Ang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ang Li has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Xingde Li
Johns Hopkins University
10 shared publications Honghua Guan
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
7 shared publications- Hyeon-Cheol Park
Johns Hopkins University
5 shared publications - Wenxuan Liang
School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui 230026, PR China; School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230026, PR China; Suzhou Institute for Advanced Research, University of Science and Technology of China, Suzhou, Jiangsu 215123, PR China
5 shared publications Yung-Tian A. Gau
Solomon H. Snyder Department of Neuroscience, Johns Hopkins University School of Medicine, Baltimore, USA
5 shared publicationsHui Lu
Department of Pharmacology and Physiology, School of Medicine and Health Sciences, George Washington University, Washington, USA
4 shared publications
Latest Publications
- Open Access
- 3 October 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1
Author Correction: Deep-learning two-photon fiberscopy for video-rate brain imaging in freely-behaving mice
- 3 October 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1
Open AccessAuthor Correction: Deep-learning two-photon fiberscopy for video-rate brain imaging in freely-behaving mice
- 4 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 238-246
Direct Visualization and Quantitative Imaging of Small Airway Anatomy Using Deep Learning Assisted Diffractive OCT
Objective/background: In vivo imaging and quantification of the microstructures of small airways in three dimensions (3D) allows a better understanding and management of airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD). At present, the resolution and contrast of the currently available conventional optical coherence tomography (OCT) imaging technologies operating at 1300 nm remain challenging to directly visualize the fine microstructures of small airways in vivo . Methods: We developed an ultrahigh-resolution diffractive endoscopic OCT at 800 nm to afford a resolving power of 1.7 μm (in tissue) with an improved contrast and a custom deep residual learning based image segmentation framework to perform accurate and automated 3D quantification of airway anatomy. Results: The 800-nm diffractive OCT enabled the direct delineation of the structural components in the small airway wall in vivo . We further first demonstrated the 3D anatomic quantification of critical tissue compartments of small airways in sheep using the automated segmentation method. Conclusion: The deep learning assisted diffractive OCT provides a unique ability to access the small airways, directly visualize and quantify the important tissue compartments, such as airway smooth muscle, in the airway wall in vivo in 3D. Significance: These pilot results suggest a potential technology for calculating volumetric measurements of small airways in patients in vivo .
- 4 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (1) , 238-246
Direct Visualization and Quantitative Imaging of Small Airway Anatomy Using Deep Learning Assisted Diffractive OCT
Objective/background: In vivo imaging and quantification of the microstructures of small airways in three dimensions (3D) allows a better understanding and management of airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD). At present, the resolution and contrast of the currently available conventional optical coherence tomography (OCT) imaging technologies operating at 1300 nm remain challenging to directly visualize the fine microstructures of small airways in vivo . Methods: We developed an ultrahigh-resolution diffractive endoscopic OCT at 800 nm to afford a resolving power of 1.7 μm (in tissue) with an improved contrast and a custom deep residual learning based image segmentation framework to perform accurate and automated 3D quantification of airway anatomy. Results: The 800-nm diffractive OCT enabled the direct delineation of the structural components in the small airway wall in vivo . We further first demonstrated the 3D anatomic quantification of critical tissue compartments of small airways in sheep using the automated segmentation method. Conclusion: The deep learning assisted diffractive OCT provides a unique ability to access the small airways, directly visualize and quantify the important tissue compartments, such as airway smooth muscle, in the airway wall in vivo in 3D. Significance: These pilot results suggest a potential technology for calculating volumetric measurements of small airways in patients in vivo .
- Open Access
- 22 June 2022
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 10 (6S) , 19
29. Mechanical Stretch Mobilizes Lgr6+ Epidermal Stem Cells to Drive Skin Growth
- 22 June 2022
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 10 (6S) , 19
Open Access29. Mechanical Stretch Mobilizes Lgr6+ Epidermal Stem Cells to Drive Skin Growth
- Open Access
- 22 March 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-9
Deep-learning two-photon fiberscopy for video-rate brain imaging in freely-behaving mice
Scanning two-photon (2P) fiberscopes (also termed endomicroscopes) have the potential to transform our understanding of how discrete neural activity patterns result in distinct behaviors, as they are capable of high resolution, sub cellular imaging yet small and light enough to allow free movement of mice. However, their acquisition speed is currently suboptimal, due to opto-mechanical size and weight constraints. Here we demonstrate significant advances in 2P fiberscopy that allow high resolution imaging at high speeds (26 fps) in freely-behaving mice. A high-speed scanner and a down-sampling scheme are developed to boost imaging speed, and a deep learning (DL) algorithm is introduced to recover image quality. For the DL algorithm, a two-stage learning transfer strategy is established to generate proper training datasets for enhancing the quality of in vivo images. Implementation enables video-rate imaging at ~26 fps, representing 10-fold improvement in imaging speed over the previous 2P fiberscopy technology while maintaining a high signal-to-noise ratio and imaging resolution. This DL-assisted 2P fiberscope is capable of imaging the arousal-induced activity changes in populations of layer2/3 pyramidal neurons in the primary motor cortex of freely-behaving mice, providing opportunities to define the neural basis of behavior.
- 22 March 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-9
Open AccessDeep-learning two-photon fiberscopy for video-rate brain imaging in freely-behaving mice
Scanning two-photon (2P) fiberscopes (also termed endomicroscopes) have the potential to transform our understanding of how discrete neural activity patterns result in distinct behaviors, as they are capable of high resolution, sub cellular imaging yet small and light enough to allow free movement of mice. However, their acquisition speed is currently suboptimal, due to opto-mechanical size and weight constraints. Here we demonstrate significant advances in 2P fiberscopy that allow high resolution imaging at high speeds (26 fps) in freely-behaving mice. A high-speed scanner and a down-sampling scheme are developed to boost imaging speed, and a deep learning (DL) algorithm is introduced to recover image quality. For the DL algorithm, a two-stage learning transfer strategy is established to generate proper training datasets for enhancing the quality of in vivo images. Implementation enables video-rate imaging at ~26 fps, representing 10-fold improvement in imaging speed over the previous 2P fiberscopy technology while maintaining a high signal-to-noise ratio and imaging resolution. This DL-assisted 2P fiberscope is capable of imaging the arousal-induced activity changes in populations of layer2/3 pyramidal neurons in the primary motor cortex of freely-behaving mice, providing opportunities to define the neural basis of behavior.
- 14 June 2021
- Published by Optica Publishing Group in Optica
- Vol. 8 (6) , 870-879
Twist-free ultralight two-photon fiberscope enabling neuroimaging on freely rotating/walking mice
Lightweight and head-mountable scanning nonlinear fiberscope technologies offer an exciting opportunity for enabling mechanistic exploration of ensemble neural activities with subcellular resolution on freely behaving rodents. The tether of the fiberscope, consisting of an optical fiber and scanner drive wires, however, restricts the mouse’s movement and consequently precludes free rotation and limits the freedom of walking. Here we present the first twist-free two-photon fiberscope technology for enabling neuroimaging on freely rotating/walking mice. The technology equips a scanning fiberscope with active rotational tracking and compensation capabilities through an optoelectrical commutator (OEC) to allow the animal to rotate and walk in arbitrary patterns during two-photon fluorescence (TPF) imaging of neural activities. The OEC provides excellent optical coupling stability ( < ± 1 % fluctuation during rotation) and an extremely high torque sensitivity ( < 8 m N ⋅ m ). In addition, the new technology is equipped with a custom grating and prism to effectively manage the temporal properties of the femtosecond excitation pulses through the fiber-optic system, which improved neuroimaging signal by more than 2 X . This TPF fiberscope imaging platform has been tested for in vivo imaging, and the results demonstrate that it enables reliable recording of calcium dynamics of more than 50 neurons simultaneously in the motor cortices of freely behaving mice in a twist-free fashion. With active tracking function of the OEC enabled, we observed considerable increase in both behavior and neural activities in the motor cortices of the mice during freely behaving neuroimaging experiments.
- 14 June 2021
- Published by Optica Publishing Group in Optica
- Vol. 8 (6) , 870-879
Twist-free ultralight two-photon fiberscope enabling neuroimaging on freely rotating/walking mice
Lightweight and head-mountable scanning nonlinear fiberscope technologies offer an exciting opportunity for enabling mechanistic exploration of ensemble neural activities with subcellular resolution on freely behaving rodents. The tether of the fiberscope, consisting of an optical fiber and scanner drive wires, however, restricts the mouse’s movement and consequently precludes free rotation and limits the freedom of walking. Here we present the first twist-free two-photon fiberscope technology for enabling neuroimaging on freely rotating/walking mice. The technology equips a scanning fiberscope with active rotational tracking and compensation capabilities through an optoelectrical commutator (OEC) to allow the animal to rotate and walk in arbitrary patterns during two-photon fluorescence (TPF) imaging of neural activities. The OEC provides excellent optical coupling stability ( < ± 1 % fluctuation during rotation) and an extremely high torque sensitivity ( < 8 m N ⋅ m ). In addition, the new technology is equipped with a custom grating and prism to effectively manage the temporal properties of the femtosecond excitation pulses through the fiber-optic system, which improved neuroimaging signal by more than 2 X . This TPF fiberscope imaging platform has been tested for in vivo imaging, and the results demonstrate that it enables reliable recording of calcium dynamics of more than 50 neurons simultaneously in the motor cortices of freely behaving mice in a twist-free fashion. With active tracking function of the OEC enabled, we observed considerable increase in both behavior and neural activities in the motor cortices of the mice during freely behaving neuroimaging experiments.
- Open Access
- 10 June 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (7) , 3992-4002
Minimizing OCT quantification error via a surface-tracking imaging probe
OCT-based quantitative tissue optical properties imaging is a promising technique for intraoperative brain cancer assessment. The attenuation coefficient analysis relies on the depth-dependent OCT intensity profile, thus sensitive to tissue surface positions relative to the imaging beam focus. However, it is almost impossible to maintain a steady tissue surface during intraoperative imaging due to the patient’s arterial pulsation and breathing, the operator’s motion, and the complex tissue surface geometry of the surgical cavity. In this work, we developed an intraoperative OCT imaging probe with a surface-tracking function to minimize the quantification errors in optical attenuation due to the tissue surface position variations. A compact OCT imaging probe was designed and engineered to have a long working distance of ∼ 41 mm and a large field of view of 4 × 4 mm2 while keeping the probe diameter small (9 mm) to maximize clinical versatility. A piezo-based linear motor was integrated with the imaging probe and controlled based upon real-time feedback of tissue surface position inferred from OCT images. A GPU-assisted parallel processing algorithm was implemented, enabling detection and tracking of tissue surface in real-time and successfully suppressing more than 90% of the typical physiologically induced motion range. The surface-tracking intraoperative OCT imaging probe could maintain a steady beam focus inside the target tissue regardless of the surface geometry or physiological motions and enabled to obtain tissue optical attenuation reliably for assessing brain cancer margins in challenging intraoperative settings.
- 10 June 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (7) , 3992-4002
Open AccessMinimizing OCT quantification error via a surface-tracking imaging probe
OCT-based quantitative tissue optical properties imaging is a promising technique for intraoperative brain cancer assessment. The attenuation coefficient analysis relies on the depth-dependent OCT intensity profile, thus sensitive to tissue surface positions relative to the imaging beam focus. However, it is almost impossible to maintain a steady tissue surface during intraoperative imaging due to the patient’s arterial pulsation and breathing, the operator’s motion, and the complex tissue surface geometry of the surgical cavity. In this work, we developed an intraoperative OCT imaging probe with a surface-tracking function to minimize the quantification errors in optical attenuation due to the tissue surface position variations. A compact OCT imaging probe was designed and engineered to have a long working distance of ∼ 41 mm and a large field of view of 4 × 4 mm2 while keeping the probe diameter small (9 mm) to maximize clinical versatility. A piezo-based linear motor was integrated with the imaging probe and controlled based upon real-time feedback of tissue surface position inferred from OCT images. A GPU-assisted parallel processing algorithm was implemented, enabling detection and tracking of tissue surface in real-time and successfully suppressing more than 90% of the typical physiologically induced motion range. The surface-tracking intraoperative OCT imaging probe could maintain a steady beam focus inside the target tissue regardless of the surface geometry or physiological motions and enabled to obtain tissue optical attenuation reliably for assessing brain cancer margins in challenging intraoperative settings.
- 24 February 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (5) , 1093-1096
Multicolor fiber-optic two-photon endomicroscopy for brain imaging
Visualizing activity patterns of distinct cell types during complex behaviors is essential to understand complex neural networks. It remains challenging to excite multiple fluorophores simultaneously so that different types of neurons can be imaged. In this Letter, we report a multicolor fiber-optic two-photon endomicroscopy platform in which two pulses from a Ti:sapphire laser and an optical parametric oscillator were synchronized and delivered through a single customized double-clad fiber to excite multiple chromophores. A third virtual wavelength could also be generated by spatial-temporal overlapping of the two pulses. The performance of the fiber-optic multicolor two-photon endomicroscope was demonstrated by in vivo imaging of a mouse cerebral cortex with “Brainbow” labeling.
- 24 February 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (5) , 1093-1096
Multicolor fiber-optic two-photon endomicroscopy for brain imaging
Visualizing activity patterns of distinct cell types during complex behaviors is essential to understand complex neural networks. It remains challenging to excite multiple fluorophores simultaneously so that different types of neurons can be imaged. In this Letter, we report a multicolor fiber-optic two-photon endomicroscopy platform in which two pulses from a Ti:sapphire laser and an optical parametric oscillator were synchronized and delivered through a single customized double-clad fiber to excite multiple chromophores. A third virtual wavelength could also be generated by spatial-temporal overlapping of the two pulses. The performance of the fiber-optic multicolor two-photon endomicroscope was demonstrated by in vivo imaging of a mouse cerebral cortex with “Brainbow” labeling.
- 30 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (12) , 3779-3787
Throughput-Speed Product Augmentation for Scanning Fiber-Optic Two-Photon Endomicroscopy
Compactness, among several others, is one unique and very attractive feature of a scanning fiber-optic two-photon endomicroscope. To increase the scanning area and the total number of resolvable pixels (i.e., the imaging throughput), it typically requires a longer cantilever which, however, leads to a much undesired, reduced scanning speed (and thus imaging frame rate). Herein we introduce a new design strategy for a fiber-optic scanning endomicroscope, where the overall numerical aperture (NA)or beam focusing power is distributed over two stages: 1) a mode-field focuser engineered at the tip of a double-clad fiber (DCF) cantilever to pre-amplify the single-mode core NA, and 2) a micro objective of a lower magnification (i.e., ~2× in this design) to achieve final tight beam focusing. This new design enables either an ~9-fold increase in imaging area (throughput) or an ~3-fold improvement in imaging frame rate when compared to traditional fiber-optic endomicroscope designs. The performance of an as-designed endomicroscope of an enhanced throughput-speed product was demonstrated by two representative applications: (1) high-resolution imaging of an internal organ (i.e., mouse kidney) in vivo over a large field of view without using any fluorescent contrast agents, and (2) real-time neural imaging by visualizing dendritic calcium dynamics in vivo with sub-second temporal resolution in GCaMP6m-expressing mouse brain. This cascaded NA amplification strategy is universal and can be readily adapted to other types of fiber-optic scanners in compact linear or nonlinear endomicroscopes.
- 30 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (12) , 3779-3787
Throughput-Speed Product Augmentation for Scanning Fiber-Optic Two-Photon Endomicroscopy
Compactness, among several others, is one unique and very attractive feature of a scanning fiber-optic two-photon endomicroscope. To increase the scanning area and the total number of resolvable pixels (i.e., the imaging throughput), it typically requires a longer cantilever which, however, leads to a much undesired, reduced scanning speed (and thus imaging frame rate). Herein we introduce a new design strategy for a fiber-optic scanning endomicroscope, where the overall numerical aperture (NA)or beam focusing power is distributed over two stages: 1) a mode-field focuser engineered at the tip of a double-clad fiber (DCF) cantilever to pre-amplify the single-mode core NA, and 2) a micro objective of a lower magnification (i.e., ~2× in this design) to achieve final tight beam focusing. This new design enables either an ~9-fold increase in imaging area (throughput) or an ~3-fold improvement in imaging frame rate when compared to traditional fiber-optic endomicroscope designs. The performance of an as-designed endomicroscope of an enhanced throughput-speed product was demonstrated by two representative applications: (1) high-resolution imaging of an internal organ (i.e., mouse kidney) in vivo over a large field of view without using any fluorescent contrast agents, and (2) real-time neural imaging by visualizing dendritic calcium dynamics in vivo with sub-second temporal resolution in GCaMP6m-expressing mouse brain. This cascaded NA amplification strategy is universal and can be readily adapted to other types of fiber-optic scanners in compact linear or nonlinear endomicroscopes.
- 1 July 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (13) , 3605-3608
High-speed fiber-optic scanning nonlinear endomicroscopy for imaging neuron dynamics in vivo
Fiber-optic-based two-photon fluorescence endomicroscopy is emerging as an enabling technology for in vivo histological imaging of internal organs and functional neuronal imaging on freely-behaving animals. However, high-speed imaging remains challenging due to the expense of miniaturization and lack of suited fast beam scanners. For many applications, a higher imaging speed is highly desired, especially for monitoring functional dynamics such as transient dendritic responses in neuroscience. This Letter reports the development of a fast fiber-optic scanning endo-microscope with an imaging speed higher than 26 frames/s. In vivo neural dynamics imaging with the high-speed endomicroscope was performed on a freely-behaving mouse over the primary motor cortex that expressed GCaMP6m. The results demonstrate its capability of real-time monitoring of transient neuronal dynamics with very fine temporal resolution.
- 1 July 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (13) , 3605-3608
High-speed fiber-optic scanning nonlinear endomicroscopy for imaging neuron dynamics in vivo
Fiber-optic-based two-photon fluorescence endomicroscopy is emerging as an enabling technology for in vivo histological imaging of internal organs and functional neuronal imaging on freely-behaving animals. However, high-speed imaging remains challenging due to the expense of miniaturization and lack of suited fast beam scanners. For many applications, a higher imaging speed is highly desired, especially for monitoring functional dynamics such as transient dendritic responses in neuroscience. This Letter reports the development of a fast fiber-optic scanning endo-microscope with an imaging speed higher than 26 frames/s. In vivo neural dynamics imaging with the high-speed endomicroscope was performed on a freely-behaving mouse over the primary motor cortex that expressed GCaMP6m. The results demonstrate its capability of real-time monitoring of transient neuronal dynamics with very fine temporal resolution.
- 5 September 2018
- Published by Wiley in Journal of Biophotonics
- Vol. 12 (1) , e201800229
A biopsy‐needle compatible varifocal multiphoton rigid probe for depth‐resolved optical biopsy
In this work, we report a biopsy‐needle compatible rigid probe, capable of performing three‐dimensional (3D) two‐photon optical biopsy. The probe has a small outer diameter of 1.75 mm and fits inside a gauge‐14 biopsy needle to reach internal organs. A carefully designed focus scanning mechanism has been implemented in the rigid probe, which, along with a rapid two‐dimensional MEMS scanner, enables 3D imaging. Fast image acquisition up to 10 frames per second is possible, dramatically reducing motion artifacts during in vivo imaging. Equipped with a high‐numerical aperture micro‐objective, the miniature rigid probe offers a high two‐photon resolution (0.833 × 6.11 μm, lateral × axial), a lateral field of view of 120 μm, and an axial focus tuning range of 200 μm. In addition to imaging of mouse internal organs and subcutaneous tumor in vivo, first‐of‐its‐kind depth‐resolved two‐photon optical biopsy of an internal organ has been successfully demonstrated on mouse kidney in vivo and in situ.
- 5 September 2018
- Published by Wiley in Journal of Biophotonics
- Vol. 12 (1) , e201800229
A biopsy‐needle compatible varifocal multiphoton rigid probe for depth‐resolved optical biopsy
In this work, we report a biopsy‐needle compatible rigid probe, capable of performing three‐dimensional (3D) two‐photon optical biopsy. The probe has a small outer diameter of 1.75 mm and fits inside a gauge‐14 biopsy needle to reach internal organs. A carefully designed focus scanning mechanism has been implemented in the rigid probe, which, along with a rapid two‐dimensional MEMS scanner, enables 3D imaging. Fast image acquisition up to 10 frames per second is possible, dramatically reducing motion artifacts during in vivo imaging. Equipped with a high‐numerical aperture micro‐objective, the miniature rigid probe offers a high two‐photon resolution (0.833 × 6.11 μm, lateral × axial), a lateral field of view of 120 μm, and an axial focus tuning range of 200 μm. In addition to imaging of mouse internal organs and subcutaneous tumor in vivo, first‐of‐its‐kind depth‐resolved two‐photon optical biopsy of an internal organ has been successfully demonstrated on mouse kidney in vivo and in situ.