Caroline D. Jordan
Research Subjects
Caroline D. Jordan has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Steven W. Hetts
Radiology, UCSF, San Francisco, California, USA
5 shared publications - Alastair J. Martin
Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
4 shared publications Mark W. Wilson
From the Department of Radiology and Biomedical Imaging (C.Y., D.M., J.Y., A.L., C.L., T.M., C.S., B.K., A.P., M.W.W., S.W.H.) and Department of Bioengineering and Therapeutic Sciences (S.R.), University of California, San Francisco, 505 Parnassus Ave, L-351, San Francisco, CA 94143-0628; and Department of Chemical and Biomolecular Engineering, University of California, Berkeley, Berkeley, Calif (H.J.O.).
4 shared publications- Sravani Kondapavulur
Department of Neurological Surgery, University of California, San Francisco, San Francisco, California, USA
4 shared publications - Ayushi Gautam
Div Interventional Neuroradiology, Johns Hopkins Hospital, Baltimore, Maryland, USA
3 shared publications - Brian A. Hargreaves
Stanford University Stanford University Stanford University Stanford University Stanford University
3 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 15 (1)
Histologic validation of quantitative magnetic resonance relaxation time biomarkers for thrombus chronicity: A feasibility study
- 17 September 2026
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 15 (1)
Open AccessHistologic validation of quantitative magnetic resonance relaxation time biomarkers for thrombus chronicity: A feasibility study
- Open Access
- 6 November 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (11) , 1804-1810
Diffusion Characteristics of Pediatric Diffuse Midline Gliomas with Histone H3-K27M Mutation Using Apparent Diffusion Coefficient Histogram Analysis
BACKGROUND AND PURPOSE: Diffuse midline gliomas with histone H3 K27M mutation are biologically aggressive tumors with poor prognosis defined as a new diagnostic entity in the 2016 World Health Organization Classification of Tumors of the Central Nervous System. There are no qualitative imaging differences (enhancement, border, or central necrosis) between histone H3 wildtype and H3 K27M-mutant diffuse midline gliomas. Herein, we evaluated the utility of diffusion-weighted imaging to distinguish H3 K27M-mutant from histone H3 wildtype diffuse midline gliomas. MATERIALS AND METHODS: We identified 31 pediatric patients (younger than 21 years of age) with diffuse gliomas centered in midline structures that had undergone assessment for histone H3 K27M mutation. We measured ADC within these tumors using a voxel-based 3D whole-tumor measurement method. RESULTS: Our cohort included 18 infratentorial and 13 supratentorial diffuse gliomas centered in midline structures. Twenty-three (74%) tumors carried H3-K27M mutations. There was no difference in ADC histogram parameters (mean, median, minimum, maximum, percentiles) between mutant and wild-type tumors. Subgroup analysis based on tumor location also did not identify a difference in histogram descriptive statistics. Patients who survived 1 year (1.46 × 10−3mm2/s; 95% CI, 1.19–1.67; P < .06). Average ADC values for diffuse midline gliomas were 1.28 × 10−3mm2/s (95% CI, 1.21–1.34) and 0.86 × 10−3mm2/s (95% CI, 0.69–1.01) for hemispheric glioblastomas with P < .05. CONCLUSIONS: Although no statistically significant difference in diffusion characteristics was found between H3-K27M mutant and H3 wildtype diffuse midline gliomas, lower diffusivity corresponds to a lower survival rate at 1 year after diagnosis. These findings can have an impact on the anticipated clinical course for this patient population and offer providers and families guidance on clinical outcomes.
- 6 November 2019
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 40 (11) , 1804-1810
Open AccessDiffusion Characteristics of Pediatric Diffuse Midline Gliomas with Histone H3-K27M Mutation Using Apparent Diffusion Coefficient Histogram Analysis
BACKGROUND AND PURPOSE: Diffuse midline gliomas with histone H3 K27M mutation are biologically aggressive tumors with poor prognosis defined as a new diagnostic entity in the 2016 World Health Organization Classification of Tumors of the Central Nervous System. There are no qualitative imaging differences (enhancement, border, or central necrosis) between histone H3 wildtype and H3 K27M-mutant diffuse midline gliomas. Herein, we evaluated the utility of diffusion-weighted imaging to distinguish H3 K27M-mutant from histone H3 wildtype diffuse midline gliomas. MATERIALS AND METHODS: We identified 31 pediatric patients (younger than 21 years of age) with diffuse gliomas centered in midline structures that had undergone assessment for histone H3 K27M mutation. We measured ADC within these tumors using a voxel-based 3D whole-tumor measurement method. RESULTS: Our cohort included 18 infratentorial and 13 supratentorial diffuse gliomas centered in midline structures. Twenty-three (74%) tumors carried H3-K27M mutations. There was no difference in ADC histogram parameters (mean, median, minimum, maximum, percentiles) between mutant and wild-type tumors. Subgroup analysis based on tumor location also did not identify a difference in histogram descriptive statistics. Patients who survived 1 year (1.46 × 10−3mm2/s; 95% CI, 1.19–1.67; P < .06). Average ADC values for diffuse midline gliomas were 1.28 × 10−3mm2/s (95% CI, 1.21–1.34) and 0.86 × 10−3mm2/s (95% CI, 0.69–1.01) for hemispheric glioblastomas with P < .05. CONCLUSIONS: Although no statistically significant difference in diffusion characteristics was found between H3-K27M mutant and H3 wildtype diffuse midline gliomas, lower diffusivity corresponds to a lower survival rate at 1 year after diagnosis. These findings can have an impact on the anticipated clinical course for this patient population and offer providers and families guidance on clinical outcomes.
- 1 September 2019
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 1 (1) , e190009
Endovascular Ion Exchange Chemofiltration Device Reduces Off-Target Doxorubicin Exposure in a Hepatic Intra-arterial Chemotherapy Model
Image-guided endovascular chemofiltration with ionic endovascular devices placed nonocclusively in the hepatic venous outflow tract and inferior vena cava during hepatic artery doxorubicin infusion... Purpose To determine if endovascular chemofiltration with an ionic device (ChemoFilter [CF]) can be used to reduce systemic exposure and off-target biodistribution of doxorubicin (DOX) during hepat...
- 1 September 2019
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 1 (1) , e190009
Endovascular Ion Exchange Chemofiltration Device Reduces Off-Target Doxorubicin Exposure in a Hepatic Intra-arterial Chemotherapy Model
Image-guided endovascular chemofiltration with ionic endovascular devices placed nonocclusively in the hepatic venous outflow tract and inferior vena cava during hepatic artery doxorubicin infusion... Purpose To determine if endovascular chemofiltration with an ionic device (ChemoFilter [CF]) can be used to reduce systemic exposure and off-target biodistribution of doxorubicin (DOX) during hepat...
- 21 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (3) , 876-882
Wireless Resonant Circuits Printed Using Aerosol Jet Deposition for MRI Catheter Tracking
Interventional magnetic resonance imaging (MRI) could allow for diagnosis and immediate treatment of ischemic stroke; however, such endovascular catheter-based procedures under MRI guidance are inherently difficult. One major challenge is tracking the tip of the catheter, as standard fabrication methods for building inductively coupled coil markers are rigid and bulky. Here, we report a new approach that uses aerosol jet deposition to three-dimensional (3-D) print an inductively coupled RF coil marker on a polymer catheter. Our approach enables lightweight conforming markers on polymer catheters and these low-profile markers allow the catheter to be more safely navigated in small caliber vessels. Prototype markers with an inductor with the geometry of a double helix are incorporated on catheters for in vitro studies, and we show that these markers exhibit good signal amplification. We report temperature measurements and, finally, demonstrate feasibility in a preliminary in vivo experiment. We provide material properties and electromagnetic simulation performance analysis. This paper presents fully aerosol jet-deposited and functional wireless resonant markers on polymer catheters for use in 3T clinical scanners.
- 21 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (3) , 876-882
Wireless Resonant Circuits Printed Using Aerosol Jet Deposition for MRI Catheter Tracking
Interventional magnetic resonance imaging (MRI) could allow for diagnosis and immediate treatment of ischemic stroke; however, such endovascular catheter-based procedures under MRI guidance are inherently difficult. One major challenge is tracking the tip of the catheter, as standard fabrication methods for building inductively coupled coil markers are rigid and bulky. Here, we report a new approach that uses aerosol jet deposition to three-dimensional (3-D) print an inductively coupled RF coil marker on a polymer catheter. Our approach enables lightweight conforming markers on polymer catheters and these low-profile markers allow the catheter to be more safely navigated in small caliber vessels. Prototype markers with an inductor with the geometry of a double helix are incorporated on catheters for in vitro studies, and we show that these markers exhibit good signal amplification. We report temperature measurements and, finally, demonstrate feasibility in a preliminary in vivo experiment. We provide material properties and electromagnetic simulation performance analysis. This paper presents fully aerosol jet-deposited and functional wireless resonant markers on polymer catheters for use in 3T clinical scanners.
- 14 May 2018
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 48 (6) , 1717-1720
Quantification of 89Zr‐Iron oxide nanoparticle biodistribution using PET‐MR and ultrashort TE sequences
- 14 May 2018
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 48 (6) , 1717-1720
Quantification of 89Zr‐Iron oxide nanoparticle biodistribution using PET‐MR and ultrashort TE sequences
- 25 September 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (4) , 1-11
Interventional magnetic resonance imaging guided carotid embolectomy using a novel resonant marker catheter: demonstration of preclinical feasibility
To assess the visualization and efficacy of a wireless resonant circuit (wRC) catheter system for carotid artery occlusion and embolectomy under real-time MRI guidance in vivo, and to compare MR imaging modality with x-ray for analysis of qualitative physiological measures of blood flow at baseline and after embolectomy. The wRC catheter system was constructed using a MR compatible PEEK fiber braided catheter (Penumbra, Inc, Alameda, CA) with a single insulated longitudinal copper loop soldered to a printed circuit board embedded within the catheter wall. In concordance with IACUC protocol (AN103047), in vivo carotid artery navigation and embolectomy were performed in four farm pigs (40–45 kg) under real-time MRI at 1.5T. Industry standard clots were introduced in incremental amounts until adequate arterial occlusion was noted in a total of n=13 arteries. Baseline vasculature and restoration of blood flow were confirmed via MR and x-ray imaging, and graded by the Thrombolysis in Cerebral Infarction (TICI) scale. Wilcoxon signed-rank tests were used to analyze differences in recanalization status between DSA and MRA imaging. Successful recanalizations (TICI 2b/3) were compared to clinical rates reported in literature via binomial tests. The wRC catheter system was visible both on 5° sagittal bSSFP and coronal GRE sequence. Successful recanalization was demonstrated in 11 of 13 occluded arteries by DSA analysis and 8 of 13 by MRA. Recanalization rates based on DSA (0.85) and MRA (0.62) were not significantly different from the clinical rate of mechanical aspiration thrombectomy reported in literature. Lastly, a Wilcoxon signed rank test indicated no significant difference between TICI scores analyzed by DSA and MRA. With demonstrated compatibility and visualization under MRI, the wRC catheter system is effective for in vivo endovascular embolectomy, suggesting progress towards clinical endovascular interventional MRI.
- 25 September 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (4) , 1-11
Interventional magnetic resonance imaging guided carotid embolectomy using a novel resonant marker catheter: demonstration of preclinical feasibility
To assess the visualization and efficacy of a wireless resonant circuit (wRC) catheter system for carotid artery occlusion and embolectomy under real-time MRI guidance in vivo, and to compare MR imaging modality with x-ray for analysis of qualitative physiological measures of blood flow at baseline and after embolectomy. The wRC catheter system was constructed using a MR compatible PEEK fiber braided catheter (Penumbra, Inc, Alameda, CA) with a single insulated longitudinal copper loop soldered to a printed circuit board embedded within the catheter wall. In concordance with IACUC protocol (AN103047), in vivo carotid artery navigation and embolectomy were performed in four farm pigs (40–45 kg) under real-time MRI at 1.5T. Industry standard clots were introduced in incremental amounts until adequate arterial occlusion was noted in a total of n=13 arteries. Baseline vasculature and restoration of blood flow were confirmed via MR and x-ray imaging, and graded by the Thrombolysis in Cerebral Infarction (TICI) scale. Wilcoxon signed-rank tests were used to analyze differences in recanalization status between DSA and MRA imaging. Successful recanalizations (TICI 2b/3) were compared to clinical rates reported in literature via binomial tests. The wRC catheter system was visible both on 5° sagittal bSSFP and coronal GRE sequence. Successful recanalization was demonstrated in 11 of 13 occluded arteries by DSA analysis and 8 of 13 by MRA. Recanalization rates based on DSA (0.85) and MRA (0.62) were not significantly different from the clinical rate of mechanical aspiration thrombectomy reported in literature. Lastly, a Wilcoxon signed rank test indicated no significant difference between TICI scores analyzed by DSA and MRA. With demonstrated compatibility and visualization under MRI, the wRC catheter system is effective for in vivo endovascular embolectomy, suggesting progress towards clinical endovascular interventional MRI.
- 1 April 2017
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 7 (2) , 187-194
Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging
Background: It is technically challenging to design compact yet sensitive miniature catheter radio frequency (RF) coils for endovascular interventional MR imaging. Methods: In this work, a new design method for catheter RF coils is proposed based on the coaxial transmission line resonator (TLR) technique. Due to its distributed circuit, the TLR catheter coil does not need any lumped capacitors to support its resonance, which simplifies the practical design and construction and provides a straightforward technique for designing miniature catheter-mounted imaging coils that are appropriate for interventional neurovascular procedures. The outer conductor of the TLR serves as an RF shield, which prevents electromagnetic energy loss, and improves coil Q factors. It also minimizes interaction with surrounding tissues and signal losses along the catheter coil. To investigate the technique, a prototype catheter coil was built using the proposed coaxial TLR technique and evaluated with standard RF testing and measurement methods and MR imaging experiments. Numerical simulation was carried out to assess the RF electromagnetic field behavior of the proposed TLR catheter coil and the conventional lumped-element catheter coil. Results: The proposed TLR catheter coil was successfully tuned to 64 MHz for proton imaging at 1.5 T. B1 fields were numerically calculated, showing improved magnetic field intensity of the TLR catheter coil over the conventional lumped-element catheter coil. MR images were acquired from a dedicated vascular phantom using the TLR catheter coil and also the system body coil. The TLR catheter coil is able to provide a significant signal-to-noise ratio (SNR) increase (a factor of 200 to 300) over its imaging volume relative to the body coil. Conclusions: Catheter imaging RF coil design using the proposed coaxial TLR technique is feasible and advantageous in endovascular interventional MR imaging applications.
- 1 April 2017
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 7 (2) , 187-194
Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging
Background: It is technically challenging to design compact yet sensitive miniature catheter radio frequency (RF) coils for endovascular interventional MR imaging. Methods: In this work, a new design method for catheter RF coils is proposed based on the coaxial transmission line resonator (TLR) technique. Due to its distributed circuit, the TLR catheter coil does not need any lumped capacitors to support its resonance, which simplifies the practical design and construction and provides a straightforward technique for designing miniature catheter-mounted imaging coils that are appropriate for interventional neurovascular procedures. The outer conductor of the TLR serves as an RF shield, which prevents electromagnetic energy loss, and improves coil Q factors. It also minimizes interaction with surrounding tissues and signal losses along the catheter coil. To investigate the technique, a prototype catheter coil was built using the proposed coaxial TLR technique and evaluated with standard RF testing and measurement methods and MR imaging experiments. Numerical simulation was carried out to assess the RF electromagnetic field behavior of the proposed TLR catheter coil and the conventional lumped-element catheter coil. Results: The proposed TLR catheter coil was successfully tuned to 64 MHz for proton imaging at 1.5 T. B1 fields were numerically calculated, showing improved magnetic field intensity of the TLR catheter coil over the conventional lumped-element catheter coil. MR images were acquired from a dedicated vascular phantom using the TLR catheter coil and also the system body coil. The TLR catheter coil is able to provide a significant signal-to-noise ratio (SNR) increase (a factor of 200 to 300) over its imaging volume relative to the body coil. Conclusions: Catheter imaging RF coil design using the proposed coaxial TLR technique is feasible and advantageous in endovascular interventional MR imaging applications.
- 1 April 2017
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 25 (4) , 513-520
Cluster analysis of quantitative MRI T2 and T1 relaxation times of cartilage identifies differences between healthy and ACL-injured individuals at 3T
- 1 April 2017
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 25 (4) , 513-520
Cluster analysis of quantitative MRI T2 and T1 relaxation times of cartilage identifies differences between healthy and ACL-injured individuals at 3T
- 10 November 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (6) , 1-13
Optimization of an endovascular magnetic filter for maximized capture of magnetic nanoparticles
To computationally optimize the design of an endovascular magnetic filtration device that binds iron oxide nanoparticles and to validate simulations with experimental results of prototype devices in physiologic flow testing. Three-dimensional computational models of different endovascular magnetic filter devices assessed magnetic particle capture. We simulated a series of cylindrical neodymium N52 magnets and capture of 1500 iron oxide nanoparticles infused in a simulated 14 mm-diameter vessel. Device parameters varied included: magnetization orientation (across the diameter, “D”, along the length, “L”, of the filter), magnet outer diameter (3, 4, 5 mm), magnet length (5, 10 mm), and spacing between magnets (1, 3 mm). Top designs were tested in vitro using 89Zr-radiolabeled iron oxide nanoparticles and gamma counting both in continuous and multiple pass flow model. Computationally, “D” magnetized devices had greater capture than “L” magnetized devices. Increasing outer diameter of magnets increased particle capture as follows: “D” designs, 3 mm: 12.8–13.6 %, 4 mm: 16.6–17.6 %, 5 mm: 21.8–24.6 %; “L” designs, 3 mm: 5.6–10 %, 4 mm: 9.4–15.8 %, 5 mm: 14.8–21.2 %. In vitro, while there was significant capture by all device designs, with most capturing 87–93 % within the first two minutes, compared to control non-magnetic devices, there was no significant difference in particle capture with the parameters varied. The computational study predicts that endovascular magnetic filters demonstrate maximum particle capture with “D” magnetization. In vitro flow testing demonstrated no difference in capture with varied parameters. Clinically, “D” magnetized devices would be most practical, sized as large as possible without causing intravascular flow obstruction.
- 10 November 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (6) , 1-13
Optimization of an endovascular magnetic filter for maximized capture of magnetic nanoparticles
To computationally optimize the design of an endovascular magnetic filtration device that binds iron oxide nanoparticles and to validate simulations with experimental results of prototype devices in physiologic flow testing. Three-dimensional computational models of different endovascular magnetic filter devices assessed magnetic particle capture. We simulated a series of cylindrical neodymium N52 magnets and capture of 1500 iron oxide nanoparticles infused in a simulated 14 mm-diameter vessel. Device parameters varied included: magnetization orientation (across the diameter, “D”, along the length, “L”, of the filter), magnet outer diameter (3, 4, 5 mm), magnet length (5, 10 mm), and spacing between magnets (1, 3 mm). Top designs were tested in vitro using 89Zr-radiolabeled iron oxide nanoparticles and gamma counting both in continuous and multiple pass flow model. Computationally, “D” magnetized devices had greater capture than “L” magnetized devices. Increasing outer diameter of magnets increased particle capture as follows: “D” designs, 3 mm: 12.8–13.6 %, 4 mm: 16.6–17.6 %, 5 mm: 21.8–24.6 %; “L” designs, 3 mm: 5.6–10 %, 4 mm: 9.4–15.8 %, 5 mm: 14.8–21.2 %. In vitro, while there was significant capture by all device designs, with most capturing 87–93 % within the first two minutes, compared to control non-magnetic devices, there was no significant difference in particle capture with the parameters varied. The computational study predicts that endovascular magnetic filters demonstrate maximum particle capture with “D” magnetization. In vitro flow testing demonstrated no difference in capture with varied parameters. Clinically, “D” magnetized devices would be most practical, sized as large as possible without causing intravascular flow obstruction.
- 24 October 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (6) , 1-9
In vitro clearance of doxorubicin with a DNA-based filtration device designed for intravascular use with intra-arterial chemotherapy
To report a novel method using immobilized DNA within mesh to sequester drugs that have intrinsic DNA binding characteristics directly from flowing blood. DNA binding experiments were carried out in vitro with doxorubicin in saline (PBS solution), porcine serum, and porcine blood. Genomic DNA was used to identify the concentration of DNA that shows optimum binding clearance of doxorubicin from solution. Doxorubicin binding kinetics by DNA enclosed within porous mesh bags was evaluated. Flow model simulating blood flow in the inferior vena cava was used to determine in vitro binding kinetics between doxorubicin and DNA. The kinetics of doxorubicin binding to free DNA is dose-dependent and rapid, with 82–96 % decrease in drug concentration from physiologic solutions within 1 min of reaction time. DNA demonstrates faster binding kinetics by doxorubicin as compared to polystyrene resins that use an ion exchange mechanism. DNA contained within mesh yields an approximately 70 % decrease in doxorubicin concentration from solution within 5 min. In the IVC flow model, there is a 70 % drop in doxorubicin concentration at 60 min. A DNA-containing ChemoFilter device can rapidly clear clinical doses of doxorubicin from a flow model in simple and complex physiological solutions, thereby suggesting a novel approach to reduce the toxicity of DNA-binding drugs.
- 24 October 2016
- Published by Springer Nature in Biomedical Microdevices
- Vol. 18 (6) , 1-9
In vitro clearance of doxorubicin with a DNA-based filtration device designed for intravascular use with intra-arterial chemotherapy
To report a novel method using immobilized DNA within mesh to sequester drugs that have intrinsic DNA binding characteristics directly from flowing blood. DNA binding experiments were carried out in vitro with doxorubicin in saline (PBS solution), porcine serum, and porcine blood. Genomic DNA was used to identify the concentration of DNA that shows optimum binding clearance of doxorubicin from solution. Doxorubicin binding kinetics by DNA enclosed within porous mesh bags was evaluated. Flow model simulating blood flow in the inferior vena cava was used to determine in vitro binding kinetics between doxorubicin and DNA. The kinetics of doxorubicin binding to free DNA is dose-dependent and rapid, with 82–96 % decrease in drug concentration from physiologic solutions within 1 min of reaction time. DNA demonstrates faster binding kinetics by doxorubicin as compared to polystyrene resins that use an ion exchange mechanism. DNA contained within mesh yields an approximately 70 % decrease in doxorubicin concentration from solution within 5 min. In the IVC flow model, there is a 70 % drop in doxorubicin concentration at 60 min. A DNA-containing ChemoFilter device can rapidly clear clinical doses of doxorubicin from a flow model in simple and complex physiological solutions, thereby suggesting a novel approach to reduce the toxicity of DNA-binding drugs.