JYJunya Yoshitani

Junya Yoshitani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Junya Yoshitani has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Association between preoperative radiographic osteoarthritis severity and patient-reported outcomes after total hip arthroplasty: a systematic review and meta-analysis

    by Junya Yoshitani, Joseph Dulleston, Amir Reza Rafati Fard, Mihir Gajre, Vikas Khanduja

    Purpose: Although total hip arthroplasty (THA) reliably improves pain and function in patients with hip osteoarthritis (OA), a subset of patients experience limited postoperative benefit. The association between preoperative radiographic OA severity and postoperative patient-reported outcomes (PROMs) remains controversial. Methods: We performed a systematic review and meta-analysis according to PRISMA guidelines. Electronic databases (MEDLINE, Embase, and Cochrane Library) were searched for studies comparing postoperative PROMs after primary THA between patients with moderate versus severe radiographic OA. The primary outcome was postoperative PROMs at approximately 12 ± six months. Random-effects meta-analyses were conducted using standardized mean differences (SMDs). Adjusted continuous and responder outcomes, complications, and sensitivity analyses were also evaluated. Results: Eighteen observational studies (9,235 patients) were included. Severe radiographic OA showed statistically significant but modest advantages in function (SMD − 0.34; 95% CI − 0.62 to − 0.07; I 2 = 83%) and health-related quality of life (HRQoL; SMD − 0.33; 95% CI − 0.54 to − 0.11; I 2 = 70%), while pain did not differ (SMD − 0.14; 95% CI − 0.51 to 0.22; I 2 = 79%). Substantial heterogeneity limits confidence in these estimates. Adjusted analyses showed a mean difference of − 4.0 points on function scales and 49% lower odds of a clinically meaningful response in the moderate group (OR 0.51; 95% CI 0.36–0.72). No statistically detectable differences in complication rates were observed. Conclusion: Greater preoperative radiographic OA severity was associated with statistically significant but modest advantages in postoperative function and HRQoL, whereas pain relief was comparable across severity groups. Although patients with moderate OA may experience symptomatic improvement, their likelihood of achieving a clinically meaningful response appears lower. These findings support careful patient selection, realistic expectation-setting, and thorough evaluation of pain sources before proceeding to THA.

  • Floor and ceiling effects of the international hip outcome tool-12 in patients undergoing hip preservation surgery: A national registry study

    by Seper Ekhtiari, Junya Yoshitani, Justin Green, Ajay Malviya, Vikas Khanduja

    Introduction Validated patient-reported outcome measures (PROMs) play a crucial role in assessing the outcome of any intervention, including hip preservation surgery. This study aims to evaluate floor and ceiling effects, which indicate data capture limitations, of the International Hip Outcome Tool-12 (iHOT-12) in patients undergoing hip preservation surgery. Methods Data from the UK's Non-Arthroplasty Hip Registry (NAHR) were analyzed. Patient demographics, surgical details, and iHOT-12 scores were collected. Floor and ceiling effects were assessed using three definitions: absolute minimum or maximum scores, scores within 10% of the minimum or maximum, and scores within one minimal clinically important difference (MCID) of the minimum or maximum. Analyses were performed for patients undergoing hip arthroscopy and periacetabular osteotomy (PAO), as well as for male and female subgroups and by iHOT-12 domain. Results 8,408 patients (7,081 hip arthroscopy, 1,327 PAO) were included. At 26 to 52 weeks, a ceiling effect was observed in 15–22% of patients, indicating limited data capture. A floor effect was present in 9–15% of patients at baseline indicating possible limited data capture in pre-operative patients. Male and female patients had similar ceiling effects at 52 weeks, but females exhibited a higher risk of a floor effect at baseline. The sport and recreational domain was most susceptible to floor effects at baseline, and the job-related concerns domain was most susceptible to ceiling effects at follow-up. Conclusions The study demonstrates the presence of floor and ceiling effects in the iHOT-12 for patients undergoing hip preservation surgery. The floor and ceiling effects were similar between patients undergoing hip arthroscopy or PAO. The study also suggests that some patients may experience greater improvement than reflected in post-operative iHOT-12 scores. Future research should focus on identifying patients at risk of floor and ceiling effects and explore modifications to PROMs to enhance their accuracy and utility.

  • Open Access

    The trajectory of patient‐reported outcomes after hip preservation surgery: A National Registry Study

    by Junya Yoshitani, Seper Ekhtiari, Ajay Malviya, Vikas Khanduja

    Purpose: Understanding the trajectory of postoperative patient‐reported outcomes after hip preservation surgery is essential. This study aims to analyse patient‐reported outcome trajectories up to 2 years post‐surgery using the UK's national hip preservation registry and to examine the influence of potential confounders. Methods: Patients who underwent hip arthroscopy or periacetabular osteotomy with preoperative International Hip Outcome Tool‐12 (iHOT‐12) scores and at least two follow‐up measurements at 6 months, 1 year, or 2 years were included from the UK Non‐Arthroplasty Hip Registry. iHOT‐12 score trajectories were analysed, and Latent Growth Curve Modelling was used to identify predictors of these trajectories. Results: Overall 9845 patients were included in this study. 7081 patients underwent a hip arthroscopy, and 1327 patients underwent a periacetabular osteotomy. For hip arthroscopy, there were significant improvements in the iHOT‐12 scores from baseline to 6 months, but no significant change from 6 months to 1 year. However, there was a decrease in the minimal clinically important difference from 1 to 2 year. For periacetabular osteotomy, there were significant improvements in the iHOT‐12 scores from baseline to 6 months, but no significant change from 6 months to 1 year, and from 1 to 2 years. Latent Growth Curve Modelling showed that body mass index (BMI) and sex had a significant impact on pre‐operative iHOT‐12 scores, while age and sex significantly influenced the recovery slope. Conclusions: Patients who underwent hip preservation surgery exhibited significant improvement in iHOT‐12 scores, surpassing the minimal clinically important difference at 6 months postoperatively. This improvement plateaued by 2 years, with a slight decline in scores between 1 and 2 years following hip arthroscopy, though the decrease remained within the clinically meaningful range. BMI, age and sex influenced score trajectories, highlighting the importance of setting patient expectations pre‐operatively. Trial Registration: The UK's Non‐Arthroplasty Hip Registry https://www.nahr.co.uk/ . Level of Evidence: Level III.


  • THE TRAJECTORY OF PATIENT-REPORTED OUTCOMES AFTER HIP PRESERVATION SURGERY: A NATIONAL REGISTRY STUDY

    by Junya Yoshitani, Ajay Malviya, Vikas Khanduja

    Understanding the trajectory of postoperative patient-reported outcomes after hip preservation surgery is essential. This study is the first to analyse patient-reported outcome trajectories up to two years post-surgery using the UK's national hip preservation registry and to examine potential confounders’ influence.Patients who underwent hip arthroscopy or periacetabular osteotomy with preoperative iHOT-12 scores and at least two follow-up measurements at 6 months, 1 year, or 2 years were included from the UK Non-Arthroplasty Hip Registry. iHOT-12 score trajectories were analysed, and Latent Growth Curve Modelling was used to identify predictors of these trajectories.Overall, 9,845 patients were included in this study. 7,081 patients underwent a hip arthroscopy, and 1,327 patients underwent a periacetabular osteotomy. For hip arthroscopy, there were significant improvements in the iHOT-12 scores from baseline to 6 months [32.2 to 58.2], but no significant change from 6 months to 1 year [mean: 58.0]. However, there was a decrease in the minimal clinically important difference from 1 year to 2 years [mean: 51.7]. For periacetabular osteotomy, there were significant improvements in the iHOT-12 scores from baseline to 6 months [31.7 to 56.0], but no significant change from 6 months to 1 year [55.4], and from 1 year to 2 years [51.3]. Latent Growth Curve Modelling showed that BMI and sex had a significant impact on pre-operative iHOT-12 scores, while age and sex significantly influenced the recovery slope.Patients who underwent hip preservation surgery exhibited significant improvement in iHOT-12 scores, surpassing the minimal clinically important difference at six months postoperatively. This improvement plateaued by two years, with a slight decline in scores between one and two years following hip arthroscopy, though the decrease remained within the clinically meaningful range. BMI, age, and sex influenced score trajectories, highlighting clear preoperative communication with patients.

  • UTILITY OF BIOMARKERS FOR FEMOROACETABULAR IMPINGEMENT: A SYSTEMATIC REVIEW

    by Junya Yoshitani, Ajay Malviya, Vikas Khanduja

    Early diagnosis is crucial for effectively treating femoroacetabular impingement (FAI). Molecular biomarkers could improve the diagnosis and prognostication of patients with FAI at risk of developing hip osteoarthritis. This systematic review aimed to assess the utility of biomarkers associated with FAI for diagnostic purposes and as tools for predicting disease progression. The research questions addressed were: (1) which biomarkers are effective for the diagnosis or screening of FAI? and (2) which biomarkers can predict disease progression in FAI?A systematic review using the PRISMA guidelines was conducted to investigate the relationship between biomarkers and FAI. The protocol for the review has been published in PROSPERO. Literature search was performed using three databases: Embase, MEDLINE, and Cochrane Library. The initial search yielded 683 articles of which 16 articles were included for final analysis.Data from a total of 2,134 participants were analysed. Sixty-eight unique biomarkers associated with FAI were identified and measured. Diagnostically, 19 biomarkers were identified of which 12 could significantly detect a difference between patients with FAI and healthy controls. 42 biomarkers predicting the association of FAI with hip osteoarthritis or late FAI were identified, of which 16 biomarkers were statistically significant. Only, 4aminobutyrate aminotransferase promoter (ABAT) and peroxisome proliferator-activated receptor gamma (PPARγ) were associated with both diagnosis and prognosis.Biomarkers can help with the diagnosis and identifying disease progression of FAI. A total of 12 biomarkers are useful for detecting early changes in FAI and there are 16 biomarkers which could help with predicting progression to osteoarthritis. However further characterization is required to narrow down the number of biomarkers in each group to demonstrate utility in routine clinical practice. ABAT and PPARγ are associated with both diagnosis and predicting disease progression of FAI.

  • Comparison of Implant Placement Accuracy Between Manual, Robot-Assisted, Computer-Navigated, Augmented Reality Navigated, Patient-Specific Instrumentation, and Accelerometer Navigated Total Hip Arthroplasty

    by Takanori Miura, Norio Yamamoto, Akihiro Shiroshita, Takahiro Tsuge, Akihiro Saitsu, Junya Yoshitani, Shuri Nakao, Ken Takami

    Background: Malpositioning of the acetabular cup during total hip arthroplasty (THA) can lead to complications. Robotic surgery and navigation techniques aim to address this issue, but there is limited evidence regarding which method can achieve better clinical outcomes. Therefore, this network meta-analysis (NMA) aimed to compare the efficacy of various navigation methods. Methods: This NMA of prospective randomized controlled trials compared robot-assisted systems (RAS), computer-assisted navigation systems (CAS), augmented reality-based portable navigation (AR), patient-specific instrumentation (PSI), portable accelerometer-based navigation (PN), and conventional methods (C) for THA procedures. We searched MEDLINE, EMBASE, Cochrane, Central Register of Controlled Trials, International Clinical Trials Platform Search Portal, and ClinicalTrials.gov. databases. The primary outcomes included revision surgery and postoperative clinical scores, and the secondary outcomes encompassed cup placement accuracy, acetabular cup placement outliers from the Lewinnek safe zone, surgical time, and complications. We used a Bayesian random-effects NMA, and confidence of evidence was assessed using confidence in NMA. Results: We identified 45 studies including 2,122 patients. We did not find large differences in revision surgery, clinical outcome scores, cup inclination, or anteversion angle accuracy among the modalities. AR, CAS, and PSI exhibited a lower risk of outliers from safe zones than C. In addition, RAS and CAS had a longer surgical time than C. Conclusions: Robotic and navigation tools did not reduce the revision risk or enhance clinical outcomes. AR, CAS, PSI, and PN may decrease the risk of cup placement outliers in safe zones. However, the cup placement accuracy was equivalent, and the surgical time may be longer in RAS and CAS than in C. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Current concepts in the diagnosis and management of Os Acetabuli

    by Junya Yoshitani, Benjamin Schoyer, Anand Shah, Vikas Khanduja

    Purpose: The aim of this review is to appraise the current evidence on the epidemiology, pathophysiology, diagnosis and management of os acetabuli. Methods: A scoping review was conducted according to the Joanna Briggs Institute guidelines. A systematic search was performed on Medline (PubMed), Embase and Cochrane Library. Inclusion criteria comprised observational and interventional studies and review articles published in the English language that focused on patients with os acetabuli according to the PRISMA extension of scoping reviews checklist using the terms ‘Os Acetabuli’ or ‘os acetabula’ or ‘acetabular ossicles’. A narrative synthesis of results was undertaken, and the included articles were divided into (i) definition, (ii) aetiology, (iii) diagnosis and imaging and (iv) management of os acetabuli. Results: 107 articles were screened, with 22 meeting the eligibility criteria. A total of 8836 patients were considered, of which 604 had os acetabuli. The mean age was 32.8 years. The prevalence of os acetabuli ranged from 3.4 to 7.7%, with a higher prevalence in males compared to females. True os acetabuli was defined as an unfused secondary ossification centre along the acetabular rim. The aetiology of os acetabuli is thought to be secondary to acetabular dysplasia and/or femoroacetabular impingement. Standard of care for management of symptomatic os acetabuli is considered to be arthroscopic excision unless the excision results in acetabular undercoverage and/or instability, in which case, fixation is recommended. Conclusions: Successful management of os acetabuli depends on understanding the pathology and treating the underlying cause rather than treating the os acetabuli in isolation. Future work needs to focus on establishing clear diagnostic criteria, consensus on definition and an evidence-based treatment algorithm.


  • The conundrum in the measurement of femoral anteversion for young adults with hip pathology

    by Junya Yoshitani, Karadi H. Sunil Kumar, Seper Ekhtiari, Vikas Khanduja

    The conundrum in the measurement of femoral anteversion for young adults with hip pathology


  • Open Access

    Antibacterial Activity in Iodine-coated Implants Under Conditions of Iodine Loss: Study in a Rat Model Plus In Vitro Analysis

    by Ken Ueoka, Tamon Kabata, Masaharu Tokoro, Yoshitomo Kajino, Daisuke Inoue, Tomoharu Takagi, Takaaki Ohmori, Junya Yoshitani, Takuro Ueno, Yuki Yamamuro, et al.

    Background: We developed iodine-coated titanium implants to suppress microbial activity and prevent periprosthetic joint infection (PJI); their efficacy was demonstrated in animal and in vitro models. The iodine content in iodine-coated implants naturally decreases in vivo. However, to our knowledge, the effect of reduced iodine content on the implant’s antimicrobial activity has not been evaluated to date. Questions/purposes: (1) How much does the iodine content on the implant surface decrease after 4 and 8 weeks in vivo in a rat model? (2) What effect does the reduced iodine content have on the antimicrobial effect of the implant against multiple bacteria in an in vitro model? Methods: This experiment was performed in two parts: an in vivo experiment to determine attenuation of iodine levels over time in rats, and an in vitro experiment in which we sought to assess whether the reduced iodine content observed in the in vivo experiment was still sufficient to deliver antimicrobial activity against common pathogens seen in PJI. For the in vivo experiment, three types of titanium alloy washers were implanted in rats: untreated (Ti), surface-anodized to produce an oxide film (Ti-O), and with an iodine layer on the oxidation film (Ti-I). The attenuation of iodine levels in rats was measured over time using inductively coupled plasma-mass spectrometry. Herein, only the Ti-I washer was used, with five implanted in each rat that were removed after 4 or 8 weeks. For the 4- and 8-week models, two rats and 15 washers were used. For the in vitro study, to determine the antibacterial effect, three types of washers (Ti, Ti-O, and Ti-I) (nine washers in total) were implanted in each rat. Then, the washers were removed and the antibacterial effect of each washer was examined on multiple bacterial species using the spread plate method and fluorescence microscopy. For the spread plate method, six rats were used, and five rats were used for the observation using fluorescence microscopy; further, 4- and 8-week models were made for each method. Thus, a total of 22 rats and 198 washers were used. Live and dead bacteria in the biofilm were stained, and the biofilm coverage percentage for quantitative analysis was determined using fluorescence microscopy in a nonblinded manner. Ti-I was used as the experimental group, and Ti and Ti-O were used as control groups. The total number of rats and washers used throughout this study was 24 and 213, respectively. Results: Iodine content in rats implanted with Ti-I samples decreased to 72% and 65% after the in vivo period of 4 and 8 weeks, respectively (p = 0.001 and p < 0.001, respectively). In the in vitro experiment, the Ti-I implants demonstrated a stronger antimicrobial activity than Ti and Ti-O implants in the 4- and 8-week models. Both the median number of bacterial colonies and the median biofilm coverage percentage with live bacteria on Ti-I were lower than those on Ti or Ti-O implants for each bacterial species in the 4- and 8-week models. There was no difference in the median biofilm coverage percentage of dead bacteria. In the 8-week model, the antibacterial activity using the spread plate method had median (interquartile range) numbers of bacteria on the Ti, Ti-O, and Ti-I implants of 112 (104 to 165) × 105, 147 (111 to 162) × 105, and 55 (37 to 67) × 105 of methicillin-sensitive Staphylococcus aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.009); 71 (39 to 111) × 105, 50 (44 to 62) × 105, and 26 (9 to 31)× 105 CFU of methicillin-resistant S. aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.034); and 77 (74 to 83) × 106, 111 (95 to 117) × 106, and 30 (21 to 45) × 106 CFU of Pseudomonas aeruginosa (Ti-I versus Ti, p = 0.004; Ti-I versus Ti-O, p = 0.009). Despite the decrease in the iodine content of Ti-I after 8 weeks, it demonstrated better antibacterial activity against all tested bacteria than the Ti and Ti-O implants. Conclusion: Iodine-coated implants retained their iodine content and antibacterial activity against methicillin-sensitive S. aureus, methicillin-resistant S. aureus, and P. aeruginosa for 8 weeks in vivo in rats. To evaluate the longer-lasting antibacterial efficacy, further research using larger infected animal PJI models with implants in the joints of both males and females is desirable. Clinical Relevance: Iodine-coated titanium implants displayed an antibacterial activity for 8 weeks in rats in vivo. Although the findings in a rat model do not guarantee efficacy in humans, they represent an important step toward clinical application.


  • The feasibility of iodine-supported processing for titanium with different surfaces

    by Ken Ueoka, Yoshitomo Kajino, Tamon Kabata, Daisuke Inoue, Junya Yoshitani, Takuro Ueno, Yuki Yamamuro, Toshiharu Shirai, Hiroyuki Tsuchiya