the right hemisphere; 4 with perilesional motor reorganization and 2 with contralesional motor reorganization) and 7 healthy age-matched controls. Nondominant hand sensory assessment included stereognosis and 2-point discrimination. Task-dependent fMRI was performed to elicit a somatosensory activation by using a safe and quantitative device developed ad hoc to deliver a reproducible gentle tactile stimulus to the distal phalanx of thumb and index fingers. Group analysis was performed in the control group. Individual analyses in the native space were performed with data of hemiplegic subjects. The gentle tactile stimulus showed great accuracy in determining somatosensory cortex activation. Single-subject gentle tactile stimulus showed an S1 activation in the postcentral gyrus and an S2 activation in the inferior parietal insular cortex. A correlation emerged between an index of S1 reorganization (distance between expected and reorganized S1) and sensory deficit ( p < 0.05 ) in subjects with hemiplegia, with higher distance related to a more severe sensory deficit. Increase in spatial resolution at 7 T allows a better localization of reorganized tactile function validated by its correlation with clinical measures. Our results support the S1 early-determination hypothesis and support the central role of topography of reorganized S1 compared to a less relevant S1-M1 integration.
- 25 November 2018
- Published by Wiley in Neural Plasticity
- Vol. 2018, 1-11
Open AccessPotentials of Ultrahigh-Field MRI for the Study of Somatosensory Reorganization in Congenital Hemiplegia
Reorganization of somatosensory function influences the clinical recovery of subjects with congenital unilateral brain lesions. Ultrahigh-field (UHF) functional MRI (fMRI) with the use of a 7 T magnet has the potential to contribute fundamentally to the current knowledge of such plasticity mechanisms. The purpose of this study was to obtain preliminary information on the possible advantages of the study of somatosensory reorganization at UHF fMRI. We enrolled 6 young adults (mean age 25 ± 6 years) with congenital unilateral brain lesions (4 in the left hemisphere and 2 in the right hemisphere; 4 with perilesional motor reorganization and 2 with contralesional motor reorganization) and 7 healthy age-matched controls. Nondominant hand sensory assessment included stereognosis and 2-point discrimination. Task-dependent fMRI was performed to elicit a somatosensory activation by using a safe and quantitative device developed ad hoc to deliver a reproducible gentle tactile stimulus to the distal phalanx of thumb and index fingers. Group analysis was performed in the control group. Individual analyses in the native space were performed with data of hemiplegic subjects. The gentle tactile stimulus showed great accuracy in determining somatosensory cortex activation. Single-subject gentle tactile stimulus showed an S1 activation in the postcentral gyrus and an S2 activation in the inferior parietal insular cortex. A correlation emerged between an index of S1 reorganization (distance between expected and reorganized S1) and sensory deficit ( p < 0.05 ) in subjects with hemiplegia, with higher distance related to a more severe sensory deficit. Increase in spatial resolution at 7 T allows a better localization of reorganized tactile function validated by its correlation with clinical measures. Our results support the S1 early-determination hypothesis and support the central role of topography of reorganized S1 compared to a less relevant S1-M1 integration.
- Open Access
- 9 November 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (1) , 63-69
Semiautomated Evaluation of the Primary Motor Cortex in Patients with Amyotrophic Lateral Sclerosis at 3T
Amyotrophic lateral sclerosis is a neurodegenerative disease involving the upper and lower motor neurons. In amyotrophic lateral sclerosis, pathologic changes in the primary motor cortex include Betz cell depletion and the presence of reactive iron-loaded microglia, detectable on 7T MR images as atrophy and T2*-hypointensity. Our purposes were the following: 1) to investigate the signal hypointensity-to-thickness ratio of the primary motor cortex as a radiologic marker of upper motor neuron involvement in amyotrophic lateral sclerosis with a semiautomated method at 3T, 2) to compare 3T and 7T results, and 3) to evaluate whether semiautomated measurement outperforms visual image assessment. We investigated 27 patients and 13 healthy subjects at 3T, and 19 patients and 18 healthy subjects at 7T, performing a high-resolution 3D multiecho T2*-weighted sequence targeting the primary motor cortex. The signal hypointensity-to-thickness ratio of the primary motor cortex was calculated with a semiautomated method depicting signal intensity profiles of the cortex. Images were also visually classified as "pathologic" or "nonpathologic" based on the primary motor cortex signal intensity and thickness. The signal hypointensity-to-thickness ratio of the primary motor cortex was greater in patients than in controls (P < .001), and it correlated with upper motor neuron impairment in patients (ρ = 0.57, P < .001). The diagnostic accuracy of the signal hypointensity-to-thickness ratio was high at 3T (area under the curve = 0.89) and even higher at 7T (area under the curve = 0.94). The sensitivity of the semiautomated method (0.81) outperformed the sensitivity of the visual assessment (0.56-0.63) at 3T. The signal hypointensity-to-thickness ratio of the primary motor cortex calculated with a semiautomated method is suggested as a radiologic marker of upper motor neuron burden in patients with amyotrophic lateral sclerosis. This semiautomated method may be useful for improving the subjective radiologic evaluation of upper motor neuron pathology in patients suspected of having amyotrophic lateral sclerosis.
- 9 November 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (1) , 63-69
Open AccessSemiautomated Evaluation of the Primary Motor Cortex in Patients with Amyotrophic Lateral Sclerosis at 3T
Amyotrophic lateral sclerosis is a neurodegenerative disease involving the upper and lower motor neurons. In amyotrophic lateral sclerosis, pathologic changes in the primary motor cortex include Betz cell depletion and the presence of reactive iron-loaded microglia, detectable on 7T MR images as atrophy and T2*-hypointensity. Our purposes were the following: 1) to investigate the signal hypointensity-to-thickness ratio of the primary motor cortex as a radiologic marker of upper motor neuron involvement in amyotrophic lateral sclerosis with a semiautomated method at 3T, 2) to compare 3T and 7T results, and 3) to evaluate whether semiautomated measurement outperforms visual image assessment. We investigated 27 patients and 13 healthy subjects at 3T, and 19 patients and 18 healthy subjects at 7T, performing a high-resolution 3D multiecho T2*-weighted sequence targeting the primary motor cortex. The signal hypointensity-to-thickness ratio of the primary motor cortex was calculated with a semiautomated method depicting signal intensity profiles of the cortex. Images were also visually classified as "pathologic" or "nonpathologic" based on the primary motor cortex signal intensity and thickness. The signal hypointensity-to-thickness ratio of the primary motor cortex was greater in patients than in controls (P < .001), and it correlated with upper motor neuron impairment in patients (ρ = 0.57, P < .001). The diagnostic accuracy of the signal hypointensity-to-thickness ratio was high at 3T (area under the curve = 0.89) and even higher at 7T (area under the curve = 0.94). The sensitivity of the semiautomated method (0.81) outperformed the sensitivity of the visual assessment (0.56-0.63) at 3T. The signal hypointensity-to-thickness ratio of the primary motor cortex calculated with a semiautomated method is suggested as a radiologic marker of upper motor neuron burden in patients with amyotrophic lateral sclerosis. This semiautomated method may be useful for improving the subjective radiologic evaluation of upper motor neuron pathology in patients suspected of having amyotrophic lateral sclerosis.