SSSaurav Zaman Khan Sajib

Saurav Zaman Khan Sajib

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Saurav Zaman Khan Sajib has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • Eung Je Woo

    Department of Biomedical Engineering, Kyung Hee University, Seoul, 02447, Korea

    19 shared publications
  • Hyung Joong Kim

    Department of Biomedical Engineering, Kyung Hee University, Seoul, 02447, Korea

    18 shared publications
  • Oh In Kwon

    Affiliation Department of Mathmatics, Konkuk University, Seoul, Korea

    18 shared publications
  • Woo Chul Jeong

    Kyung Hee University 1 Impedance Imaging Research Center and Department of Biomedical Engineering Seoul 02447, Korea

    14 shared publications
  • Tong In Oh

    Kyung Hee University 1 Department of Biomedical Engineering Seoul 02447, South Korea

    8 shared publications
  • Hyung Joong Kim

    Medical Science Research Institute, Kyung Hee University Hospital, Seoul 02447, Republic of Korea

    7 shared publications

Latest Publications

  • Mapping unintended trigeminal nerve activation during transcranial alternating current stimulation (tACS): a computational study

    by Sulagna Sahu, Munish Chauhan, Saurav Z K Sajib, Enock Boakye, Rosalind J Sadleir

    Objective. To systematically characterize activation thresholds for peripheral trigeminal nerve branches under clinical transcranial alternating current stimulation (tACS) parameters using a computational modeling approach. Approach. An MRI-derived finite element head model was coupled with multicompartment NEURON cable models of myelinated sensory axons (4–14 µ m diameter). Seven trigeminal branches were manually delineated. Activation thresholds were computed across eight sinusoidal frequencies (5–100 Hz) for two electrode montages (F3–F4 and Fp1–Fp2). A 60 Hz biphasic pulse enabled direct comparison with established transcutaneous nerve stimulation devices. Sensitivity analyses assessed robustness to nerve orientation and depth, and electrode displacement. Main Results. Threshold decreased non-linearly with increasing frequency, plateauing above 40 Hz. Under F3–F4, the auriculotemporal and zygomaticotemporal nerves, and under Fp1–Fp2, the supraorbital and supratrochlear nerves fell below 2 mA threshold at ⩾40 Hz. Thresholds were largely independent of axon diameter above 40 Hz. Thresholds for 60 Hz sinusoidal waveforms were consistently lower than 60 Hz biphasic pulse condition. Sensitivity analyses confirmed sub-2 mA thresholds were preserved for tested perturbations. Significance. Select trigeminal branches are activated below the standard 2 mA clinical dose across both montages. This study provides preliminary indication that peripheral trigeminal recruitment is a predictable, montage-dependent, and mechanistically plausible contributor to tACS effects that warrants explicit consideration in trial design and result interpretation.

  • Open Access

    Magnetic-resonance-based measurement of electromagnetic fields and conductivity in vivo using single current administration—A machine learning approach

    by Saurav Z. K. Sajib, Munish Chauhan, Oh In Kwon, Rosalind J. Sadleir

    Diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) is a newly developed technique that combines MR-based measurements of magnetic flux density with diffusion tensor MRI (DT-MRI) data to reconstruct electrical conductivity tensor distributions. DT-MREIT techniques normally require injection of two independent current patterns for unique reconstruction of conductivity characteristics. In this paper, we demonstrate an algorithm that can be used to reconstruct the position dependent scale factor relating conductivity and diffusion tensors, using flux density data measured from only one current injection. We demonstrate how these images can also be used to reconstruct electric field and current density distributions. Reconstructions were performed using a mimetic algorithm and simulations of magnetic flux density from complementary electrode montages, combined with a small-scale machine learning approach. In a biological tissue phantom, we found that the method reduced relative errors between single-current and two-current DT-MREIT results to around 10%. Forin vivohuman experimental data the error was about 15%. These results suggest that incorporation of machine learning may make it easier to recover electrical conductivity tensors and electric field images during neuromodulation therapy without the need for multiple current administrations.


  • Conductivity Tensor Imaging of In Vivo Human Brain and Experimental Validation Using Giant Vesicle Suspension

    by Nitish Katoch, Bup Kyung Choi, Saurav Z. K. Sajib, Eun Ah Lee, Hyung Joong Kim, Oh In Kwon, Eung Je Woo

    Human brain mapping of low-frequency electrical conductivity tensors can realize patient-specific volume conductor models for neuroimaging and electrical stimulation. We report experimental validation and in vivo human experiments of a new electrodeless conductivity tensor imaging (CTI) method. From CTI imaging of a giant vesicle suspension using a 9.4 T MRI scanner, the relative error in the reconstructed conductivity tensor image was found to be less than 1.7% compared with the measured value using an impedance analyzer. In vivo human brain imaging experiments of five subjects were followed using a 3 T clinical MRI scanner. With the spatial resolution of 1.87 mm, the white matter conductivity showed considerably more position dependency compared with the gray matter and cerebrospinal fluid (CSF). The anisotropy ratio of the white matter was in the range of 1.96 to 3.25 with mean value of 2.43, whereas that of the gray matter was in the range of 1.12 and 1.19 with mean value of 1.16. The three diagonal components of the reconstructed conductivity tensors were from 0.08 to 0.27 S/m for the white matter, from 0.20 to 0.30 S/m for the gray matter, and from 1.55 to 1.82 S/m for the CSF. The reconstructed conductivity tensor images exhibited significant inter-subject variabilities in terms of frequency and position dependencies. The high-frequency and low-frequency conductivity values can quantify the total and extracellular water contents, respectively, at every pixel. Their difference can quantify the intracellular water content at every pixel. The CTI method can separately quantify the contributions of ion concentrations and mobility to the conductivity tensor.


  • Open Access

    Extracellular Total Electrolyte Concentration Imaging for Electrical Brain Stimulation (EBS)

    by Saurav Z. K. Sajib, Mun Bae Lee, Hyung Joong Kim, Eung Je Woo, Oh In Kwon

    Techniques for electrical brain stimulation (EBS), in which weak electrical stimulation is applied to the brain, have been extensively studied in various therapeutic brain functional applications. The extracellular fluid in the brain is a complex electrolyte that is composed of different types of ions, such as sodium (Na+), potassium (K+), and calcium (Ca+). Abnormal levels of electrolytes can cause a variety of pathological disorders. In this paper, we present a novel technique to visualize the total electrolyte concentration in the extracellular compartment of biological tissues. The electrical conductivity of biological tissues can be expressed as a product of the concentration and the mobility of the ions. Magnetic resonance electrical impedance tomography (MREIT) investigates the electrical properties in a region of interest (ROI) at low frequencies (below 1 kHz) by injecting currents into the brain region. Combining with diffusion tensor MRI (DT-MRI), we analyze the relation between the concentration of ions and the electrical properties extracted from the magnetic flux density measurements using the MREIT technique. By measuring the magnetic flux density induced by EBS, we propose a fast non-iterative technique to visualize the total extracellular electrolyte concentration (EEC), which is a fundamental component of the conductivity. The proposed technique directly recovers the total EEC distribution associated with the water transport mobility tensor.


  • Open Access

    Realistic Electric Field Mapping of Anisotropic Muscle During Electrical Stimulation Using a Combination of Water Diffusion Tensor and Electrical Conductivity

    by Bup Kyung Choi, Tong In Oh, Saurav Zk Sajib, Jin Woong Kim, Hyung Joong Kim, Oh In Kwon, Eung Je Woo

    To realistically map the electric fields of biological tissues using a diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) method to estimate tissue response during electrical stimulation. Imaging experiments were performed using chunks of bovine muscle. Two silver wire electrodes were positioned inside the muscle tissue for electrical stimulation. Electric pulses were applied with a 100-V amplitude and 100-μs width using a voltage stimulator. During electrical stimulation, we collected DT-MREIT data from a 3T magnetic resonance imaging scanner. We adopted the projected current density method to calculate the electric field. Based on the relation between the water diffusion tensor and the conductivity tensor, we computed the position-dependent scale factor using the measured magnetic flux density data. Then, a final conductivity tensor map was reconstructed using the multiplication of the water diffusion tensor and the scale factor. The current density images from DT-MREIT data represent the internal current flows that exist not only in the electrodes but also in surrounding regions. The reconstructed electric filed map from our anisotropic conductivity tensor with the projected current density shows coverage that is more than 2 times as wide, and higher signals in both the electrodes and surrounding tissues, than the previous isotropic method owing to the consideration of tissue anisotropy. An electric field map obtained by an anisotropic reconstruction method showed different patterns from the results of the previous isotropic reconstruction method. Since accurate electric field mapping is important to correctly estimate the coverage of the electrical treatment, future studies should include more rigorous validations of the new method through in vivo and in situ experiments.


  • Open Access

    In vivo mapping of current density distribution in brain tissues during deep brain stimulation (DBS)

    by Saurav Z. K. Sajib, Tong In Oh, Hyung Joong Kim, Oh In Kwon, Eung Je Woo

    New methods for in vivo mapping of brain responses during deep brain stimulation (DBS) are indispensable to secure clinical applications. Assessment of current density distribution, induced by internally injected currents, may provide an alternative method for understanding the therapeutic effects of electrical stimulation. The current flow and pathway are affected by internal conductivity, and can be imaged using magnetic resonance-based conductivity imaging methods. Magnetic resonance electrical impedance tomography (MREIT) is an imaging method that can enable highly resolved mapping of electromagnetic tissue properties such as current density and conductivity of living tissues. In the current study, we experimentally imaged current density distribution of in vivo canine brains by applying MREIT to electrical stimulation. The current density maps of three canine brains were calculated from the measured magnetic flux density data. The absolute current density values of brain tissues, including gray matter, white matter, and cerebrospinal fluid were compared to assess the active regions during DBS. The resulting current density in different tissue types may provide useful information about current pathways and volume activation for adjusting surgical planning and understanding the therapeutic effects of DBS.


  • Open Access

    Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography

    by Saurav Z. K. Sajib, Woo Chul Jeong, Eun Jung Kyung, Tong In Oh, Hyung Joong Kim, Oh In Kwon, Eung Je Woo

    Anisotropy of biological tissues is a low-frequency phenomenon that is associated with the function and structure of cell membranes. Imaging of anisotropic conductivity has potential for the analysis of interactions between electromagnetic fields and biological systems, such as the prediction of current pathways in electrical stimulation therapy. To improve application to the clinical environment, precise approaches are required to understand the exact responses inside the human body subjected to the stimulated currents. In this study, we experimentally evaluate the anisotropic conductivity tensor distribution of canine brain tissues, using a recently developed diffusion tensor-magnetic resonance electrical impedance tomography method. At low frequency, electrical conductivity of the biological tissues can be expressed as a product of the mobility and concentration of ions in the extracellular space. From diffusion tensor images of the brain, we can obtain directional information on diffusive movements of water molecules, which correspond to the mobility of ions. The position dependent scale factor, which provides information on ion concentration, was successfully calculated from the magnetic flux density, to obtain the equivalent conductivity tensor. By combining the information from both techniques, we can finally reconstruct the anisotropic conductivity tensor images of brain tissues. The reconstructed conductivity images better demonstrate the enhanced signal intensity in strongly anisotropic brain regions, compared with those resulting from previous methods using a global scale factor.


  • Open Access

    Enhanced magnetic flux density mapping using coherent steady state equilibrium signal in MREIT

    by Woo Chul Jeong, Mun Bae Lee, Saurav Z. K. Sajib, Hyung Joong Kim, Oh In Kwon, Eung Je Woo

    Measuring the z-component of magnetic flux density B = (Bx, By, Bz) induced by transversally injected current, magnetic resonance electrical impedance tomography (MREIT) aims to visualize electrical property (current density and/or conductivity distribution) in a three-dimensional imaging object. For practical implementations of MREIT technique, it is critical to reduce injection of current pulse within safety requirements. With the goal of minimizing the noise level in measured Bz data, we propose a new method to enhance the measure Bz data using steady-state coherent gradient multi-echo (SSC-GME) MR pulse sequence combining with injection current nonlinear encoding (ICNE) method in MREIT, where the ICNE technique injects current during a readout gradient to maximize the signal intensity of phase signal including Bz. The total phase offset in SSC-GME includes additional magnetic flux density due to the injected current, which is different from the phase signal for the conventional spoiled MR pulse sequence. We decompose the magnetization precession phase from the total phase offset including Bz and optimize Bz data using the steady-state equilibrium signal. Results from a real phantom experiment including different kinds of anomalies demonstrated that the proposed method enhanced Bz comparing to a conventional spoiled pulse sequence.

  • Electric Field Mapping in ex vivo Anisotropic Muscle Tissue Using DT-MREIT

    by W. C. Jeong, S. Z. K. Sajib, T. I. Oh, H. J. Kim, O. I. Kwon, E. J. Woo


  • Open Access

    Evaluation of three-dimensional anisotropic head model for mapping realistic electromagnetic fields of brain tissues

    by Woo Chul Jeong, Hun Wi, Saurav Z. K. Sajib, Tong In Oh, Hyung Joong Kim, Oh In Kwon, Eung Je Woo

    Electromagnetic fields provide fundamental data for the imaging of electrical tissue properties, such as conductivity and permittivity, in recent magnetic resonance (MR)-based tissue property mapping. The induced voltage, current density, and magnetic flux density caused by externally injected current are critical factors for determining the image quality of electrical tissue conductivity. As a useful tool to identify bio-electromagnetic phenomena, precise approaches are required to understand the exact responses inside the human body subject to an injected currents. In this study, we provide the numerical simulation results of electromagnetic field mapping of brain tissues using a MR-based conductivity imaging method. First, we implemented a realistic three-dimensional human anisotropic head model using high-resolution anatomical and diffusion tensor MR images. The voltage, current density, and magnetic flux density of brain tissues were imaged by injecting 1 mA of current through pairs of electrodes on the surface of our head model. The current density map of anisotropic brain tissues was calculated from the measured magnetic flux density based on the linear relationship between the water diffusion tensor and the electrical conductivity tensor. Comparing the current density to the previous isotropic model, the anisotropic model clearly showed the differences between the brain tissues. This originates from the enhanced signals by the inherent conductivity contrast as well as the actual tissue condition resulting from the injected currents.