Tommaso Toppi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tommaso Toppi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Marcello Aprile
11 shared publications- Mario Motta
Department of Energy, Politecnico di Milano, 20156 Milan, Italy
9 shared publications Mario Motta
8 shared publicationsMarco Guerra
7 shared publications- Marcello Aprile
Politecnico di Milano
6 shared publications - Giorgio Villa
Politecnico di Milano
5 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 305
Optimization of a fin-and-tube latent thermal energy storage for domestic hot water application
- 31 August 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 305
Open AccessOptimization of a fin-and-tube latent thermal energy storage for domestic hot water application
- Open Access
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental investigation of propane/pentane (R290/R601) mixtures in a residential high-temperature heat pump: effects of mixture composition and internal heat exchanger
Decarbonizing the building sector requires heat pumps to be increasingly retrofitted into existing residential buildings, where conventional hydronic systems often demand high supply temperatures. Propane is among the most promising low global warming refrigerants for this purpose, but its operation can be limited by high compressor discharge temperatures under severe conditions. This work experimentally investigates whether blending propane with pentane can mitigate this limitation and how a bypassable internal heat exchanger affects system performance. For this purpose, a heat pump prototype was built and tested with pure propane and 90/10 and 80/20 wt.% propane/pentane mixtures under space heating and domestic hot water conditions, with and without the internal heat exchanger. The results show that no single configuration was optimal over the whole operating envelope. The internal heat exchanger improved the performance when sufficient margin was available on the compressor discharge temperature. At the same time, pentane addition lowered compressor discharge temperature and became more favorable for larger heat-sink temperature variations, although it penalized the heating capacity. As a result, in space heating operation, pure propane remained preferable at lower sink temperature levels or when heating capacity was the dominant constraint, whereas the mixtures became beneficial mainly at higher temperature lifts when combined with the internal heat exchanger. In domestic hot water operation, where the sink-side temperature variation was larger, the mixtures combined with the internal heat exchanger showed the clearest benefits.
- 28 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental investigation of propane/pentane (R290/R601) mixtures in a residential high-temperature heat pump: effects of mixture composition and internal heat exchanger
Decarbonizing the building sector requires heat pumps to be increasingly retrofitted into existing residential buildings, where conventional hydronic systems often demand high supply temperatures. Propane is among the most promising low global warming refrigerants for this purpose, but its operation can be limited by high compressor discharge temperatures under severe conditions. This work experimentally investigates whether blending propane with pentane can mitigate this limitation and how a bypassable internal heat exchanger affects system performance. For this purpose, a heat pump prototype was built and tested with pure propane and 90/10 and 80/20 wt.% propane/pentane mixtures under space heating and domestic hot water conditions, with and without the internal heat exchanger. The results show that no single configuration was optimal over the whole operating envelope. The internal heat exchanger improved the performance when sufficient margin was available on the compressor discharge temperature. At the same time, pentane addition lowered compressor discharge temperature and became more favorable for larger heat-sink temperature variations, although it penalized the heating capacity. As a result, in space heating operation, pure propane remained preferable at lower sink temperature levels or when heating capacity was the dominant constraint, whereas the mixtures became beneficial mainly at higher temperature lifts when combined with the internal heat exchanger. In domestic hot water operation, where the sink-side temperature variation was larger, the mixtures combined with the internal heat exchanger showed the clearest benefits.
- Open Access
- 18 May 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental investigation on discharge control variables for a silica gel-water adsorption system for cooling energy storage
Heat and cold storage technologies are essential for increasing the use of intermittent renewable energy sources. Among them, thermochemical storage can offer higher energy density than sensible storage. This work experimentally investigates a single-bed silica gel/water adsorption system with a falling-film evaporator used as a cold storage unit, with specific attention to how the discharging phase can be controlled. Tests were carried out under different operating conditions by varying the chilled-water temperature and the temperature of the water cooling the adsorber to quantify the cooling energy released during adsorption. In addition, different parameters were evaluated to assess their potential in controlling the cooling-power profile during discharge: the opening of the valve between the evaporator and the adsorber, the cooling-water flow rate through the adsorber and the activation of the falling-film circulation pump. The measured cooling energy density ranged from 31 to 162 kWh/m3 for cooling-water temperatures between 25 and 40 °C and chilled-water temperatures between 10 and 20 °C. Among the tested control options, modulation of the valve between the evaporator and the adsorption bed proved to be the most effective strategy, as it reduces the initial power peak, smooths the release of stored energy and extends the discharge duration.
- 18 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental investigation on discharge control variables for a silica gel-water adsorption system for cooling energy storage
Heat and cold storage technologies are essential for increasing the use of intermittent renewable energy sources. Among them, thermochemical storage can offer higher energy density than sensible storage. This work experimentally investigates a single-bed silica gel/water adsorption system with a falling-film evaporator used as a cold storage unit, with specific attention to how the discharging phase can be controlled. Tests were carried out under different operating conditions by varying the chilled-water temperature and the temperature of the water cooling the adsorber to quantify the cooling energy released during adsorption. In addition, different parameters were evaluated to assess their potential in controlling the cooling-power profile during discharge: the opening of the valve between the evaporator and the adsorber, the cooling-water flow rate through the adsorber and the activation of the falling-film circulation pump. The measured cooling energy density ranged from 31 to 162 kWh/m3 for cooling-water temperatures between 25 and 40 °C and chilled-water temperatures between 10 and 20 °C. Among the tested control options, modulation of the valve between the evaporator and the adsorption bed proved to be the most effective strategy, as it reduces the initial power peak, smooths the release of stored energy and extends the discharge duration.
- 1 April 2026
- Published by Springer Nature
- p. 730-740
Multi-Objective Optimization of a Latent Thermal Energy Storage with Enhanced Thermal Conductivity for Heat Pump Applications
- 1 April 2026
- Published by Springer Nature
- p. 730-740
Multi-Objective Optimization of a Latent Thermal Energy Storage with Enhanced Thermal Conductivity for Heat Pump Applications
- Open Access
- 25 March 2026
- Published by Elsevier in International Journal of Refrigeration
- Vol. 187
Dynamic modeling of an innovative gas-driven absorption heat pump for residential applications: Transient Start-Up analysis
- 25 March 2026
- Published by Elsevier in International Journal of Refrigeration
- Vol. 187
Open AccessDynamic modeling of an innovative gas-driven absorption heat pump for residential applications: Transient Start-Up analysis
- Open Access
Absorption Heat Transformer and Vapor Compression Heat Pump as Alternative Options for Waste Heat Upgrade in the Industry
Increasing the temperature of waste heat is crucial to enable its recovery. Vapor compression heat pumps and absorption heat transformers are the two heat upgrade technologies most commonly used for this purpose. Heat pumps have the advantage of entirely recovering the waste heat and the disadvantage of requiring electricity as input. Heat transformers need a negligible amount of electricity but reject at part of the waste heat input at low temperature. Due to these differences, the choice between the two options depends on the application. In this work, the environmental and economic performance of heat pumps and heat transformers are compared in some relevant applications. Indications about the most suitable technology are provided based on the availability of the waste heat, of the CO2 content of the electricity and of the electricity–gas price ratio. Heat pumps perform better when the waste heat availability is limited compared to the upgraded heat requirements and has a better environmental profile when the electricity has low carbon content. Heat transformer results are often economically convenient, especially when the availability of waste heat is large.
Open AccessAbsorption Heat Transformer and Vapor Compression Heat Pump as Alternative Options for Waste Heat Upgrade in the Industry
Increasing the temperature of waste heat is crucial to enable its recovery. Vapor compression heat pumps and absorption heat transformers are the two heat upgrade technologies most commonly used for this purpose. Heat pumps have the advantage of entirely recovering the waste heat and the disadvantage of requiring electricity as input. Heat transformers need a negligible amount of electricity but reject at part of the waste heat input at low temperature. Due to these differences, the choice between the two options depends on the application. In this work, the environmental and economic performance of heat pumps and heat transformers are compared in some relevant applications. Indications about the most suitable technology are provided based on the availability of the waste heat, of the CO2 content of the electricity and of the electricity–gas price ratio. Heat pumps perform better when the waste heat availability is limited compared to the upgraded heat requirements and has a better environmental profile when the electricity has low carbon content. Heat transformer results are often economically convenient, especially when the availability of waste heat is large.
- Open Access
- 31 March 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 175, 118-127
Compressor-assisted heat transformer for low-grade heat recovery
- 31 March 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 175, 118-127
Open AccessCompressor-assisted heat transformer for low-grade heat recovery
- 11 December 2022
- Published by Elsevier in International Journal of Refrigeration
- Vol. 146, 471-482
Modelling of a falling-film evaporator for adsorption chillers
- 11 December 2022
- Published by Elsevier in International Journal of Refrigeration
- Vol. 146, 471-482
Modelling of a falling-film evaporator for adsorption chillers
- 23 September 2022
- Published by Elsevier in International Journal of Refrigeration
- Vol. 145, 290-300
Performance improvement of gas-driven absorption heat pumps by controlling the flow rate in the solution branch
- 23 September 2022
- Published by Elsevier in International Journal of Refrigeration
- Vol. 145, 290-300
Performance improvement of gas-driven absorption heat pumps by controlling the flow rate in the solution branch
- Open Access
Testing of a Falling-Film Evaporator for Adsorption Chillers
In this work, the performance of an innovative evaporator based on water falling film was investigated. The studied evaporator has been equipped with a recirculation system to maximise the wetted surface. Tests have been carried out in a lab-scale adsorption unit connected to a test bench recently realised at Politecnico di Milano labs for evaluating heat transfer performances under realistic operating conditions. Several ad/desorption cooling cycles were performed, setting different liquid refrigerant initial contents (0.9–1.5 kg), different chilled water inlet temperatures (7–20 °C) and flow rates (200–1000 L/h) and different adsorbent bed temperatures (25–30 °C). Evaporation performance has been determined in delivered cooling capacity. Moreover, the experimental data were used to calculate the overall evaporator heat transfer conductance (UA). Experiments showed how the heat duty peaks are mainly due to the thermal level of the chilled water that enters the evaporator, not the water content inside it because this value only affects the duration of the process. Instead, the UA value does not depend on the evaporator inlet chilled water temperature and initial mass content inside the evaporator. UA is 540–570 W/K for temperatures of chilled water entering the evaporator, equal to 10–20 °C, and mass of refrigerant of 0.9–1.5 kg.
Open AccessTesting of a Falling-Film Evaporator for Adsorption Chillers
In this work, the performance of an innovative evaporator based on water falling film was investigated. The studied evaporator has been equipped with a recirculation system to maximise the wetted surface. Tests have been carried out in a lab-scale adsorption unit connected to a test bench recently realised at Politecnico di Milano labs for evaluating heat transfer performances under realistic operating conditions. Several ad/desorption cooling cycles were performed, setting different liquid refrigerant initial contents (0.9–1.5 kg), different chilled water inlet temperatures (7–20 °C) and flow rates (200–1000 L/h) and different adsorbent bed temperatures (25–30 °C). Evaporation performance has been determined in delivered cooling capacity. Moreover, the experimental data were used to calculate the overall evaporator heat transfer conductance (UA). Experiments showed how the heat duty peaks are mainly due to the thermal level of the chilled water that enters the evaporator, not the water content inside it because this value only affects the duration of the process. Instead, the UA value does not depend on the evaporator inlet chilled water temperature and initial mass content inside the evaporator. UA is 540–570 W/K for temperatures of chilled water entering the evaporator, equal to 10–20 °C, and mass of refrigerant of 0.9–1.5 kg.