Patrick Boyle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patrick Boyle has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Dan Jiang
Evelina Children's Health, London, UK
3 shared publications - Andrew Lotfallah
Worcestershire Royal Hospital, Worcestershire Acute Hospitals NHS Trust
2 shared publications David Selvadurai
St Georges Hospital NHS Trust, Blackshaw Rd, London, SW17 0QT, UK
2 shared publicationsDeborah Vickers
UCL Speech, Hearing and Phonetic Sciences Department, London, WC1N 1PF, UK
2 shared publications- Gemma Bale
Department of Engineering, University of Cambridge
2 shared publications - Jaime A. Undurraga
Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, DK-2800 Kgs. Lyngby, Denmark
2 shared publications
Latest Publications
- Open Access
- 23 November 2023
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 138 (7) , 710-731
The effect of photobiomodulation on tinnitus: a systematic review
Objective: To establish outcomes following photobiomodulation therapy for tinnitus in humans and animal studies.Methods: A systematic review and narrative synthesis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. The databases searched were: Medline, Embase, Cochrane Central Register of Controlled Trials (‘Central’), ClinicalTrials.gov and Web of Science including the Web of Science Core collection. There were no limits on language or year of publication.Results: The searches identified 194 abstracts and 61 full texts. Twenty-eight studies met the inclusion criteria, reporting outcomes in 1483 humans (26 studies) and 34 animals (2 studies). Photobiomodulation therapy parameters included 10 different wavelengths, and duration ranged from 9 seconds to 30 minutes per session. Follow up ranged from 7 days to 6 months.Conclusion: Tinnitus outcomes following photobiomodulation therapy are generally positive and superior to no photobiomodulation therapy; however, evidence of long-term therapeutic benefit is deficient. Photobiomodulation therapy enables concentrated, focused delivery of light therapy to the inner ear through a non-invasive manner, with minimal side effects.
- 23 November 2023
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 138 (7) , 710-731
Open AccessThe effect of photobiomodulation on tinnitus: a systematic review
Objective: To establish outcomes following photobiomodulation therapy for tinnitus in humans and animal studies.Methods: A systematic review and narrative synthesis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. The databases searched were: Medline, Embase, Cochrane Central Register of Controlled Trials (‘Central’), ClinicalTrials.gov and Web of Science including the Web of Science Core collection. There were no limits on language or year of publication.Results: The searches identified 194 abstracts and 61 full texts. Twenty-eight studies met the inclusion criteria, reporting outcomes in 1483 humans (26 studies) and 34 animals (2 studies). Photobiomodulation therapy parameters included 10 different wavelengths, and duration ranged from 9 seconds to 30 minutes per session. Follow up ranged from 7 days to 6 months.Conclusion: Tinnitus outcomes following photobiomodulation therapy are generally positive and superior to no photobiomodulation therapy; however, evidence of long-term therapeutic benefit is deficient. Photobiomodulation therapy enables concentrated, focused delivery of light therapy to the inner ear through a non-invasive manner, with minimal side effects.
- Open Access
- 26 October 2023
- Published by Wiley in Clinical Otolaryngology
- Vol. 49 (1) , 41-61
The effect of photobiomodulation on hearing loss: A systematic review
ObjectivesTo assess outcomes associated with photobiomodulation therapy (PBMT) for hearing loss in human and animal studies.DesignSystematic review and narrative synthesis in accordance with PRISMA guidelines.SettingData bases searched: MEDLINE, EMBASE, CENTRAL, ClinicalTrials.gov and Web of Science. No limits were placed on language or year of publication. Review conducted in accordance with the PRISMA 2020 statement.ParticipantsAll human and animal subjects treated with PBMT for hearing loss.Main outcome measuresPre- and post-PBMT audio metric outcomes.ResultsSearches identified 122 abstracts and 49 full text articles. Of these, 17 studies met the inclusion criteria, reporting outcomes in 327 animals (11 studies), 30 humans (1 study), and 40 animal specimens (5 studies). PBMT parameters included 6 different wavelengths: 908 nm (1 study), 810 nm (1 study), 532 & 635 nm (1 study), 830 nm (3 studies), 808 nm (11 studies). The duration ranged from 4 to 60 minutes in a session, and the follow-up ranged from 5-28 days. Outcomes improved significantly when wavelengths within the range of 800-830 nm were used, and with greater duration of PBMT exposure. Included studies predominantly consisted of non-randomized controlled trials (10 studies).ConclusionsHearing outcomes following PBMT appear to be superior to no PBMT for subjects with hearing loss, although higher level evidence is required to verify this. PBMT enables concentrated, focused delivery of light therapy to the inner ear through a non-invasive manner with minimal side effects. As a result of heterogeneity in reporting PBMT parameters and outcomes across the included studies, direct comparison is challenging.
- 26 October 2023
- Published by Wiley in Clinical Otolaryngology
- Vol. 49 (1) , 41-61
Open AccessThe effect of photobiomodulation on hearing loss: A systematic review
ObjectivesTo assess outcomes associated with photobiomodulation therapy (PBMT) for hearing loss in human and animal studies.DesignSystematic review and narrative synthesis in accordance with PRISMA guidelines.SettingData bases searched: MEDLINE, EMBASE, CENTRAL, ClinicalTrials.gov and Web of Science. No limits were placed on language or year of publication. Review conducted in accordance with the PRISMA 2020 statement.ParticipantsAll human and animal subjects treated with PBMT for hearing loss.Main outcome measuresPre- and post-PBMT audio metric outcomes.ResultsSearches identified 122 abstracts and 49 full text articles. Of these, 17 studies met the inclusion criteria, reporting outcomes in 327 animals (11 studies), 30 humans (1 study), and 40 animal specimens (5 studies). PBMT parameters included 6 different wavelengths: 908 nm (1 study), 810 nm (1 study), 532 & 635 nm (1 study), 830 nm (3 studies), 808 nm (11 studies). The duration ranged from 4 to 60 minutes in a session, and the follow-up ranged from 5-28 days. Outcomes improved significantly when wavelengths within the range of 800-830 nm were used, and with greater duration of PBMT exposure. Included studies predominantly consisted of non-randomized controlled trials (10 studies).ConclusionsHearing outcomes following PBMT appear to be superior to no PBMT for subjects with hearing loss, although higher level evidence is required to verify this. PBMT enables concentrated, focused delivery of light therapy to the inner ear through a non-invasive manner with minimal side effects. As a result of heterogeneity in reporting PBMT parameters and outcomes across the included studies, direct comparison is challenging.
- 1 September 2018
- Published by Elsevier in Hearing Research
- Vol. 367, 74-87
Development of electrophysiological and behavioural measures of electrode discrimination in adult cochlear implant users
- 1 September 2018
- Published by Elsevier in Hearing Research
- Vol. 367, 74-87
Development of electrophysiological and behavioural measures of electrode discrimination in adult cochlear implant users
- 1 October 2017
- Published by Elsevier in Hearing Research
- Vol. 354, 86-101
Objective assessment of electrode discrimination with the auditory change complex in adult cochlear implant users
- 1 October 2017
- Published by Elsevier in Hearing Research
- Vol. 354, 86-101
Objective assessment of electrode discrimination with the auditory change complex in adult cochlear implant users