AVAlexander I. Veress

Alexander I. Veress

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander I. Veress has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Novel Methodology for Measuring Regional Myocardial Efficiency

    by Grant T. Gullberg, Uttam M. Shrestha, Alexander I. Veress, W. Paul Segars, Jing Liu, Karen Ordovas, Youngho Seo

    Our approach differs from the usual global measure of cardiac efficiency by using PET/MRI to measure efficiency of small pieces of cardiac tissue whose limiting size is equal to the spatial resolution of the PET scanner. We initiated a dynamic cardiac PET study immediately prior to the injection of 15.1 mCi of 11 C-acetate acquiring data for 25 minutes while simultaneously acquiring MRI cine data. 1) A 3D finite element (FE) biomechanical model of the imaged heart was constructed by utilizing nonrigid deformable image registration to alter the Dassault Systèmes FE Living Heart Model (LHM) to fit the geometry in the cardiac MRI cine data. The patient specific FE cardiac model with estimates of stress, strain, and work was transformed into PET/MRI format. 2) A 1-tissue compartment model was used to calculate wash-in (K 1 ) and the linear portion of the decay in the PET 11 C-acetate time activity curve (TAC) was used to calculate the wash-out k 2 (mono) rate constant. K 1 was used to calculate blood flow and k 2 (mono) was used to calculate myocardial volume oxygen consumption ( MV O 2 ). 3) Estimates of stress and strain were used to calculate Myocardial Equivalent Minute Work ( MEMW ) and Cardiac Efficiency = MEMW / MV O 2 was then calculated for 17 tissue segments of the left ventricle. The global MBF was 0.96 ± 0.15 ml/min/gm and MV O 2 ranged from 8 to 17 ml/100gm/min. Six central slices of the MRI cine data provided a range of MEMW of 0.1 to 0.4 joules/gm/min and a range of Cardiac Efficiency of 6 to 18%.


  • The Direct Incorporation of Perfusion Defect Information to Define Ischemia and Infarction in a Finite Element Model of the Left Ventricle

    by Alexander I. Veress, George S. K. Fung, Taek-Soo Lee, Benjamin M. W. Tsui, Gregory A. Kicska, W. Paul Segars, Grant T. Gullberg

    This paper describes the process in which complex lesion geometries (specified by computer generated perfusion defects) are incorporated in the description of nonlinear finite element (FE) mechanical models used for specifying the motion of the left ventricle (LV) in the 4D extended cardiac torso (XCAT) phantom to simulate gated cardiac image data. An image interrogation process was developed to define the elements in the LV mesh as ischemic or infarcted based upon the values of sampled intensity levels of the perfusion maps. The intensity values were determined for each of the interior integration points of every element of the FE mesh. The average element intensity levels were then determined. The elements with average intensity values below a user-controlled threshold were defined as ischemic or infarcted depending upon the model being defined. For the infarction model cases, the thresholding and interrogation process were repeated in order to define a border zone (BZ) surrounding the infarction. This methodology was evaluated using perfusion maps created by the perfusion cardiac-torso (PCAT) phantom an extension of the 4D XCAT phantom. The PCAT was used to create 3D perfusion maps representing 90% occlusions at four locations (left anterior descending (LAD) segments 6 and 9, left circumflex (LCX) segment 11, right coronary artery (RCA) segment 1) in the coronary tree. The volumes and shapes of the defects defined in the FE mechanical models were compared with perfusion maps produced by the PCAT. The models were incorporated into the XCAT phantom. The ischemia models had reduced stroke volume (SV) by 18–59 ml. and ejection fraction (EF) values by 14–50% points compared to the normal models. The infarction models, had less reductions in SV and EF, 17–54 ml. and 14–45% points, respectively. The volumes of the ischemic/infarcted regions of the models were nearly identical to those volumes obtained from the perfusion images and were highly correlated (R2 = 0.99).


  • Generation of a suite of 3D computer‐generated breast phantoms from a limited set of human subject data

    by Christina M. L. Hsu, Mark L. Palmeri, W. Paul Segars, Alexander I. Veress, James T. Dobbins

    Purpose:: The authors previously reported on a three‐dimensional computer‐generated breast phantom, based on empirical human image data, including a realistic finite‐element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n = 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared.Methods:: Several mesh‐based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the “base” and “target” for morphing. Several combinations of transformations were applied to morph between the “base’ and “target” datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty‐two simulated mammograms, generated from morphing three human subject datasets, were used in a preliminary observer evaluation where four board certified breast radiologists with varying amounts of experience ranked the level of realism (from 1 = “fake” to 10 = “real”) of the simulated images.Results:: The morphing technique was able to successfully generate new and unique morphed datasets from the original human subject data. The radiologists evaluated the realism of simulated mammograms generated from the morphed and unmorphed human subject datasets and scored the realism with an average ranking of 5.87 ± 1.99, confirming that overall the phantom image datasets appeared more “real” than “fake.” Moreover, there was not a significant difference (p > 0.1) between the realism of the unmorphed datasets (6.0 ± 1.95) compared to the morphed datasets (5.86 ± 1.99). Three of the four observers had overall average rankings of 6.89 ± 0.89, 6.9 ± 1.24, 6.76 ± 1.22, whereas the fourth observer ranked them noticeably lower at 2.94 ± 0.7.Conclusions:: This work presents a technique that can be used to generate a suite of realistic computerized breast phantoms from a limited number of human subjects. This suite of flexible breast phantoms can be used for multimodality imaging research to provide a known truth while concurrently producing realistic simulated imaging data.


  • Open Access

    A Comparison of Hyperelastic Warping of PET Images with Tagged MRI for the Analysis of Cardiac Deformation

    by Alexander I. Veress, Gregory Klein, Grant T. Gullberg

    The objectives of the following research were to evaluate the utility of a deformable image registration technique known as hyperelastic warping for the measurement of local strains in the left ventricle through the analysis of clinical, gated PET image datasets. Two normal human male subjects were sequentially imaged with PET and tagged MRI imaging. Strain predictions were made for systolic contraction using warping analyses of the PET images and HARP based strain analyses of the MRI images. Coefficient of determinationR2values were computed for the comparison of circumferential and radial strain predictions produced by each methodology. There was good correspondence between the methodologies, withR2values of 0.78 for the radial strains of both hearts and from anR2=0.81andR2=0.83for the circumferential strains. The strain predictions were not statistically different(P≤0.01). A series of sensitivity results indicated that the methodology was relatively insensitive to alterations in image intensity, random image noise, and alterations in fiber structure. This study demonstrated that warping was able to provide strain predictions of systolic contraction of the LV consistent with those provided by tagged MRI Warping.


  • An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom

    by Christina M. L. Hsu, Mark L. Palmeri, W. Paul Segars, Alexander I. Veress, James T. Dobbins

    Purpose : The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In the current study, they have evaluated a finite element(FE) model of compression and have demonstrated the effect of a variety of mechanical properties on the model using a dense mesh generated from empirical breast data. While several groups have demonstrated an effective compression simulation with lower density finite element meshes, the presented study offers a mesh density that is able to model the morphology of the inner breast structures more realistically than lower density meshes. This approach may prove beneficial for multimodality breast imaging research, since it provides a high level of anatomical detail throughout the simulation study. Methods : In this paper, the authors describe methods to improve the high-resolution performance of a FE compression model. In order to create the compressible breast phantom, dedicated breast CT data was segmented and a mesh was generated with 4-noded tetrahedral elements. Using an explicit FE solver to simulate breast compression, several properties were analyzed to evaluate their effect on the compression model including: mesh density, element type, density, and stiffness of various tissue types, friction between the skin and the compression plates, and breast density. Following compression, a simulated projection was generated to demonstrate the ability of the compressible breast phantom to produce realistic simulated mammographicimages. Results : Small alterations in the properties of the breast model can change the final distribution of the tissue under compression by more than 1 cm; which ultimately results in different representations of the breast model in the simulated images. The model properties that impact displacement the most are mesh density, friction between the skin and the plates, and the relative stiffness of the different tissue types. Conclusions : The authors have developed a 3D, FE breast model that can yield high spatial resolution breast deformations under uniaxial compression for imaging research purposes and demonstrated that small changes in the mechanical properties can affect images generated using the phantom.


  • Incorporation of a Left Ventricle Finite Element Model Defining Infarction Into the XCAT Imaging Phantom

    by Alexander I. Veress, W. Paul Segars, Benjamin M. W. Tsui, Grant T. Gullberg

    The 4D extended cardiac-torso (XCAT) phantom was developed to provide a realistic and flexible model of the human anatomy and cardiac and respiratory motions for use in medical imaging research. A prior limitation to the phantom was that it did not accurately simulate altered functions of the heart that result from cardiac pathologies such as coronary artery disease (CAD). We overcame this limitation in a previous study by combining the phantom with a finite-element (FE) mechanical model of the left ventricle (LV) capable of more realistically simulating regional defects caused by ischemia. In the present work, we extend this model giving it the ability to accurately simulate motion abnormalities caused by myocardial infarction (MI), a far more complex situation in terms of altered mechanics compared with the modeling of acute ischemia. The FE model geometry is based on high resolution CT images of a normal male subject. An anterior region was defined as infarcted and the material properties and fiber distribution were altered, according to the bio-physiological properties of two types of infarction, i.e., fibrous and remodeled infarction (30% thinner wall than fibrous case). Compared with the original, surface-based 4D beating heart model of the XCAT, where regional abnormalities are modeled by simply scaling down the motion in those regions, the FE model was found to provide a more accurate representation of the abnormal motion of the LV due to the effects of fibrous infarction as well as depicting the motion of remodeled infarction. In particular, the FE models allow for the accurate depiction of dyskinetic motion. The average circumferential strain results were found to be consistent with measured dyskinetic experimental results. Combined with the 4D XCAT phantom, the FE model can be used to produce realistic multimodality sets of imaging data from a variety of patients in which the normal or abnormal cardiac function is accurately represented.


  • Strain measurement in the left ventricle during systole with deformable image registration

    by Nikhil S. Phatak, Steve A. Maas, Alexander I. Veress, Nathan A. Pack, Edward V.R. Di Bella, Jeffrey A. Weiss


  • Measuring Regional Changes in the Diastolic Deformation of the Left Ventricle of SHR Rats Using microPET Technology and Hyperelastic Warping

    by Alexander I. Veress, Jeffrey A. Weiss, Ronald H. Huesman, Bryan W. Reutter, Scott E. Taylor, Arek Sitek, Bing Feng, Yongfeng Yang, Grant T. Gullberg


  • Noninvasive Determination of Ligament Strain with Deformable Image Registration

    by Nikhil S. Phatak, Qunli Sun, Seong-Eun Kim, Dennis L. Parker, R. Kent Sanders, Alexander I. Veress, Benjamin J. Ellis, Jeffrey A. Weiss

    Ligament function and propensity for injury are directly related to regional stresses and strains. However, noninvasive techniques for measurement of strain are currently limited. This study validated the use of Hyperelastic Warping, a deformable image registration technique, for noninvasive strain measurement in the human medial collateral ligament using direct comparisons with optical measurements. Hyperelastic Warping determines the deformation map that aligns consecutive images of a deforming material, allowing calculation of strain. Diffeomorphic deformations are ensured by representing the deformable image as a hyperelastic material. Ten cadaveric knees were subjected to six loading scenarios each. Tissue deformation was documented with magnetic resonance imaging (MRI) and video-based experimental measurements. MRI datasets were analyzed using Hyperelastic Warping, representing the medial collateral ligament (MCL) with a hexahedral finite element (FE) model projected to a manually segmented ligament surface. The material behavior was transversely isotropic hyperelastic. Warping predictions of fiber stretch were strongly correlated with experimentally measured strains (R 2 = 0.81). Both sets of measurements were in agreement with previous ex vivo studies. Warping predictions of fiber stretch were insensitive to bulk:shear modulus ratio, fiber stiffness, and shear modulus in the range of +2.5SD to −1.0SD. Correlations degraded when the shear modulus was decreased to 2.5SD below the mean (R 2 = 0.56), and when an isotropic constitutive model was substituted for the transversely isotropic model (R 2 = 0.65). MCL strains in the transitional region near the joint line, where the material behavior and material symmetry are more complex, showed the most sensitivity to changes in shear modulus. These results demonstrate that Hyperelastic Warping requires the use of a constitutive model that reflects the material symmetry, but not subject-specific material properties for accurate strain predictions for this application. Hyperelastic Warping represents a powerful technique for noninvasive strain measurement of musculoskeletal tissues and has many advantages over other image-based strain measurement techniques.


  • Normal and Pathological NCAT Image and Phantom Data Based on Physiologically Realistic Left Ventricle Finite-Element Models

    by Alexander I. Veress, W. Paul Segars, Jeffrey A. Weiss, Benjamin M. W. Tsui, Grant T. Gullberg

    The four-dimensional (4-D) NURBS-based cardiac-torso (NCAT) phantom, which provides a realistic model of the normal human anatomy and cardiac and respiratory motions, is used in medical imaging research to evaluate and improve imaging devices and techniques, especially dynamic cardiac applications. One limitation of the phantom is that it lacks the ability to accurately simulate altered functions of the heart that result from cardiac pathologies such as coronary artery disease (CAD). The goal of this work was to enhance the 4-D NCAT phantom by incorporating a physiologically based, finite-element (FE) mechanical model of the left ventricle (LV) to simulate both normal and abnormal cardiac motions. The geometry of the FE mechanical model was based on gated high-resolution X-ray multislice computed tomography (MSCT) data of a healthy male subject. The myocardial wall was represented as a transversely isotropic hyperelastic material, with the fiber angle varying from -90deg at the epicardial surface, through 0deg at the midwall, to 90deg at the endocardial surface. A time-varying elastance model was used to simulate fiber contraction, and physiological intraventricular systolic pressure-time curves were applied to simulate the cardiac motion over the entire cardiac cycle. To demonstrate the ability of the FE mechanical model to accurately simulate the normal cardiac motion as well as the abnormal motions indicative of CAD, a normal case and two pathologic cases were simulated and analyzed. In the first pathologic model, a subendocardial anterior ischemic region was defined. A second model was created with a transmural ischemic region defined in the same location. The FE-based deformations were incorporated into the 4-D NCAT cardiac model through the control points that define the cardiac structures in the phantom which were set to move according to the predictions of the mechanical model. A simulation study was performed using the FE-NCAT combination to investigate how the differences in contractile function between the subendocardial and transmural infarcts manifest themselves in myocardial Single photon emission computed tomography (SPECT) images. The normal FE model produced strain distributions that were consistent with those reported in the literature and a motion consistent with that defined in the normal 4-D NCAT beating heart model based on tagged magnetic resonance imaging (MRI) data. The addition of a subendocardial ischemic region changed the average transmural circumferential strain from a contractile value of -0.09 to a tensile value of 0.02. The addition of a transmural ischemic region changed average circumferential strain to a value of 0.13, which is consistent with data reported in the literature. Model results demonstrated differences in contractile function between subendocardial and transmural infarcts and how these differences in function are documented in simulated myocardial SPECT images produced using the 4-D NCAT phantom. Compared with the original NCAT beating heart model, the FE mechanical model produced a more accurate simulation for the cardiac motion abnormalities. Such a model, when incorporated into the 4-D NCAT phantom, has great potential for use in cardiac imaging research. With its enhanced physiologically based cardiac model, the 4-D NCAT phantom can be used to simulate realistic, predictive imaging data of a patient population with varying whole-body anatomy and with varying healthy and diseased states of the heart that will provide a known truth from which to evaluate and improve existing and emerging 4-D imaging techniques used in the diagnosis of cardiac disease