FOFang Ou

Fang Ou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fang Ou has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Simon Swift

    School of Medical Sciences, The University of Auckland, Auckland, 1023, New Zealand

    5 shared publications
  • Anne van Klinken

    Department of Applied Physics, Eindhoven Hendrik Casimir Institute, Eindhoven University of Technology, P.O. Box 513NL, 5600 MB Eindhoven, The Netherlands

    4 shared publications
  • Cushla McGoverin

    Department of Physics, The University of Auckland, Auckland, 1010, New Zealand

    4 shared publications
  • Frédérique Vanholsbeeck

    Department of Physics, The University of Auckland, Auckland, 1010, New Zealand

    4 shared publications
  • Kaylee D. Hakkel

    Department of Applied Physics and Institute for Photonic Integration, Eindhoven University of Technology, PO Box 513, NL 5600 MB Eindhoven, The Netherlands

    4 shared publications
  • Andrea Fiore

    Department of Applied Physics and Eindhoven Hendrik Casimir Institute, at Eindhoven University of Technology

    3 shared publications

Latest Publications

  • Erratum: “High-performance photodetector arrays for near-infrared spectral sensing” [APL Photonics 8, 041302 (2023)]

    by Anne van Klinken, Don M. J. van Elst, Chenhui Li, Maurangelo Petruzzella, Kaylee D. Hakkel, Fang Ou, Francesco Pagliano, René van Veldhoven, Andrea Fiore

  • Open Access

    High-performance photodetector arrays for near-infrared spectral sensing

    by Anne van Klinken, Don M. J. van Elst, Chenhui Li, Maurangelo Petruzzella, Kaylee D. Hakkel, Fang Ou, Francesco Pagliano, René van Veldhoven, Andrea Fiore

    Spectral sensing is an emerging field driven by the need for fast and non-invasive methods for the chemical analysis of materials in agri-food, healthcare, and industrial applications. We demonstrate a near-infrared spectral sensor, based on a scalable fabrication process and combining high responsivity, narrow linewidth, and low noise. The sensor consists of 16 resonant-cavity-enhanced photodetectors, each showing a unique spectral response consisting of narrow peaks. The spectral sensor thereby covers the wavelength range between 890 and 1650 nm, where organic materials show relevant spectral features from first and second overtones. For the fabrication of the detector arrays, we propose a simple and scalable fabrication approach that yields largely improved device characteristics with respect to the grey-scale electron-beam lithography process reported earlier. Through a series of five optical lithography steps, tuning layers of silicon nitride are deposited stepwise to obtain 16 different thicknesses and reduced surface roughness. With this novel fabrication approach, the obtained photodetectors achieve an average peak linewidth of 55 nm, a maximum peak responsivity of 0.3 A/W, and high suppression of the non-resonant background. We also demonstrate the impact of these improvements on the sensing performance for two relevant problems through an experiment and a set of simulations. With lateral dimensions of ∼1.4 × 1.4 mm2, the proposed photodetector array can be the key to robust, portable, and low-cost sensing instrumentation for on-site material analysis in various application fields.


  • Open Access

    Spectral Sensing Using a Handheld NIR Module Based on a Fully Integrated Sensor Chip

    by Fang Ou, Anne van Klinken, Kaylee D. Hakkel, Maurangelo Petruzzella, Don M.J. van Elst, Petar ŠeVo, Chenhui Li, Francesco Pagliano, Rene P.J. van Veldhoven, Andrea Fiore

    Near-infrared (NIR) spectroscopy is widely used for the classification of materials and the quantification of their properties. Today, there is a high demand for extending the use of this technique to portable applications, and eventually, the integration with consumer appliances and smartphones. To reach this goal, the overall size of the NIR sensor, its production cost, robustness, and resistance to vibrations are of particular importance. This paper describes an approach to spectral sensing in the NIR (850–1700 nm) using a handheld sensor module based on a fully integrated multipixel detector array with a footprint of around 2×2 mm2. The capabilities of the spectral sensor module were recently evaluated in two application cases: Quantification of the fat percentage in raw milk and the classification of plastic types. Fat quantification was achieved with a root mean square error (RMSE) of prediction of 0.14% and classification of plastic types was achieved with a prediction accuracy on unknown samples of 100%. The results demonstrate the feasibility of the direct NIR sensing approach used by the integrated sensor, which has potential to be used in a variety of applications.


  • Open Access

    Handheld NIR Spectral Sensor Module Based on a Fully-Integrated Detector Array

    by Fang Ou, Anne van Klinken, Petar Ševo, Maurangelo Petruzzella, Chenhui Li, Don M. J. van Elst, Kaylee D. Hakkel, Francesco Pagliano, Rene P. J. van Veldhoven, Andrea Fiore

    For decades, near-infrared (NIR) spectroscopy has been a valuable tool for material analysis in a variety of applications, ranging from industrial process monitoring to quality assessment. Traditional spectrometers are typically bulky, fragile and expensive, which makes them unsuitable for portable and in-field use. Thus, there is a growing interest for miniaturized, robust and low-cost NIR sensors. In this study, we demonstrate a handheld NIR spectral sensor module, based on a fully-integrated multipixel detector array, sensitive in the 850–1700 nm wavelength range. Differently from a spectrometer, the spectral sensor measures a limited number of NIR spectral bands. The capabilities of the spectral sensor module were evaluated alongside a commercially available portable spectrometer for two application cases: to quantify the moisture content in rice grains and to classify plastic types. Both devices achieved the two sensing tasks with comparable performance. Moisture quantification was achieved with a root mean square error (RMSE) prediction of 1.4% and 1.1% by the spectral sensor and spectrometer, respectively. Classification of the plastic type was achieved with a prediction accuracy on unknown samples of 100% and 96.4% by the spectral sensor and spectrometer, respectively. The results from this study are promising and demonstrate the potential for the compact NIR modules to be used in a variety of NIR sensing applications.


  • Top Cited Papers
    Open Access

    Integrated near-infrared spectral sensing

    by Kaylee D. Hakkel, Maurangelo Petruzzella, Fang Ou, Anne van Klinken, Francesco Pagliano, Tianran Liu, Rene P. J. van Veldhoven, Andrea Fiore

    Spectral sensing is increasingly used in applications ranging from industrial process monitoring to agriculture. Sensing is usually performed by measuring reflected or transmitted light with a spectrometer and processing the resulting spectra. However, realizing compact and mass-manufacturable spectrometers is a major challenge, particularly in the infrared spectral region where chemical information is most prominent. Here we propose a different approach to spectral sensing which dramatically simplifies the requirements on the hardware and allows the monolithic integration of the sensors. We use an array of resonant-cavity-enhanced photodetectors, each featuring a distinct spectral response in the 850-1700 nm wavelength range. We show that prediction models can be built directly using the responses of the photodetectors, despite the presence of multiple broad peaks, releasing the need for spectral reconstruction. The large etendue and responsivity allow us to demonstrate the application of an integrated near-infrared spectral sensor in relevant problems, namely milk and plastic sensing. Our results open the way to spectral sensors with minimal size, cost and complexity for industrial and consumer applications.


  • A novel handheld NIR spectral sensor module for the monitoring of moisture content and for plastic classification

    by Fang Ou, Petar Sevo, Maurangelo Petruzzella, Anne van Klinken, Kaylee D. Hakkel, Don M.J. van Elst, Chenhui Li, Francesco Pagliano, Rene P.J. van Veldhoven, Andrea Fiore

    We present a novel approach to NIR spectral sensing using a handheld module based on a miniaturized integrated detector array. Applicability of the sensor is demonstrated in monitoring moisture in grains and classification of plastics.

  • Open Access

    Rapid and cost-effective evaluation of bacterial viability using fluorescence spectroscopy

    by Fang Ou, Cushla McGoverin, Simon Swift, Frédérique Vanholsbeeck

    A rapid and easy method that takes advantage of an inexpensive and portable fibre-based spectroscopic system (optrode) to determine the ratio of live to dead bacteria is proposed. Mixtures of live and dead Escherichia coli with proportions of live:dead cells varying from 0 to 100% were stained using SYTO 9 and propidium iodide (PI) and measured using the optrode. We demonstrated several approaches to obtaining the proportions of live:dead E. coli in a mixture of both live and dead, from analyses of the fluorescence spectra collected by the optrode. To find a suitable technique for predicting the percentage of live bacteria in a sample, four analysis methods were assessed and compared: SYTO 9:PI fluorescence intensity ratio, an adjusted fluorescence intensity ratio, single-spectrum support vector regression (SVR) and multi-spectra SVR. Of the four analysis methods, multi-spectra SVR obtained the most reliable results and was able to predict the percentage of live bacteria in 108 bacteria/mL samples between c. 7 and 100% live, and in 107 bacteria/mL samples between c. 7 and 73% live. By demonstrating the use of multi-spectra SVR and the optrode to monitor E. coli viability, we raise points of consideration for spectroscopic analysis of SYTO 9 and PI and aim to lay the foundation for future work that uses similar methods for different bacterial species.


  • Bead-Based Flow-Cytometric Cell Counting of Live and Dead Bacteria

    by Fang Ou, Cushla McGoverin, Joni White, Simon Swift, Frédérique Vanholsbeeck

    Flow cytometry (FCM) is based on the detection of scattered light and fluorescence to identify cells with characteristics of interest. Many flow cytometers cannot precisely control the flow through its interrogation point and hence the volume and concentration of the sample cannot be immediately obtained. Here we describe the optimization and evaluation of a bead-based method for absolute cell counting applicable to basic flow cytometers without specialized counting features. Prior to the application of this method to an unknown concentration of a species of bacteria, a calibration experiment should be completed to characterize limits of detection and range of linearity with respect to the plate count method. To demonstrate the calibration process, mixtures of Escherichia coli or Staphylococcus aureus with proportions of live and dead cells ranging from 0% to 100% were prepared. These samples were stained using nucleic acid-binding dyes, and 6 μm reference beads were added (LIVE/DEAD® BacLight kit). The calibration samples were analyzed using bead-based FCM as well as the agar plate count method, and the results from both methods were compared.


  • Open Access

    Near real-time enumeration of live and dead bacteria using a fibre-based spectroscopic device

    by Fang Ou, Cushla McGoverin, Simon Swift, Frédérique Vanholsbeeck

    A rapid, cost-effective and easy method that allows on-site determination of the concentration of live and dead bacterial cells using a fibre-based spectroscopic device (the optrode system) is proposed and demonstrated. Identification of live and dead bacteria was achieved by using the commercially available dyes SYTO 9 and propidium iodide, and fluorescence spectra were measured by the optrode. Three spectral processing methods were evaluated for their effectiveness in predicting the original bacterial concentration in the samples: principal components regression (PCR), partial least squares regression (PLSR) and support vector regression (SVR). Without any sample pre-concentration, PCR achieved the most reliable results. It was able to quantify live bacteria from 108 down to 106.2 bacteria/mL and showed the potential to detect as low as 105.7 bacteria/mL. Meanwhile, enumeration of dead bacteria using PCR was achieved between 108 and 107 bacteria/mL. The general procedures described in this article can be applied or modified for the enumeration of bacteria within populations stained with fluorescent dyes. The optrode is a promising device for the enumeration of live and dead bacterial populations particularly where rapid, on-site measurement and analysis is required.


  • Open Access

    Rapid and cost-effective evaluation of bacterial viability using fluorescence spectroscopy

    by Fang Ou, Cushla McGoverin, Simon Swift, Frédérique Vanholsbeeck

    The fluorescence spectra of bacterial samples stained with SYTO 9 and propidium iodide (PI) were used to monitor bacterial viability. Stained mixtures of live and dead Escherichia coli with proportions of live:dead cells varying from 0 to 100% were measured using the optrode, a cost effective and convenient fibre-based spectroscopic device. We demonstrated several approaches to obtaining the proportions of live:dead E. coli in a mixture of both live and dead, from analyses of the fluorescence spectra collected by the optrode. To find a suitable technique for predicting the percentage of live bacteria in a sample, four analysis methods were assessed and compared: SYTO 9:PI fluorescence intensity ratio, an adjusted fluorescence intensity ratio, single-spectrum support vector regression (SVR) and multi-spectra SVR. Of the four analysis methods, multi-spectra SVR obtained the most reliable results and was able to predict the percentage of live bacteria in 10^8 bacteria/mL samples between c. 7% and 100% live, and in 10^7 bacteria/mL samples between c. 7% and 73% live. By demonstrating the use of multi-spectra SVR and the optrode to monitor E. coli viability, we raise points of consideration for spectroscopic analysis of SYTO 9 and PI and aim to lay the foundation for future work that use similar methods for different bacterial species.