Elisangela Ferretti Manffra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elisangela Ferretti Manffra has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Gisele Francini Devetak
Centro de Estudos do Comportamento Motor, Departamento de Educação Física, Setor de Ciências Biológicas, Universidade Federal do Paraná, Rua Coronel Heráclito dos Santos, 100, Centro Politécnico, Jardim das Américas, Curitiba 19011, Paraná, Brazil
4 shared publications - Cinthia Bittencourt Spricigo
PUCPR
3 shared publications - Dielise Debona Iucksch
Postgraduate Program in Physical Education, Federal University of Parana, Curitiba 81531-980, Brazil
3 shared publications - Suzane Ketlyn Martello
Hospital Erasto Gaertner
3 shared publications - Tatiane Caroline Boumer
Pontifícia Universidade Católica do Paraná, Brasil
3 shared publications - Cynthia Maria Rocha Dutra2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Fisioterapia em Movimento
- Vol. 39
Skeletal muscle assessment in older women with osteoporosis
Introduction: Older women experience higher rates of falls, musculoskeletal diseases, and muscle loss, leading to functional limitations. The relationships between different muscle assessment methods and physical function in older women with osteoporosis remain insufficiently explored. Objective: To explore the agreement between bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA) for skeletal muscle mass assessment and the associations of ultrasound-derived and anthropometric muscle measures with physical function in older women with osteoporosis. Muscle quality (MQ) was evaluated as a secondary outcome. Methods: This exploratory cross-sectional study included 11 older women with osteoporo-sis (76.5 ± 8.9 years). Appendicular skeletal muscle mass (ASM) was assessed using BIA and DXA. Vastus lateralis muscle architecture was evaluated by ultrasound, and thigh circumference was measured anthropometrically. Muscle strength, lower-limb power, gait speed, Timed Up and Go, and the Short Physical Performance Battery were assessed. MQ was calculated as the ratio of handgrip strength to ASM. Results: No agreement was observed between BIA and DXA for ASM. Muscle thickness was positively correlated with handgrip strength (ρ = 0.644; p = 0.033), and fascicle length was positively correlated with gait speed (ρ = 0.617; p = 0.043). MQ differed ac-cording to the method used to estimate muscle mass, with lower values using BIA than DXA (1.52 ± 0.47 vs. 1.81 ± 0.50; p = 0.001 ). Conclusion: In this exploratory sample, agreement between BIA and DXA for skeletal muscle mass assessment was low. Ultrasound-derived muscle measures showed positive associations with selected indicators of physical function, whereas MQ estimates varied according to the method used to assess muscle mass.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Fisioterapia em Movimento
- Vol. 39
Open AccessSkeletal muscle assessment in older women with osteoporosis
Introduction: Older women experience higher rates of falls, musculoskeletal diseases, and muscle loss, leading to functional limitations. The relationships between different muscle assessment methods and physical function in older women with osteoporosis remain insufficiently explored. Objective: To explore the agreement between bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA) for skeletal muscle mass assessment and the associations of ultrasound-derived and anthropometric muscle measures with physical function in older women with osteoporosis. Muscle quality (MQ) was evaluated as a secondary outcome. Methods: This exploratory cross-sectional study included 11 older women with osteoporo-sis (76.5 ± 8.9 years). Appendicular skeletal muscle mass (ASM) was assessed using BIA and DXA. Vastus lateralis muscle architecture was evaluated by ultrasound, and thigh circumference was measured anthropometrically. Muscle strength, lower-limb power, gait speed, Timed Up and Go, and the Short Physical Performance Battery were assessed. MQ was calculated as the ratio of handgrip strength to ASM. Results: No agreement was observed between BIA and DXA for ASM. Muscle thickness was positively correlated with handgrip strength (ρ = 0.644; p = 0.033), and fascicle length was positively correlated with gait speed (ρ = 0.617; p = 0.043). MQ differed ac-cording to the method used to estimate muscle mass, with lower values using BIA than DXA (1.52 ± 0.47 vs. 1.81 ± 0.50; p = 0.001 ). Conclusion: In this exploratory sample, agreement between BIA and DXA for skeletal muscle mass assessment was low. Ultrasound-derived muscle measures showed positive associations with selected indicators of physical function, whereas MQ estimates varied according to the method used to assess muscle mass.
- Open Access
- 1 August 2025
- Published by MDPI AG in Biomechanics
- Vol. 5 (3) , 53
Evolution of Gait Biomechanics During a Nine-Month Exercise Program for Parkinson’s Disease: An Interventional Cohort Study
It is well established that combining exercise with medication may benefit functionality in individuals with PD (Parkinson’s disease). However, the long-term evolution of gait biomechanics under this combination remains poorly understood. Objectives: This study aims to analyze the evolution of spatiotemporal gait parameters, kinetics, and kinematics throughout a long-term exercise program conducted in water and on dry land. Methods: We have compared the trajectories of biomechanical variables across the treatment phases using statistical parametric mapping (SPM). A cohort of fourteen individuals with PD (mean age: 65.6 ± 12.1 years) participated in 24 sessions of aquatic exercises over three months, followed by a three-month retention phase, and then 24 additional sessions of land-based exercises. Three-dimensional gait data and spatiotemporal parameters were collected before and after each phase. Two-way ANOVA with repeated measures was used to compare spatiotemporal parameters. Results: The walking speed increased while the duration of the double support phase decreased. Additionally, the knee extensor moment consistently increased in the entire interval from midstance to midswing (20% to 70% of the stride period), approaching normal gait patterns. Regarding kinematics, significant increases were observed in both hip and knee flexion angles. Furthermore, the abnormal ankle dorsiflexion observed at the foot strike disappeared. Conclusions: These findings collectively suggest positive adaptations in gait biomechanics during the observation period.
- 1 August 2025
- Published by MDPI AG in Biomechanics
- Vol. 5 (3) , 53
Open AccessEvolution of Gait Biomechanics During a Nine-Month Exercise Program for Parkinson’s Disease: An Interventional Cohort Study
It is well established that combining exercise with medication may benefit functionality in individuals with PD (Parkinson’s disease). However, the long-term evolution of gait biomechanics under this combination remains poorly understood. Objectives: This study aims to analyze the evolution of spatiotemporal gait parameters, kinetics, and kinematics throughout a long-term exercise program conducted in water and on dry land. Methods: We have compared the trajectories of biomechanical variables across the treatment phases using statistical parametric mapping (SPM). A cohort of fourteen individuals with PD (mean age: 65.6 ± 12.1 years) participated in 24 sessions of aquatic exercises over three months, followed by a three-month retention phase, and then 24 additional sessions of land-based exercises. Three-dimensional gait data and spatiotemporal parameters were collected before and after each phase. Two-way ANOVA with repeated measures was used to compare spatiotemporal parameters. Results: The walking speed increased while the duration of the double support phase decreased. Additionally, the knee extensor moment consistently increased in the entire interval from midstance to midswing (20% to 70% of the stride period), approaching normal gait patterns. Regarding kinematics, significant increases were observed in both hip and knee flexion angles. Furthermore, the abnormal ankle dorsiflexion observed at the foot strike disappeared. Conclusions: These findings collectively suggest positive adaptations in gait biomechanics during the observation period.
- Open Access
- 5 February 2024
- Published by EDIPUCRS in PAJAR - Pan-American Journal of Aging Research
- Vol. 12 (1) , e45597
Prevalência da fragilidade multidimensional e risco de sarcopenia em pessoas idosas admitidas em um hospital de média complexidade
Objetivo: conhecer a prevalência da fragilidade multidimensional e risco de sarcopenia em pessoas idosas no momento da admissão hospitalar. Método: estudo transversal, quantitativo e retrospectivo. Foram coletadas informações referentes a uma avaliação física e funcional realizada na admissão hospitalar: Índice de Vulnerabilidade Clínico-Funcional-20, Teste Muscular Manual Medical Research Council, Short Physical Performance Battery e SARC-F+CP. Resultados: a amostra foi composta por 1780 prontuários de pessoas idosas internadas em hospital público no Sul do Brasil divididas em dois grupos: 60-79 anos (n=635) e ≥80 anos (n=1145), no período de agosto de 2019 a março de 2020. Entre pessoas idosas com 60-79 anos: 65,7% (n=417) são frágeis, 32,9% (n=209) apresentam fraqueza muscular, 61,7% (n=392) são incapazes ou tem desempenho físico muito ruim e 28,5% (n=343) apresentam risco de sarcopenia. Pessoas idosas com ≥80 anos: 87,2% (n=999) são frágeis, 45,2% (n=518) apresentam fraqueza muscular, 83,9% (n=961) apresentam desempenho físico muito ruim ou são incapazes e 71,5% (n=862) têm risco de sarcopenia. Conclusão: há prevalência da fragilidade multidimensional, fraqueza muscular periférica, incapacidade em atividades de desempenho físico e riscos de sarcopenia entre pessoas idosas hospitalizadas.
- 5 February 2024
- Published by EDIPUCRS in PAJAR - Pan-American Journal of Aging Research
- Vol. 12 (1) , e45597
Open AccessPrevalência da fragilidade multidimensional e risco de sarcopenia em pessoas idosas admitidas em um hospital de média complexidade
Objetivo: conhecer a prevalência da fragilidade multidimensional e risco de sarcopenia em pessoas idosas no momento da admissão hospitalar. Método: estudo transversal, quantitativo e retrospectivo. Foram coletadas informações referentes a uma avaliação física e funcional realizada na admissão hospitalar: Índice de Vulnerabilidade Clínico-Funcional-20, Teste Muscular Manual Medical Research Council, Short Physical Performance Battery e SARC-F+CP. Resultados: a amostra foi composta por 1780 prontuários de pessoas idosas internadas em hospital público no Sul do Brasil divididas em dois grupos: 60-79 anos (n=635) e ≥80 anos (n=1145), no período de agosto de 2019 a março de 2020. Entre pessoas idosas com 60-79 anos: 65,7% (n=417) são frágeis, 32,9% (n=209) apresentam fraqueza muscular, 61,7% (n=392) são incapazes ou tem desempenho físico muito ruim e 28,5% (n=343) apresentam risco de sarcopenia. Pessoas idosas com ≥80 anos: 87,2% (n=999) são frágeis, 45,2% (n=518) apresentam fraqueza muscular, 83,9% (n=961) apresentam desempenho físico muito ruim ou são incapazes e 71,5% (n=862) têm risco de sarcopenia. Conclusão: há prevalência da fragilidade multidimensional, fraqueza muscular periférica, incapacidade em atividades de desempenho físico e riscos de sarcopenia entre pessoas idosas hospitalizadas.
- 4 January 2024
- Published by Springer Nature
- p. 134-144
Joint Coordination to Maintain Postural Balance Differs Between Preferred and Non-preferred Lower Limbs
- 4 January 2024
- Published by Springer Nature
- p. 134-144
Joint Coordination to Maintain Postural Balance Differs Between Preferred and Non-preferred Lower Limbs
- 4 January 2024
- Published by Springer Nature
- p. 68-77
Computational Modeling of the Pendulum Test to Simulate Spasticity in the Elbow Joint
- 4 January 2024
- Published by Springer Nature
- p. 68-77
Computational Modeling of the Pendulum Test to Simulate Spasticity in the Elbow Joint
- 28 May 2023
- Published by Taylor & Francis in Journal of Motor Behavior
- Vol. 55 (4) , 384-393
Strategies Adopted by Stroke Patients to Maintain Balance in Dynamic Tasks in a Video Game
Postural instability affects motor tasks after a stroke. We investigated the strategies used to maintain balance during quiet standing posture and dynamic tasks in a video game. Sixteen stroke volunteers (12 males, 56 ± 9 years, post-stroke time 35 ± 10 months) and sixteen matched healthy volunteers had their biomechanical data collected to obtain the variables: center of mass, base of support, margin of stability, and weight symmetry. Healthy individuals and stroke patients showed similar dynamic stability. However, they adopted different motor strategies to achieve this: healthy individuals increased their base of support as they progressed to more challenging tasks, and stroke volunteers maintained the same base. The margin of stability of stroke volunteers was correlated with the MiniBEST scale.
- 28 May 2023
- Published by Taylor & Francis in Journal of Motor Behavior
- Vol. 55 (4) , 384-393
Strategies Adopted by Stroke Patients to Maintain Balance in Dynamic Tasks in a Video Game
Postural instability affects motor tasks after a stroke. We investigated the strategies used to maintain balance during quiet standing posture and dynamic tasks in a video game. Sixteen stroke volunteers (12 males, 56 ± 9 years, post-stroke time 35 ± 10 months) and sixteen matched healthy volunteers had their biomechanical data collected to obtain the variables: center of mass, base of support, margin of stability, and weight symmetry. Healthy individuals and stroke patients showed similar dynamic stability. However, they adopted different motor strategies to achieve this: healthy individuals increased their base of support as they progressed to more challenging tasks, and stroke volunteers maintained the same base. The margin of stability of stroke volunteers was correlated with the MiniBEST scale.
- Open Access
- 27 February 2023
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 5, 1122245
Effects of the radio electric asymmetric conveyer (REAC) on motor disorders: An integrative review
Introduction: The radio electric asymmetric conveyer (REAC) is a technology that has the purpose of restoring the cellular polarity triggering the rebalancing of the endogenous bioelectric field, which considering the neurological dysfunctions, affects the neural communication mechanisms. The studies published so far show that the REAC neuromodulation technology has positive effects in treating these dysfunctions, with the principles of endogenous bioelectricity as a basis to achieve these effects.Objectives: This study aims to review the literature that explored the effects of REAC protocols on motor control and to identify which mechanisms would be involved.Materials and methods: This integrative review considered studies that used REAC as a therapeutic intervention directed at human motor control and experimental research with animals that applied REAC to obtain effects related to motor behavior.Results: Ten articles were included, eight clinical and two experimental studies. The clinical studies used the neuro postural optimization (NPO) protocol in 473 patients, of which 53 were healthy subjects, 91 were Alzheimer's disease patients, 128 were patients with atypical swallowing, 12 subjects with neurological diseases, and 189 were without the specification of disease. The experimental studies used the antalgic neuromodulation and neurodegeneration protocols in animal models.Conclusion: The information integrated in this review made it possible to consider REAC technology a promising resource for treating motor control dysfunctions. It is possible to infer that the technology promotes functional optimization of neuronal circuits that may be related to more efficient strategies to perform motor tasks.
- 27 February 2023
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 5, 1122245
Open AccessEffects of the radio electric asymmetric conveyer (REAC) on motor disorders: An integrative review
Introduction: The radio electric asymmetric conveyer (REAC) is a technology that has the purpose of restoring the cellular polarity triggering the rebalancing of the endogenous bioelectric field, which considering the neurological dysfunctions, affects the neural communication mechanisms. The studies published so far show that the REAC neuromodulation technology has positive effects in treating these dysfunctions, with the principles of endogenous bioelectricity as a basis to achieve these effects.Objectives: This study aims to review the literature that explored the effects of REAC protocols on motor control and to identify which mechanisms would be involved.Materials and methods: This integrative review considered studies that used REAC as a therapeutic intervention directed at human motor control and experimental research with animals that applied REAC to obtain effects related to motor behavior.Results: Ten articles were included, eight clinical and two experimental studies. The clinical studies used the neuro postural optimization (NPO) protocol in 473 patients, of which 53 were healthy subjects, 91 were Alzheimer's disease patients, 128 were patients with atypical swallowing, 12 subjects with neurological diseases, and 189 were without the specification of disease. The experimental studies used the antalgic neuromodulation and neurodegeneration protocols in animal models.Conclusion: The information integrated in this review made it possible to consider REAC technology a promising resource for treating motor control dysfunctions. It is possible to infer that the technology promotes functional optimization of neuronal circuits that may be related to more efficient strategies to perform motor tasks.
- 21 October 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 144, 111353
Does the number of steps needed for UCM gait analysis differs between healthy and stroke?
- 21 October 2022
- Published by Elsevier in Journal of Biomechanics
- Vol. 144, 111353
Does the number of steps needed for UCM gait analysis differs between healthy and stroke?
- Open Access
- 1 October 2021
- Published by FapUNIFESP (SciELO) in Fisioterapia e Pesquisa
- Vol. 28 (4) , 369-375
Estabilidade dinâmica de pessoas com AVE durante o movimento de cabeceio simulado em um jogo digital
RESUMO A estabilidade postural é um objetivo de tratamento na fisioterapia que pode ser alcançado por meio de exercícios de transferência de peso bilateral. Os jogos digitais surgem como alternativa para execução desses exercícios, mas sua avaliação ainda necessita de aprimoramento. Propõe-se aqui o uso de variáveis biomecânicas para verificar o comportamento da estabilidade postural dinâmica durante um movimento de cabeceio, simulado por um jogo digital com diferentes exigências de velocidades. Para isso, 16 voluntários pós-acidente vascular encefálico (AVE) - 12 homens e 4 mulheres, com idade média de 56 anos - e 16 hígidos pareados por sexo e idade participaram da coleta experimental, na qual eles foram submetidos ao jogo digital “cabeceio”, que tem cinco níveis de velocidade, do mais lento ao mais rápido, com duração de 30 segundos cada. A partir dos sinais cinemáticos foi possível calcular os indicadores de interesse, a área da base de suporte e a margem de estabilidade, definida como a menor distância entre as bordas da base de suporte e a projeção vertical do centro de massa (CM) extrapolado, que considera a velocidade do CM. Os valores da base de suporte não apresentaram diferenças entre os níveis de velocidade do jogo, mas sim entre grupos. A margem de estabilidade não diferiu entre níveis e grupos. Os níveis de velocidade do jogo, possivelmente, não estimularam os voluntários a buscar estratégias diferentes para manter a estabilidade, como dar um passo, mas os fizeram adotar bases de suporte diferentes, sendo que indivíduos com AVE adotaram uma base de suporte menor do que a dos hígidos.
- 1 October 2021
- Published by FapUNIFESP (SciELO) in Fisioterapia e Pesquisa
- Vol. 28 (4) , 369-375
Open AccessEstabilidade dinâmica de pessoas com AVE durante o movimento de cabeceio simulado em um jogo digital
RESUMO A estabilidade postural é um objetivo de tratamento na fisioterapia que pode ser alcançado por meio de exercícios de transferência de peso bilateral. Os jogos digitais surgem como alternativa para execução desses exercícios, mas sua avaliação ainda necessita de aprimoramento. Propõe-se aqui o uso de variáveis biomecânicas para verificar o comportamento da estabilidade postural dinâmica durante um movimento de cabeceio, simulado por um jogo digital com diferentes exigências de velocidades. Para isso, 16 voluntários pós-acidente vascular encefálico (AVE) - 12 homens e 4 mulheres, com idade média de 56 anos - e 16 hígidos pareados por sexo e idade participaram da coleta experimental, na qual eles foram submetidos ao jogo digital “cabeceio”, que tem cinco níveis de velocidade, do mais lento ao mais rápido, com duração de 30 segundos cada. A partir dos sinais cinemáticos foi possível calcular os indicadores de interesse, a área da base de suporte e a margem de estabilidade, definida como a menor distância entre as bordas da base de suporte e a projeção vertical do centro de massa (CM) extrapolado, que considera a velocidade do CM. Os valores da base de suporte não apresentaram diferenças entre os níveis de velocidade do jogo, mas sim entre grupos. A margem de estabilidade não diferiu entre níveis e grupos. Os níveis de velocidade do jogo, possivelmente, não estimularam os voluntários a buscar estratégias diferentes para manter a estabilidade, como dar um passo, mas os fizeram adotar bases de suporte diferentes, sendo que indivíduos com AVE adotaram uma base de suporte menor do que a dos hígidos.
- 2 January 2021
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 38 (1) , 317-324
An additive manufacturing fabricated a split Pitot tube transducer for mechanical ventilator analyzers
Introduction Frequent calibration of ventilators and anesthesia machines might reduce the risk of death and of sequelae in patients under mechanical ventilation. However, ventilator analyzers might be difficult to purchase due to high cost or even in trade-restrictive scenarios, such as the COVID-19 pandemic. To alleviate this problem, the aim of this article is to present the design and characterization of a Pitot tube transducer fabricated with additive manufacturing (AM), to be used in ventilator analyzers. Method A split Pitot tube (SPT) transducer was designed using computer-aided design (CAD) and characterized using finite element method (FEM) simulations. Bernoulli’s equation was used to determine a transducer discharge coefficient. The sensor was fabricated with the acrylonitrile butadiene styrene (ABS) thermoplastic, with the fused deposition modeling after properly configuring the 3D printer. Results According to the simulated velocity profile, the transducer does not impose excessive resistance to the flow and the pressure profile revealed that the pressure is constant and stable inside the pressure lines. The characteristic curve of differential pressure (dP) versus flow is quadratic. For the minimal and maximal simulated flows 0.01 to 300 L/min, the corresponding dP values are 6.535·10−4 Pa and 13.178·103 Pa. Conclusion The split Pitot tube transducer developed here has appropriate characteristics for measuring air flows from mechanical ventilators, and the delivered pressures can be read by commercial electronic sensors. The AM is viable for fabricating the transducer, and the printing time is considerably low compared to that necessary to order a similar part from a sales representative.
- 2 January 2021
- Published by Springer Nature in Research on Biomedical Engineering
- Vol. 38 (1) , 317-324
An additive manufacturing fabricated a split Pitot tube transducer for mechanical ventilator analyzers
Introduction Frequent calibration of ventilators and anesthesia machines might reduce the risk of death and of sequelae in patients under mechanical ventilation. However, ventilator analyzers might be difficult to purchase due to high cost or even in trade-restrictive scenarios, such as the COVID-19 pandemic. To alleviate this problem, the aim of this article is to present the design and characterization of a Pitot tube transducer fabricated with additive manufacturing (AM), to be used in ventilator analyzers. Method A split Pitot tube (SPT) transducer was designed using computer-aided design (CAD) and characterized using finite element method (FEM) simulations. Bernoulli’s equation was used to determine a transducer discharge coefficient. The sensor was fabricated with the acrylonitrile butadiene styrene (ABS) thermoplastic, with the fused deposition modeling after properly configuring the 3D printer. Results According to the simulated velocity profile, the transducer does not impose excessive resistance to the flow and the pressure profile revealed that the pressure is constant and stable inside the pressure lines. The characteristic curve of differential pressure (dP) versus flow is quadratic. For the minimal and maximal simulated flows 0.01 to 300 L/min, the corresponding dP values are 6.535·10−4 Pa and 13.178·103 Pa. Conclusion The split Pitot tube transducer developed here has appropriate characteristics for measuring air flows from mechanical ventilators, and the delivered pressures can be read by commercial electronic sensors. The AM is viable for fabricating the transducer, and the printing time is considerably low compared to that necessary to order a similar part from a sales representative.