CVChristina Vanderwel

Christina Vanderwel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christina Vanderwel has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Passive scalar transport in a cross-ventilating flow with upstream source: wind and water tunnel measurements

    by Subhajit Biswas, Paul Hayden, Matteo Carpentieri, Christina Vanderwel

    In urban environments, pollutant ingress from outdoor sources poses a significant challenge to indoor air quality. Cross-ventilation, while essential for passive cooling and natural airflow, can also facilitate the entry of outdoor contaminants into indoor spaces. To investigate the dynamics of outdoor-to-indoor pollutant transport, the present study employs an idealized configuration, namely, a hollow cube representing a scaled-down model building with window openings in the upstream and downstream faces, subjected to an upstream passive scalar source within an atmospheric boundary layer. The experiments are conducted in two distinct facilities: a water tunnel using Rhodamine dye as the scalar, and a wind tunnel using propane gas, all performed at a specified flow Reynolds number of $$ \text{Re} = U_{{{\text{Ref}}}} H/\nu \approx 50,000 $$ Re = U Ref H / ν ≈ 50 , 000 for a fixed boundary layer-to-cube height ratio of about 3; here, $$ U_{{{\text{Ref}}}} $$ U Ref is the streamwise velocity at cube’s height ( H ) measured without the cube. The scalar, released from a ground-level upstream source, is predominantly transported by a streamwise advective flux, while relatively weaker wall-normal advective and turbulent fluxes contribute to vertical dispersion and local mixing. A fraction of the oncoming scalar enters the cube intermittently, through the upstream window. Inside, a central jet-like flow carries the scalar parcels primarily by streamwise advective flux, while also interacting with the upper and lower recirculation regions, enabling scalar exchange across these zones through wall-normal advective and turbulent fluxes. While the time-averaged concentration field inside the cube is nearly uniform, suggesting effective mixing, instantaneous concentration traces exhibit strong intermittency, with sporadic peak events, highlighting the risk of transient peak exposures. The indoor concentration exponentially decays over time once the source is turned off, with a slower decay in the upper recirculation region, implying relatively prolonged exposure near the ceiling region. Both experimental setups produce closely matching values and consistent trends in the spatio-temporal dynamics of scalar concentration, and also highlight their complementary nature, with each offering distinct advantages. The present findings will deepen our understanding of pollutant ingress and mixing in buildings in cross-ventilated flows and also offer valuable insights to future modeling of pollutant exposure in urban indoor spaces.


  • Open Access

    Passive scalar transport in a cross-ventilating flow with upstream source: Wind and Water tunnel measurements

    by Subhajit Biswas, Paul Hayden, Matteo Carpentieri, Christina Vanderwel

    In urban environments, pollutant ingress from outdoor sources poses a significant challenge to indoor air quality. Cross-ventilation, while essential for passive cooling and natural airflow, can also facilitate the entry of outdoor contaminants into indoor spaces. To investigate the dynamics of outdoor-to-indoor pollutant transport, the present study employs an idealised configuration, namely a hollow cube representing a scaled-down model building with window openings in the upstream and downstream faces, subjected to an upstream passive scalar source within an atmospheric boundary layer. The experiments are conducted in two distinct facilities: a water tunnel using Rhodamine dye as the scalar, and a wind tunnel using propane gas, all performed at a specified flow Reynolds number of Re = U Ref H/ν ≈ 50, 000 for a fixed boundary layer-to-cube height ratio of about 3; here, U Ref is the streamwise velocity at cube’s height (H) measured without the cube. The scalar, released from a ground-level upstream source, is predominantly transported by a streamwise advective flux, while relatively weaker wall-normal advective and turbulent fluxes contribute to vertical dispersion and local mixing. A fraction of the oncoming scalar enters the cube intermittently, through the upstream window. Inside, a central jet-like flow carries the scalar parcels primarily by streamwise advective flux, while also interacting with the upper and lower recirculation regions, enabling scalar exchange across these zones through wall-normal advective and turbulent fluxes. While the time-averaged concentration field inside the cube is nearly uniform, suggesting effective mixing, instantaneous concentration traces exhibit strong intermittency, with sporadic peak events, highlighting the risk of transient peak exposures. The indoor concentration exponentially decays over time once the source is turned off, with a slower decay in the upper recirculation region, implying relatively prolonged exposure near the ceiling region. Both experimental setups produce closely matching values and consistent trends in the spatio-temporal dynamics of scalar concentration, and also highlight their complementary nature, with each offering distinct advantages. The present findings will deepen our understanding of pollutant ingress and mixing in buildings in cross-ventilated flows and also offer valuable insights to future modelling of pollutant exposure in urban indoor spaces.

  • Open Access

    Flow through a hollow cube in a turbulent boundary layer: towards understanding indoor pollutant dispersion

    by Subhajit Biswas, Christina Vanderwel

    We experimentally investigate the flow through a hollow cube, with an indoor ground-level passive scalar source, immersed in a rough-wall turbulent boundary layer inside a water tunnel. The focus is on characterizing scalar transport within the cube, through simultaneous scalar and flow measurements using planar laser-induced fluorescence and particle image velocimetry. To understand the role of window positioning, three cube configurations, labelled as ‘centre’, ‘up-down’ and ‘down-up’, distinguished by window positions at the upstream and downstream ends, are studied. Varying window position alters the flow characteristics within the cube, resulting in differences in scalar concentration and distribution. The steady-state concentration is highest for ‘centre’, followed by ‘up-down’ and ‘down-up’ configurations. Regarding the scalar distribution, ‘centre’ showed accumulation near the top and bottom walls, while ‘up-down’ and ‘down-up’ exhibited scalar buildup in the lower and upper half of the cube, respectively. The flow patterns and scalar transport mechanisms remained consistent across different Reynolds numbers ( $Re=U_{Ref}H/\nu = 20\ 000$ , 35 000, 50 000) for each configuration; $U_{Ref}=$ incoming flow velocity at cube height ( $H$ ), and $\nu =\,$ kinematic viscosity of water. The analysis is extended by revising the classical box model, accounting for practical complexities such as non-perfect mixing. Our results can help better understand and model indoor–outdoor pollutant exchange in complex urban environments.


  • Open Access

    Comparing Large-Eddy Simulation and Gaussian Plume Model to Sensor Measurements of an Urban Smoke Plume

    by Dominic Clements, Matthew Coburn, Simon J. Cox, Florentin M. J. Bulot, Zheng-Tong Xie, Christina Vanderwel

    The fast prediction of the extent and impact of accidental air pollution releases is important to enable a quick and informed response, especially in cities. Despite this importance, only a small number of case studies are available studying the dispersion of air pollutants from fires in a short distance (O(1 km)) in urban areas. While monitoring pollution levels in Southampton, UK, using low-cost sensors, a fire broke out from an outbuilding containing roughly 3000 reels of highly flammable cine nitrate film and movie equipment, which resulted in high values of PM2.5 being measured by the sensors approximately 1500 m downstream of the fire site. This provided a unique opportunity to evaluate urban air pollution dispersion models using observed data for PM2.5 and the meteorological conditions. Two numerical approaches were used to simulate the plume from the transient fire: a high-fidelity computational fluid dynamics model with large-eddy simulation (LES) embedded in the open-source package OpenFOAM, and a lower-fidelity Gaussian plume model implemented in a commercial software package: the Atmospheric Dispersion Modeling System (ADMS). Both numerical models were able to quantitatively reproduce consistent spatial and temporal profiles of the PM2.5 concentration at approximately 1500 m downstream of the fire site. Considering the unavoidable large uncertainties, a comparison between the sensor measurements and the numerical predictions was carried out, leading to an approximate estimation of the emission rate, temperature, and the start and duration of the fire. The estimation of the fire start time was consistent with the local authority report. The LES data showed that the fire lasted for at least 80 min at an emission rate of 50 g/s of PM2.5. The emission was significantly greater than a ‘normal’ house fire reported in the literature, suggesting the crucial importance of the emission estimation and monitoring of PM2.5 concentration in such incidents. Finally, we discuss the advantages and limitations of the two numerical approaches, aiming to suggest the selection of fast-response numerical models at various compromised levels of accuracy, efficiency and cost.


  • Open Access

    Pollutant Dispersion Around a Single Tall Building

    by Tomos Rich, Christina Vanderwel

    An experiment was carried out using a scale model of a tall building, with the goal of investigating the role of individual buildings in the dispersion of air pollution. Pollutant dispersion around an isolated building with a height-to-length aspect ratio of 1.4 is investigated using simultaneous particle image velocimetry and planar laser induced fluorescence. Dye is released from a ground-level point source five building heights upstream of the tall building. It was found that in this case the scalar plume was dispersed laterally strongly by the building, but only slightly vertically. It is hypothesized that this is due to 94% of the plume impinging below the stagnation point on the front of the building and being drawn into the horseshoe vortex. We expect this fraction would be lower in a case in which the building is in an array of smaller buildings, and that this would lead to more vertical dispersion.