Neus Sabater
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neus Sabater has a total of 254 co-authors. Here are the top co-authors by number of shared publications:
- Carles Cane
Institut de Microelectrònica de Barcelona-Centre Nacional de Microelectrònica, Consejo Superior de Investigaciones Científicas (CSIC), 08193 Bellaterra, Spain
60 shared publications - Isabel Gracia
Institute of Microelectronics of Barcelona (IMB-CNM, CSIC), Campus UAB, Cerdanyola del Vallès, 08193 Barcelona, Spain
52 shared publications - Joaquin Santander
Instituto de Microelectrónica de Barcelona, Centro Nacional de Microelectrónica (IMB-CNM, CSIC)
44 shared publications - Juan Pablo Esquivel
Instituto de Microelectrónica de Barcelona
39 shared publications - Luis Fonseca
Instituto de Microelectrónica de Barcelona (Spain)
35 shared publications - Eduardo Figueras
Institute of Microelectronics of Barcelona (IMB-CNM, CSIC), Campus UAB, Cerdanyola del Vallès, 08193 Barcelona, Spain
19 shared publications
Latest Publications
- Open Access
- 16 July 2024
- Published by Elsevier in Sensors and Actuators Reports
- Vol. 8
Unveiling the effect of paper matrix on the electrochemical response of diffusive redox probes
- 16 July 2024
- Published by Elsevier in Sensors and Actuators Reports
- Vol. 8
Open AccessUnveiling the effect of paper matrix on the electrochemical response of diffusive redox probes
- 29 September 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 243, 115708
Towards a REASSURED reality: A less-is-more electronic design strategy for self-powered glucose test
- 29 September 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 243, 115708
Towards a REASSURED reality: A less-is-more electronic design strategy for self-powered glucose test
- Open Access
- 7 November 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 220, 114868
Immuno-battery: A single use self-powered immunosensor for REASSURED diagnostics
- 7 November 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 220, 114868
Open AccessImmuno-battery: A single use self-powered immunosensor for REASSURED diagnostics
- Open Access
- 19 August 2022
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 14 (38) , 14223-14230
Nanoceria dissolution at acidic pH by breaking off the catalytic loop
Experiments at low pH show that nanoceria – widely reported to have catalytic behavior – acts as a pure stoichiometric reagent where insoluble Ce4+ ions transform into soluble Ce3+ in the nanocrystal that finally dissolves.
- 19 August 2022
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 14 (38) , 14223-14230
Open AccessNanoceria dissolution at acidic pH by breaking off the catalytic loop
Experiments at low pH show that nanoceria – widely reported to have catalytic behavior – acts as a pure stoichiometric reagent where insoluble Ce4+ ions transform into soluble Ce3+ in the nanocrystal that finally dissolves.
- Top Cited Papers
- 7 January 2022
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 122 (7) , 7236-7266
Microfluidics for Electrochemical Energy Conversion
Electrochemical energy conversion is an important supplement for storage and on-demand use of renewable energy. In this regard, microfluidics offers prospects to raise the efficiency and rate of electrochemical energy conversion through enhanced mass transport, flexible cell design, and ability to eliminate the physical ion-exchange membrane, an essential yet costly element in conventional electrochemical cells. Since the 2002 invention of the microfluidic fuel cell, the research field of microfluidics for electrochemical energy conversion has expanded into a great variety of cell designs, fabrication techniques, and device functions with a wide range of utility and applications. The present review aims to comprehensively synthesize the best practices in this field over the past 20 years. The underlying fundamentals and research methods are first summarized, followed by a complete assessment of all research contributions wherein microfluidics was proactively utilized to facilitate energy conversion in conjunction with electrochemical cells, such as fuel cells, flow batteries, electrolysis cells, hybrid cells, and photoelectrochemical cells. Moreover, emerging technologies and analytical tools enabled by microfluidics are also discussed. Lastly, opportunities for future research directions and technology advances are proposed.
- 7 January 2022
- Published by American Chemical Society (ACS) in Chemical Reviews
- Vol. 122 (7) , 7236-7266
Top Cited PapersMicrofluidics for Electrochemical Energy Conversion
Electrochemical energy conversion is an important supplement for storage and on-demand use of renewable energy. In this regard, microfluidics offers prospects to raise the efficiency and rate of electrochemical energy conversion through enhanced mass transport, flexible cell design, and ability to eliminate the physical ion-exchange membrane, an essential yet costly element in conventional electrochemical cells. Since the 2002 invention of the microfluidic fuel cell, the research field of microfluidics for electrochemical energy conversion has expanded into a great variety of cell designs, fabrication techniques, and device functions with a wide range of utility and applications. The present review aims to comprehensively synthesize the best practices in this field over the past 20 years. The underlying fundamentals and research methods are first summarized, followed by a complete assessment of all research contributions wherein microfluidics was proactively utilized to facilitate energy conversion in conjunction with electrochemical cells, such as fuel cells, flow batteries, electrolysis cells, hybrid cells, and photoelectrochemical cells. Moreover, emerging technologies and analytical tools enabled by microfluidics are also discussed. Lastly, opportunities for future research directions and technology advances are proposed.
- Open Access
- 21 October 2021
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 6 (4) , 044003
A printed and self-powered test strip for digital conductivity measurement of low volume liquid samples
- 21 October 2021
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 6 (4) , 044003
Open AccessA printed and self-powered test strip for digital conductivity measurement of low volume liquid samples
- Open Access
- 28 September 2021
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (10) , 3650-3656
Self-Powered Potentiometric Sensors with Memory
Potentiometric sensors induce a spontaneous voltage that indicates ion activity in real time. We present here an advanced self-powered potentiometric sensor with memory. Specifically, the approach allows for one to record a deviation from the analyte’s original concentration or determine whether the analyte concentration has surpassed a threshold in a predefined time interval. The sensor achieves this by harvesting energy in a capacitor and preserving it with the help of a diode. While the analyte concentration is allowed to return to an original value following a perturbation over time, this may not influence the sensor readout. To achieve the diode function, the sensor utilizes an additional pair of driving electrodes to move the potentiometric signal to a sufficiently high base voltage that is required for operating the diode placed in series with the capacitor and between the sensing probes. A single voltage measurement across the capacitor at the end of a chosen time interval is sufficient to reveal any altered ion activity occurring during that period. We demonstrate the applicability of the sensor to identify incurred pH changes in a river water sample during an interval of 2 h. This approach is promising for achieving deployable sensors to monitor ion activity relative to a defined threshold during a time interval with minimal electronic components in a self-powered design.
- 28 September 2021
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (10) , 3650-3656
Open AccessSelf-Powered Potentiometric Sensors with Memory
Potentiometric sensors induce a spontaneous voltage that indicates ion activity in real time. We present here an advanced self-powered potentiometric sensor with memory. Specifically, the approach allows for one to record a deviation from the analyte’s original concentration or determine whether the analyte concentration has surpassed a threshold in a predefined time interval. The sensor achieves this by harvesting energy in a capacitor and preserving it with the help of a diode. While the analyte concentration is allowed to return to an original value following a perturbation over time, this may not influence the sensor readout. To achieve the diode function, the sensor utilizes an additional pair of driving electrodes to move the potentiometric signal to a sufficiently high base voltage that is required for operating the diode placed in series with the capacitor and between the sensing probes. A single voltage measurement across the capacitor at the end of a chosen time interval is sufficient to reveal any altered ion activity occurring during that period. We demonstrate the applicability of the sensor to identify incurred pH changes in a river water sample during an interval of 2 h. This approach is promising for achieving deployable sensors to monitor ion activity relative to a defined threshold during a time interval with minimal electronic components in a self-powered design.
- Open Access
- 24 March 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (5) , 2001051
A Self‐Powered Minimalistic Glucometer: A Lean Approach to Sustainable Single‐Use Point‐of‐Care Devices
In this work, a novel glucose quantification strategy is presented in a self‐powered biosensing device. The analyte in the sample is oxidized in an enzymatic fuel cell and the generated charge is transferred to a capacitor. The built‐up capacitor voltage at a specific time can be directly correlated with the concentration of analyte. An electro‐fluidic switch placed on a paper‐based microfluidic channel connects a minimalistic electronic circuit to the fuel cell. The circuit modules discriminate the built‐up capacitor voltage, which corresponds to a particular glucose range. The digital semi‐quantitative result is visualized vía electrochromic displays. As a practical application of this working principle, the self‐powered single‐use device has been designed to perform screening of gestational diabetes mellitus. The device discriminates between healthy (<7.8 mm), pre‐diabetes (>7.8 mm), and diabetes (>11.1 mm) condition providing a reliable result. This single use, printable, and disposable self‐powered glucose biosensing device is autonomous and fully powered by the glucose contained in a 3.5 µL sample. It offers an energy‐saving, environmentally friendly, and low‐cost solution for Point‐of‐Care testing. By replacing the selective enzyme in the fuel cell, this strategy can be used for measuring other health parameters such as creatinine, cholesterol, or uric acid, among others.
- 24 March 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (5) , 2001051
Open AccessA Self‐Powered Minimalistic Glucometer: A Lean Approach to Sustainable Single‐Use Point‐of‐Care Devices
In this work, a novel glucose quantification strategy is presented in a self‐powered biosensing device. The analyte in the sample is oxidized in an enzymatic fuel cell and the generated charge is transferred to a capacitor. The built‐up capacitor voltage at a specific time can be directly correlated with the concentration of analyte. An electro‐fluidic switch placed on a paper‐based microfluidic channel connects a minimalistic electronic circuit to the fuel cell. The circuit modules discriminate the built‐up capacitor voltage, which corresponds to a particular glucose range. The digital semi‐quantitative result is visualized vía electrochromic displays. As a practical application of this working principle, the self‐powered single‐use device has been designed to perform screening of gestational diabetes mellitus. The device discriminates between healthy (<7.8 mm), pre‐diabetes (>7.8 mm), and diabetes (>11.1 mm) condition providing a reliable result. This single use, printable, and disposable self‐powered glucose biosensing device is autonomous and fully powered by the glucose contained in a 3.5 µL sample. It offers an energy‐saving, environmentally friendly, and low‐cost solution for Point‐of‐Care testing. By replacing the selective enzyme in the fuel cell, this strategy can be used for measuring other health parameters such as creatinine, cholesterol, or uric acid, among others.
- Open Access
- 3 September 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2909-2914
Self-Powered Potentiometric Sensor Transduction to a Capacitive Electronic Component for Later Readout
Potentiometric sensors operate as galvanic cells where the voltage is spontaneously generated as a function of the sample composition. We show here that energy can be harvested, stored during the sensing process without external power, and physically isolated from the sensor circuit for later readout. This is accomplished by placing an electronic capacitor as a portable transduction component between the indicator and the reference electrode at the point where one would ordinarily connect the high-input-impedance voltmeter. The voltage across this isolated capacitor indicates the originally measured ion activity and can be read out conveniently, for example, using a simple handheld multimeter. The capacitor is shown to maintain the transferred charge for hours after its complete disconnection from the sensor. The concept is demonstrated to detect the physiological concentrations of K+ in artificial sweat samples. The methodology provides a readout principle that could become very useful in portable form factors and opens possibilities for potentiometric detection in point-of-care applications and inexpensive sensing devices where an external power source is not desired.
- 3 September 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2909-2914
Open AccessSelf-Powered Potentiometric Sensor Transduction to a Capacitive Electronic Component for Later Readout
Potentiometric sensors operate as galvanic cells where the voltage is spontaneously generated as a function of the sample composition. We show here that energy can be harvested, stored during the sensing process without external power, and physically isolated from the sensor circuit for later readout. This is accomplished by placing an electronic capacitor as a portable transduction component between the indicator and the reference electrode at the point where one would ordinarily connect the high-input-impedance voltmeter. The voltage across this isolated capacitor indicates the originally measured ion activity and can be read out conveniently, for example, using a simple handheld multimeter. The capacitor is shown to maintain the transferred charge for hours after its complete disconnection from the sensor. The concept is demonstrated to detect the physiological concentrations of K+ in artificial sweat samples. The methodology provides a readout principle that could become very useful in portable form factors and opens possibilities for potentiometric detection in point-of-care applications and inexpensive sensing devices where an external power source is not desired.
- 3 June 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (6) , 1743-1749
Paper-Based Batteries as Conductivity Sensors for Single-Use Applications
We present a novel approach to measure ionic conductivity with a self-powered strategy. In particular, we propose the use of a paper-based battery as a sensor. The battery sensor unit consists of two electrodes placed side-by-side and cov-ered by a piece of hydrophilic paper strip. The electrodes are externally connected to a resistive element. The addition of the fluid to be sensed – which acts as electrolyte – activates the battery, that generates an output voltage that is de-pendent on the conductivity of the liquid sample. The device, which is conceived as a single use disposable sensor, has been tested with different synthetic and biological liquid samples. The battery sensor effectiveness has been assessed by comparing its performance with a commercial laboratory conductometer. The device opens new avenues for conduc-tivity monitoring in small portable and wearable devices, as it simplifies the number of electronic components and the need of additional power sources.
- 3 June 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (6) , 1743-1749
Paper-Based Batteries as Conductivity Sensors for Single-Use Applications
We present a novel approach to measure ionic conductivity with a self-powered strategy. In particular, we propose the use of a paper-based battery as a sensor. The battery sensor unit consists of two electrodes placed side-by-side and cov-ered by a piece of hydrophilic paper strip. The electrodes are externally connected to a resistive element. The addition of the fluid to be sensed – which acts as electrolyte – activates the battery, that generates an output voltage that is de-pendent on the conductivity of the liquid sample. The device, which is conceived as a single use disposable sensor, has been tested with different synthetic and biological liquid samples. The battery sensor effectiveness has been assessed by comparing its performance with a commercial laboratory conductometer. The device opens new avenues for conduc-tivity monitoring in small portable and wearable devices, as it simplifies the number of electronic components and the need of additional power sources.