CDChristine Mary Dzialo

Christine Mary Dzialo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christine Mary Dzialo has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Methodology to Evaluate the Effects of Kinematic Measurement Uncertainties on Knee Ligament Properties Estimated From Laxity Measurements

    by Michael Skipper Andersen, Christine Mary Dzialo, Marco Antonio Marra, Dennis Pedersen

    Ligaments are important joint stabilizers but assessing their mechanical properties remain challenging. We developed a methodology to investigate the effects of kinematic measurement uncertainty during laxity tests on optimization-based estimation of ligament properties. We applied this methodology to a subject-specific knee model with known ligament properties as inputs and compared the estimated to the known knee ligament properties under the influence of noise. Four different sets of laxity tests were simulated with an increasing number of load cases, capturing anterior/posterior, varus/valgus, and internal/external rotation loads at 0 deg and 30 deg of knee flexion. 20 samples of uniform random noise ([−0.5,0.5] mm and degrees) were added to each set and fed into an optimization routine that subsequently estimated the ligament properties based on the noise targets. We found a large range of estimated ligament properties (stiffness ranges of 5.97 kN, 7.64 kN, 8.72 kN, and 3.86 kN; reference strain ranges of 3.11%, 2.53%, 1.88%, and 1.58% for anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medical collateral ligament (MCL), and lateral collateral ligament (LCL), respectively) for three sets of laxity tests, including up to 22 load cases. A set of laxity tests with 60 load cases kept the stiffness and reference strain ranges below 470 N per unit strain and 0.85%, respectively. These results illustrate that kinematic measurement noise have a large impact on estimated ligament properties and we recommend that future studies assess and report both the estimated ligament properties and the associated uncertainties due to kinematic measurement noise.


  • Evaluation of predicted patellofemoral joint kinematics with a moving-axis joint model

    by C.M. Dzialo, P.H. Pedersen, K.K. Jensen, M. de Zee, M.S. Andersen

    The main objectives of this study were to expand the moving-axis joint model concept to the patellofemoral joint and evaluate the patellar motion against experimental patellofemoral kinematics. The experimental data was obtained through 2D-to-3D bone reconstruction of EOS images and segmented MRI data utilizing an iterative closest point optimization technique. Six knee model variations were developed using the AnyBody Modeling System and subject-specific bone geometries. These models consisted of various combinations of tibiofemoral (hinge, moving-axis, and interpolated) and patellofemoral (hinge and moving-axis) joint types. The newly introduced interpolated tibiofemoral joint is calibrated from the five EOS quasi-static lunge positions. The patellofemoral axis of the hinge model was defined by performing surface fits to the patellofemoral contact area; and the moving-axis model was defined based upon the position of the patellofemoral joint at 0° and 90° tibiofemoral-flexion. In between these angles, the patellofemoral axis moved linearly as a function of tibiofemoral-flexion, while outside these angles, the axis remained fixed. When using a moving-axis tibiofemoral joint, a hinge patellofemoral joint offers (-5.12 ± 1.23 mm, 5.81 ± 0.97 mm, 14.98 ± 2.30°, -4.35 ± 1.95°) mean differences (compared to EOS) while a moving-axis patellofemoral model provides (-2.69 ± 1.04 mm, 1.13 ± 0.80 mm, 12.63 ± 2.03°, 1.74 ± 1.46°) in terms of lateral-shift, superior translation, patellofemoral-flexion, and patellar-rotation, respectively. Furthermore, the model predictive capabilities increased as a direct result of adding more calibrated positions to the tibiofemoral model (hinge-1, moving-axis-2, and interpolated-5). Overall, a novel subject-specific moving-axis patellofemoral model has been established; that produces realistic patellar motion and is computationally fast enough for clinical applications.


  • Open Access

    Gait alteration strategies for knee osteoarthritis: a comparison of joint loading via generic and patient-specific musculoskeletal model scaling techniques

    by C M Dzialo, M Mannisi, K S Halonen, M de Zee, J Woodburn, M S Andersen

    Gait modifications and laterally wedged insoles are non-invasive approaches used to treat medial compartment knee osteoarthritis. However, the outcome of these alterations is still a controversial topic. This study investigates how gait alteration techniques may have a unique effect on individual patients; and furthermore, the way we scale our musculoskeletal models to estimate the medial joint contact force may influence knee loading conditions. Five patients with clinical evidence of medial knee osteoarthritis were asked to walk at a normal walking speed over force plates and simultaneously 3D motion was captured during seven conditions (0°-, 5°-, 10°-insoles, shod, toe-in, toe-out, and wide stance). We developed patient-specific musculoskeletal models, using segmentations from magnetic resonance imaging to morph a generic model to patient-specific bone geometries and applied this morphing to estimate muscle insertion sites. Additionally, models were created of these patients using a simple linear scaling method. When examining the patients’ medial compartment contact force (peak and impulse) during stance phase, a ‘one-size-fits-all’ gait alteration aimed to reduce medial knee loading did not exist. Moreover, the different scaling methods lead to differences in medial contact forces; highlighting the importance of further investigation of musculoskeletal modeling methods prior to use in the clinical setting.


  • Open Access

    Workflow assessing the effect of gait alterations on stresses in the medial tibial cartilage - combined musculoskeletal modelling and finite element analysis

    by K. S. Halonen, C. M. Dzialo, M. Mannisi, M. S. Venäläinen, M. de Zee, M. S. Andersen

    Knee osteoarthritis (KOA) is most common in the medial tibial compartment. We present a novel method to study the effect of gait modifications and lateral wedge insoles (LWIs) on the stresses in the medial tibial cartilage by combining musculoskeletal (MS) modelling with finite element (FE) analysis. Subject’s gait was recorded in a gait laboratory, walking normally, with 5° and 10° LWIs, toes inward (‘Toe in’), and toes outward (‘Toe out wide’). A full lower extremity MRI and a detailed knee MRI were taken. Bones and most soft tissues were segmented from images, and the generic bone architecture of the MS model was morphed into the segmented bones. The output forces from the MS model were then used as an input in the FE model of the subject’s knee. During stance, LWIs failed to reduce medial peak pressures apart from Insole 10° during the second peak. Toe in reduced peak pressures by −11% during the first peak but increased them by 12% during the second. Toe out wide reduced peak pressures by −15% during the first and increased them by 7% during the second. The results show that the work flow can assess the effect of interventions on an individual level. In the future, this method can be applied to patients with KOA.


  • A subject-specific analysis framework to investigate gait alterations

    by C.M. Dzialo, M. Mannisi, M. Marra, R. Richards, S. Telfer, J. Woodburn, M. de Zee, M.S. Andersen


  • Open Access

    The Feeding Biomechanics and Dietary Ecology of Paranthropus boisei

    by Amanda L. Smith, Stefano Benazzi, Justin A. Ledogar, Kelli Tamvada, Leslie C. Pryor Smith, Gerhard W. Weber, Mark A. Spencer, Peter W. Lucas, Shaji Michael, Ali Shekeban, et al.

    The African Plio‐Pleistocene hominins known as australopiths evolved derived craniodental features frequently interpreted as adaptations for feeding on either hard, or compliant/tough foods. Among australopiths, Paranthropus boisei is the most robust form, exhibiting traits traditionally hypothesized to produce high bite forces efficiently and strengthen the face against feeding stresses. However, recent mechanical analyses imply that P. boisei may not have been an efficient producer of bite force and that robust morphology in primates is not necessarily strong. Here we use an engineering method, finite element analysis, to show that the facial skeleton of P. boisei is structurally strong, exhibits a strain pattern different from that in chimpanzees (Pan troglodytes) and Australopithecus africanus, and efficiently produces high bite force. It has been suggested that P. boisei consumed a diet of compliant/tough foods like grass blades and sedge pith. However, the blunt occlusal topography of this and other species suggests that australopiths are adapted to consume hard foods, perhaps including grass and sedge seeds. A consideration of evolutionary trends in morphology relating to feeding mechanics suggests that food processing behaviors in gracile australopiths evidently were disrupted by environmental change, perhaps contributing to the eventual evolution of Homo and Paranthropus. Anat Rec, 298:145–167, 2015.


  • Functional implications of squamosal suture size in paranthropus boisei

    by Christine Dzialo, Sarah A. Wood, Michael Berthaume, Amanda Smith, Elizabeth R. Dumont, Stefano Benazzi, Gerhard W. Weber, David S. Strait, Ian R. Grosse

    It has been hypothesized that the extensively overlapping temporal and parietal bones of the squamosal sutures in Paranthropus boisei are adaptations for withstanding loads associated with feeding. Finite element analysis (FEA) was used to investigate the biomechanical effects of suture size (i.e., the area of overlap between the temporal and parietal bones) on stress, strain energy, and strain ratio in the squamosal sutures of Pan troglodytes and P. boisei (specimen OH 5) during biting. Finite element models (FEMs) of OH 5 and a P. troglodytes cranium were constructed from CT scans. These models contain sutures that approximate the actual suture sizes preserved in both crania. The FEM of Pan was then modified to create two additional FEMs with squamosal sutures that are 50% smaller and 25% larger than those in the original model. Comparisons among the models test the effect of suture size on the structural integrity of the squamosal suture as the temporal squama and parietal bone move relative to each other during simulated premolar biting. Results indicate that with increasing suture size there is a decreased risk of suture failure, and that maximum stress values in the OH 5 suture were favorable compared to values in the Pan model with the normal suture size. Strain ratios suggest that shear is an important strain regime in the squamosal suture. This study is consistent with the hypothesis that larger sutures help reduce the likelihood of suture failure under high biting loads. Am J Phys Anthropol 153:260–268, 2014.


  • Viewpoints: Diet and dietary adaptations in early hominins: The hard food perspective

    by David S. Strait, Paul Constantino, Peter W. Lucas, Brian G. Richmond, Mark A. Spencer, Paul C. Dechow, Callum F. Ross, Ian R. Grosse, Barth W. Wright, Bernard A. Wood, et al.

    Recent biomechanical analyses examining the feeding adaptations of early hominins have yielded results consistent with the hypothesis that hard foods exerted a selection pressure that influenced the evolution of australopith morphology. However, this hypothesis appears inconsistent with recent reconstructions of early hominin diet based on dental microwear and stable isotopes. Thus, it is likely that either the diets of some australopiths included a high proportion of foods these taxa were poorly adapted to consume (i.e., foods that they would not have processed efficiently), or that aspects of what we thought we knew about the functional morphology of teeth must be wrong. Evaluation of these possibilities requires a recognition that analyses based on microwear, isotopes, finite element modeling, and enamel chips and cracks each test different types of hypotheses and allow different types of inferences. Microwear and isotopic analyses are best suited to reconstructing broad dietary patterns, but are limited in their ability to falsify specific hypotheses about morphological adaptation. Conversely, finite element analysis is a tool for evaluating the mechanical basis of form‐function relationships, but says little about the frequency with which specific behaviors were performed or the particular types of food that were consumed. Enamel chip and crack analyses are means of both reconstructing diet and examining biomechanics. We suggest that current evidence is consistent with the hypothesis that certain derived australopith traits are adaptations for consuming hard foods, but that australopiths had generalized diets that could include high proportions of foods that were both compliant and tough. Am J Phys Anthropol 151:339–355, 2013.


  • Effect of current density and zinc content during electrical-assisted forming of copper alloys

    by C.M. Dzialo, M.S. Siopis, B.L. Kinsey, K.J. Weinmann