BTBetul Tuncelli

Betul Tuncelli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Betul Tuncelli has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of air‐particle abrasion of Y‐TZPwith different particles using microstructural analysis

    by V Turp, D Sen, B Tuncelli, G Goller, M Özcan

    Background: This study evaluated the effect of air‐particle abrasion with different particle sizes on the surface roughness and phase transformation of yttria‐stabilized tetragonal zirconia ceramics (Y‐TZP).Methods: Eighty‐four Y‐TZPdiscs of 15 mm diameter and 1.0 mm thickness were fabricated. The samples were divided into four groups (n = 21): (1) air‐particle abrasion with 30 μm CoJet sand blast coating agent (CoJet, 3MESPE); (2) 50 μm Al2O3particles; (3) 110 μm Al2O3particles; and (4) 250 μm Al2O3particles. Each group was further divided into three subgroups each (n = 7) and treated for 5 seconds, 15 seconds and 30 seconds. Mean surface roughness was determined using a profilometer. The surfaces were analysed with a scanning electron microscope.XRDanalysis was employed and the relative amount of the monoclinic phase was calculated. The results were statistically analysed by two‐way analysis of variance (ANOVA, p < 0.05).Results: Air‐particle abrasion with 250 μm Al2O3particles for 30 seconds had the highest surface roughness (p < 0.001) and a significantly higher amount of monoclinic phase compared to air‐particle abrasion with 30 μm, 50 μm and 110 μm particles (p < 0.001).Conclusions: Duration and particle size of air‐particle abrasion affects the roughness and phase transformation of Y‐TZP. Longer treatment times with larger particles may result in degradation of material.


  • Open Access

    Evaluation of hardness and fracture toughness, coupled with microstructural analysis, of zirconia ceramics stored in environments with different pH values

    by Volkan Turp, Betul Tuncelli, Deniz Sen, Gultekin Goller

    The aim of this study was to evaluate the effects of pH changes in the oral cavity on the mechanical properties of zirconia and feldspathic ceramics. Bilayered zirconia-feldspathic samples were prepared from three different commercial brands of Y-TZP blocks: Zirkonzahn, Cercon, and Everest. Samples were stored in artificial saliva with different pH values (3.5, 7.0, and 10.0) for 10 days at 37°C. Flexural strength, Vickers hardness, and fracture toughness were calculated after samples were subjected to biaxial flexure test. Microstructural analysis of the materials was also performed.Data were analyzed by one-way analysis of variance (ANOVA), and multiple comparisons were performed using Tukey's test (α=0.05). Acidic and alkaline environments adversely affected the mechanical properties of zirconia, resulting in material degradation, loss of stabilizer content, and increase in tetragonal-monoclinic phase transformation. Commercial dental zirconia blocks have varied mechanical properties, but they are generally susceptible to degradation when exposed to corrosive environments.


  • Occlusal Surface Reconstruction with Chairside Ceramic Onlay Using CEREC Biogeneric Design Mode: Case Report

    by G. Akgungor, Y. Olcer, D. Şen, B. Tunçelli

    The occlusal design of dental restorations should stay in harmonic relation to the remaining dentition. In CAD/CAM dentistry, the occlusion is generated by the CAD software based on standard morphologies from the dental database. An automated adaptation process of this standard morphology to an individual clinical situation is difficult and leading to manual adaptation of the proposal with design tools. The new biogeneric software of the chairside CAD/CAD system (CEREC) automatically collects optic measurement of the preparation side including mesial and distal neighbor teeth and antagonist teeth to design a restoration with a patient specific occlusal morphology. This clinical report demonstrated a case, which was treated with ceramic onlay designed and milled with CEREC system used in biogeneric design mode. Digital impression of the preparation was taken with the intraoral camera. Buccal scan,technique was used for taking the occlusal record. Preparation and antagonist images were automatically correlated by software and a virtual articulator was created. After trimming the virtual model, preparation margins were outlined with the automatic margin finder option of the software and then the insertion axis of the restoration was determined. The biogeneric restoration proposal was then automatically seated to the virtual model and desired changes were performed with the design tools of the software. The restoration was milled from feldspathic ceramic block.

  • Influence of Zirconia Base and Shade Difference on Polymerization Efficiency of Dual-Cure Resin Cement

    by Volkan Turp, Deniz Sen, Erdal Poyrazoglu, Betul Tuncelli, Gultekin Goller

    Purpose: The aim of this study was to investigate the polymerization efficiency of dualcured resin cement beneath different shades of zirconia-based feldsphathic ceramic restorations. Materials and Methods: Five translucent zirconia (Zirkonzahn) discs (4.0-mm diameter, 1.2-mm height) were prepared. Feldsphathic ceramic (1.2 mm) (Noritake Cerabien Zr) in 5 shades (1M2, 2M2, 3M2, 4M2, 5M2) was applied on the zirconia discs. Twelve dual-cure resin cement specimens were prepared for each shade, using Panavia F 2.0 (Kuraray) in Teflon molds (4.0-mm diameter, 6.0-mm height), following the manufacturer's instructions. Light activation was performed through the zirconia-based ceramic discs for 20 seconds, using a quartz tungsten halogen curing device (Hilux 200) with irradiance of 600 mW/cm(2). Immediately following light curing, specimens were stored for 24 hours in dry, light-proof containers. Vickers hardness measurements were conducted using a microhardness tester with a 50-g load applied for 15 seconds. The indentations were made in the cross sectional area at four depths, and the mean values were recorded as Vickers hardness number (VHN). Results were statistically analyzed with one-way ANOVA and Tukey HSD test (p < 0.05). Results: A statistically significant decrease in VHN of the resin cement was noted with increasing depth and darkness of the shade (p < 0.05). Conclusion: Curing efficiency of dual-cure resin cement is mainly influenced by the lightness of the shades selected.


  • The retentive effects of pre‐fabricated posts by luting cements

    by D. Sen, E. Poyrazoglu, B. Tuncelli

    summary  The purpose of this study was to compare the retention of two different pre‐fabricated posts cemented to the root canal with four different adhesive luting cements and a zinc phosphate cement. The crowns of 100 freshly extracted human mandibular central and lateral incisors were removed at the cementoenamel junction and divided into two main groups (A = ParaPost and B = Flexi‐Post) and further divided into five subgroups to evaluate the effects of five different cements (Rely‐X ARC, Panavia F, ParaPost Cement, Flexi‐Flow Natural and Adhesor) each with 10 samples. Post‐holes were prepared on all of the roots following the manufacturer's instructions. Each sample was placed into a specialized jig and tensile strength tests performed by using testing machine with a crosshead speed of 0·638 cm min−1 and force applied until failure. The data were analysed with one‐way anova (Post Hoc a Scheffe's S test) and two‐way anova (P < 0·001). The Flexi‐Post dowels had a mean of 54·21 kg (s.d. = 9·37) and demonstrated statistically higher retention than ParaPost dowels with a mean of 33·93 kg (s.d. = 10·69) for all of the cement groups (P < 0·001). In Flexi‐Post and ParaPost dowel groups; Rely‐X ARC was statistically higher than the Panavia F, ParaPost Cement, Flexi‐Flow Natural and Adhesor (P < 0·05). Adhesor was significantly lower than the other subgroups (P < 0·05). Resin luting cements have demonstrated very high tensile strength potential for a strong bond to dentin.


  • Effects of Different Acid Treatments on Dental Ceramic Surfaces

    by D. Şen, G. Sınmazışık, E. Poyrazoğlu, B. Tunçelli, Burak Özkal, M. Lutfy Öveçoğlu

  • A Comparative Study of the Effect of Different Polishing Systems on Ceramic Dental Surfaces

    by G. Sınmazışık, D. Şen, B. Tunçelli, E. Poyrazoğlu, Burak Özkal, M. Lutfy Öveçoğlu

    • 1 June 1997
      • Vol. 5  (2) , 79-83

    Comparison of load transfer by implant abutments of various diameters.

    by B Tuncelli, E Poyrazoglu, A M Köylüoglu, S Tezcan

    The effects of diameter and position of implants on displacement and stress distribution, were investigated. ITI Hollow Cylinder two-stage implants with various diameters (3.5 mm, 4.5 mm and 6 mm) and positions are compared on the basis of a two dimensional finite element analysis. The mathematical results of this study demonstrate that, using conventional assumptions for stress levels in the crestal bone, relatively large diameter implants are preferable in the posterior mandibular area.