NSNeus Sabater

Neus Sabater

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Neus Sabater has a total of 254 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Unveiling the effect of paper matrix on the electrochemical response of diffusive redox probes

    by Dmitry Galyamin, Eduardo Laborda, Juan Pablo Esquivel, Joaquín González, Neus Sabaté


  • Towards a REASSURED reality: A less-is-more electronic design strategy for self-powered glucose test

    by Sunil Kumar Sailapu, Susana Liébana, Irene Merino-Jimenez, Juan Pablo Esquivel, Neus Sabaté


  • Open Access

    Immuno-battery: A single use self-powered immunosensor for REASSURED diagnostics

    by Dmitry Galyamin, Susana Liébana, Juan Pablo Esquivel, Neus Sabaté


  • Open Access

    Nanoceria dissolution at acidic pH by breaking off the catalytic loop

    by Dmitry Galyamin, Lena M. Ernst, Aina Fitó-Parera, Guillem Mira-Vidal, Neus G. Bastús, Neus Sabaté, Victor Puntes

    Experiments at low pH show that nanoceria – widely reported to have catalytic behavior – acts as a pure stoichiometric reagent where insoluble Ce4+ ions transform into soluble Ce3+ in the nanocrystal that finally dissolves.


  • Top Cited Papers

    Microfluidics for Electrochemical Energy Conversion

    by Omar A. Ibrahim, Marina Navarro-Segarra, Pardis Sadeghi, Neus Sabaté, Juan Pablo Esquivel, Erik Kjeang

    Electrochemical energy conversion is an important supplement for storage and on-demand use of renewable energy. In this regard, microfluidics offers prospects to raise the efficiency and rate of electrochemical energy conversion through enhanced mass transport, flexible cell design, and ability to eliminate the physical ion-exchange membrane, an essential yet costly element in conventional electrochemical cells. Since the 2002 invention of the microfluidic fuel cell, the research field of microfluidics for electrochemical energy conversion has expanded into a great variety of cell designs, fabrication techniques, and device functions with a wide range of utility and applications. The present review aims to comprehensively synthesize the best practices in this field over the past 20 years. The underlying fundamentals and research methods are first summarized, followed by a complete assessment of all research contributions wherein microfluidics was proactively utilized to facilitate energy conversion in conjunction with electrochemical cells, such as fuel cells, flow batteries, electrolysis cells, hybrid cells, and photoelectrochemical cells. Moreover, emerging technologies and analytical tools enabled by microfluidics are also discussed. Lastly, opportunities for future research directions and technology advances are proposed.


  • Open Access

    A printed and self-powered test strip for digital conductivity measurement of low volume liquid samples

    by Laura Ortega, Anna Llorella, Juan Pablo Esquivel, Josep Mas-Pla, Neus Sabaté


  • Open Access

    Self-Powered Potentiometric Sensors with Memory

    by Sunil Kumar Sailapu, Neus Sabaté, Eric Bakker

    Potentiometric sensors induce a spontaneous voltage that indicates ion activity in real time. We present here an advanced self-powered potentiometric sensor with memory. Specifically, the approach allows for one to record a deviation from the analyte’s original concentration or determine whether the analyte concentration has surpassed a threshold in a predefined time interval. The sensor achieves this by harvesting energy in a capacitor and preserving it with the help of a diode. While the analyte concentration is allowed to return to an original value following a perturbation over time, this may not influence the sensor readout. To achieve the diode function, the sensor utilizes an additional pair of driving electrodes to move the potentiometric signal to a sufficiently high base voltage that is required for operating the diode placed in series with the capacitor and between the sensing probes. A single voltage measurement across the capacitor at the end of a chosen time interval is sufficient to reveal any altered ion activity occurring during that period. We demonstrate the applicability of the sensor to identify incurred pH changes in a river water sample during an interval of 2 h. This approach is promising for achieving deployable sensors to monitor ion activity relative to a defined threshold during a time interval with minimal electronic components in a self-powered design.


  • Open Access

    A Self‐Powered Minimalistic Glucometer: A Lean Approach to Sustainable Single‐Use Point‐of‐Care Devices

    by Irene Merino‐Jimenez, Anna Llorella, Marina Navarro‐Segarra, Jordi Agramunt, Anna Grandas, Shelley D. Minteer, Juan Pablo Esquivel, Neus Sabaté

    In this work, a novel glucose quantification strategy is presented in a self‐powered biosensing device. The analyte in the sample is oxidized in an enzymatic fuel cell and the generated charge is transferred to a capacitor. The built‐up capacitor voltage at a specific time can be directly correlated with the concentration of analyte. An electro‐fluidic switch placed on a paper‐based microfluidic channel connects a minimalistic electronic circuit to the fuel cell. The circuit modules discriminate the built‐up capacitor voltage, which corresponds to a particular glucose range. The digital semi‐quantitative result is visualized vía electrochromic displays. As a practical application of this working principle, the self‐powered single‐use device has been designed to perform screening of gestational diabetes mellitus. The device discriminates between healthy (<7.8 mm), pre‐diabetes (>7.8 mm), and diabetes (>11.1 mm) condition providing a reliable result. This single use, printable, and disposable self‐powered glucose biosensing device is autonomous and fully powered by the glucose contained in a 3.5 µL sample. It offers an energy‐saving, environmentally friendly, and low‐cost solution for Point‐of‐Care testing. By replacing the selective enzyme in the fuel cell, this strategy can be used for measuring other health parameters such as creatinine, cholesterol, or uric acid, among others.


  • Open Access

    Self-Powered Potentiometric Sensor Transduction to a Capacitive Electronic Component for Later Readout

    by Sunil Kumar Sailapu, Pitchnaree Kraikaew, Neus Sabaté, Eric Bakker

    Potentiometric sensors operate as galvanic cells where the voltage is spontaneously generated as a function of the sample composition. We show here that energy can be harvested, stored during the sensing process without external power, and physically isolated from the sensor circuit for later readout. This is accomplished by placing an electronic capacitor as a portable transduction component between the indicator and the reference electrode at the point where one would ordinarily connect the high-input-impedance voltmeter. The voltage across this isolated capacitor indicates the originally measured ion activity and can be read out conveniently, for example, using a simple handheld multimeter. The capacitor is shown to maintain the transferred charge for hours after its complete disconnection from the sensor. The concept is demonstrated to detect the physiological concentrations of K+ in artificial sweat samples. The methodology provides a readout principle that could become very useful in portable form factors and opens possibilities for potentiometric detection in point-of-care applications and inexpensive sensing devices where an external power source is not desired.


  • Paper-Based Batteries as Conductivity Sensors for Single-Use Applications

    by Laura Ortega, Anna Llorella, Juan Pablo Esquivel, Neus Sabaté

    We present a novel approach to measure ionic conductivity with a self-powered strategy. In particular, we propose the use of a paper-based battery as a sensor. The battery sensor unit consists of two electrodes placed side-by-side and cov-ered by a piece of hydrophilic paper strip. The electrodes are externally connected to a resistive element. The addition of the fluid to be sensed – which acts as electrolyte – activates the battery, that generates an output voltage that is de-pendent on the conductivity of the liquid sample. The device, which is conceived as a single use disposable sensor, has been tested with different synthetic and biological liquid samples. The battery sensor effectiveness has been assessed by comparing its performance with a commercial laboratory conductometer. The device opens new avenues for conduc-tivity monitoring in small portable and wearable devices, as it simplifies the number of electronic components and the need of additional power sources.