Eddy Walther Hansen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eddy Walther Hansen has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Han Zhu
University of Oslo
2 shared publicationsAlireza Hassani
Department of Chemistry, University of Oslo, Oslo, Norway
1 shared publicationAnne Falk Øgaard
NIBIO, Norwegian Institute of Bioeconomy Research, Ås, Norway
1 shared publicationBing Zhou
Tongji Univ, Coll Mat Sci & Engn, Shanghai 200092, Peoples R China
1 shared publicationBjørg Egelandsdal
1 shared publication- Carlos Alberto González Murillo
Universidad Nacional de Colombia, Facultad de Ingeniería, Departamento de Ingeniería Civil y Agrícola, Bogota
1 shared publication
Latest Publications
- Open Access
- 27 December 2023
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 55 (4) , 477-496
Probing the “Dead-Time” in NMR by Combining Single Pulse and Solid Echo Experiments Followed by a Global Model Fit Analysis
The main question addressed in this work is how to probe the “effective dead-time” in an NMR instrument, i.e., the time needed to blank the receiver after an rf-pulse excitation to prevent damage to the receiver and to avoid any distortion of the NMR signal being sampled. The strategy is to design a suitable FID-model to fit the single pulse excitation (SPE) and solid echo pulse (SEPS) data (on solid Tricosane) using a Global model-fit analysis technique. The derived dead time is discussed with respect to sampling temperature (25–40 °C) and—in particular—with respect to the number of SEPS data involved in the Global fit analysis by applying the Bayesian Information Criterion (BIC) in combination with more traditional statistical analysis. It is concluded that the “effective dead time” can be determined within a standard error of less than 2.5%.
- 27 December 2023
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 55 (4) , 477-496
Open AccessProbing the “Dead-Time” in NMR by Combining Single Pulse and Solid Echo Experiments Followed by a Global Model Fit Analysis
The main question addressed in this work is how to probe the “effective dead-time” in an NMR instrument, i.e., the time needed to blank the receiver after an rf-pulse excitation to prevent damage to the receiver and to avoid any distortion of the NMR signal being sampled. The strategy is to design a suitable FID-model to fit the single pulse excitation (SPE) and solid echo pulse (SEPS) data (on solid Tricosane) using a Global model-fit analysis technique. The derived dead time is discussed with respect to sampling temperature (25–40 °C) and—in particular—with respect to the number of SEPS data involved in the Global fit analysis by applying the Bayesian Information Criterion (BIC) in combination with more traditional statistical analysis. It is concluded that the “effective dead time” can be determined within a standard error of less than 2.5%.
- Open Access
- 6 December 2021
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 53 (2) , 417-439
Quantitative Evaluation of Phase Distribution in UHMWPE as Derived from a Combined Use of NMR FID Analysis and Monte Carlo Simulation
A new and robust statistical approach is explored with the objective to derive quantitative and reliable information on the molecular dynamics within distinct domains (crystalline, intermediate and amorphous domains) of ultra-high molecular weight polyethylene (UHMWPE). The method consists of a critical evaluation of the free induction decay (FID) model, which is used to generate synthetic FID with a predefined signal-to-noise ratio by Monte Carlo simulations. The application of the method is demonstrated for three UHMWPE samples. A subsequent model fitting of their synthetic FIDs revealed a unique correlation between the error, i.e., standard deviation, of the derived parameters and the FID signal-to-noise ratio (SNRFID). Moreover, it was found that the method can be used to estimate the minimum required sampling time to obtain reliable parameter estimation of the FID model to experimental data.
- 6 December 2021
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 53 (2) , 417-439
Open AccessQuantitative Evaluation of Phase Distribution in UHMWPE as Derived from a Combined Use of NMR FID Analysis and Monte Carlo Simulation
A new and robust statistical approach is explored with the objective to derive quantitative and reliable information on the molecular dynamics within distinct domains (crystalline, intermediate and amorphous domains) of ultra-high molecular weight polyethylene (UHMWPE). The method consists of a critical evaluation of the free induction decay (FID) model, which is used to generate synthetic FID with a predefined signal-to-noise ratio by Monte Carlo simulations. The application of the method is demonstrated for three UHMWPE samples. A subsequent model fitting of their synthetic FIDs revealed a unique correlation between the error, i.e., standard deviation, of the derived parameters and the FID signal-to-noise ratio (SNRFID). Moreover, it was found that the method can be used to estimate the minimum required sampling time to obtain reliable parameter estimation of the FID model to experimental data.
- 1 August 2019
- Published by Elsevier in Applied Surface Science
- Vol. 484, 1154-1160
Interfacial water in mesopores and its implications to the surface features – A solid state NMR study
- 1 August 2019
- Published by Elsevier in Applied Surface Science
- Vol. 484, 1154-1160
Interfacial water in mesopores and its implications to the surface features – A solid state NMR study
- 8 September 2016
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 47 (11) , 1255-1272
Discrete and Continuous Spin–Spin Relaxation Rate Distributions Derived from CPMG NMR Response Curves: a Comparative Analysis Exemplified by Water in Meat
- 8 September 2016
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 47 (11) , 1255-1272
Discrete and Continuous Spin–Spin Relaxation Rate Distributions Derived from CPMG NMR Response Curves: a Comparative Analysis Exemplified by Water in Meat
- 1 September 2016
- Published by Wolters Kluwer Health in Soil Science
- Vol. 181 (9/10) , 446-456
The Effect of the Soil Properties on Adsorption, Single-Point Desorption, and Degradation of Chlorpyrifos in Two Agricultural Soil Profiles From Colombia
- 1 September 2016
- Published by Wolters Kluwer Health in Soil Science
- Vol. 181 (9/10) , 446-456
The Effect of the Soil Properties on Adsorption, Single-Point Desorption, and Degradation of Chlorpyrifos in Two Agricultural Soil Profiles From Colombia
- 1 April 2016
- Published by Elsevier in Journal of Food Engineering
- Vol. 175, 51-57
Evaluating nuclear magnetic resonance (NMR) as a robust reference method for online spectroscopic measurement of water holding capacity (WHC)
- 1 April 2016
- Published by Elsevier in Journal of Food Engineering
- Vol. 175, 51-57
Evaluating nuclear magnetic resonance (NMR) as a robust reference method for online spectroscopic measurement of water holding capacity (WHC)
- 5 October 2015
- Published by Springer Nature in Nutrient Cycling in Agroecosystems
- Vol. 103 (2) , 167-185
Waste products as alternative phosphorus fertilisers part I: inorganic P species affect fertilisation effects depending on soil pH
- 5 October 2015
- Published by Springer Nature in Nutrient Cycling in Agroecosystems
- Vol. 103 (2) , 167-185
Waste products as alternative phosphorus fertilisers part I: inorganic P species affect fertilisation effects depending on soil pH