Cornelis Slagt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cornelis Slagt has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
Geert-Jan van Geffen
Radboudumc afd. Anesthesiologie, Pijnbestrijding en Palliatieve Geneeskunde, Nijmegen
4 shared publicationsSjoerd Servaas
Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
4 shared publications- Geert-Jan van Geffen
Department of Anesthesiology, Radboud University Medical Centre, Nijmegen, The Netherlands
3 shared publications Ignacio Malagon
From the Department of Anaesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands (SS, LTvE, IM, CS)
3 shared publications- Ignacio Malagon
Department of Anaesthesia Radboud UMC Nijmegen the Netherlands
3 shared publications Lucas Theodorus van Eijk
Department of Anesthesiology, Pain and Palliative Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 1 May 2025
- Published by Taylor & Francis in Open Access Emergency Medicine
- Vol. ume 17, 203-213
First Results of Our Local Practice Guide Used During the Late Phase of Resuscitation in Patients with Refractory VF in Out of Hospital Cardiac Arrest
Objective: Treatment of refractory ventricular fibrillation (rVF) is a clinical challenge. If rVF is still present after standard advanced life support (ALS) guideline care, including amiodaron administration, other therapeutic options might be necessary. Based on the available evidence and expertise, our Helicopter Emergency Medical Service (HEMS) team developed a local practice guide for the prolonged resuscitation of patients in rVF and implemented this as standard HEMS care in March 2022. Methods: This database study contains all patients treated with our local practice guide during out of hospital cardiac arrest (OHCA) with rVF beyond the fifth regular ALS shock-block. This local practice HEMS treatment algorithm consisted of, among others, cessation of epinephrine and alternating administration of esmolol and norepinephrine combined with enoximone. Data were derived from the HEMS database and the treating hospitals. Primary outcome was the return of spontaneous circulation. Secondary outcome was defined as survival to hospital discharge and cerebral performance. This outcome was compared to the literature to analyze for inferiority of treatment. Results: In a 21-month period, HEMS was 761 times deployed for OHCA. Nineteen patients were treated with the local practice guide, nine patients (47%) were admitted to hospital with return of spontaneous circulation. Median resuscitation time was 22min. Hospital survival with good neurology was achieved in 42% vs 17% as expected. Exact Clopper-Pearson and logistic regression analysis revealed non-inferiority of the local practice guide. Withholding epinephrine was achieved in 84% of patients. A total of 79% and 90% of patients received esmolol and norepinephrine/enoximone mixture, respectively. Alternative defibrillation positions were indicated in 18 patients but applied in only 6 (33%). Conclusion: In patients with persisting VF despite prolonged advanced life support care, a multifaceted bundle of care approach shows promising results and warrants further research. Alternative drug administrations were found to be substantially easier to achieve compared to alternative defibrillation positions.
- 1 May 2025
- Published by Taylor & Francis in Open Access Emergency Medicine
- Vol. ume 17, 203-213
Open AccessFirst Results of Our Local Practice Guide Used During the Late Phase of Resuscitation in Patients with Refractory VF in Out of Hospital Cardiac Arrest
Objective: Treatment of refractory ventricular fibrillation (rVF) is a clinical challenge. If rVF is still present after standard advanced life support (ALS) guideline care, including amiodaron administration, other therapeutic options might be necessary. Based on the available evidence and expertise, our Helicopter Emergency Medical Service (HEMS) team developed a local practice guide for the prolonged resuscitation of patients in rVF and implemented this as standard HEMS care in March 2022. Methods: This database study contains all patients treated with our local practice guide during out of hospital cardiac arrest (OHCA) with rVF beyond the fifth regular ALS shock-block. This local practice HEMS treatment algorithm consisted of, among others, cessation of epinephrine and alternating administration of esmolol and norepinephrine combined with enoximone. Data were derived from the HEMS database and the treating hospitals. Primary outcome was the return of spontaneous circulation. Secondary outcome was defined as survival to hospital discharge and cerebral performance. This outcome was compared to the literature to analyze for inferiority of treatment. Results: In a 21-month period, HEMS was 761 times deployed for OHCA. Nineteen patients were treated with the local practice guide, nine patients (47%) were admitted to hospital with return of spontaneous circulation. Median resuscitation time was 22min. Hospital survival with good neurology was achieved in 42% vs 17% as expected. Exact Clopper-Pearson and logistic regression analysis revealed non-inferiority of the local practice guide. Withholding epinephrine was achieved in 84% of patients. A total of 79% and 90% of patients received esmolol and norepinephrine/enoximone mixture, respectively. Alternative defibrillation positions were indicated in 18 patients but applied in only 6 (33%). Conclusion: In patients with persisting VF despite prolonged advanced life support care, a multifaceted bundle of care approach shows promising results and warrants further research. Alternative drug administrations were found to be substantially easier to achieve compared to alternative defibrillation positions.
- 2 December 2024
- Vol. 168
[Thoracocentesis: wright indication and wright placement?].
The incidence of a tension pneumothorax is very low. The initial treatment of a tension pneumothorax is needle thoracocentesis. This procedure is not a routine treatment and this invasive treatment is not without risks. Recognition of a clinically relevant tension pneumothorax remains difficult especially in the prehospital setting. Elevation of one half of the chest is a notoriously unreliable observation in relation to the diagnosis of tension pneumothorax. Absence of breath sounds without tension physiology is not a reason to perform a thoracocentesis. With the help of 3 cases we would like to explain and clarify the clinical presentation, the indication for and the correct procedure of thoracentesis.
- 2 December 2024
- Vol. 168
[Thoracocentesis: wright indication and wright placement?].
The incidence of a tension pneumothorax is very low. The initial treatment of a tension pneumothorax is needle thoracocentesis. This procedure is not a routine treatment and this invasive treatment is not without risks. Recognition of a clinically relevant tension pneumothorax remains difficult especially in the prehospital setting. Elevation of one half of the chest is a notoriously unreliable observation in relation to the diagnosis of tension pneumothorax. Absence of breath sounds without tension physiology is not a reason to perform a thoracocentesis. With the help of 3 cases we would like to explain and clarify the clinical presentation, the indication for and the correct procedure of thoracentesis.
- Open Access
- 19 September 2023
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 31 (1) , 1-6
Feasibility of HEMS performed prehospital extracorporeal-cardiopulmonary resuscitation in paediatric cardiac arrests; two case reports
Introduction: A broad range of pathophysiologic conditions can lead to cardiopulmonary arrest in children. Some of these children suffer from refractory cardiac arrest, not responding to basic and advanced life support. Extracorporeal-Cardiopulmonary Resuscitation (E-CPR) might be a life-saving option for this group. Currently this therapy is only performed in-hospital, often necessitating long transport times, thereby negatively impacting eligibility and chances of survival. We present the first two cases of prehospital E-CPR in children performed by regular Helicopter Emergency Medical Services (HEMS). Case presentations: The first patient was a previously healthy 7 year old boy who was feeling unwell for a couple of days due to influenza. His course deteriorated into a witnessed collapse. Direct bystander CPR and subsequent ambulance advanced life support was unsuccessful in establishing a perfusing rhythm. While doing chest compressions, the patient was seen moving both his arms and making spontaneous breathing efforts. Echocardiography however revealed a severe left ventricular impairment (near standstill). The second patient was a 15 year old girl, known with bronchial asthma and poor medication compliance. She suffered yet another asthmatic attack, so severe that she progressed into cardiac arrest in front of the attending ambulance and HEMS crews. Despite maximum bronchodilator therapy, intubation and the exclusion of tension pneumothoraxes and dynamic hyperinflation, no cardiac output was achieved. Intervention: After consultation with the nearest paediatric E-CPR facilities, both patients were on-scene cannulated by regular HEMS. The femoral artery and vein were cannulated (15-17Fr and 21Fr respectively) under direct ultrasound guidance using an out-of-plane Seldinger approach. Extracorporeal Life Support flow of 2.1 and 3.8 l/min was established in 20 and 16 min respectively (including preparation and cannulation). Both patients were transported uneventfully to the nearest paediatric intensive care with spontaneous breathing efforts and reactive pupils during transport. Conclusion: This case-series shows that a properly trained regular HEMS crew of only two health care professionals (doctor and flight nurse) can establish E-CPR on-scene in (older) children. Ambulance transport with ongoing CPR is challenging, even more so in children since transportation times tend to be longer compared to adults and automatic chest compression devices are often unsuitable and/or unapproved for children. Prehospital cannulation of susceptible E-CPR candidates has the potential to reduce low-flow time and offer E-CPR therapy to a wider group of children suffering refractory cardiac arrest.
- 19 September 2023
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 31 (1) , 1-6
Open AccessFeasibility of HEMS performed prehospital extracorporeal-cardiopulmonary resuscitation in paediatric cardiac arrests; two case reports
Introduction: A broad range of pathophysiologic conditions can lead to cardiopulmonary arrest in children. Some of these children suffer from refractory cardiac arrest, not responding to basic and advanced life support. Extracorporeal-Cardiopulmonary Resuscitation (E-CPR) might be a life-saving option for this group. Currently this therapy is only performed in-hospital, often necessitating long transport times, thereby negatively impacting eligibility and chances of survival. We present the first two cases of prehospital E-CPR in children performed by regular Helicopter Emergency Medical Services (HEMS). Case presentations: The first patient was a previously healthy 7 year old boy who was feeling unwell for a couple of days due to influenza. His course deteriorated into a witnessed collapse. Direct bystander CPR and subsequent ambulance advanced life support was unsuccessful in establishing a perfusing rhythm. While doing chest compressions, the patient was seen moving both his arms and making spontaneous breathing efforts. Echocardiography however revealed a severe left ventricular impairment (near standstill). The second patient was a 15 year old girl, known with bronchial asthma and poor medication compliance. She suffered yet another asthmatic attack, so severe that she progressed into cardiac arrest in front of the attending ambulance and HEMS crews. Despite maximum bronchodilator therapy, intubation and the exclusion of tension pneumothoraxes and dynamic hyperinflation, no cardiac output was achieved. Intervention: After consultation with the nearest paediatric E-CPR facilities, both patients were on-scene cannulated by regular HEMS. The femoral artery and vein were cannulated (15-17Fr and 21Fr respectively) under direct ultrasound guidance using an out-of-plane Seldinger approach. Extracorporeal Life Support flow of 2.1 and 3.8 l/min was established in 20 and 16 min respectively (including preparation and cannulation). Both patients were transported uneventfully to the nearest paediatric intensive care with spontaneous breathing efforts and reactive pupils during transport. Conclusion: This case-series shows that a properly trained regular HEMS crew of only two health care professionals (doctor and flight nurse) can establish E-CPR on-scene in (older) children. Ambulance transport with ongoing CPR is challenging, even more so in children since transportation times tend to be longer compared to adults and automatic chest compression devices are often unsuitable and/or unapproved for children. Prehospital cannulation of susceptible E-CPR candidates has the potential to reduce low-flow time and offer E-CPR therapy to a wider group of children suffering refractory cardiac arrest.
- Open Access
- 4 April 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (10) , 1867-1874
Validation of non-invasive point of care blood content analysis using the TensorTip™ MTX device: a method comparison study
Objectives: The TensorTip™ MTX is a non-invasive device designed to determine several physiological parameters with additional analysis of haemoglobin, haematocrit and blood gas analysis by interpreting blood diffusion colour of the finger skin based on spectral analysis. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in a clinical setting in comparison with routine analysis of blood samples. Methods: Forty-six patients, scheduled for elective surgery, were enrolled in this study. Placement of an arterial catheter had to be part of the standard of care. Measurements were performed during the perioperative period. The measurements obtained with the TensorTip MTX were compared with the results of routine analysis of the blood samples as a reference using correlation, Bland-Altman analysis and mountain plots. Results: No significant correlation was present in the measurements. Measurement of haemoglobin with the TensorTip MTX had a mean bias of 0.4 mmol/L, haematocrit’s bias was 3.0 %. Bias of partial pressure of carbon dioxide and oxygen was 3.6 and 66.6 mmHg, respectively. Calculated percentage errors were 48.2 , 48.9, 39.9 and 109.0 %. Proportional bias was present in all Bland-Altman analyses. Less than 95 % of the differences fell within the pre-set limits of allowable error. Conclusions: Non-invasive blood content analysis with the TensorTip MTX device is not equivalent to and did not correlate sufficiently with conventional laboratory analysis. None of the parameters measured showed results within the limits of allowable error. Therefore, the use of the TensorTip MTX is not recommended for perioperative care.
- 4 April 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (10) , 1867-1874
Open AccessValidation of non-invasive point of care blood content analysis using the TensorTip™ MTX device: a method comparison study
Objectives: The TensorTip™ MTX is a non-invasive device designed to determine several physiological parameters with additional analysis of haemoglobin, haematocrit and blood gas analysis by interpreting blood diffusion colour of the finger skin based on spectral analysis. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in a clinical setting in comparison with routine analysis of blood samples. Methods: Forty-six patients, scheduled for elective surgery, were enrolled in this study. Placement of an arterial catheter had to be part of the standard of care. Measurements were performed during the perioperative period. The measurements obtained with the TensorTip MTX were compared with the results of routine analysis of the blood samples as a reference using correlation, Bland-Altman analysis and mountain plots. Results: No significant correlation was present in the measurements. Measurement of haemoglobin with the TensorTip MTX had a mean bias of 0.4 mmol/L, haematocrit’s bias was 3.0 %. Bias of partial pressure of carbon dioxide and oxygen was 3.6 and 66.6 mmHg, respectively. Calculated percentage errors were 48.2 , 48.9, 39.9 and 109.0 %. Proportional bias was present in all Bland-Altman analyses. Less than 95 % of the differences fell within the pre-set limits of allowable error. Conclusions: Non-invasive blood content analysis with the TensorTip MTX device is not equivalent to and did not correlate sufficiently with conventional laboratory analysis. None of the parameters measured showed results within the limits of allowable error. Therefore, the use of the TensorTip MTX is not recommended for perioperative care.
- Open Access
- 1 December 2022
- Published by Elmer Press, Inc. in Cardiology Research
- Vol. 13 (6) , 372-379
Perioperative Validation of the TensorTip™ MTX Device for Noninvasive Arterial Pressure Measurement: A Method Comparison Study
Background: The noninvasive TensorTip™ MTX measures blood pressure by interpreting blood diffusion color of the finger skin. In addition to blood pressure, the device is able to measure various vital signs: heart rate, oxygen saturation, stroke volume, and cardiac output. Studies about accuracy and precision thus far available have only been conducted by the manufacturer. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in comparison to invasive radial artery blood pressure values. Methods: Forty-one patients scheduled for elective surgery were enrolled in this study. Placement of the arterial catheter had to be part of the standard of care. Once hemodynamic stable conditions were achieved, blood pressure was measured. Three measurements with the TensorTip MTX were averaged and compared with one invasive blood pressure measurement using Bland-Altman plot and error grid analysis. Results: Systolic, diastolic, and mean blood pressure had a bias of respectively 6.2, -6.9 and 4.4 mm Hg. Corresponding standard deviation were respectively 30.1, 17.0 and 22.2. Calculated percentage errors were 47.6%, 52.9% and 52.3%. Proportional bias was present in all Bland-Altman analyses. Error grid analysis showed 61.0% of systolic blood pressure measurements, and 46.3% of mean blood pressure measurements were in the clinical acceptable zone. Conclusions: The TensorTip MTX was not able to reliably measure blood pressure compared to blood pressure obtained with an arterial catheter and therefore, the measurement performance is not clinically acceptable. Moreover, a high malfunction rate makes the device unsuitable for use in perioperative period. Cardiol Res. 2022;13(6):372-379 doi: https://doi.org/10.14740/cr1438
- 1 December 2022
- Published by Elmer Press, Inc. in Cardiology Research
- Vol. 13 (6) , 372-379
Open AccessPerioperative Validation of the TensorTip™ MTX Device for Noninvasive Arterial Pressure Measurement: A Method Comparison Study
Background: The noninvasive TensorTip™ MTX measures blood pressure by interpreting blood diffusion color of the finger skin. In addition to blood pressure, the device is able to measure various vital signs: heart rate, oxygen saturation, stroke volume, and cardiac output. Studies about accuracy and precision thus far available have only been conducted by the manufacturer. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in comparison to invasive radial artery blood pressure values. Methods: Forty-one patients scheduled for elective surgery were enrolled in this study. Placement of the arterial catheter had to be part of the standard of care. Once hemodynamic stable conditions were achieved, blood pressure was measured. Three measurements with the TensorTip MTX were averaged and compared with one invasive blood pressure measurement using Bland-Altman plot and error grid analysis. Results: Systolic, diastolic, and mean blood pressure had a bias of respectively 6.2, -6.9 and 4.4 mm Hg. Corresponding standard deviation were respectively 30.1, 17.0 and 22.2. Calculated percentage errors were 47.6%, 52.9% and 52.3%. Proportional bias was present in all Bland-Altman analyses. Error grid analysis showed 61.0% of systolic blood pressure measurements, and 46.3% of mean blood pressure measurements were in the clinical acceptable zone. Conclusions: The TensorTip MTX was not able to reliably measure blood pressure compared to blood pressure obtained with an arterial catheter and therefore, the measurement performance is not clinically acceptable. Moreover, a high malfunction rate makes the device unsuitable for use in perioperative period. Cardiol Res. 2022;13(6):372-379 doi: https://doi.org/10.14740/cr1438
- Open Access
- 19 September 2022
- Published by Springer Nature in Respiratory Research
- Vol. 23 (1) , 1-9
Safety during interhospital helicopter transfer of ventilated COVID-19 patients. No clinical relevant changes in vital signs including non-invasive cardiac output
Background: During the COVID-19 pandemic in The Netherlands, critically ill ventilated COVID-19 patients were transferred not only between hospitals by ambulance but also by the Helicopter Emergency Medical Service (HEMS). To date, little is known about the physiological impact of helicopter transport on critically ill patients and COVID-19 patients in particular. This study was conducted to explore the impact of inter-hospital helicopter transfer on vital signs of mechanically ventilated patients with severe COVID-19, with special focus on take-off, midflight, and landing. Methods: All ventilated critically ill COVID-19 patients who were transported between April 2020 and June 2021 by the Dutch ‘Lifeliner 5’ HEMS team and who were fully monitored, including noninvasive cardiac output, were included in this study. Three 10-min timeframes (take-off, midflight and landing) were defined for analysis. Continuous data on the vital parameters heart rate, peripheral oxygen saturation, arterial blood pressure, end-tidal CO2 and noninvasive cardiac output using electrical cardiometry were collected and stored at 1-min intervals. Data were analyzed for differences over time within the timeframes using one-way analysis of variance. Significant differences were checked for clinical relevance. Results: Ninety-eight patients were included in the analysis. During take-off, an increase was noticed in cardiac output (from 6.7 to 8.2 L min−1; P < 0.0001), which was determined by a decrease in systemic vascular resistance (from 1071 to 739 dyne·s·cm−5, P < 0.0001) accompanied by an increase in stroke volume (from 88.8 to 113.7 mL, P < 0.0001). Other parameters were unchanged during take-off and mid-flight. During landing, cardiac output and stroke volume slightly decreased (from 8.0 to 6.8 L min−1, P < 0.0001 and from 110.1 to 84.4 mL, P < 0.0001, respectively), and total systemic vascular resistance increased (P < 0.0001). Though statistically significant, the found changes were small and not clinically relevant to the medical status of the patients as judged by the attending physicians. Conclusions: Interhospital helicopter transfer of ventilated intensive care patients with COVID-19 can be performed safely and does not result in clinically relevant changes in vital signs.
- 19 September 2022
- Published by Springer Nature in Respiratory Research
- Vol. 23 (1) , 1-9
Open AccessSafety during interhospital helicopter transfer of ventilated COVID-19 patients. No clinical relevant changes in vital signs including non-invasive cardiac output
Background: During the COVID-19 pandemic in The Netherlands, critically ill ventilated COVID-19 patients were transferred not only between hospitals by ambulance but also by the Helicopter Emergency Medical Service (HEMS). To date, little is known about the physiological impact of helicopter transport on critically ill patients and COVID-19 patients in particular. This study was conducted to explore the impact of inter-hospital helicopter transfer on vital signs of mechanically ventilated patients with severe COVID-19, with special focus on take-off, midflight, and landing. Methods: All ventilated critically ill COVID-19 patients who were transported between April 2020 and June 2021 by the Dutch ‘Lifeliner 5’ HEMS team and who were fully monitored, including noninvasive cardiac output, were included in this study. Three 10-min timeframes (take-off, midflight and landing) were defined for analysis. Continuous data on the vital parameters heart rate, peripheral oxygen saturation, arterial blood pressure, end-tidal CO2 and noninvasive cardiac output using electrical cardiometry were collected and stored at 1-min intervals. Data were analyzed for differences over time within the timeframes using one-way analysis of variance. Significant differences were checked for clinical relevance. Results: Ninety-eight patients were included in the analysis. During take-off, an increase was noticed in cardiac output (from 6.7 to 8.2 L min−1; P < 0.0001), which was determined by a decrease in systemic vascular resistance (from 1071 to 739 dyne·s·cm−5, P < 0.0001) accompanied by an increase in stroke volume (from 88.8 to 113.7 mL, P < 0.0001). Other parameters were unchanged during take-off and mid-flight. During landing, cardiac output and stroke volume slightly decreased (from 8.0 to 6.8 L min−1, P < 0.0001 and from 110.1 to 84.4 mL, P < 0.0001, respectively), and total systemic vascular resistance increased (P < 0.0001). Though statistically significant, the found changes were small and not clinically relevant to the medical status of the patients as judged by the attending physicians. Conclusions: Interhospital helicopter transfer of ventilated intensive care patients with COVID-19 can be performed safely and does not result in clinically relevant changes in vital signs.
- Open Access
- 12 April 2022
- Published by Springer Nature in Intensive Care Medicine
- Vol. 48 (6) , 756-758
Time course of physiological variables during inter-hospital helicopter transport of ventilated COVID-19 patients
- 12 April 2022
- Published by Springer Nature in Intensive Care Medicine
- Vol. 48 (6) , 756-758
Open AccessTime course of physiological variables during inter-hospital helicopter transport of ventilated COVID-19 patients
- 1 February 2022
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 39 (2) , 170-173
Prolonged peri-operative use of radial artery applanation tonometry for cardiac output measurement during abdominal surgery
- 1 February 2022
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 39 (2) , 170-173
Prolonged peri-operative use of radial artery applanation tonometry for cardiac output measurement during abdominal surgery
- Open Access
- 24 January 2022
- Published by Springer Nature in Research Square
Vital Signs of Severe COVID-19 Patients During Inter-Hospital Helicopter Transfer
Background: During the COVID-19 pandemic in The Netherlands, critically ill ventilated COVID-19 patients were transferred not only between hospitals by ambulance but also by the Helicopter Emergency Medical Service (HEMS). To date, little is known about the impact of helicopter transport on critically ill patients and COVID-19 patients in particular. This study was conducted to explore the impact of inter-hospital helicopter transfer on vital signs of mechanically ventilated severe COVID-19 intensive care patients, with special focus on take-off, midflight, and landing.Methods: All ventilated critically ill COVID-19 patients who were transported between April 2020 and June 2021 by the Dutch ‘Lifeliner 5’ HEMS team and who were fully monitored, including noninvasive cardiac output, were included in this study. Three 10-minute timeframes (take-off, midflight and landing) were defined for analysis. Continuous data on the vital parameters heart rate, peripheral oxygen saturation, arterial blood pressure, end-tidal CO2 and noninvasive cardiac output using electrical cardiometry were collected and stored at 1-minute intervals. Data were analydzed for differences over time within the timeframes using 1-way analysis of variance. Significant differences were checked for clinical relevance.Results: Ninety-eight patients were included in the analysis. During take-off, an increase was noticed in cardiac output (from 6.7 to 8.1 Lmin-1; P−5, P-1, PConclusions: Interhospital helicopter transfer of ventilated intensive care patients with COVID-19 can be performed safely and does not result in clinically relevant changes in vital signs. This study was assessed by the medical ethical committee Arnhem-Nijmegen, the Netherlands (identifier 2021-7313). The committee waived the need for informed consent. The study was registered at www.trialregister.nl (identifier NL9307).
- 24 January 2022
- Published by Springer Nature in Research Square
Open AccessVital Signs of Severe COVID-19 Patients During Inter-Hospital Helicopter Transfer
Background: During the COVID-19 pandemic in The Netherlands, critically ill ventilated COVID-19 patients were transferred not only between hospitals by ambulance but also by the Helicopter Emergency Medical Service (HEMS). To date, little is known about the impact of helicopter transport on critically ill patients and COVID-19 patients in particular. This study was conducted to explore the impact of inter-hospital helicopter transfer on vital signs of mechanically ventilated severe COVID-19 intensive care patients, with special focus on take-off, midflight, and landing.Methods: All ventilated critically ill COVID-19 patients who were transported between April 2020 and June 2021 by the Dutch ‘Lifeliner 5’ HEMS team and who were fully monitored, including noninvasive cardiac output, were included in this study. Three 10-minute timeframes (take-off, midflight and landing) were defined for analysis. Continuous data on the vital parameters heart rate, peripheral oxygen saturation, arterial blood pressure, end-tidal CO2 and noninvasive cardiac output using electrical cardiometry were collected and stored at 1-minute intervals. Data were analydzed for differences over time within the timeframes using 1-way analysis of variance. Significant differences were checked for clinical relevance.Results: Ninety-eight patients were included in the analysis. During take-off, an increase was noticed in cardiac output (from 6.7 to 8.1 Lmin-1; P−5, P-1, PConclusions: Interhospital helicopter transfer of ventilated intensive care patients with COVID-19 can be performed safely and does not result in clinically relevant changes in vital signs. This study was assessed by the medical ethical committee Arnhem-Nijmegen, the Netherlands (identifier 2021-7313). The committee waived the need for informed consent. The study was registered at www.trialregister.nl (identifier NL9307).
- Open Access
- 3 August 2021
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 29 (1) , 1-4
An Approved Landing Site (ALS) improves the logistics of interhospital transfer of critically ill patients by helicopter
The COVID-19 pandemic limited hospital resources and necessitated interhospital transport of ICU-patients in order to provide critical care to all patients in the Netherlands. However, not all hospitals have an approved landing site. The ICU-transport operation was executed under HEMS-license and landing on non-aerodrome terrain was permitted. This allowed the search for an ad-hoc landing site in the direct vicinity of the ICU. The following characteristics were judged: slope, obstacles, size, soil conditions and the presence of foreign objects.Before the start of this transport operation, in two days, all hospitals in the Netherlands were visited and presumed landing sites explored, described, photographed and recorded in the electronic flight bag. At 71 (87,6 %) of the hospitals it was possible to install a temporary approved landing site in the direct vicinity of the ICU. 110 landings were made on these landing sites and 114 landings on approved heliports. Only 11 patients required secondary transport to or from the helicopter landings site. This occurred only in two patients from a heliport to a receiving hospital.The construction of pre-explored approved landing sites in the vicinity of hospitals allows safe transportation of patients by helicopter to hospitals without a heliport.
- 3 August 2021
- Published by Springer Nature in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
- Vol. 29 (1) , 1-4
Open AccessAn Approved Landing Site (ALS) improves the logistics of interhospital transfer of critically ill patients by helicopter
The COVID-19 pandemic limited hospital resources and necessitated interhospital transport of ICU-patients in order to provide critical care to all patients in the Netherlands. However, not all hospitals have an approved landing site. The ICU-transport operation was executed under HEMS-license and landing on non-aerodrome terrain was permitted. This allowed the search for an ad-hoc landing site in the direct vicinity of the ICU. The following characteristics were judged: slope, obstacles, size, soil conditions and the presence of foreign objects.Before the start of this transport operation, in two days, all hospitals in the Netherlands were visited and presumed landing sites explored, described, photographed and recorded in the electronic flight bag. At 71 (87,6 %) of the hospitals it was possible to install a temporary approved landing site in the direct vicinity of the ICU. 110 landings were made on these landing sites and 114 landings on approved heliports. Only 11 patients required secondary transport to or from the helicopter landings site. This occurred only in two patients from a heliport to a receiving hospital.The construction of pre-explored approved landing sites in the vicinity of hospitals allows safe transportation of patients by helicopter to hospitals without a heliport.