HPHarry Huiz Peeters

Harry Huiz Peeters

*This is an algorithmically generated author record based on publicly available information.

Harry Huiz Peeters has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Visualizing the velocity fields and fluid behavior of a solution using artificial intelligence during EndoActivator activation

    by Harry Huiz Peeters, Elvira Theola Judith, Faber Yosua Silitonga, Lavi Rizki Zuhal

    Background: Electrical devices driven sonically have been found in several studies to be effective to clean root canals but the effect of the EndoActivator irrigant activation flow behavior on cleaning efficacy is not completely understood. Purpose: The study aimed to provide an initial understanding of flow behavior and velocity field generation during the irrigant activation process by EndoActivator using artificial intelligence (AI). Methods: A straight glass model was filled with a solution containing 17% EDTA. Meanwhile, a medium activator tip with 22-mm polymer noncutting #25, 0.04 file driven by an electrical sonic hand-piece at 190 Hz (highest level) was used to induce velocity field to produce micro-bubbles. The physical mechanisms involved were recorded using a Miro 320S highspeed imaging system, the hydrodynamic responses were recorded, and analyzed using a motion estimation program supported by LiteFlowNet (AI). Results: The rapid fluid flow was visualized clearly in the model when it was activated by an EndoActivator tip. It was also observed that the distal end of the EndoActivator tip generated a near-wall high gradient velocity apically in all directions of the oscillation. Conclusion: The analysis showed that the proposed motion estimation program, supported by LiteFlowNet (AI), was able to capture velocity magnitude estimation of a non-PIV experiment and visualize the bubbles generated in the solution.


  • Open Access

    Visualization of bubbles generation of electrical-driven EndoActivator tips during solutions activation in a root canal model and a modified extracted tooth: A pilot study

    by Harry Huiz Peeters, Elvira Theola Judith, Ketut Suardita, Latief Mooduto

    Background: EndoActivator, a sonically-driven canal irrigation system (Dentsply Tulsa Dental Specialties, Tulsa, OK), has been developed for activating root canal irrigants, and has recently been released onto the market. Purpose: To obtain an initial understanding of bubbles generation of electrical EndoActivator tips during activation of the irrigant in a transparent root canal model and a modified extracted tooth. Methods: A modified extracted tooth and a straight glass model were filled with a solution containing 17% EDTA or 3% NaOCl. A medium activator tip 22-mm polymer noncutting #25, 0.04 file driven by an electrical sonic hand-piece at 190 Hz (highest level) induced pressure waves that produced macro- and micro-bubbles. The physical mechanisms involved were visualized using a Miro 320S high-speed imaging system (Phantom, Wayne, NJ, USA) with high temporal and spatial resolutions. The imaging system acquired images at 25,000 frames per second with 320×x240 pixels per image, and attached a 60-mm f/2.8 macro lens (Nikon, Tokyo, Japan). Results: The end of the tip did not generate bubbles formation. Disruption of surface tension at the air–solution system in the glass canal model by an electrical sonic driven EndoActivator tip generated bubbles in the solution. However, it did not occur at the system of solution–air interfaces in the glass canal and modified extracted tooth. Conclusion: The physical mechanism of the solution activated by an electrical sonic driven EndoActivator tip in generting bubbles formation is because the surface tension at the air–solution system disruption. No bubbles formation occurred in the solution in the restricted space either in the solution-air system or modified extracted tooth. Better understanding of the physical mechanisms that relate specifically to the activation behaviour of EndoActivator tips in solutions is key to improving the cleaning mechanism that applies during root canal treatment.


  • Open Access

    Extrusion of Irrigant in Open Apex Teeth with Periapical Lesions Following Laser-Activated Irrigation and Passive Ultrasonic Irrigation

    by Harry Huiz Peeters, Ketut Suardita, Latief Mooduto, Norbert Gutknecht

    Sodium hypochlorite (NaOCl) irrigation is critical for the success of endodontic treatment and several agitation techniques have been developed to improve the efficacy of this irrigation. Using a combination of contrast medium and radiographic examination, this study evaluated NaOCl extrusion during agitation of irrigant. Development of pressure, which may result in apical extrusion of the irrigant, has been described during laser-activated irrigation (LAI) and passive ultrasonic irrigation (PUI). We examined 40 single root canals categorized as having open apices with apical lesions in 40 patients. For the final irrigation, the teeth were irrigated with a mixture of radiopaque contrast medium and 2.5% NaOCl in solution. The solution was activated for 60 sec in both groups [the Er, Cr: YSGG laser group (n=20) and the ultrasonic group (n=20)]. The teeth were imaged subsequently using radiography for the evaluation of contrast extrusion. Radiopaque contrast medium was absent from the periapical tissues in all cases. Use of LAI or PUI appears to be safe as used currently in endodontic treatment.


  • Visualization of removal of trapped air from the apical region in simulated root canals by laser-activated irrigation using an Er,Cr:YSGG laser

    by Harry Huiz Peeters, Roeland J. G. De Moor, Djoko Suharto

    The aim of this visualization study was to obtain a better understanding of the mechanism by which trapped air is removed from the apical region of simulated root canals by activation of an irrigant using an erbium, chromium:yttrium–scandium–gallium–garnet (Er,Cr:YSGG) laser during endodontic procedures. A high-speed imaging system with high temporal and spatial resolution was used to visualize laser-induced shock waves in a resin block model with a curved root canal (inner diameter at the apex 0.08 mm, taper 4 %, crown height 10 mm, overall length 40 mm) and a glass cylinder model with a straight root canal (inner diameter 1 mm, crown height 10 mm, overall length 40 mm). The study utilized MZ3 and RFT3 tips in each model, without water or air spray, and with an average power of 1 W at 35 Hz. Laser-activated irrigation overcame the airlock effect by releasing air trapped in the air column. The mechanism underlying the removal of trapped air from the apical region using an Er,Cr:YSGG laser in a dry root canal is via the disruption of the surface tension at the solution–air interface. This disruption, caused by bubble implosion (cavitation), displaces air in the form of bubbles from the apical region toward the solution, which allows the solution to travel apically.


  • Measurement of pressure changes during laser-activated irrigant by an erbium, chromium: yttrium, scandium, gallium, garnet laser

    by Harry Huiz Peeters, Roeland J. G. De Moor

    The use of Er,Cr:YSGG laser to activate irrigants results in the creation of vapour bubbles and shockwaves. The present study evaluated the magnitude of pressure changes in the root canal during laser-activated irrigation. The root canal of a single extracted maxillary canine was enlarged to a size 40/0.06 file. A pressure sensor was inserted apically into the root canal. The tooth was processed as follows. In the EDTA condition, the tooth was irrigated with 17 % EDTA; in the NaOCl condition, the tooth was irrigated with 3 % NaOCl. In all conditions, the irrigants were activated at 0.75 and 1.75 W for 60 s using RFT2 and MZ2 tips; to analyse the effect of tip placement, the tip was activated at the orifice and after inserting the tip 5 mm deeper than the orifice. Data showed no significant difference between irrigation regimens (p > 0.05). There were no significant differences of the pressure between RFT2 and MZ2 tips (p > 0.05). The placement of tips closer to the apex resulted in significantly higher pressure than at the orifice (p < 0.001). The use of 1.75 W power resulted in a significantly higher increase of pressure compared to 0.75 W (p < 0.001), regardless either the type of solutions or tips used. The magnitude of the pressure changes in the root canal at 0.75 W was significantly lower than 1.75 W regardless of either type of tips or solutions used. The closer the insertion of the tip to the apex, the higher the pressure.


  • Efficacy of laser‐driven irrigation versus ultrasonic in removing an airlock from the apical third of a narrow root canal

    by Harry Huiz Peeters, Norbert Gutknecht

    The purpose of the study was to test the hypothesis that air entrapment occurs in the apical third of a root canal during irrigation. A second objective was to test the null hypothesis that there is no difference between laser‐driven irrigation (an erbium, chromium:yttrium‐scandium‐gallium‐garnet laser) and passive ultrasonic irrigation in removing an airlock from the apical third. One hundred twenty extracted human teeth with single narrow root canals were randomised into two experimental groups (n = 40) and two control groups (n = 20). The specimens were shaped using hand instruments up to a size 30/0.02 file. The teeth were irrigated with a mixture of saline, radiopaque contrast and ink in solution. In the passive ultrasonic irrigation group, the irrigant was activated with an ultrasonic device for 60 s. In the laser group, the irrigant was activated with a laser for 60 s. It was concluded that if the insertion of irrigation needle is shorter than the working length, air entrapment may develop in the apical third, but the use of laser‐driven irrigation is completely effective in removing it.


  • Radiographic examination of apical extrusion of root canal irrigants during cavitation induced by Er,Cr:YSGG laser irradiation: an in vivo study

    by Harry Huiz Peeters, Latief Mooduto

    Objectives The purpose of the present study was to test the hypothesis that apical extrusion of the irrigant occurs during laser-driven irrigation in vivo. Materials and methods Three hundred human root canals, in 181 patients, were divided into two groups: the no lesion group (n = 140) and the lesion group (n = 160). All the root canals were enlarged using a crown down technique up to size 30–80 K-files, depending on the original condition of the root canal. For the final irrigation, the teeth were irrigated with a mixture of radiopaque contrast medium and NaOCl in solution. The solution was activated for 60 s in teeth with one canal or two canals and for 120 s in teeth with three or four canals. Results Radiopaque contrast medium was absent from the periapical tissues of all samples. Conclusions No contrast medium was observed radiographically in the periapical tissues. The hypothesis that apical extrusion of root canal irrigants occur during laser cavitation was rejected Clinical relevance It appears that the power of the laser used at 1 W for 1–2 min can drive the irrigation solution to the tip of the canal without harming the apical tissues.


  • Open Access

    Prevalence of a second canal in the mesiobuccal root of permanent maxillary first molars from an Indonesian population

    by Harry H. Peeters, Ketut Suardita, Darmawan Setijanto

    A sample of 308 extracted human permanent maxillary first molars from an Indonesian population was randomly selected. A rhomboid access cavity was made in all teeth in anticipation of identifying a second mesiobuccal canal (MB2). Ultrasonic tips were used to open the subpulpal groove to locate the second canal in the mesiobuccal root. Dentin was carefully removed from the trifurcation area at the expense of the mesial wall. If a second canal was located, a 0.8 C+ file was inserted into it until the file reached the apex. The prevalence of a second canal in the mesiobuccal root of the permanent maxillary first molar was 68.5% (95% CI: 63.1%-73.4%) in this population. Sections of the mesial root showed that the MB2 was a separate canal in 52.6% of the sample and a joined canal in 47.4%. The mean (SD) distance between MB1 and MB2 was 1.55 (0.66) mm. The data obtained from this study provide theoretical and experimental evidence to aid in the clinical management of the MB2 canal and may increase the success rate for root canal treatment of the maxillary first molar. (J Oral Sci 53, 489-494, 2011)