Armando Gallegos Mun˜oz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Armando Gallegos Mun˜oz has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
- Juan Manuel Belman Flores
Grupo de Investigación IRSE, Departamento de Ingeniería Mecánica, División de Ingenierías, Campus Irapuato-Salamanca, Universidad de Guanajuato, Salamanca-Valle de Santiago km. 3.5+1.8, Salamanca C.P. 36885, Guanajuato, Mexico
13 shared publications - Jorge Arturo Alfaro Ayala
University of Guanajuato, Department of Chemical Engineering, Mexico, Guanajuato, Guanajuato
7 shared publications - María Teresa Parra-Santos
University of Valladolid, Department of Energy and Fluid Mechanics, Valladolid, Spain
6 shared publications - Victor Hugo Rangel-Hernandez
Department of Mechanical Engineering, Engineering Division, Campus Irapuato-Salamanca, University of Guanajuato, Salamanca 36885, Mexico
6 shared publications Alfonso Campos-Amezcua
Instituto de Investigaciones Electricas, Cuernavaca, MOR, México
4 shared publicationsN. C. Uzarraga-Rodriguez
University of Guanajuato, Salamanca, GUA, México
4 shared publications
Latest Publications
- Open Access
- 8 August 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2277
Synthesis of Composites for the Removal of F- Anions
This work presents the synthesis of amine and ferrihydrite functionalized graphene oxide for the removal of fluoride from water. The synthesis of the graphene oxide and the modified with amine groups is developed by following the modified Hummer’s method. Fourier transform infrared spectrometry, X-ray, Raman spectroscopy, thermogravimetric analysis, surface charge distribution, specific surface area and porosity, adsorption isotherms, and the van’t Hoff equation are used for the characterization of the synthesized materials. Results show that the addition of amines with ferrihydrite generates wrinkles on the surface layers, suggesting a successful incorporation of nitrogen onto the graphene oxide; and as a consequence, the adsorption capacity per unit area of the materials is increased.
- 8 August 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (16) , 2277
Open AccessSynthesis of Composites for the Removal of F- Anions
This work presents the synthesis of amine and ferrihydrite functionalized graphene oxide for the removal of fluoride from water. The synthesis of the graphene oxide and the modified with amine groups is developed by following the modified Hummer’s method. Fourier transform infrared spectrometry, X-ray, Raman spectroscopy, thermogravimetric analysis, surface charge distribution, specific surface area and porosity, adsorption isotherms, and the van’t Hoff equation are used for the characterization of the synthesized materials. Results show that the addition of amines with ferrihydrite generates wrinkles on the surface layers, suggesting a successful incorporation of nitrogen onto the graphene oxide; and as a consequence, the adsorption capacity per unit area of the materials is increased.
- Open Access
- 9 November 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (22) , 3942
Graphene-Based Adsorbents for Arsenic, Fluoride, and Chromium Adsorption: Synthesis Methods Review
Water contamination around the world is an increasing problem due to the presence of contaminants such as arsenic, fluoride, and chromium. The presence of such contaminants is related to either natural or anthropogenic processes. The above-mentioned problem has motivated the search for strategies to explore and develop technologies to remove these contaminants in water. Adsorption is a common process employed for such proposals due to its versatility, high adsorption capacity, and lower cost. In particular, graphene oxide is a material that is of special interest due to its physical and chemical properties such as surface area, porosity, pore size as well as removal efficiency for several contaminants. This review shows the advances, development, and perspectives of materials based on GO employed for the adsorption of contaminants such as arsenite, arsenate, fluoride, and hexavalent chromium. We provided a detailed discussion of the synthesis techniques and their relationship with the adsorption capacities and other physical properties as well as pH ranges employed to remove the contaminants. It is concluded that the adsorption capacity is not proportional to the surface area in all the cases; instead, the synthesis method, as well as the functional groups, play an important role. In particular, the sol–gel synthesis method shows better adsorption capacities.
- 9 November 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (22) , 3942
Open AccessGraphene-Based Adsorbents for Arsenic, Fluoride, and Chromium Adsorption: Synthesis Methods Review
Water contamination around the world is an increasing problem due to the presence of contaminants such as arsenic, fluoride, and chromium. The presence of such contaminants is related to either natural or anthropogenic processes. The above-mentioned problem has motivated the search for strategies to explore and develop technologies to remove these contaminants in water. Adsorption is a common process employed for such proposals due to its versatility, high adsorption capacity, and lower cost. In particular, graphene oxide is a material that is of special interest due to its physical and chemical properties such as surface area, porosity, pore size as well as removal efficiency for several contaminants. This review shows the advances, development, and perspectives of materials based on GO employed for the adsorption of contaminants such as arsenite, arsenate, fluoride, and hexavalent chromium. We provided a detailed discussion of the synthesis techniques and their relationship with the adsorption capacities and other physical properties as well as pH ranges employed to remove the contaminants. It is concluded that the adsorption capacity is not proportional to the surface area in all the cases; instead, the synthesis method, as well as the functional groups, play an important role. In particular, the sol–gel synthesis method shows better adsorption capacities.
- Open Access
- 3 October 2022
- Published by Brazilian Journals in STUDIES IN MULTIDISCIPLINARY REVIEW
- Vol. 3 (4) , 849-864
Análisis en un intercambiador de calor usando diferentes modelos de turbulencia y correlaciones
En este trabajo se presenta el análisis teórico-numérico de la transferencia de calor de un intercambiador de calor comercial de carcasa y tubos para el calentamiento de agua residencial, aplicando diferentes correlaciones para el flujo interno y externo, además de diferentes modelos de turbulencia. En el análisis teórico se aplica el método ε-NTU y para el análisis numérico se utiliza el método de volumen finito (CFD). Para los coeficientes convectivos internos se aplican las correlaciones de Colburn, Petukov-Kirillov, Dittus Boelter y Gnielinski y para los coeficientes convectivos externos las correlaciones de Zukauskas, Kern, Hilpert y Taborek. Los modelos de turbulencia aplicados son: k-epsilon, Reynolds Strees, k-omega y Large Eddy Simulation. Los resultados teóricos y numéricos obtenidos para la temperatura de salida en carcasa y tubos, al combinar diferentes correlaciones y modelos de turbulencia, se comparan con los datos que ofrece el fabricante, seleccionándose aquellos modelos que presentan una mejor aproximación con los datos del fabricante. También se analiza el comportamiento de flujo en el interior del intercambiador para observar las trayectorias del flujo, tanto dentro de tubos como en la carcasa, identificando las zonas de baja transferencia de calor entre fluidos.
- 3 October 2022
- Published by Brazilian Journals in STUDIES IN MULTIDISCIPLINARY REVIEW
- Vol. 3 (4) , 849-864
Open AccessAnálisis en un intercambiador de calor usando diferentes modelos de turbulencia y correlaciones
En este trabajo se presenta el análisis teórico-numérico de la transferencia de calor de un intercambiador de calor comercial de carcasa y tubos para el calentamiento de agua residencial, aplicando diferentes correlaciones para el flujo interno y externo, además de diferentes modelos de turbulencia. En el análisis teórico se aplica el método ε-NTU y para el análisis numérico se utiliza el método de volumen finito (CFD). Para los coeficientes convectivos internos se aplican las correlaciones de Colburn, Petukov-Kirillov, Dittus Boelter y Gnielinski y para los coeficientes convectivos externos las correlaciones de Zukauskas, Kern, Hilpert y Taborek. Los modelos de turbulencia aplicados son: k-epsilon, Reynolds Strees, k-omega y Large Eddy Simulation. Los resultados teóricos y numéricos obtenidos para la temperatura de salida en carcasa y tubos, al combinar diferentes correlaciones y modelos de turbulencia, se comparan con los datos que ofrece el fabricante, seleccionándose aquellos modelos que presentan una mejor aproximación con los datos del fabricante. También se analiza el comportamiento de flujo en el interior del intercambiador para observar las trayectorias del flujo, tanto dentro de tubos como en la carcasa, identificando las zonas de baja transferencia de calor entre fluidos.
- 14 February 2020
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 12 (4) , 1-29
Transient Study of the Cooling Process of a Small Cabinet
A transient study of the cooling process inside a cabinet is presented in this work. Computational fluid dynamics (CFD) is used to obtain the transient temperature of the air inside a small cabinet. Three cooling levels, named Case 1, Case 2, and Case 3, were studied under different lapses of time and operational conditions. The temperature of the evaporator plate and the temperature of the room change with time through the implementation of user-defined functions (UDFs). The buoyancy effects that occur inside the cabinet (natural convection) were modeled using the approximation of all the properties fitted to temperature polynomials (PFTP). The transient temperature of the air inside the cabinet was obtained, until the second ON/OFF stage is reached, for the three cases studied. The prediction of the transient temperature of the air inside the small cabinet was validated with experimental data. The average relative errors of the transient temperatures of the air inside the cabinet were 0.49%, 0.19%, and 0.13% for Case 1, Case 2, and Case 3, respectively. The behavior of the temperature and velocity distributions of the air inside the cabinet for the ON and OFF stages is obtained. Finally, a better range of the temperature for the preservation of food, medicines, and biological matter is obtained with an increase in the thickness of the insulation material. An increment of 14.9% of the removed energy was obtained inside the cabinet with 12 cm of the insulation material, and this increment is related to the case with no insulation material. The results of this work could help in improving the design and performance of the cabinets in further works.
- 14 February 2020
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 12 (4) , 1-29
Transient Study of the Cooling Process of a Small Cabinet
A transient study of the cooling process inside a cabinet is presented in this work. Computational fluid dynamics (CFD) is used to obtain the transient temperature of the air inside a small cabinet. Three cooling levels, named Case 1, Case 2, and Case 3, were studied under different lapses of time and operational conditions. The temperature of the evaporator plate and the temperature of the room change with time through the implementation of user-defined functions (UDFs). The buoyancy effects that occur inside the cabinet (natural convection) were modeled using the approximation of all the properties fitted to temperature polynomials (PFTP). The transient temperature of the air inside the cabinet was obtained, until the second ON/OFF stage is reached, for the three cases studied. The prediction of the transient temperature of the air inside the small cabinet was validated with experimental data. The average relative errors of the transient temperatures of the air inside the cabinet were 0.49%, 0.19%, and 0.13% for Case 1, Case 2, and Case 3, respectively. The behavior of the temperature and velocity distributions of the air inside the cabinet for the ON and OFF stages is obtained. Finally, a better range of the temperature for the preservation of food, medicines, and biological matter is obtained with an increase in the thickness of the insulation material. An increment of 14.9% of the removed energy was obtained inside the cabinet with 12 cm of the insulation material, and this increment is related to the case with no insulation material. The results of this work could help in improving the design and performance of the cabinets in further works.
- Open Access
- 11 September 2019
- Published by IntechOpen
Exhaust Gas Heat Recovery for an ORC: A Case Study
This work aims at developing a heat exchanger (HEX) sizing approach considering the need to maximize the heat recovery within the limitations of pressure drop and space. The application consists in the recovery of the energy contained in exhaust gases coming from an internal combustion engine (ICE). Two heat exchanger geometries are selected as case studies. The design approach involves the application of design of experiments (DOE) techniques and computational fluid dynamics (CFD) simulations. DOE techniques are used to observe the influence of some selected parameters (factors) in the design of the heat exchangers, and CFD simulations are carried out to determine the performance of the heat exchanger. The information obtained is used to determine local Nusselt number correlations that are used for the design of the heat exchangers.
- 11 September 2019
- Published by IntechOpen
Open AccessExhaust Gas Heat Recovery for an ORC: A Case Study
This work aims at developing a heat exchanger (HEX) sizing approach considering the need to maximize the heat recovery within the limitations of pressure drop and space. The application consists in the recovery of the energy contained in exhaust gases coming from an internal combustion engine (ICE). Two heat exchanger geometries are selected as case studies. The design approach involves the application of design of experiments (DOE) techniques and computational fluid dynamics (CFD) simulations. DOE techniques are used to observe the influence of some selected parameters (factors) in the design of the heat exchangers, and CFD simulations are carried out to determine the performance of the heat exchanger. The information obtained is used to determine local Nusselt number correlations that are used for the design of the heat exchangers.
- Open Access
Perspectives on Consumer Habits with Domestic Refrigerators and Its Consequences for Energy Consumption: Case of Study in Guanajuato, Mexico
This work presents the main behaviors shown in the habits of consumers of domestic refrigerators, which influences the energy consumption of this appliance. This study is based on a series of surveys answered by 200 consumers from four cities in the State of Guanajuato, Mexico. The questions were arranged with the aim of evaluating the general characteristics and usage habits such as refrigerator age, door opening frequency, damper position, load of food supplies, external and internal cleaning habits, and nearby heat sources, among other things. The randomly interviewed consumers were individuals between 20 and 60 years of age, who were interviewed using handmade surveys by experts in the field of refrigeration. In some cases, photographic evidence was gathered from the consumers’ refrigerators to represent the typical usage habits. In general, the results show that better usage habits are necessary from an energy point of view. Most consumers agree with adopting best practices for using their refrigerator.
Open AccessPerspectives on Consumer Habits with Domestic Refrigerators and Its Consequences for Energy Consumption: Case of Study in Guanajuato, Mexico
This work presents the main behaviors shown in the habits of consumers of domestic refrigerators, which influences the energy consumption of this appliance. This study is based on a series of surveys answered by 200 consumers from four cities in the State of Guanajuato, Mexico. The questions were arranged with the aim of evaluating the general characteristics and usage habits such as refrigerator age, door opening frequency, damper position, load of food supplies, external and internal cleaning habits, and nearby heat sources, among other things. The randomly interviewed consumers were individuals between 20 and 60 years of age, who were interviewed using handmade surveys by experts in the field of refrigeration. In some cases, photographic evidence was gathered from the consumers’ refrigerators to represent the typical usage habits. In general, the results show that better usage habits are necessary from an energy point of view. Most consumers agree with adopting best practices for using their refrigerator.
- Open Access
- 12 May 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 143, 02089
A numerical study of the influence of solidity on the performance of vertical axis turbine
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 12 May 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 143, 02089
Open AccessA numerical study of the influence of solidity on the performance of vertical axis turbine
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- Open Access
Second Law Analysis of a Mobile Air Conditioning System with Internal Heat Exchanger Using Low GWP Refrigerants
This paper investigates the results of a Second Law analysis applied to a mobile air conditioning system (MACs) integrated with an internal heat exchanger (IHX) by considering R152a, R1234yf and R1234ze as low global warming potential (GWP) refrigerants and establishing R134a as baseline. System simulation is performed considering the maximum value of entropy generated in the IHX. The maximum entropy production occurs at an effectiveness of 66% for both R152a and R134a, whereas for the cases of R1234yf and R1234ze occurs at 55%. Sub-cooling and superheating effects are evaluated for each one of the cases. It is also found that the sub-cooling effect shows the greatest impact on the cycle efficiency. The results also show the influence of isentropic efficiency on relative exergy destruction, resulting that the most affected components are the compressor and the condenser for all of the refrigerants studied herein. It is also found that the most efficient operation of the system resulted to be when using the R1234ze refrigerant.
Open AccessSecond Law Analysis of a Mobile Air Conditioning System with Internal Heat Exchanger Using Low GWP Refrigerants
This paper investigates the results of a Second Law analysis applied to a mobile air conditioning system (MACs) integrated with an internal heat exchanger (IHX) by considering R152a, R1234yf and R1234ze as low global warming potential (GWP) refrigerants and establishing R134a as baseline. System simulation is performed considering the maximum value of entropy generated in the IHX. The maximum entropy production occurs at an effectiveness of 66% for both R152a and R134a, whereas for the cases of R1234yf and R1234ze occurs at 55%. Sub-cooling and superheating effects are evaluated for each one of the cases. It is also found that the sub-cooling effect shows the greatest impact on the cycle efficiency. The results also show the influence of isentropic efficiency on relative exergy destruction, resulting that the most affected components are the compressor and the condenser for all of the refrigerants studied herein. It is also found that the most efficient operation of the system resulted to be when using the R1234ze refrigerant.
- Open Access
Thermal Simulation of the Fresh Food Compartment in a Domestic Refrigerator
In the field of domestic refrigeration, it is important to look for methods that can be used to simulate, and, thus, improve the thermal behavior of the fresh food compartment. In this sense, this study proposes some methods to model the thermal behavior of this compartment when the shelves’ positions are changed. Temperature measurements at specific locations in this compartment were obtained. Several shelf position combinations were performed to use three 2D interpolation methods in order to simulate the temperature mean and the temperature variance. The methods used were: Lagrange’s interpolation, cubic spline interpolation and bilinear interpolation. Two validation points were chosen to verify the proposed methods. By comparing the experimental results with the computer simulations, it was possible to conclude that the method of Lagrange’s interpolation provided values that were not close to the real measured values. On the other hand, it was observed that the method of bilinear interpolation offered the best results, estimating values which were very close to the actual experimental measurements. These interpolation methods were used to build color thermal graphs that can be used to find some of the most appropriate shelf position combinations in this type of refrigerator. By inspection of these thermal graphs, it can be seen that the lowest average temperature was obtained when one shelf was located at 24.5 cm while the second shelf was located at 29.5 cm measured from the top of the compartment. In the same way, it can be seen that the minimum temperature variance was obtained when only one shelf was inside the compartment and this shelf was located at 29.5 cm.
Open AccessThermal Simulation of the Fresh Food Compartment in a Domestic Refrigerator
In the field of domestic refrigeration, it is important to look for methods that can be used to simulate, and, thus, improve the thermal behavior of the fresh food compartment. In this sense, this study proposes some methods to model the thermal behavior of this compartment when the shelves’ positions are changed. Temperature measurements at specific locations in this compartment were obtained. Several shelf position combinations were performed to use three 2D interpolation methods in order to simulate the temperature mean and the temperature variance. The methods used were: Lagrange’s interpolation, cubic spline interpolation and bilinear interpolation. Two validation points were chosen to verify the proposed methods. By comparing the experimental results with the computer simulations, it was possible to conclude that the method of Lagrange’s interpolation provided values that were not close to the real measured values. On the other hand, it was observed that the method of bilinear interpolation offered the best results, estimating values which were very close to the actual experimental measurements. These interpolation methods were used to build color thermal graphs that can be used to find some of the most appropriate shelf position combinations in this type of refrigerator. By inspection of these thermal graphs, it can be seen that the lowest average temperature was obtained when one shelf was located at 24.5 cm while the second shelf was located at 29.5 cm measured from the top of the compartment. In the same way, it can be seen that the minimum temperature variance was obtained when only one shelf was inside the compartment and this shelf was located at 29.5 cm.
- Open Access
- 28 March 2016
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 114, 02088
Numerical study on small scale vertical axis wind turbine
EPJ Web of Conferences, open-access proceedings in physics and related sciences
- 28 March 2016
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 114, 02088
Open AccessNumerical study on small scale vertical axis wind turbine
EPJ Web of Conferences, open-access proceedings in physics and related sciences