Mark C. van Turnhout
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mark C. van Turnhout has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Johan L. van Leeuwen
Wageningen University Experimental Zoology Group, Department of Animal Sciences De Elst 1, 6708 WD Wageningen
5 shared publications - Carlijn V. C. Bouten
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
4 shared publications Sander Kranenbarg
Wageningen University
4 shared publications- Nicholas A. Kurniawan
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
3 shared publications Cees W. J. Oomens
Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publicationsCorrinus C. van Donkelaar
Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 31 January 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 213, 439-451
Dynamic and static strain levels differentially affect the enzymatic degradation of collagen fibres
- 31 January 2026
- Published by Elsevier in Acta Biomaterialia
- Vol. 213, 439-451
Open AccessDynamic and static strain levels differentially affect the enzymatic degradation of collagen fibres
- Open Access
- 8 January 2025
- Published by Oxford University Press (OUP) in Integrative Biology
- Vol. 17
Equibiaxial and uniaxial cyclic strain similarly affect Notch signaling and vascular smooth muscle cell phenotype in 2D
Vascular smooth muscle cells (VSMCs) play a crucial role in vascular growth and remodeling by adapting their phenotype in response to biomechanical cues. The Notch signaling pathway, known for its sensitivity to mechanical forces, is a regulator of strain-induced phenotypic plasticity of VSMCs. However, the impact of the intricate mechanical environment within the vessel wall on Notch signaling and VSMCs is not completely elucidated. In this study, we investigated the influence of strain anisotropy, which is important for understanding (patho)physiological mechanical conditions, on mechanosensitive Notch signaling and subsequent changes in VSMC phenotype. Using varying amplitudes of cyclic strain in the physiological range, we examined the effects of equibiaxial and uniaxial strain on Notch signaling and phenotypic transitions in synthetic and contractile VSMCs. Additionally, we compared cell responses between equibiaxial and uniaxial loading conditions by analyzing three different deformation characteristics to determine the primary strain measure governing Notch signaling and VSMC phenotype. Our findings reveal that both cyclic equibiaxial and uniaxial strain downregulate Notch signaling and contractile characteristics of VSMCs. Notably, these reductions are most similar for both loading conditions when the maximum principal strain values were compared. Overall, our results suggest that VSMCs respond in a comparable manner to equibiaxial and uniaxial strain, indicating that strain anisotropy may not significantly influence Notch signaling or phenotypic switching of VSMCs. Insight Box: Vascular smooth muscle cells (VSMCs) adapt their phenotype during vascular growth and remodeling in response to mechanical cues. The Notch signaling pathway, sensitive to mechanical stimuli, regulates this phenotypic plasticity. However, the effect of strain anisotropy, which is important for understanding (patho)physiological mechanical conditions, on Notch signaling and subsequent changes in VSMC phenotype is not clear. Understanding this relationship is crucial to determine how VSMC phenotype, contributing to vascular growth and remodeling, is regulated in physiological and pathological hemodynamic environments. Here, we showed that both equibiaxial and uniaxial strain downregulate Notch signaling components and the contractile properties of VSMCs. Our findings further highlighted the maximum principal strain as the dominant mechanical parameter influencing Notch signaling and VSMC phenotypic changes.
- 8 January 2025
- Published by Oxford University Press (OUP) in Integrative Biology
- Vol. 17
Open AccessEquibiaxial and uniaxial cyclic strain similarly affect Notch signaling and vascular smooth muscle cell phenotype in 2D
Vascular smooth muscle cells (VSMCs) play a crucial role in vascular growth and remodeling by adapting their phenotype in response to biomechanical cues. The Notch signaling pathway, known for its sensitivity to mechanical forces, is a regulator of strain-induced phenotypic plasticity of VSMCs. However, the impact of the intricate mechanical environment within the vessel wall on Notch signaling and VSMCs is not completely elucidated. In this study, we investigated the influence of strain anisotropy, which is important for understanding (patho)physiological mechanical conditions, on mechanosensitive Notch signaling and subsequent changes in VSMC phenotype. Using varying amplitudes of cyclic strain in the physiological range, we examined the effects of equibiaxial and uniaxial strain on Notch signaling and phenotypic transitions in synthetic and contractile VSMCs. Additionally, we compared cell responses between equibiaxial and uniaxial loading conditions by analyzing three different deformation characteristics to determine the primary strain measure governing Notch signaling and VSMC phenotype. Our findings reveal that both cyclic equibiaxial and uniaxial strain downregulate Notch signaling and contractile characteristics of VSMCs. Notably, these reductions are most similar for both loading conditions when the maximum principal strain values were compared. Overall, our results suggest that VSMCs respond in a comparable manner to equibiaxial and uniaxial strain, indicating that strain anisotropy may not significantly influence Notch signaling or phenotypic switching of VSMCs. Insight Box: Vascular smooth muscle cells (VSMCs) adapt their phenotype during vascular growth and remodeling in response to mechanical cues. The Notch signaling pathway, sensitive to mechanical stimuli, regulates this phenotypic plasticity. However, the effect of strain anisotropy, which is important for understanding (patho)physiological mechanical conditions, on Notch signaling and subsequent changes in VSMC phenotype is not clear. Understanding this relationship is crucial to determine how VSMC phenotype, contributing to vascular growth and remodeling, is regulated in physiological and pathological hemodynamic environments. Here, we showed that both equibiaxial and uniaxial strain downregulate Notch signaling components and the contractile properties of VSMCs. Our findings further highlighted the maximum principal strain as the dominant mechanical parameter influencing Notch signaling and VSMC phenotypic changes.
- Open Access
- 23 September 2023
- Published by Wiley in Advanced Science
- Vol. 10 (31) , e2303136
Shape‐Morphing Photoresponsive Hydrogels Reveal Dynamic Topographical Conditioning of Fibroblasts
The extracellular environment defines a physical boundary condition with which cells interact. However, to date, cell response to geometrical environmental cues is largely studied in static settings, which fails to capture the spatiotemporally varying cues cells receive in native tissues. Here, a photoresponsive spiropyran‐based hydrogel is presented as a dynamic, cell‐compatible, and reconfigurable substrate. Local stimulation with blue light (455 nm) alters hydrogel swelling, resulting in on‐demand reversible micrometer‐scale changes in surface topography within 15 min, allowing investigation into cell response to controlled geometry actuations. At short term (1 h after actuation), fibroblasts respond to multiple rounds of recurring topographical changes by reorganizing their nucleus and focal adhesions (FA). FAs form primarily at the dynamic regions of the hydrogel; however, this propensity is abolished when the topography is reconfigured from grooves to pits, demonstrating that topographical changes dynamically condition fibroblasts. Further, this dynamic conditioning is found to be associated with long‐term (72 h) maintenance of focal adhesions and epigenetic modifications. Overall, this study offers a new approach to dissect the dynamic interplay between cells and their microenvironment and shines a new light on the cell's ability to adapt to topographical changes through FA‐based mechanotransduction.
- 23 September 2023
- Published by Wiley in Advanced Science
- Vol. 10 (31) , e2303136
Open AccessShape‐Morphing Photoresponsive Hydrogels Reveal Dynamic Topographical Conditioning of Fibroblasts
The extracellular environment defines a physical boundary condition with which cells interact. However, to date, cell response to geometrical environmental cues is largely studied in static settings, which fails to capture the spatiotemporally varying cues cells receive in native tissues. Here, a photoresponsive spiropyran‐based hydrogel is presented as a dynamic, cell‐compatible, and reconfigurable substrate. Local stimulation with blue light (455 nm) alters hydrogel swelling, resulting in on‐demand reversible micrometer‐scale changes in surface topography within 15 min, allowing investigation into cell response to controlled geometry actuations. At short term (1 h after actuation), fibroblasts respond to multiple rounds of recurring topographical changes by reorganizing their nucleus and focal adhesions (FA). FAs form primarily at the dynamic regions of the hydrogel; however, this propensity is abolished when the topography is reconfigured from grooves to pits, demonstrating that topographical changes dynamically condition fibroblasts. Further, this dynamic conditioning is found to be associated with long‐term (72 h) maintenance of focal adhesions and epigenetic modifications. Overall, this study offers a new approach to dissect the dynamic interplay between cells and their microenvironment and shines a new light on the cell's ability to adapt to topographical changes through FA‐based mechanotransduction.
- Open Access
Single cell profiling reveals functional heterogeneity and serial killing in human peripheral and ex vivo-generated CD34+ progenitor derived Natural Killer cells
Increasing evidence suggest that Natural killer (NK) cells are composed of distinct functional subsets. This multi-functional role displayed by NK cells have made them an attractive choice for anti-cancer immunotherapy. A functional NK cell repertoire is generated through cellular education, resulting in heterogeneous NK cell population with distinct capabilities to respond to different stimuli. The application of a high-throughput droplet-based microfluidic platform allows monitoring of NK cell-target cell interactions at single-cell level and in real-time. Through fluorescence-based screening of around 80,000 droplets, with different Effector:Target ratios, a fully automated image analysis allows for the assessment of individual killing events in each droplet over time. We observed a variable response of single NK cells towards different target cells and identified a distinct population of NK cells capable of inducing multiple target lysis, coined as serial killers. To meet the increasing clinical demand for NK cells several sources, such as umbilical cord blood (UCB), have successfully been explored. By assessing the cytotoxic dynamics, we showed that single UCB-derived CD34+ hematopoietic progenitor (HPC)-NK cells display superior anti-tumor cytotoxicity. Additionally, with an integrated analysis of cytotoxicity and cytokine secretion we showed that target cell interactions augmented cytotoxic as well as secretory behavior of NK cells. By providing an in-depth assessment over NK cell functions, this study provides crucial information on diversity and functional characteristics of peripheral blood NK cells and ex vivo -generated HPC-NK cells to develop and improve of NK cell-based cancer immunotherapy.
Open AccessSingle cell profiling reveals functional heterogeneity and serial killing in human peripheral and ex vivo-generated CD34+ progenitor derived Natural Killer cells
Increasing evidence suggest that Natural killer (NK) cells are composed of distinct functional subsets. This multi-functional role displayed by NK cells have made them an attractive choice for anti-cancer immunotherapy. A functional NK cell repertoire is generated through cellular education, resulting in heterogeneous NK cell population with distinct capabilities to respond to different stimuli. The application of a high-throughput droplet-based microfluidic platform allows monitoring of NK cell-target cell interactions at single-cell level and in real-time. Through fluorescence-based screening of around 80,000 droplets, with different Effector:Target ratios, a fully automated image analysis allows for the assessment of individual killing events in each droplet over time. We observed a variable response of single NK cells towards different target cells and identified a distinct population of NK cells capable of inducing multiple target lysis, coined as serial killers. To meet the increasing clinical demand for NK cells several sources, such as umbilical cord blood (UCB), have successfully been explored. By assessing the cytotoxic dynamics, we showed that single UCB-derived CD34+ hematopoietic progenitor (HPC)-NK cells display superior anti-tumor cytotoxicity. Additionally, with an integrated analysis of cytotoxicity and cytokine secretion we showed that target cell interactions augmented cytotoxic as well as secretory behavior of NK cells. By providing an in-depth assessment over NK cell functions, this study provides crucial information on diversity and functional characteristics of peripheral blood NK cells and ex vivo -generated HPC-NK cells to develop and improve of NK cell-based cancer immunotherapy.
- Open Access
- 18 January 2021
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 9 (6) , 2209-2220
Biomaterial screening of protein coatings and peptide additives: towards a simple synthetic mimic of a complex natural coating for a bio-artificial kidney
Bio-artificial kidneys require conveniently synthesized membranes providing signals that regulate renal epithelial cell function. Therefore, we aimed to find synthetic analogues for natural extracellular matrix (ECM) protein coatings traditionally used for epithelial cell culturing. Two biomaterial libraries, based on natural ECM-coatings and on synthetic supramolecular small molecule additives, were developed. The base material consisted of a bisurea (BU) containing polymer, providing supramolecular BU-additives to be incorporated via specific hydrogen bonding interactions. This system allows for a modular approach and therefore easy fractional factorial based screening. A natural coating on the BU-polymer material with basement membrane proteins, laminin and collagen IV, combined with catechols was shown to induce renal epithelial monolayer formation. Modification of the BU-polymer material with synthetic BU-modified ECM peptide additives did not result in monolayer formation. Unexpectedly, simple BU-catechol additives induced monolayer formation and presented similar levels of epithelial markers and apical transporter function as on the laminin, collagen IV and catechol natural coating. Importantly, when this BU-polymer material was processed into fibrous e-spun membranes the natural coating and the BU-catechol additive were shown to perfectly function. This study clearly indicates that complex natural ECM-coatings can be replaced by simple synthetic additives, and displays the potency of material libraries based on design of experiments in combination with modular, supramolecular chemistry.
- 18 January 2021
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 9 (6) , 2209-2220
Open AccessBiomaterial screening of protein coatings and peptide additives: towards a simple synthetic mimic of a complex natural coating for a bio-artificial kidney
Bio-artificial kidneys require conveniently synthesized membranes providing signals that regulate renal epithelial cell function. Therefore, we aimed to find synthetic analogues for natural extracellular matrix (ECM) protein coatings traditionally used for epithelial cell culturing. Two biomaterial libraries, based on natural ECM-coatings and on synthetic supramolecular small molecule additives, were developed. The base material consisted of a bisurea (BU) containing polymer, providing supramolecular BU-additives to be incorporated via specific hydrogen bonding interactions. This system allows for a modular approach and therefore easy fractional factorial based screening. A natural coating on the BU-polymer material with basement membrane proteins, laminin and collagen IV, combined with catechols was shown to induce renal epithelial monolayer formation. Modification of the BU-polymer material with synthetic BU-modified ECM peptide additives did not result in monolayer formation. Unexpectedly, simple BU-catechol additives induced monolayer formation and presented similar levels of epithelial markers and apical transporter function as on the laminin, collagen IV and catechol natural coating. Importantly, when this BU-polymer material was processed into fibrous e-spun membranes the natural coating and the BU-catechol additive were shown to perfectly function. This study clearly indicates that complex natural ECM-coatings can be replaced by simple synthetic additives, and displays the potency of material libraries based on design of experiments in combination with modular, supramolecular chemistry.
- Open Access
- 1 August 2020
- Published by Elsevier in Clinical Biomechanics
- Vol. 78, 105094
Risk factors for developing heel ulcers for bedridden patients: A finite element study
- 1 August 2020
- Published by Elsevier in Clinical Biomechanics
- Vol. 78, 105094
Open AccessRisk factors for developing heel ulcers for bedridden patients: A finite element study
- Open Access
- 1 May 2020
- Published by Elsevier in Cell Reports Physical Science
- Vol. 1 (5) , 100055
Cellular Contact Guidance Emerges from Gap Avoidance
- 1 May 2020
- Published by Elsevier in Cell Reports Physical Science
- Vol. 1 (5) , 100055
Open AccessCellular Contact Guidance Emerges from Gap Avoidance
- Open Access
- 25 March 2019
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 15 (16) , 3353-3361
Image-based analysis of uniaxial ring test for mechanical characterization of soft materials and biological tissues
We propose a simple image-based analysis approach to accurately estimate the mechanical properties of ring-shaped materials.
- 25 March 2019
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 15 (16) , 3353-3361
Open AccessImage-based analysis of uniaxial ring test for mechanical characterization of soft materials and biological tissues
We propose a simple image-based analysis approach to accurately estimate the mechanical properties of ring-shaped materials.
- Open Access
- 26 October 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 21 (14) , 760-769
MRI based 3D finite element modelling to investigate deep tissue injury
Pressure ulcers occur due to sustained mechanical loading. Deep tissue injury is a severe type of pressure ulcer, which is believed to originate in subcutaneous tissues adjacent to bony prominences. In previous experimental-numerical studies the relationship between internal tissue state and damage development was investigated using a 2D analysis. However, recent studies suggest that a local analysis is not sufficient. In the present study we developed a method to create animal-specific 3D finite element models of an indentation test on the tibialis anterior muscle of rats based on MRI data. A detailed description on how the animal specific models are created is given. Furthermore, two indenter geometries are compared and the influence of errors in determining the indenter orientation on the resulting internal strain distribution in a defined volume of tissue was investigated. We conclude that with a spherically-shaped indenter errors in estimating the indenter orientation do not unduly influence the results of the simulation.
- 26 October 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 21 (14) , 760-769
Open AccessMRI based 3D finite element modelling to investigate deep tissue injury
Pressure ulcers occur due to sustained mechanical loading. Deep tissue injury is a severe type of pressure ulcer, which is believed to originate in subcutaneous tissues adjacent to bony prominences. In previous experimental-numerical studies the relationship between internal tissue state and damage development was investigated using a 2D analysis. However, recent studies suggest that a local analysis is not sufficient. In the present study we developed a method to create animal-specific 3D finite element models of an indentation test on the tibialis anterior muscle of rats based on MRI data. A detailed description on how the animal specific models are created is given. Furthermore, two indenter geometries are compared and the influence of errors in determining the indenter orientation on the resulting internal strain distribution in a defined volume of tissue was investigated. We conclude that with a spherically-shaped indenter errors in estimating the indenter orientation do not unduly influence the results of the simulation.
- 1 October 2015
- Published by Elsevier in Journal of Molecular and Cellular Cardiology
- Vol. 87, 79-91
Behavior of CMPCs in unidirectional constrained and stress-free 3D hydrogels
- 1 October 2015
- Published by Elsevier in Journal of Molecular and Cellular Cardiology
- Vol. 87, 79-91
Behavior of CMPCs in unidirectional constrained and stress-free 3D hydrogels