Thibaut Kovaltchouk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thibaut Kovaltchouk has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Bernard Multon
6 shared publicationsHamid Ben Ahmed
6 shared publicationsJudicael Aubry
Energy and Embedded systems for transportation, ESTACA'Lab, Laval, France
5 shared publications- Pascal Venet
CNRS, Ampère, UMR5005
3 shared publications - Mazen Alamir
Univ. Grenoble Alpes CNRS Grenoble INP GIPSA-lab 38000 Grenoble France
2 shared publications Sara Armstrong
2 shared publications
Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contributions à la co-optimisation contrôle-dimensionnement sur cycle de vie sous contrainte réseau des houlogénérateurs directs
Les Energies Marines Renouvelables (EMR) se développent aujourd’hui très vite tant au niveau de la recherche amont que de la R&D, et même des premiers démonstrateurs à la mer. Parmi ces EMR, l'énergie des vagues présente un potentiel particulièrement intéressant. Avec une ressource annuelle brute moyenne estimée à 40 kW/m au large de la côte atlantique, le littoral français est plutôt bien exposé. Mais l’exploitation à grande échelle de cette énergie renouvelable ne sera réalisable et pertinente qu'à condition d'une bonne intégration au réseau électrique (qualité) ainsi que d'une gestion et d'un dimensionnement optimisé au sens du coût sur cycle de vie. Une première solution de génération tout électrique pour un houlogénérateur a d’abord été évaluée dans le cadre de la thèse de Marie RUELLAN menée sur le site de Bretagne du laboratoire SATIE (ENS de Cachan). Ces travaux ont mis en évidence le potentiel de viabilité économique de cette chaîne de conversion et ont permis de poser la question du dimensionnement de l’ensemble convertisseur-machine et de soulever les problèmes associés à la qualité de l’énergie produite. Puis une seconde thèse a été menée par Judicaël AUBRY dans la même équipe de recherche. Elle a consisté, entre autres, en l’étude d’une première solution de traitement des fluctuations de la puissance basée sur un système de stockage par supercondensateurs. Une méthodologie de dimensionnement de l’ensemble convertisseur-machine et de gestion de l’énergie stockée fut également élaborée, mais en découplant le dimensionnement et la gestion de la production d’énergie et de ceux de son système de stockage. Le doctorant devra donc : 1. S’approprier les travaux antérieurs réalisés dans le domaine de la récupération de l’énergie des vagues ainsi que les modèles hydrodynamiques et mécaniques réalisés par notre partenaire : le LHEEA de l’Ecole Centrale de Nantes - 2. Résoudre le problème du couplage entre dimensionnement/gestion de la chaîne de conversion et dimensionnement/gestion du système de stockage. 3. Participer à la réalisation d’un banc test à échelle réduite de la chaine électrique et valider expérimentalement les modèles énergétiques du stockage et des convertisseurs statiques associés - 4. Proposer une méthodologie de dimensionnement de la chaine électrique intégrant le stockage et les lois de contrôle préalablement élaborées 5. Déterminer les gains en termes de capacités de stockage obtenus grâce à la mutualisation de la production (parc de machines) et évaluer l’intérêt d’un stockage centralisé - 6. Analyser l’impact sur le réseau d’une production houlogénérée selon divers scenarii, modèles et outils développés par tous les partenaires dans le cadre du projet QUALIPHE. L’exemple traité sera celui de l’Ile d’Yeu (en collaboration avec le SyDEV.
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contributions à la co-optimisation contrôle-dimensionnement sur cycle de vie sous contrainte réseau des houlogénérateurs directs
Les Energies Marines Renouvelables (EMR) se développent aujourd’hui très vite tant au niveau de la recherche amont que de la R&D, et même des premiers démonstrateurs à la mer. Parmi ces EMR, l'énergie des vagues présente un potentiel particulièrement intéressant. Avec une ressource annuelle brute moyenne estimée à 40 kW/m au large de la côte atlantique, le littoral français est plutôt bien exposé. Mais l’exploitation à grande échelle de cette énergie renouvelable ne sera réalisable et pertinente qu'à condition d'une bonne intégration au réseau électrique (qualité) ainsi que d'une gestion et d'un dimensionnement optimisé au sens du coût sur cycle de vie. Une première solution de génération tout électrique pour un houlogénérateur a d’abord été évaluée dans le cadre de la thèse de Marie RUELLAN menée sur le site de Bretagne du laboratoire SATIE (ENS de Cachan). Ces travaux ont mis en évidence le potentiel de viabilité économique de cette chaîne de conversion et ont permis de poser la question du dimensionnement de l’ensemble convertisseur-machine et de soulever les problèmes associés à la qualité de l’énergie produite. Puis une seconde thèse a été menée par Judicaël AUBRY dans la même équipe de recherche. Elle a consisté, entre autres, en l’étude d’une première solution de traitement des fluctuations de la puissance basée sur un système de stockage par supercondensateurs. Une méthodologie de dimensionnement de l’ensemble convertisseur-machine et de gestion de l’énergie stockée fut également élaborée, mais en découplant le dimensionnement et la gestion de la production d’énergie et de ceux de son système de stockage. Le doctorant devra donc : 1. S’approprier les travaux antérieurs réalisés dans le domaine de la récupération de l’énergie des vagues ainsi que les modèles hydrodynamiques et mécaniques réalisés par notre partenaire : le LHEEA de l’Ecole Centrale de Nantes - 2. Résoudre le problème du couplage entre dimensionnement/gestion de la chaîne de conversion et dimensionnement/gestion du système de stockage. 3. Participer à la réalisation d’un banc test à échelle réduite de la chaine électrique et valider expérimentalement les modèles énergétiques du stockage et des convertisseurs statiques associés - 4. Proposer une méthodologie de dimensionnement de la chaine électrique intégrant le stockage et les lois de contrôle préalablement élaborées 5. Déterminer les gains en termes de capacités de stockage obtenus grâce à la mutualisation de la production (parc de machines) et évaluer l’intérêt d’un stockage centralisé - 6. Analyser l’impact sur le réseau d’une production houlogénérée selon divers scenarii, modèles et outils développés par tous les partenaires dans le cadre du projet QUALIPHE. L’exemple traité sera celui de l’Ile d’Yeu (en collaboration avec le SyDEV.
- Open Access
- 1 June 2016
- Published by Elsevier in Renewable Energy
- Vol. 91, 32-39
Wave farm flicker severity: Comparative analysis and solutions
- 1 June 2016
- Published by Elsevier in Renewable Energy
- Vol. 91, 32-39
Open AccessWave farm flicker severity: Comparative analysis and solutions
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Assessment of the impact of frequency containment control and synthetic inertia on intermittent energies generators integration
The increasing power generation out of intermittent renewable energy sources will result in a reduction of the grid stability if no compensatory actions are taken. This issue may lead to future obligations for energy providers. This paper studies the implication of the future obligations for generators in Europe according to the recommendations of ENTSO-E, in particular the obligation for some generators to have a synthetic (or virtual) inertia and a frequency sensitive control. These obligations will be described in details in the paper, in particular their effect on the grid management and stability. The impact of this new actions on the energy production will be discussed. The continental European grid frequency is used as an example.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Assessment of the impact of frequency containment control and synthetic inertia on intermittent energies generators integration
The increasing power generation out of intermittent renewable energy sources will result in a reduction of the grid stability if no compensatory actions are taken. This issue may lead to future obligations for energy providers. This paper studies the implication of the future obligations for generators in Europe according to the recommendations of ENTSO-E, in particular the obligation for some generators to have a synthetic (or virtual) inertia and a frequency sensitive control. These obligations will be described in details in the paper, in particular their effect on the grid management and stability. The impact of this new actions on the energy production will be discussed. The continental European grid frequency is used as an example.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-7
Active power control under Grid Code constraints for a tidal farm
This paper proposes an active power control framework for a tidal turbine farm. The control framework is based on the solution of a linear programming problem that is built to satisfy the power demand while taking into account the maximum achievable power as well as the Grid Code constraints in the (active/reactive) power plan. An illustrative example involving a 50-turbines farm is proposed in order to show the relevance and efficiency of the proposed approach.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-7
Active power control under Grid Code constraints for a tidal farm
This paper proposes an active power control framework for a tidal turbine farm. The control framework is based on the solution of a linear programming problem that is built to satisfy the power demand while taking into account the maximum achievable power as well as the Grid Code constraints in the (active/reactive) power plan. An illustrative example involving a 50-turbines farm is proposed in order to show the relevance and efficiency of the proposed approach.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An aging-aware life cycle cost comparison between supercapacitors and Li-ion batteries to smooth Direct Wave Energy Converter production
This article compares the performance of two energy storage technologies, namely supercapacitors and Li-ion batteries, in the context of Direct Wave Energy Converters (DWEC). Both the sizing and management of an Energy Storage System (ESS) are described, and the SEAREV project has been used as an example. The main objective is to compare the two technologies on the basis of their life cycle cost. The ESS is necessary for grid integration due to the flicker constraint, which is not being satisfied without storage. The rule-based energy management approach introduced herein depends on the State of Energy of this ESS as well as the power produced by the DWEC. This management strategy has been optimized for each size in order to reduce aging speed while strictly respecting the flicker criterion. The final design is expected to minimize total system cost, i.e. the sum of investment cost and operating cost (losses and replacements). The aging models applied take into account temperature and cycling effect in order to estimate this replacement cost. Such an optimization routine is especially critical for offshore systems like Direct Wave Energy Converters, which require both cost reduction and high reliability.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An aging-aware life cycle cost comparison between supercapacitors and Li-ion batteries to smooth Direct Wave Energy Converter production
This article compares the performance of two energy storage technologies, namely supercapacitors and Li-ion batteries, in the context of Direct Wave Energy Converters (DWEC). Both the sizing and management of an Energy Storage System (ESS) are described, and the SEAREV project has been used as an example. The main objective is to compare the two technologies on the basis of their life cycle cost. The ESS is necessary for grid integration due to the flicker constraint, which is not being satisfied without storage. The rule-based energy management approach introduced herein depends on the State of Energy of this ESS as well as the power produced by the DWEC. This management strategy has been optimized for each size in order to reduce aging speed while strictly respecting the flicker criterion. The final design is expected to minimize total system cost, i.e. the sum of investment cost and operating cost (losses and replacements). The aging models applied take into account temperature and cycling effect in order to estimate this replacement cost. Such an optimization routine is especially critical for offshore systems like Direct Wave Energy Converters, which require both cost reduction and high reliability.
- 4 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 3 (4) , 1011-1020
Assessing the Impact of the Grid-Connected Pacific Marine Energy Center Wave Farm
A new wave energy test site, Pacific Marine Energy Center-South Energy Test Site (PMEC-SETS) - is being proposed for construction off the coast of Newport, Oregon, U.S. The intermittent nature of wave energy presents a unique challenge for the transmission system operator, as the integration of a wave energy farm onto the electrical grid creates the potential for disturbance to the operation and stability of the grid. Consequently, this paper assesses the PMEC-SETS development and the impact of its connection to the Oregon (and the rest of the Western Interconnection) network, in terms of steady-state, dynamic, and transient characteristics. The electrical infrastructure analysis is implemented using two power system simulation tools: 1) PowerWorld and 2) DIgSILENT PowerFactory. Power-World is used to create an equivalent model of the transmission system, and DIgSILENT PowerFactory is used to examine the impact of the wave farm at the point of connection, under normal and faulted conditions. A case study of 20 wave energy converters is used to illustrate the results.
- 4 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 3 (4) , 1011-1020
Assessing the Impact of the Grid-Connected Pacific Marine Energy Center Wave Farm
A new wave energy test site, Pacific Marine Energy Center-South Energy Test Site (PMEC-SETS) - is being proposed for construction off the coast of Newport, Oregon, U.S. The intermittent nature of wave energy presents a unique challenge for the transmission system operator, as the integration of a wave energy farm onto the electrical grid creates the potential for disturbance to the operation and stability of the grid. Consequently, this paper assesses the PMEC-SETS development and the impact of its connection to the Oregon (and the rest of the Western Interconnection) network, in terms of steady-state, dynamic, and transient characteristics. The electrical infrastructure analysis is implemented using two power system simulation tools: 1) PowerWorld and 2) DIgSILENT PowerFactory. Power-World is used to create an equivalent model of the transmission system, and DIgSILENT PowerFactory is used to examine the impact of the wave farm at the point of connection, under normal and faulted conditions. A case study of 20 wave energy converters is used to illustrate the results.
- Open Access
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Comparison between centralized and decentralized storage energy management for Direct Wave Energy Converter Farm
This article compares the sizes of an Energy Storage System (ESS) with two control types in order to smooth a Direct Wave Energy Converter (DWEC) Farm Production, namely a centralized one that deals with the PCC power and a decentralized one that deals with each unit power production. The main objective is to compare the two controls on the basis of their life cycle cost. The SEAREV project is the Direct Wave Energy Converter used as an example in this paper. The ESS is necessary for grid integration in the case considered here due to the flicker constraint, which is not being satisfied without storage. The optimization strategies for both the sizing and the management of an Energy Storage System (ESS) will be described: the rule-based energy management approach depends on the State of Energy of this ESS as well as the power produced by the DWEC unit or the DWEC farm. This management strategy has been optimized for each size in order to reduce aging speed while strictly respecting the flicker criterion. The final design is expected to minimize total system cost. The centralized control clearly allowed smaller capacity, but has some drawbacks for the losses in the rest of the farm.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Open AccessComparison between centralized and decentralized storage energy management for Direct Wave Energy Converter Farm
This article compares the sizes of an Energy Storage System (ESS) with two control types in order to smooth a Direct Wave Energy Converter (DWEC) Farm Production, namely a centralized one that deals with the PCC power and a decentralized one that deals with each unit power production. The main objective is to compare the two controls on the basis of their life cycle cost. The SEAREV project is the Direct Wave Energy Converter used as an example in this paper. The ESS is necessary for grid integration in the case considered here due to the flicker constraint, which is not being satisfied without storage. The optimization strategies for both the sizing and the management of an Energy Storage System (ESS) will be described: the rule-based energy management approach depends on the State of Energy of this ESS as well as the power produced by the DWEC unit or the DWEC farm. This management strategy has been optimized for each size in order to reduce aging speed while strictly respecting the flicker criterion. The final design is expected to minimize total system cost. The centralized control clearly allowed smaller capacity, but has some drawbacks for the losses in the rest of the farm.
- 12 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 51 (3) , 2405-2414
Enhanced Aging Model for Supercapacitors Taking Into Account Power Cycling: Application to the Sizing of an Energy Storage System in a Direct Wave Energy Converter
This paper proposes an original model for supercapacitors that takes into account both calendar aging and cycling aging. A state variable is used to quantify the state of aging. This model is based on a series of recent experiments conducted in various research laboratories on the same technology (Maxwell Technology) and serves to represent the degradation of equivalent series resistance and capacitance. This model is particularly useful in an aging-aware life-cycle cost analysis. We show that an accurate aging model is critical to the design of an energy storage system that optimizes the economic life-cycle cost. Such an optimization is particularly applicable for smoothing in offshore systems such as direct wave energy converters, which require both cost reduction and high reliability. The influence of an aging model in the sizing process is investigated toward the end of this paper.
- 12 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 51 (3) , 2405-2414
Enhanced Aging Model for Supercapacitors Taking Into Account Power Cycling: Application to the Sizing of an Energy Storage System in a Direct Wave Energy Converter
This paper proposes an original model for supercapacitors that takes into account both calendar aging and cycling aging. A state variable is used to quantify the state of aging. This model is based on a series of recent experiments conducted in various research laboratories on the same technology (Maxwell Technology) and serves to represent the degradation of equivalent series resistance and capacitance. This model is particularly useful in an aging-aware life-cycle cost analysis. We show that an accurate aging model is critical to the design of an energy storage system that optimizes the economic life-cycle cost. Such an optimization is particularly applicable for smoothing in offshore systems such as direct wave energy converters, which require both cost reduction and high reliability. The influence of an aging model in the sizing process is investigated toward the end of this paper.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Enhanced aging model for supercapacitors taking into account power cycling: Application to the sizing of an Energy Storage System in a Direct Wave Energy Converter
This paper proposes an original model for supercapacitors that takes into account both calendar aging and cycling aging. This model is based on a series of recent experiments conducted in various research laboratories on the same technology (Maxwell Technology) and serves to represent the degradation of Equivalent Series Resistance and capacitance. We show that an accurate aging model is critical to the design of an Energy Storage System that optimizes the economic life cycle cost. Such an optimization is especially applicable for smoothing in offshore systems like Direct Wave Energy Converters, which require both cost reduction and high reliability. The influence of an aging model in the sizing process is investigated towards the end of this paper.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
Enhanced aging model for supercapacitors taking into account power cycling: Application to the sizing of an Energy Storage System in a Direct Wave Energy Converter
This paper proposes an original model for supercapacitors that takes into account both calendar aging and cycling aging. This model is based on a series of recent experiments conducted in various research laboratories on the same technology (Maxwell Technology) and serves to represent the degradation of Equivalent Series Resistance and capacitance. We show that an accurate aging model is critical to the design of an Energy Storage System that optimizes the economic life cycle cost. Such an optimization is especially applicable for smoothing in offshore systems like Direct Wave Energy Converters, which require both cost reduction and high reliability. The influence of an aging model in the sizing process is investigated towards the end of this paper.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 37, 1-9
Preliminary sizing of a collaborative system: Photovoltaic power plant and electric vehicle fleet
Simultaneous upcoming of photovoltaic generation and electric vehicles increases constraints on electric power system. This paper explores the possible synergy between these players so as to jointly improve the production predictability while ensuring a low carbon mobility. First a context is defined for this collaboration. It consists in the association of a photovoltaic producer and some electric vehicles owners so as to both manage the EV recharge and meet a day-ahead production commitment. Several currently studied questions such as commitment strategies or optimal charging can be transposed into the proposed context called collaborative system. Here, we mainly focus on its sizing in terms of PV rated power and number of vehicles. A simplified model of the system is thus realised, including a day ahead commitment and an optimal vehicle charging planning, based on deterministic vehicle characteristics. First results show a strong influence of the sizing on the potential added value of vehicles in this association. Then, we assess the impact of day-ahead production forecast quality by comparing persistence forecast with some meteorological data. It appears that other things remaining equal, an imprecise forecast will increase the optimal number of vehicles that are supposed to get into the collaborative system. Finally, the robustness of the charging planning is investigated.
- 1 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 37, 1-9
Preliminary sizing of a collaborative system: Photovoltaic power plant and electric vehicle fleet
Simultaneous upcoming of photovoltaic generation and electric vehicles increases constraints on electric power system. This paper explores the possible synergy between these players so as to jointly improve the production predictability while ensuring a low carbon mobility. First a context is defined for this collaboration. It consists in the association of a photovoltaic producer and some electric vehicles owners so as to both manage the EV recharge and meet a day-ahead production commitment. Several currently studied questions such as commitment strategies or optimal charging can be transposed into the proposed context called collaborative system. Here, we mainly focus on its sizing in terms of PV rated power and number of vehicles. A simplified model of the system is thus realised, including a day ahead commitment and an optimal vehicle charging planning, based on deterministic vehicle characteristics. First results show a strong influence of the sizing on the potential added value of vehicles in this association. Then, we assess the impact of day-ahead production forecast quality by comparing persistence forecast with some meteorological data. It appears that other things remaining equal, an imprecise forecast will increase the optimal number of vehicles that are supposed to get into the collaborative system. Finally, the robustness of the charging planning is investigated.