    A Novel Device for Micro-Droplets Generation Based on the Stepwise Membrane Emulsification Principle

    by Lei Lei, Sven Achenbach, Garth Wells, Hongbo Zhang, Wenjun Zhang

    This paper presents a novel design of the device to generate microspheres or micro-droplets based on the membrane emulsification principle. Specifically, the novelty of the device lies in a proposed two-layer or stepwise (by generalization) membrane structure. An important benefit of the stepwise membrane is that it can be fabricated with the low-cost material (SU-8) and using the conventional lithography technology along with a conventional image-based alignment technique. The experiment to examine the effectiveness of the proposed membrane was conducted, and the result shows that microspheres with the size of 2.3 μm and with the size uniformity of 0.8 μm can be achieved, which meets the requirements for most applications in industries. It is noted that the traditional membrane emulsification method can only produce microspheres of around 20 μm. The main contribution of this paper is thus the new design principle of membranes (i.e., stepwise structure), which can be made by the cost-effective fabrication technique, for high performance of droplets production.


  • Open Access

    Microfabrication Process Development for a Polymer-Based Lab-on-Chip Concept Applied in Attenuated Total Reflection Fourier Transform Infrared Spectroelectrochemistry

    by Noah Atkinson, Tyler A. Morhart, Garth Wells, Grace T. Flaman, Eric Petro, Stuart Read, Scott M. Rosendahl, Ian J. Burgess, Sven Achenbach

    Micro electro-mechanical systems (MEMS) combining sensing and microfluidics functionalities, as are common in Lab-on-Chip (LoC) devices, are increasingly based on polymers. Benefits of polymers include tunable material properties, the possibility of surface functionalization, compatibility with many micro and nano patterning techniques, and optical transparency. Often, additional materials, such as metals, ceramics, or silicon, are needed for functional or auxiliary purposes, e.g., as electrodes. Hybrid patterning and integration of material composites require an increasing range of fabrication approaches, which must often be newly developed or at least adapted and optimized. Here, a microfabrication process concept is developed that allows one to implement attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and electrochemistry on an LoC device. It is designed to spatially resolve chemical sensitivity and selectivity, which are instrumental for the detection of chemical distributions, e.g., during on-flow chemical and biological reaction chemistry. The processing sequence involves (i) direct-write and soft-contact UV lithography in SUEX dry resist and replication in polydimethylsiloxane (PDMS) elastomers as the fluidic structure; (ii) surface functionalization of PDMS with oxygen plasma, 3-aminopropyl-triethoxysilane (APTES), and a UV-curable glue (NOA 73) for bonding the fluidic structure to the substrate; (iii) double-sided patterning of silicon nitride-coated silicon wafers serving as the ATR-FTIR-active internal reflection element (IRE) on one side and the electrode-covered substrate for microfluidics on the back side with lift-off and sputter-based patterning of gold electrodes; and (iv) a custom-designed active vacuum positioning and alignment setup. Fluidic channels of 100 μm height and 600 μm width in 5 mm thick PDMS were fabricated on 2” and 4” demonstrators. Electrochemistry on-chip functionality was demonstrated by cyclic voltammetry (CV) of redox reactions involving iron cyanides in different oxidation states. Further, ATR-FTIR measurements of laminar co-flows of H2O and D2O demonstrated the chemical mapping capabilities of the modular fabrication concept of the LoC devices.


  • Fabrication of High-Aspect-Ratio Nanopores in Polymer Membranes: Analysis of Artifacts by Non-Destructive Testing

    by Jose-Alvim Berkenbrock, Matthias Mail, Garth Wells, Torsten Scherer, Sven Achenbach

    Microfluidics is a technology field growing at a high pace which has extended into major areas such as health and agriculture sciences. In these fields, microfluidic devices are employed for analyzing biological samples. Biological structures of interest such as proteins, bacteria, and viruses can be identified with microfluidic detectors. Resistive pulse sensors (RPS) have been long employed for detecting and counting cells. The electric current through a pore is monitored in this method while the target element causes partial and non-permanent obstruction of the pore. Recently, the fabrication of resistive pulse sensors with nanopores (nano-RPS) has been leveraged by advances in micro-and nanofabrication techniques. In this work, a tridimensional numerical model of a nano-RPS is presented. The model validation led to errors lower than 1 % highlighting a shift in pore diameter throughout the fabrication steps. The simulated pattern of electric current during translocation events was also found to be in good agreement with experimental data. Moreover, some fabrication defects were examined. The combination of open-pore current and translocation pattern was suggested to be used for assessing parameters such as the diameter and wall smoothness linked to the quality of fabrication processes.

  • Scanning Aperture Approach for Spatially Selective ATR-FTIR Spectroscopy: Application to Microfluidics

    by Maxime Joly, Tianyang Deng, Tyler A. Morhart, Garth Wells, Sven Achenbach, André Bégin-Drolet, Jesse Greener

    We present a novel spectroscopy accessory that can easily convert any Fourier transform infrared (FTIR) spectrometer into a fully automated mapping and assaying system. The accessory uses a multiridge attenuated total reflection (ATR) wafer as the sensing element coupled with a moving aperture that is used to select the regions of interest on the wafer. In this demonstration, the accessory is combined with a series of parallel micropatterned channels, which are positioned co-linear with the light-coupling ridges on the opposite side of the ATR wafer. The ATR spectroscopy microfluidic assay accessory (ASMAA) was used in continuous mapping mode to scan perpendicular to the ATR ridges, revealing complex but repeatable oscillations in the spectral intensities. To understand this behavior, the light path through the optical components was simulated with consideration of the aperture position, ridge-to-channel alignment, and excitation beam profile. With this approach, the simulation reproduced the experimental mapping results and provided evidence that the measurement position and area changed with the aperture position. To demonstrate the assay mode, we obtained spectra along the centerline of individual microchannels and determined noise baselines and limits of detection.


  • Fabrication and simulations of high-aspect-ratio nanopores for polymer-based resistive pulse sensors

    by Jose-Alvim Berkenbrock, Garth Wells, Matthias Mail, Torsten Scherer, Sven Achenbach

    Microfluidic devices are a class of Micro Electromechanical Systems (MEMS) intended for fluids manipulation, mostly liquids, in the order of microliters and below. The global market of micro and nanofluidic devices has experienced continuous growth over the past few years [1]. In 2020, this market was valued at over USD 4.6 billion in conservative terms, and it is predicted to keep a growth rate of somewhat between 13 and 23% in the next half-decade [2]–[3]. Microdevices are characterized by having at least one dimension in the micrometre range, as well as nanodevices, have it in the nanometer scale. The main applications to micro and nanofluidic devices are drug delivery, pharmaceutical and biotechnology research, clinical and point-of-care (POC) diagnostics [2]. Companies working in this field experienced a surge in demand with the rise of the COVID-19 pandemic. For the rapid testing against SARS-CoV-2, testing devices became necessary for screening populations afar from testing centers and health care facilities [4]–[5]. The development of micro-and nano detectors for new viruses is challenging even with all the background acquired from working with other viruses [6]–[7]. One long-standing detection approach was established in 1953 by W. Coulter for counting cells, a method which is known as Resistive Pulse Sensor (RPS) or Coulter counter [8]. In short, an RPS refers to two chambers filled with electrolyte solution and connected by a single orifice. The target delivered in one chamber shall flow through the orifice to the other chamber led by electrochemical forces. The translocation of the targets causes partial and non-permanent obstruction of the orifice. By monitoring the electric current during this assay, it induces the formation of a pulse-like shape representing a pulse of resistance. In the following decades, this method was adapted to the submicrometric scale with advances in micro-and nanofabrication techniques [9]–[10]. The fabrication of such micro detectors is often based on photolithography, but some emergent and alternative techniques are becoming more common [6, 11–12]. Focused ion beam (FIB) is one of these unconventional approaches that allow for patterning high aspect ratio structures into a mixture of materials [13]–[14]. A challenge to pattern composite materials (e.g., sandwich-like membranes), which might be based on polymers and metals, raises from the different physical properties of materials [15]. The sensitivity and applicability of RPS are directly dependant on the shape and quality of the final structure. For instance, wall smoothness is one of the parameters that should be considered when choosing a fabrication approach. In this work, we will present an advanced nanofabrication design based on focused ion beam technology to drill a nanopore into a polymer-metal-polymer membrane. The intricate structure to be presented in this work was chosen to avoid fabrication artifacts described previously [16]. Numerical simulations will be also provided for comparison with a trivial cylindrical design.

  • Arsenal of microfluidic testing devices may combat COVID-19 pandemic

    by José Alvim Berkenbrock, Rafaela Grecco-Machado, Sven Achenbach


  • On the fabrication of thin-film artificial metal grid resonator antenna arrays using deep x-ray Lithography

    by Waqas Mazhar, David M Klymyshyn, Sven Achenbach, Aqeel A Quershi, Garth Wells, Michael Jacobs, Aqeel Ahmed Qureshi

    In this paper, a unique microfabrication approach for designing high permittivity, high gain and wideband thin-film artificial metal grid dielectric resonator antenna (GDRA) arrays for mm-wave applications is presented. Fabrication of the GDRAs with a strip template frame is based on deep-x-ray lithography (DXRL) using a 500 µ m thick polymethylmethacrylate (PMMA) layer as the photoresist. The simple low-cost fabricated DXRL mask for exposure consisted of gold absorbers patterned by direct-write ultraviolet (UV) laser lithography on a carbon substrate. To avoid the trapping of gas bubbles in the dense, high aspect ratio (HAR) deep grid structures, a novel development approach was introduced utilizing in-vacuum, room temperature dip development to facilitate the collapse of forming gas bubbles. The developed voids were subsequently electroplated to a nickel thickness of 300 µ m to obtain high permittivity artificial dielectrics. The paper describes the entire fabrication sequence. Also, the x-ray mask and DXRL structures are examined for dimensional accuracy and structural quality. This strip template frame approach has superior performance in terms of impedance bandwidth, gain and radiation efficiency as compared to the previously published solid template frame approach. For the purpose of the demonstration, a four-element GDRA array sample was fabricated and tested. A wide measured impedance bandwidth of 5 GHz from 58 GHz to 63 GHz and measured broadside radiation pattern with a peak gain of 10.9 dBi was achieved.


  • Low-Profile Artificial Grid Dielectric Resonator Antenna Arrays for mm-Wave Applications

    by Waqas Mazhar, David M. Klymyshyn, Garth Wells, Aqeel A. Qureshi, Michael Jacobs, Sven Achenbach

    Wideband artificial grid dielectric resonator antenna (GDRA) arrays at 32 GHz for mm-wave applications are presented. The antenna array is comprised of a GDRA layer and a substrate integrated waveguide feeding layer. The GDRA array layer is built by embedding small rectangular metal grid structures in low permittivity dielectric polymethyl methacrylate (PMMA) using deep-X-ray lithography (DXRL) and electroforming. The rectangular metallic inclusions significantly increase the effective permittivity of the base material up to 17 by creating high electric flux density regions inside. Low loss SIW feeding with longitudinal slots is utilized to excite the GDRA array layer. A 200.... thin perforated layer of PMMA is applied between the rectangular grid structures and the SIW feedlines to avoid shorting the metal inclusions to the excitation slots, while improving broadband energy coupling to the GDRA layer. The size of the single GDRA array element is only 2.7mm × 2.7mm × 0.5mm (0.29.o λ 0.29.o λ 0.05.o). Four element (1×4) and eight element (1×8) GDRA arrays have been fabricated and measured. A measured impedance bandwidth of 6 GHz with a broadside peak gain of 12 dBi and 76% measured radiation efficiency is obtained at 32 GHz for the 1×8 GDRA array.


  • SyLMAND: a microfabrication beamline with wide spectral and beam power tuning range at the Canadian Light Source

    by Garth Wells, Sven Achenbach, Venkat Subramanian, Michael Jacobs, David Klymyshyn, Swathi Iyer, Banafsheh Moazed, Jack Hanson, Chen Shen, Darcy Haluzan

    SyLMAND, the Synchrotron Laboratory for Micro and Nano Devices, is a recently commissioned microfabrication bend magnet beamline with ancillary cleanroom facilities at the Canadian Light Source. The synchrotron radiation is applied to pattern high-aspect-ratio polymer microstructures used in the area of micro-electro-mechanical systems (MEMS). SyLMAND particularly focuses on spectral and beam power adjustability and large exposable area formats in an inert gas atmosphere; a rotating-disk intensity chopper allows for independent beam-power reduction, while continuous spectral tuning between 1–2 keV and >15 keV photon energies is achieved using a double-mirror system and low-atomic-number filters. Homogeneous exposure of samples up to six inches in diameter is performed in the experimental endstation, a vertically scanning precision stage (scanner) with tilt and rotation capabilities under 100 mbar helium. Commissioning was completed in late 2017, and SyLMAND is currently ramping up its user program, mostly in the areas of RF MEMS, micro-fluidics/life sciences and micro-optics.


  • Polymer-based X-ray masks patterned by direct laser writing

    by Sven Achenbach, Garth Wells, Michael Jacobs, Banafsheh Moazed, Swathi Iyer, Jack Hanson

    X-ray masks are indispensable tools in deep X-ray lithography (XRL). To date, hardly any fabrication technology can provide affordable and readily available masks with good structure quality. The bottleneck of adequate masks to a large extent limits the widespread use of XRL. In this article, an alternative XRL mask fabrication process is described to significantly improve availability and cost efficiency of XRL masks as key instruments in XRL processing: A 355 nm UV-laser is applied to expose SU-8 resist on an antireflective coating and a copper sacrificial substrate. The voids in this resist template are filled by a two-step electroplating process with sacrificial nickel and 3.6 μm thick gold absorbers. A second SU-8 coat embeds the absorbers, forming the 40 μm mask membrane. This configuration allows for XRL into resists of up to about 200 μm thickness at the SyLMAND beamline, Canada. The absorber structure accuracy is about 1 μm, at smallest tested lateral dimensions of 2 μm isolated features and 500 nm details. Upon release from the substrate, the membrane locally deforms by up to 1.79 μm. PMMA microstructures patterned with such a mask have smooth and vertical sidewalls. The SyLMAND chopper allows one to limit thermal deformations during exposure to the micrometer range: At a beam power of 0.42 W, typical thermal deformations are 0.5 μm–1.4 μm, depending on the layout, and position inaccuracies are about 3.3 μm.