Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Koichi Chida has a total of 306 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and validation of a pregnant phantom with adjustable fetal presentation for region‐specific fetal radiation dose assessment during pelvic radiography

    by Yuta Matsunaga, Yumi Kataoka, Koichi Chida, Yasuki Asada

    Background: Accurate assessment of fetal radiation dose during diagnostic X‐ray examinations remains challenging because commercially available pregnancy phantoms do not adequately reproduce fetal anatomy or permit organ‐specific dose measurements. Purpose: The purpose of this study was to develop a pregnant phantom with adjustable fetal presentation and to evaluate its anatomical realism and applicability for fetal dose assessment during pelvic radiography. Methods: The developed phantom comprised an anthropomorphic phantom, a whole‐body fetal phantom, acrylic components, and water‐filled plastic bags. The fetal phantom was fabricated using three‐dimensional printing technology and incorporated bone‐equivalent and soft‐tissue‐equivalent materials. Fetal presentations could be adjusted to cephalic or breech presentations by repositioning the fetal phantom within the abdominal phantom. Computed tomography (CT) images were acquired to measure CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and surrounding water‐filled regions. Absorbed doses were measured using real‐time dosimeters placed at five locations in the fetal head and three locations in the fetal abdomen. Dose measurements were performed during pelvic radiography and compared with those obtained using a conventional homogeneous pregnancy phantom. Results: The mean CT numbers of the fetal brain, thorax, abdomen, pelvic bone, and water‐filled regions were 2.1, ‐0.8, ‐0.4, 323.8, and 1.6 HU, respectively. These values were within the expected ranges for soft tissue and bone and were comparable to those of a conventional homogeneous phantom. During pelvic radiography, the mean absorbed doses measured using the adjustable fetal‐presentation phantom were 1.34 mGy in the fetal head and 0.07 mGy in the fetal abdomen for the cephalic presentation, and 0.05 mGy and 1.67 mGy, respectively, for the breech presentation. In comparison, the mean absorbed dose measured in the fetal region of the conventional homogeneous phantom was 2.05 mGy. The findings demonstrated substantial differences in regional fetal dose distribution according to fetal presentation. In particular, the fetal head dose in the cephalic presentation was lower than that measured using the conventional phantom. This difference may be partly attributable to attenuation by the fetal skull; however, the comparison should be interpreted with caution given differences in phantom geometry, internal materials, and dosimeter locations between the two phantoms. Conclusion: A novel pregnant phantom with adjustable fetal presentation was successfully developed. The phantom reproduced anatomically relevant structures using realistic bone‐equivalent and soft‐tissue‐equivalent materials and enabled direct dose measurements in specific fetal anatomical regions. Compared with a conventional homogeneous phantom, the developed phantom provided a more detailed assessment of fetal dose distributions and allowed evaluation of the effects of fetal presentation on radiation exposure during pelvic radiography.

  • Measured fetal-region dose in X-ray pelvimetry and low-dose computed tomography using a realistic pregnant phantom: a comparative study

    by Yuta Matsunaga, Masanao Kobayashi, Koichi Chida, Yasuki Asada

    This study evaluated fetal-region doses and dose distributions for X-ray pelvimetry (Guthmann and Martius methods) using exposure conditions from a nationwide survey in Japan and compared them with those of a low-dose computed tomography (CT) protocol using a realistic late-pregnancy phantom. A pregnancy model phantom combining an anthropomorphic phantom with a custom-made abdominal phantom was used. Real-time dosimeters were placed at 18 sites across three abdominal levels. The low-dose CT protocol showed a nearly uniform fetal-region dose distribution, whereas the X-ray methods showed heterogeneous distributions depending on beam direction and irradiation field. The reported mean fetal-region doses were 1.16 mGy for Guthmann, 4.05 mGy for Martius, 5.21 mGy for the combined X-ray examinations, and 0.69 mGy for low-dose CT. These results indicate that the low-dose CT protocol evaluated in this study produced a lower fetal-region dose than the Guthmann and Martius methods evaluated in this study.

  • Open Access

    Transition from a detector-dose-based to a CNR-based cerebral angiography system: evaluation of image quality and radiation dose

    by Kota Hachiya, Hiroki Abiko, Koichi Chida, Yoshikazu Matsuda

    To evaluate the image quality and clinical radiation dose of a cerebral angiography system featuring contrast-to-noise ratio (CNR)-based exposure control for neurovascular endovascular treatment (EVT). Image quality was evaluated using a quality control phantom under fluoroscopy and digital subtraction angiography (DSA). Clinical radiation dose was retrospectively compared between a conventional angiography system using detector dose-based exposure control (61 cerebral aneurysm EVT procedures) and a new angiography system using CNR-based exposure control (99 procedures). Patient entrance reference air kerma (K a,r ) and air kerma–area product (P KA ) were analyzed. The new system demonstrated significantly higher observer scores than the conventional system for both fluoroscopy and DSA, including spatial resolution, low-contrast resolution, and dynamic range. The median total K a,r was 1818 [1301–2744] mGy with the new system and 2283 [1580–3184] mGy with the conventional system, representing a 20% reduction (p < 0.05). Conversely, the median total P KA increased by 26% (173 [120–237] vs. 137 [93–207] Gy·cm 2 , p < 0.05), but remained below the current Japanese diagnostic reference level for cerebral aneurysm EVT. Compared with the conventional system, the new angiography platform demonstrated superior image quality under phantom conditions and was associated with a 20% reduction in total K a,r during cerebral aneurysm EVT. Although the total P KA increased by 26%, this increase may have reflected differences in the magnification strategy between the two systems, suggesting a need for further optimization.

  • Open Access

    Lightweight X-ray shielding drape with a detachable shielding wall for enhanced occupational radiation protection in interventional radiology

    by Kodai Sagehashi, Eishin Sasaki, Minori Ishida, Hina Imai, Kazuma Kanke, Tomoya Sato, Mami Nemoto, Kanae Konta, Toshiki Kato, Masahiro Sota, et al.

  • Cellular effects induced by insoluble radioactive cesium-bearing microparticles derived from the Fukushima Daiichi nuclear power plant accident

    by Masatoshi Suzuki, Satoru Endo, Kazuhiko Ninomiya, Kentaro Manabe, Yutaka Yamada, Yohei Inaba, Koichi Chida, Manabu Fukumoto

    Radioactive materials are released into the environment and then transferred to animals and humans whenever atmospheric nuclear tests or nuclear disasters occur (Suzuki et al. 2019). Radioactive pa...

  • Open Access

    Real-time evaluation of operator eye lens radiation dose in interventional radiology: Effects of protective shield position and X-ray beam angle

    by Kodai Sagehashi, Masaki Fujisawa, Yoshihiro Haga, Toshiki Kato, Saki Takahira, Masahiro Sota, Yuji Kaga, Takeshi Arai, Norio Tada, Koichi Chida


  • Open Access

    Fundamental evaluation of a novel upright shield to protect medical personnel from scattered radiation during endoscopic retrograde cholangiopancreatography using a C-arm system

    by Hiroki Ishii, Koichi Chida, Yohei Inaba, Shu Onodera, Shingo Kayano, Masahiro Sai

    Medical personnel performing endoscopic retrograde cholangiopancreatography (ERCP) are at a high risk of developing radiation-induced injuries, such as cataracts, due to scattered radiation, making the use of appropriate radiation protection equipment essential. We developed two types of upright shields attached to a C-arm system (under-couch tube position): one for the operator and the other for the anesthesiologist. The purpose of this study was to evaluate the protective effect of these upright shields. We conducted a phantom study in typical ERCP settings and compared the scattered radiation doses between the C-arm system equipped with the upright shields and an over-couch tube system equipped with an ERCP-specific lead curtain. It was found that the upright shield for the operator reduced scattered radiation exposure by 90%, and the upright shield for the anesthesiologist reduced scattered radiation exposure by 86%. The upright shields for a C-arm system could be just as effective as the ERCP-specific curtain for an over-couch tube system. The use of the novel upright shields may eliminate the need for protective glasses and is expected to not only protect the eyes but also safeguard the thyroid and brain.

  • Factors associated with increased patient radiation dose during cerebral aneurysm embolization

    by Satoru Kawauchi, Koichi Chida, Takashi Moritake, Yusuke Hamada, Wataro Tsuruta

    With expanding indications for interventional neuroradiology, patient radiation exposure remains a significant concern. This study aimed to identify predictors of high peak skin dose and left lens doses using directly measured patient radiation data. We retrospectively analyzed patient doses and performed multivariate logistic regression. Treatment of a posterior circulation aneurysm [odds ratio (OR) = 7.491; 95% confidence interval (CI), 1.217–46.110] and stent use (OR = 5.516; 95% CI, 1.318–23.085) were identified as independent predictors of peak skin dose exceeding 1.0 Gy. Stent use was also a significant predictor of left lens dose exceeding 100 mGy (OR = 3.141; 95% CI, 1.488–7.851). These findings provide a robust, evidence-based framework for identifying high-risk patients preprocedurally. This knowledge is crucial for enhancing the informed consent process and justifying the timely implementation of dose-reduction strategies to minimize the risk of radiation-induced injuries.

  • Open Access

    Evaluation of γ-ray effects on a β-ray survey meter with a plastic scintillation sensor

    by Keisuke Yamamoto, Ryota Shindo, Yohei Inaba, Masatoshi Suzuki, Hiroo Chiba, Masayuki Zuguchi, Koichi Chida

  • Open Access

    Patient Radiation Dose During Fluoroscopy-Guided Peripherally Inserted Central Catheter (PICC) Placement

    by Masakatsu Tano, Kodai Sagehashi, Koichi Chida

    This retrospective study evaluated patient radiation dose during fluoroscopy-guided peripherally inserted central catheter (PICC) placement. A total of 1240 consecutive adult patients who underwent PICC placement between January 2023 and December 2024 were analyzed. Patient radiation dose indices, including air kerma (AK) and dose–area product (DAP), as well as fluoroscopy time and number of radiographic acquisitions, were obtained from the radiology information system. The mean and median AK were 2.47 mGy and 1.54 mGy, respectively, and the median DAP was 901.9 mGy·cm2. The median fluoroscopy time was 1.9 min, and the median number of radiographic acquisitions was 1. Patient radiation dose during PICC placement was lower than the Japanese Diagnostic Reference Levels (Japan DRLs 2025). AK showed a strong positive correlation with fluoroscopy time (Spearman’s rank correlation, ρ = 0.77), whereas correlations between AK and BMI or the number of radiographic acquisitions were weak. In some patients with high BMI, AK values exceeding 40 mGy were observed. These findings indicate that patient radiation dose during PICC placement is generally low but remains closely associated with fluoroscopy time. Optimization of the patient radiation dose should be considered, particularly for patients with high BMIs or those undergoing repeated PICC placements.