David A. G. Redpath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David A. G. Redpath has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Neil James Hewitt
Ulster University Belfast UK
4 shared publications - Philip Griffiths
Ulster University
4 shared publications - Harjit Singh
Institute of Energy Futures, Brunel University London, Uxbridge UB8 3PH, UK
3 shared publications - Ye Huang
Centre for Sustainable Technologies, Ulster University, Belfast BT15 1AP, UK
3 shared publications M. Anderson
Centre for Sustainable Technologies, University of Ulster, Co Antrim BT37 0QB, Northern Ireland, U.K.
2 shared publicationsPhilip Dalzell
Centre for Sustainable Technologies , University of Ulster at Jordanstown , Newtownabbey, Co. Antrim BT38 9QB , UK
2 shared publications
Latest Publications
- Open Access
- 15 September 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (18) , 11549
Design of a Building-Scale Space Solar Cooling System Using TRNSYS
Research into solar absorption chillers despite their environmental benefits has been limited to date to mainly larger systems whilst ignoring smaller building-scale units, which can significantly benefit from the use of optimally designed, low concentrating, non-imaging optical reflectors. A solar absorption chiller system designed to provide year-round space cooling for a typical primary health care facility in Cairo, Egypt, was designed to match local ambient, solar, and occupancy conditions, its performance simulated and then optimized to minimize auxiliary power consumption using the TRNSYS18 software, TRNOPT. Different configurations of collector types, array areas, storage sizes and collector slopes were used to determine the optimum specifications for the system components. Non-concentrating Evacuated Tube Collectors (ETCs) were compared with the same Evacuated Tube Collectors but integrated with external Compound Parabolic Concentrators (CPCs) with a geometric concentration ratio of 1.5X for supplying thermal energy to the single-effect absorption chiller investigated. This paper describes a user-friendly methodology developed for the design of solar heat-powered absorption chillers for small buildings using TRNSYS18 employing the Hookes–Jeeves algorithm within the TRNOPT function. Clear steps to avoid convergence problems when using TRNSYS are articulated to make repeatability for different systems and locations more straightforward. Collector array areas were varied from 30 m2 to 160 m2 and the size of the water-based thermal storage from 1 m3 to 3 m3 to determine the configuration that can supply the maximum solar fraction of the building’s cooling requirements for the lowest lifetime cost. The optimum solar fraction for ETCs and CPCs was found to be 0.66 and 0.94, respectively. If the current air conditioning demand is met through adoption of the CPC-based solar absorption systems this can potentially save the emission of 3,966,247 tCO2 per annum.
- 15 September 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (18) , 11549
Open AccessDesign of a Building-Scale Space Solar Cooling System Using TRNSYS
Research into solar absorption chillers despite their environmental benefits has been limited to date to mainly larger systems whilst ignoring smaller building-scale units, which can significantly benefit from the use of optimally designed, low concentrating, non-imaging optical reflectors. A solar absorption chiller system designed to provide year-round space cooling for a typical primary health care facility in Cairo, Egypt, was designed to match local ambient, solar, and occupancy conditions, its performance simulated and then optimized to minimize auxiliary power consumption using the TRNSYS18 software, TRNOPT. Different configurations of collector types, array areas, storage sizes and collector slopes were used to determine the optimum specifications for the system components. Non-concentrating Evacuated Tube Collectors (ETCs) were compared with the same Evacuated Tube Collectors but integrated with external Compound Parabolic Concentrators (CPCs) with a geometric concentration ratio of 1.5X for supplying thermal energy to the single-effect absorption chiller investigated. This paper describes a user-friendly methodology developed for the design of solar heat-powered absorption chillers for small buildings using TRNSYS18 employing the Hookes–Jeeves algorithm within the TRNOPT function. Clear steps to avoid convergence problems when using TRNSYS are articulated to make repeatability for different systems and locations more straightforward. Collector array areas were varied from 30 m2 to 160 m2 and the size of the water-based thermal storage from 1 m3 to 3 m3 to determine the configuration that can supply the maximum solar fraction of the building’s cooling requirements for the lowest lifetime cost. The optimum solar fraction for ETCs and CPCs was found to be 0.66 and 0.94, respectively. If the current air conditioning demand is met through adoption of the CPC-based solar absorption systems this can potentially save the emission of 3,966,247 tCO2 per annum.
- 9 June 2015
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 36 (6) , 517-530
An investigation into the potential of low head hydro power in Northern Ireland for the production of electricity
The maximum exploitable potential for low head hydroelectric sites (gross head≤10 m) in Northern Ireland (NI) was determined as 12.07 MW using a simple payback analysis for 304 potential sites investigated to derive a classification scheme in terms of economic viability. A techno-economic analysis with validated numerical models from previous research estimated the capital investment required for the development of a hydroelectric plant, using the low head Michell-Banki cross flow turbine, for the 304 sites investigated. The number of potentially viable sites in NI for low head hydro ranged from 198 to 286 with an estimated installed capacity ranging from 11.95 to 12.05 MW. Sites with a limited installed capacity were not economically viable unless increased government support in the form of longer term (25–50 years) low interest loans as well as the current (Renewables Obligations Certificates) Renewables Obligation Certificates scheme is provided and sustained.
- 9 June 2015
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 36 (6) , 517-530
An investigation into the potential of low head hydro power in Northern Ireland for the production of electricity
The maximum exploitable potential for low head hydroelectric sites (gross head≤10 m) in Northern Ireland (NI) was determined as 12.07 MW using a simple payback analysis for 304 potential sites investigated to derive a classification scheme in terms of economic viability. A techno-economic analysis with validated numerical models from previous research estimated the capital investment required for the development of a hydroelectric plant, using the low head Michell-Banki cross flow turbine, for the 304 sites investigated. The number of potentially viable sites in NI for low head hydro ranged from 198 to 286 with an estimated installed capacity ranging from 11.95 to 12.05 MW. Sites with a limited installed capacity were not economically viable unless increased government support in the form of longer term (25–50 years) low interest loans as well as the current (Renewables Obligations Certificates) Renewables Obligation Certificates scheme is provided and sustained.
- Open Access
- 5 February 2014
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 10 (3) , 283-287
Investigation of concentrating and nonconcentrating evacuated tube solar water heaters using 2D particle imaging velocimetry
Under transient climatic conditions, solar water heaters using heat pipes are more effective at capturing incident solar radiation than other equivalent sized solar water heaters. The cost must be reduced to improve uptake of such systems. To investigate two methods were considered by this study: thermosyphon fluid flow and reflective concentrators. A physical reconfigurable laboratory model of the manifold and associated condensers of a heat-pipe-evacuated tube system were fabricated; fluid circulation was via thermosyphonic action, particle imaging velocimetry derived velocity maps and the use of concentrators was simulated. When condenser spacing was doubled, the Nusselt number increased by 43%, the velocity by 55% but the heat transfer efficiency of the model manifold decreased by 9%. Potential annual energy savings of 10 207 GWh could be realized if such systems could be successfully fabricated.
- 5 February 2014
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 10 (3) , 283-287
Open AccessInvestigation of concentrating and nonconcentrating evacuated tube solar water heaters using 2D particle imaging velocimetry
Under transient climatic conditions, solar water heaters using heat pipes are more effective at capturing incident solar radiation than other equivalent sized solar water heaters. The cost must be reduced to improve uptake of such systems. To investigate two methods were considered by this study: thermosyphon fluid flow and reflective concentrators. A physical reconfigurable laboratory model of the manifold and associated condensers of a heat-pipe-evacuated tube system were fabricated; fluid circulation was via thermosyphonic action, particle imaging velocimetry derived velocity maps and the use of concentrators was simulated. When condenser spacing was doubled, the Nusselt number increased by 43%, the velocity by 55% but the heat transfer efficiency of the model manifold decreased by 9%. Potential annual energy savings of 10 207 GWh could be realized if such systems could be successfully fabricated.
- 1 December 2013
- Published by Elsevier in Applied Energy
- Vol. 112, 396-404
A technical and economic analysis of three large scale biomass combustion plants in the UK
- 1 December 2013
- Published by Elsevier in Applied Energy
- Vol. 112, 396-404
A technical and economic analysis of three large scale biomass combustion plants in the UK
- Open Access
- 9 July 2012
- Published by Scientific and Academic Publishing in Energy and Power
- Vol. 2 (4) , 46-50
An Experimental Comparison of two Solar Photovoltaic- Thermal (PVT) Energy Conversion Systems for Production of Heat and Power
Two solar photovoltaic-thermal (PVT) energy conversion systems are described and their performance tested under laboratory conditions. One of these was a simple Flat Plate (FP-PVT) design, with headers and risers for heat removal the other a fixed linear axis Compound Parabolic Concentrating solar PVT (CPC-PVT) energy conversion system with a heat-pipe for removal of solar gain. Both had a low iron glass cover for high transmissivity of solar radiation, and polycrystalline silicon solar photovoltaic cells adhered to the absorber. Heat loss coefficient for the FP-PVT collector was measured as 4.1W/m 2 /K and 3.5W/m 2 /K for the CPC-PVT solar collector. These solar collectors were tested under steady state conditions using the solar simulator facility at the University of Ulster's Centre for Sustainable Technologies. The FP-PVT and the CPC-PVT had a combined efficiency of 66.8% and 53.4% respectively producing both heat and power.
- 9 July 2012
- Published by Scientific and Academic Publishing in Energy and Power
- Vol. 2 (4) , 46-50
Open AccessAn Experimental Comparison of two Solar Photovoltaic- Thermal (PVT) Energy Conversion Systems for Production of Heat and Power
Two solar photovoltaic-thermal (PVT) energy conversion systems are described and their performance tested under laboratory conditions. One of these was a simple Flat Plate (FP-PVT) design, with headers and risers for heat removal the other a fixed linear axis Compound Parabolic Concentrating solar PVT (CPC-PVT) energy conversion system with a heat-pipe for removal of solar gain. Both had a low iron glass cover for high transmissivity of solar radiation, and polycrystalline silicon solar photovoltaic cells adhered to the absorber. Heat loss coefficient for the FP-PVT collector was measured as 4.1W/m 2 /K and 3.5W/m 2 /K for the CPC-PVT solar collector. These solar collectors were tested under steady state conditions using the solar simulator facility at the University of Ulster's Centre for Sustainable Technologies. The FP-PVT and the CPC-PVT had a combined efficiency of 66.8% and 53.4% respectively producing both heat and power.
- 1 February 2012
- Published by Elsevier in Solar Energy
- Vol. 86 (2) , 705-715
Thermosyphon heat-pipe evacuated tube solar water heaters for northern maritime climates
- 1 February 2012
- Published by Elsevier in Solar Energy
- Vol. 86 (2) , 705-715
Thermosyphon heat-pipe evacuated tube solar water heaters for northern maritime climates
- 1 November 2011
- Published by Elsevier in Journal of Cleaner Production
- Vol. 19 (17-18) , 2034-2048
Battery powered electric vehicles charged via solar photovoltaic arrays developed for light agricultural duties in remote hilly areas in the Southern Mediterranean region
- 1 November 2011
- Published by Elsevier in Journal of Cleaner Production
- Vol. 19 (17-18) , 2034-2048
Battery powered electric vehicles charged via solar photovoltaic arrays developed for light agricultural duties in remote hilly areas in the Southern Mediterranean region
- 25 January 2011
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 35 (12) , 1037-1047
A techno-economic analysis of biomass gasifiers integrated with high and intermediate temperature solid oxide fuel cells
In this paper the ECLIPSE process simulation package is used to model and make a techno‐economic analysis of a range of systems that combine biomass gasification with SOFC stacks. Two forms of the SOFC are considered: the intermediate temperature (IT) solid oxide fuel cell and the standard high‐temperature solid oxide fuel cell. The biomass gasification technology, which was selected for integration with the SOFC stacks, was the air‐blown downdraught gasifier, because of its simplicity and relative cheapness. Willow and miscanthus were taken as the biomass fuels for the power plants. In addition, the sensitivity of the COE to variations in the fuel cost, the fuel cell cost, the fuel cell lifetime, and the waste heat selling price were examined and compared. From the ECLIPSE simulations, the efficiencies of both the HT and IT 250 kWe systems were found to be around 39% when willow was used as fuel and around 38% with miscanthus, the difference being due to moisture content, rather than any intrinsic property of the biomass. Similarly, for the 25‐kWe systems, the efficiencies were found to be around 35 and 34% respectively. These values are higher than for any other biomass‐fired electricity generation technologies of similar scale. Copyright © 2011 John Wiley & Sons, Ltd.
- 25 January 2011
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 35 (12) , 1037-1047
A techno-economic analysis of biomass gasifiers integrated with high and intermediate temperature solid oxide fuel cells
In this paper the ECLIPSE process simulation package is used to model and make a techno‐economic analysis of a range of systems that combine biomass gasification with SOFC stacks. Two forms of the SOFC are considered: the intermediate temperature (IT) solid oxide fuel cell and the standard high‐temperature solid oxide fuel cell. The biomass gasification technology, which was selected for integration with the SOFC stacks, was the air‐blown downdraught gasifier, because of its simplicity and relative cheapness. Willow and miscanthus were taken as the biomass fuels for the power plants. In addition, the sensitivity of the COE to variations in the fuel cost, the fuel cell cost, the fuel cell lifetime, and the waste heat selling price were examined and compared. From the ECLIPSE simulations, the efficiencies of both the HT and IT 250 kWe systems were found to be around 39% when willow was used as fuel and around 38% with miscanthus, the difference being due to moisture content, rather than any intrinsic property of the biomass. Similarly, for the 25‐kWe systems, the efficiencies were found to be around 35 and 34% respectively. These values are higher than for any other biomass‐fired electricity generation technologies of similar scale. Copyright © 2011 John Wiley & Sons, Ltd.
- 1 July 2010
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 31 (3) , 115-132
Battery powered electric vehicles developed for light agricultural duties in remote areas in the southern Mediterranean region
Hilly and remote areas in the Southern Mediterranean region suffer a high cost of diesel fuel, problematic supply, poor or non-existent grid connections and lack of maintenance technicians to service farm grid generation systems and machinery. A prototype battery powered electric vehicle using a solar photovoltaic array (10 kWp) was installed at a monastery situated at Achkout (Lebanon) with a total agricultural area of 50 hectares, 10 hectares of which was under viticulture. The monastery and associated farmland previously relied on a diesel powered generator (35 kVA) and a diesel fuelled tractor (20 kW) for meeting electrical loads and motive power. This prototype battery powered electric vehicle or Renewable Energy Agricultural Multipurpose System (RAMseS) for Farmers has been developed under the European Union's FP6 programme to investigate the potential for the cleaner production of power, hence reducing the use of diesel fuels in agriculture. Data collected from the test site is presented. An economic analysis determined that if the current trends in inflation in the EU continue and fuel costs increase by 10% per annum, then the original RAMseS system will be economically viable. A further analysis looking at the adoption of new lithium titanate batteries reveals that these systems would be cost effective if these new batteries can be produced at a similar cost to lead acid batteries. Adoption of the RAMseS system for a 10 hectare vineyard would result in annual fuel and carbon dioxide saving of 4000 litres and 2.9 tonnes respectively. The use of alternative non-lead based batteries would save the use of nearly 21 tonnes of lead over the system's lifetime.
- 1 July 2010
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 31 (3) , 115-132
Battery powered electric vehicles developed for light agricultural duties in remote areas in the southern Mediterranean region
Hilly and remote areas in the Southern Mediterranean region suffer a high cost of diesel fuel, problematic supply, poor or non-existent grid connections and lack of maintenance technicians to service farm grid generation systems and machinery. A prototype battery powered electric vehicle using a solar photovoltaic array (10 kWp) was installed at a monastery situated at Achkout (Lebanon) with a total agricultural area of 50 hectares, 10 hectares of which was under viticulture. The monastery and associated farmland previously relied on a diesel powered generator (35 kVA) and a diesel fuelled tractor (20 kW) for meeting electrical loads and motive power. This prototype battery powered electric vehicle or Renewable Energy Agricultural Multipurpose System (RAMseS) for Farmers has been developed under the European Union's FP6 programme to investigate the potential for the cleaner production of power, hence reducing the use of diesel fuels in agriculture. Data collected from the test site is presented. An economic analysis determined that if the current trends in inflation in the EU continue and fuel costs increase by 10% per annum, then the original RAMseS system will be economically viable. A further analysis looking at the adoption of new lithium titanate batteries reveals that these systems would be cost effective if these new batteries can be produced at a similar cost to lead acid batteries. Adoption of the RAMseS system for a 10 hectare vineyard would result in annual fuel and carbon dioxide saving of 4000 litres and 2.9 tonnes respectively. The use of alternative non-lead based batteries would save the use of nearly 21 tonnes of lead over the system's lifetime.