Duy Phu Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Duy Phu Tran has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Thierry
Future Industries Institute, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095, Australia
13 shared publications - Andreas Offenhäusser
Forschungszentrum Jülich
7 shared publications - Bernhard Wolfrum
Technical University of Munich
6 shared publications Regina Stockmann
Institute of Complex Systems Bioelectronics, Forschungszentrum Jülich, 52425, Jülich, Germany
5 shared publications- Do Minh Hoat
Institute of Theoretical and Applied Research, Duy Tan University, Ha Noi 100000, Vietnam
4 shared publications Hien D. Tong
4 shared publications
Latest Publications
- Open Access
Metal-Oxide FET Biosensor for Point-of-Care Testing: Overview and Perspective
Metal-oxide semiconducting materials are promising for building high-performance field-effect transistor (FET) based biochemical sensors. The existence of well-established top-down scalable manufacturing processes enables the reliable production of cost-effective yet high-performance sensors, two key considerations toward the translation of such devices in real-life applications. Metal-oxide semiconductor FET biochemical sensors are especially well-suited to the development of Point-of-Care testing (PoCT) devices, as illustrated by the rapidly growing body of reports in the field. Yet, metal-oxide semiconductor FET sensors remain confined to date, mainly in academia. Toward accelerating the real-life translation of this exciting technology, we review the current literature and discuss the critical features underpinning the successful development of metal-oxide semiconductor FET-based PoCT devices that meet the stringent performance, manufacturing, and regulatory requirements of PoCT.
Open AccessMetal-Oxide FET Biosensor for Point-of-Care Testing: Overview and Perspective
Metal-oxide semiconducting materials are promising for building high-performance field-effect transistor (FET) based biochemical sensors. The existence of well-established top-down scalable manufacturing processes enables the reliable production of cost-effective yet high-performance sensors, two key considerations toward the translation of such devices in real-life applications. Metal-oxide semiconductor FET biochemical sensors are especially well-suited to the development of Point-of-Care testing (PoCT) devices, as illustrated by the rapidly growing body of reports in the field. Yet, metal-oxide semiconductor FET sensors remain confined to date, mainly in academia. Toward accelerating the real-life translation of this exciting technology, we review the current literature and discuss the critical features underpinning the successful development of metal-oxide semiconductor FET-based PoCT devices that meet the stringent performance, manufacturing, and regulatory requirements of PoCT.
- 3 January 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (2) , 1256-1263
Integrated Platform Addressing the Finger-Prick Blood Processing Challenges of Point-of-Care Electrical Biomarker Testing
Continued advances in label-free electrical biosensors pave the way to simple, rapid, cost-effective, high-sensitivity, and quantitative biomarker testing at the point-of-care setting that would profoundly transform healthcare. However, implementation in routine diagnostics is faced with significant challenges associated with the inherent requirement for biofluid sample processing before and during testing. We present here a simple yet robust autonomous finger-prick blood sample processing platform integrated with nanoscale field-effect transistor biosensors and demonstrate the feasibility of measuring the SARS-CoV-2 nucleocapsid protein. The 3D-printed platform incorporates a high-yield blood-to-plasma separation module and a delay valve designed to terminate the assay at a specific time. The platform is driven by hydrostatic pressure to efficiently and automatically dispense plasma and washing/measurement buffer to the nanosensors. Our model study demonstrates the feasibility of detecting down to 1.4 pg/mL of the SARS-CoV-2 nucleocapsid protein within 25 min and with only minimal operator intervention.
- 3 January 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (2) , 1256-1263
Integrated Platform Addressing the Finger-Prick Blood Processing Challenges of Point-of-Care Electrical Biomarker Testing
Continued advances in label-free electrical biosensors pave the way to simple, rapid, cost-effective, high-sensitivity, and quantitative biomarker testing at the point-of-care setting that would profoundly transform healthcare. However, implementation in routine diagnostics is faced with significant challenges associated with the inherent requirement for biofluid sample processing before and during testing. We present here a simple yet robust autonomous finger-prick blood sample processing platform integrated with nanoscale field-effect transistor biosensors and demonstrate the feasibility of measuring the SARS-CoV-2 nucleocapsid protein. The 3D-printed platform incorporates a high-yield blood-to-plasma separation module and a delay valve designed to terminate the assay at a specific time. The platform is driven by hydrostatic pressure to efficiently and automatically dispense plasma and washing/measurement buffer to the nanosensors. Our model study demonstrates the feasibility of detecting down to 1.4 pg/mL of the SARS-CoV-2 nucleocapsid protein within 25 min and with only minimal operator intervention.
- 8 July 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (28) , 12279-12287
A simplified point-of-care testing approach for preeclampsia blood biomarkers based on nanoscale field effect transistors
Rapid diagnosis of preeclampsia is necessary to ensure timely administration of appropriate care and prevent the potentially catastrophic complications of the condition affecting both mothers and babies. While the diagnostic superiority of angiogenic blood biomarkers such as placental growth factor has recently been demonstrated, there is an urgent need to develop point-of-care (PoC) technologies that allow rapid, quantitative, and accurate testing for these markers within local communities. Towards addressing this need, here we report on a fully integrated biodiagnostic platform based on nanoscale indium oxide field effect transistor (FET) sensors. The high-performance FET sensors are integrated with blood sample processing cartridges that minimize the need for operator intervention during the assay and eliminate the need for analytical equipment. Within 40 minutes and from 30 μL of blood, the FET platform could reliably measure PlGF with a limit of detection of 0.06 pg mL−1 and a five order of magnitudes dynamic range. Pilot clinical validation in four preeclamptic pregnancies confirmed that the accuracy and reliability of the FET platform, paving the way for further development to a much-needed point-of-care preeclampsia testing.
- 8 July 2021
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 13 (28) , 12279-12287
A simplified point-of-care testing approach for preeclampsia blood biomarkers based on nanoscale field effect transistors
Rapid diagnosis of preeclampsia is necessary to ensure timely administration of appropriate care and prevent the potentially catastrophic complications of the condition affecting both mothers and babies. While the diagnostic superiority of angiogenic blood biomarkers such as placental growth factor has recently been demonstrated, there is an urgent need to develop point-of-care (PoC) technologies that allow rapid, quantitative, and accurate testing for these markers within local communities. Towards addressing this need, here we report on a fully integrated biodiagnostic platform based on nanoscale indium oxide field effect transistor (FET) sensors. The high-performance FET sensors are integrated with blood sample processing cartridges that minimize the need for operator intervention during the assay and eliminate the need for analytical equipment. Within 40 minutes and from 30 μL of blood, the FET platform could reliably measure PlGF with a limit of detection of 0.06 pg mL−1 and a five order of magnitudes dynamic range. Pilot clinical validation in four preeclamptic pregnancies confirmed that the accuracy and reliability of the FET platform, paving the way for further development to a much-needed point-of-care preeclampsia testing.
- 1 March 2020
- Published by Elsevier in Physica E: Low-dimensional Systems and Nanostructures
- Vol. 117
Electronic, optical and photocatalytic properties of fully hydrogenated GeC monolayer
- 1 March 2020
- Published by Elsevier in Physica E: Low-dimensional Systems and Nanostructures
- Vol. 117
Electronic, optical and photocatalytic properties of fully hydrogenated GeC monolayer
- 1 January 2020
- Published by Elsevier in Optical Materials
- Vol. 99
Electronic and optical properties of wide band gap Tl3TaS4: A promising surface acoustic wave material
- 1 January 2020
- Published by Elsevier in Optical Materials
- Vol. 99
Electronic and optical properties of wide band gap Tl3TaS4: A promising surface acoustic wave material
- 1 January 2020
- Published by Elsevier in Superlattices and Microstructures
- Vol. 137
Surface functionalization of GeC monolayer with F and Cl: Electronic and optical properties
- 1 January 2020
- Published by Elsevier in Superlattices and Microstructures
- Vol. 137
Surface functionalization of GeC monolayer with F and Cl: Electronic and optical properties
- Open Access
- 12 December 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (70) , 41058-41065
Electronic and optical properties of Janus ZrSSe by density functional theory
In the present work, we investigate systematically the electronic and optical properties of Janus ZrSSe using first-principles calculations. Our calculations demonstrate that the Janus ZrSSe monolayer is an indirect semiconductor at equilibrium. The band gap of the Janus ZrSSe is 1.341 eV using the Heyd–Scuseria–Ernzerhof hybrid functional, larger than the band gap of ZrSe2 monolayer and smaller than that of ZrS2 monolayer. Based on the analysis of the band edge alignment, we confirm that the Janus ZrSSe monolayer possesses photocatalytic activities that can be used in water splitting applications. While strain engineering plays an important role in modulating the electronic properties and optical characteristics of the Janus ZrSSe monolayer, the influence of the external electric field on these properties is negligible. The biaxial strain, εb, has significantly changed the band of the Janus ZrSSe monolayer, and particularly, the semiconductor–metal phase transition which occurred at εb = 7%. The Janus ZrSSe monolayer can absorb light in both visible and ultraviolet regions. Also, the biaxial strain has shifted the first optical gap of the Janus ZrSSe monolayer. Our findings provide additional information for the prospect of applying the Janus ZrSSe monolayer in nanoelectronic devices, especially in water splitting technology.
- 12 December 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (70) , 41058-41065
Open AccessElectronic and optical properties of Janus ZrSSe by density functional theory
In the present work, we investigate systematically the electronic and optical properties of Janus ZrSSe using first-principles calculations. Our calculations demonstrate that the Janus ZrSSe monolayer is an indirect semiconductor at equilibrium. The band gap of the Janus ZrSSe is 1.341 eV using the Heyd–Scuseria–Ernzerhof hybrid functional, larger than the band gap of ZrSe2 monolayer and smaller than that of ZrS2 monolayer. Based on the analysis of the band edge alignment, we confirm that the Janus ZrSSe monolayer possesses photocatalytic activities that can be used in water splitting applications. While strain engineering plays an important role in modulating the electronic properties and optical characteristics of the Janus ZrSSe monolayer, the influence of the external electric field on these properties is negligible. The biaxial strain, εb, has significantly changed the band of the Janus ZrSSe monolayer, and particularly, the semiconductor–metal phase transition which occurred at εb = 7%. The Janus ZrSSe monolayer can absorb light in both visible and ultraviolet regions. Also, the biaxial strain has shifted the first optical gap of the Janus ZrSSe monolayer. Our findings provide additional information for the prospect of applying the Janus ZrSSe monolayer in nanoelectronic devices, especially in water splitting technology.
- Open Access
- 5 November 2019
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 1 (12) , 4870-4877
High performance indium oxide nanoribbon FETs: mitigating devices signal variation from batch fabrication
High performance indium oxide nanoribbon FETs: mitigating device-to-device signal variation in the subthreshold regime.
- 5 November 2019
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 1 (12) , 4870-4877
Open AccessHigh performance indium oxide nanoribbon FETs: mitigating devices signal variation from batch fabrication
High performance indium oxide nanoribbon FETs: mitigating device-to-device signal variation in the subthreshold regime.
- 4 September 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (19) , 12568-12573
Silicon Nanowires Field Effect Transistors: A Comparative Sensing Performance between Electrical Impedance and Potentiometric Measurement Paradigms
- 4 September 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (19) , 12568-12573
Silicon Nanowires Field Effect Transistors: A Comparative Sensing Performance between Electrical Impedance and Potentiometric Measurement Paradigms
- Open Access
- 24 June 2019
- Published by Wiley in Vietnam Journal of Chemistry
- Vol. 57 (3) , 328-333
Possible detection of antibiotic residue using molecularly imprinted polyaniline‐based sensor
Molecular imprinted polymer (MIP) nanowires were deposited on a gold electrode by electro‐polymerization using aniline monomer as reagent and chloramphenicol (CAP) as template molecules. The molecular template was then electrochemically removed to generate the cavities on the polyaniline matrix that enables a specific recognition of CAP. The morphology, structure and electrochemical properties of the MIP were characterized by SEM, FT‐IR and cyclic voltammetry. The initial results show that the MIP sensor can detect 10‐7 mM of CAP and the limit of detection could be lower by performing recommended study.
- 24 June 2019
- Published by Wiley in Vietnam Journal of Chemistry
- Vol. 57 (3) , 328-333
Open AccessPossible detection of antibiotic residue using molecularly imprinted polyaniline‐based sensor
Molecular imprinted polymer (MIP) nanowires were deposited on a gold electrode by electro‐polymerization using aniline monomer as reagent and chloramphenicol (CAP) as template molecules. The molecular template was then electrochemically removed to generate the cavities on the polyaniline matrix that enables a specific recognition of CAP. The morphology, structure and electrochemical properties of the MIP were characterized by SEM, FT‐IR and cyclic voltammetry. The initial results show that the MIP sensor can detect 10‐7 mM of CAP and the limit of detection could be lower by performing recommended study.