Varun K. Gajendran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Varun K. Gajendran has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Brett Peterson
2 shared publicationsRobert M. Szabo
2 shared publicationsAnthony Behn
1 shared publicationBrad J. Yoo
1 shared publication- Catherine M. Curtin
Department of Surgery – Plastic and Reconstructive Surgery, Stanford University School of Medicine, Stanford, CA
1 shared publication - Colin Yi-Loong Woon
Section of Plastic Surgery, VA Palo Alto Health Care System and the Division of Plastic Surgery, Stanford University Medical Center, Stanford, California
1 shared publication
Latest Publications
- 1 July 2014
- Published by SLACK, Inc. in Orthopedics
- Vol. 37 (7) , e657-e660
Multiple Collagenase Injections Are Safe for Treatment of Dupuytren’s Contractures
The authors report the case of a 65-year-old, right-hand-dominant man who had severe Dupuytren’s disease with multiple cords and flexion contractures of the metacarpophalangeal and proximal interphalangeal joints of both hands and underwent repeated collagenase injections for treatment. Collagenase has been shown to be safe and effective in the treatment of Dupuytren’s contractures when administered as a single dose, but the results of multiple injections over a prolonged period are unknown. Antibodies to collagenase develop in all patients after several treatments, raising concerns about safety and efficacy as a result of sensitization from repeated exposures. The antibodies generated as a result of repeated exposure to collagenase could theoretically render it less effective with time and could also lead to immune reactions as severe as anaphylaxis. The authors present the case of a single patient who experienced continued correction of his contractures with only minor and self-limited adverse reactions after administration of 12 collagenase doses through 15 injections during a 4-year period. Over time, the injections continued to be effective at correcting metacarpophalangeal joint contractures, but less effective at correcting proximal interphalangeal joint contractures. The patient did eventually require a fasciectomy, but the safety and modest success of the repeated collagenase injections shows promise for a less invasive treatment with a better risk profile than open fasciectomy. Although further studies are needed, repeated administration of collagenase appears to be safe and modestly effective for severe Dupuytren’s contractures, although a fasciectomy may ultimately be required in the most severe cases.
- 1 July 2014
- Published by SLACK, Inc. in Orthopedics
- Vol. 37 (7) , e657-e660
Multiple Collagenase Injections Are Safe for Treatment of Dupuytren’s Contractures
The authors report the case of a 65-year-old, right-hand-dominant man who had severe Dupuytren’s disease with multiple cords and flexion contractures of the metacarpophalangeal and proximal interphalangeal joints of both hands and underwent repeated collagenase injections for treatment. Collagenase has been shown to be safe and effective in the treatment of Dupuytren’s contractures when administered as a single dose, but the results of multiple injections over a prolonged period are unknown. Antibodies to collagenase develop in all patients after several treatments, raising concerns about safety and efficacy as a result of sensitization from repeated exposures. The antibodies generated as a result of repeated exposure to collagenase could theoretically render it less effective with time and could also lead to immune reactions as severe as anaphylaxis. The authors present the case of a single patient who experienced continued correction of his contractures with only minor and self-limited adverse reactions after administration of 12 collagenase doses through 15 injections during a 4-year period. Over time, the injections continued to be effective at correcting metacarpophalangeal joint contractures, but less effective at correcting proximal interphalangeal joint contractures. The patient did eventually require a fasciectomy, but the safety and modest success of the repeated collagenase injections shows promise for a less invasive treatment with a better risk profile than open fasciectomy. Although further studies are needed, repeated administration of collagenase appears to be safe and modestly effective for severe Dupuytren’s contractures, although a fasciectomy may ultimately be required in the most severe cases.
- 1 August 2012
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 37 (8) , 1639-1645
The Effect of Suture Coated With Mesenchymal Stem Cells and Bioactive Substrate on Tendon Repair Strength in a Rat Model
- 1 August 2012
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 37 (8) , 1639-1645
The Effect of Suture Coated With Mesenchymal Stem Cells and Bioactive Substrate on Tendon Repair Strength in a Rat Model
- 1 April 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (4) , 1204-1212
Surgical Technique: Methods for Removing a Compress® Compliant Prestress Implant
The Compress® device uses a unique design using compressive forces to achieve bone ingrowth on the prosthesis. Because of its design, removal of this device may require special techniques to preserve host bone. Techniques needed include removal of a small amount of bone to relieve compressive forces, use of a pin extractor and/or Kirschner wires for removal of transfixation pins, and creation of a cortical window in the diaphysis to gain access to bone preventing removal of the anchor plug. We retrospectively reviewed the records of 63 patients receiving a Compress® device from 1996 to 2011 and identified 11 patients who underwent subsequent prosthesis removal. The minimum followup was 1 month (average, 20 months; range, 1–80 months). The most common reason for removal was infection (eight patients) and the most common underlying diagnosis was osteosarcoma (five patients). Three patients underwent above-knee amputation, whereas the others (eight patients) had further limb salvage procedures at the time of prosthesis removal. Five patients had additional unplanned surgeries after explantation. Irrigation and débridement of the surgical wound was the most common unplanned procedure followed by latissimus free flap and hip prosthesis dislocation. At the time of followup, all patients were ambulating on either salvaged extremities or prostheses. Although removal of the Compress® device presents unique challenges, we describe techniques to address those challenges.
- 1 April 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (4) , 1204-1212
Surgical Technique: Methods for Removing a Compress® Compliant Prestress Implant
The Compress® device uses a unique design using compressive forces to achieve bone ingrowth on the prosthesis. Because of its design, removal of this device may require special techniques to preserve host bone. Techniques needed include removal of a small amount of bone to relieve compressive forces, use of a pin extractor and/or Kirschner wires for removal of transfixation pins, and creation of a cortical window in the diaphysis to gain access to bone preventing removal of the anchor plug. We retrospectively reviewed the records of 63 patients receiving a Compress® device from 1996 to 2011 and identified 11 patients who underwent subsequent prosthesis removal. The minimum followup was 1 month (average, 20 months; range, 1–80 months). The most common reason for removal was infection (eight patients) and the most common underlying diagnosis was osteosarcoma (five patients). Three patients underwent above-knee amputation, whereas the others (eight patients) had further limb salvage procedures at the time of prosthesis removal. Five patients had additional unplanned surgeries after explantation. Irrigation and débridement of the surgical wound was the most common unplanned procedure followed by latissimus free flap and hip prosthesis dislocation. At the time of followup, all patients were ambulating on either salvaged extremities or prostheses. Although removal of the Compress® device presents unique challenges, we describe techniques to address those challenges.
Is the Fibronectin‐Aggrecan Complex Present in Cervical Disk Disease?
Objective: To investigate the presence of inflammatory cytokines and the fibronectin‐aggrecan complex (FAC) in persons undergoing surgical treatment for cervical radiculopathy caused by disk herniation.Design: Single‐center, prospective, consecutive case series.Setting: A single large academic institution.Patients: A total of 11 patients with radiculopathic pain and magnetic resonance imaging findings positive for disk herniation elected to undergo single‐level cervical diskectomy.Methods or Interventions: Lavage was performed by needle injection and aspiration upon entering the disk space for fluoroscopic localization before diskectomy.Main Outcome Measurements: The lavage fluid was assayed for pH and the FAC, as well as for the cytokines interleukin‐6 (IL‐6), interferon‐γ, monocyte chemotactic protein (MCP), and macrophage inhibitory protein‐1β.Results: The subjects were 7 women and 4 men with a mean age of 50.6 years (SE 9.7; range, 36‐70 years). The mean concentrations (SE; range) in picograms per milliliter were 7.9 (4.4; 0‐44) for IL‐6, 25.3 (15.5; 0‐159) for interferon‐γ, 16.1 (11.9; 0‐121) for MCP, and 6.1 (2.8; 0‐29) for macrophage inhibitory protein‐1β. The optical density of the FAC at 450 nm was 0.151 (0.036; 0.1‐0.32), and the pH was 6.68 (0.1; 6.10‐7.15). Statistically significant correlations were found between MCP and FAC (P = .036) and between FAC and pH (P = .008).Conclusions: Biochemical analysis of injured cervical intervertebral disks reveals the presence of inflammatory markers such as MCP, fragments of structural matrix proteins such as FAC, and a correlation with pH. Further evaluation of the FAC as a potential diagnostic biomarker or therapeutic target is warranted in the cervical spine.
Is the Fibronectin‐Aggrecan Complex Present in Cervical Disk Disease?
Objective: To investigate the presence of inflammatory cytokines and the fibronectin‐aggrecan complex (FAC) in persons undergoing surgical treatment for cervical radiculopathy caused by disk herniation.Design: Single‐center, prospective, consecutive case series.Setting: A single large academic institution.Patients: A total of 11 patients with radiculopathic pain and magnetic resonance imaging findings positive for disk herniation elected to undergo single‐level cervical diskectomy.Methods or Interventions: Lavage was performed by needle injection and aspiration upon entering the disk space for fluoroscopic localization before diskectomy.Main Outcome Measurements: The lavage fluid was assayed for pH and the FAC, as well as for the cytokines interleukin‐6 (IL‐6), interferon‐γ, monocyte chemotactic protein (MCP), and macrophage inhibitory protein‐1β.Results: The subjects were 7 women and 4 men with a mean age of 50.6 years (SE 9.7; range, 36‐70 years). The mean concentrations (SE; range) in picograms per milliliter were 7.9 (4.4; 0‐44) for IL‐6, 25.3 (15.5; 0‐159) for interferon‐γ, 16.1 (11.9; 0‐121) for MCP, and 6.1 (2.8; 0‐29) for macrophage inhibitory protein‐1β. The optical density of the FAC at 450 nm was 0.151 (0.036; 0.1‐0.32), and the pH was 6.68 (0.1; 6.10‐7.15). Statistically significant correlations were found between MCP and FAC (P = .036) and between FAC and pH (P = .008).Conclusions: Biochemical analysis of injured cervical intervertebral disks reveals the presence of inflammatory markers such as MCP, fragments of structural matrix proteins such as FAC, and a correlation with pH. Further evaluation of the FAC as a potential diagnostic biomarker or therapeutic target is warranted in the cervical spine.
- 1 December 2009
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 34 (10) , 1851-1858
Biomechanical Comparison of Double-Row Locking Plates Versus Single- and Double-Row Non-Locking Plates in a Comminuted Metacarpal Fracture Model
- 1 December 2009
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 34 (10) , 1851-1858
Biomechanical Comparison of Double-Row Locking Plates Versus Single- and Double-Row Non-Locking Plates in a Comminuted Metacarpal Fracture Model
- Open Access
- 1 January 2008
- Published by Elsevier in Radiology Case Reports
- Vol. 3 (3) , 208
Unusual Variant of the Nutcracker Fracture of the Calcaneus and Tarsal Navicular
- 1 January 2008
- Published by Elsevier in Radiology Case Reports
- Vol. 3 (3) , 208
Open AccessUnusual Variant of the Nutcracker Fracture of the Calcaneus and Tarsal Navicular
- 1 November 2007
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 32 (9) , 1323-1333
Long-Term Outcomes of Dorsal Intercarpal Ligament Capsulodesis for Chronic Scapholunate Dissociation
- 1 November 2007
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 32 (9) , 1323-1333
Long-Term Outcomes of Dorsal Intercarpal Ligament Capsulodesis for Chronic Scapholunate Dissociation
- 10 August 2007
- Published by SAGE Publications in HAND
- Vol. 3 (1) , 61-68
Corrective Osteotomy for Deformity of the Distal Radius Using a Volar Locking Plate
Dorsally angulated malunions of the distal radius have historically been corrected with an opening wedge osteotomy fixed with a dorsal plate. Volar locking plates may facilitate a less morbid approach to corrective osteotomies of the wrist. Eight consecutive patients with an average age of 40 years (range, 15–52 years) underwent correction of a distal radius deformity through a volar approach. Clinical follow-up averaged 17.4 months (range, 7–41 months). Preoperative radiographs revealed an average of 24° of dorsal tilt in patients with dorsal deformity. Postoperatively, their average measurement was <3° of volar tilt. Patients were initially ulnar-positive with an average of 4 mm ulnar-positive variance (range, 2–7 mm). This corrected to less than 1 mm postoperatively. Postoperative disabilities of the arm, shoulder, and hand (DASH), SF-12, and Mayo Wrist scores averaged 10.8, 40.5, and 82.5, respectively. There were no nonunions, and no plates required removal. Distal radius deformity can be effectively addressed through a volar approach with the use of a locking plate.
- 10 August 2007
- Published by SAGE Publications in HAND
- Vol. 3 (1) , 61-68
Corrective Osteotomy for Deformity of the Distal Radius Using a Volar Locking Plate
Dorsally angulated malunions of the distal radius have historically been corrected with an opening wedge osteotomy fixed with a dorsal plate. Volar locking plates may facilitate a less morbid approach to corrective osteotomies of the wrist. Eight consecutive patients with an average age of 40 years (range, 15–52 years) underwent correction of a distal radius deformity through a volar approach. Clinical follow-up averaged 17.4 months (range, 7–41 months). Preoperative radiographs revealed an average of 24° of dorsal tilt in patients with dorsal deformity. Postoperatively, their average measurement was <3° of volar tilt. Patients were initially ulnar-positive with an average of 4 mm ulnar-positive variance (range, 2–7 mm). This corrected to less than 1 mm postoperatively. Postoperative disabilities of the arm, shoulder, and hand (DASH), SF-12, and Mayo Wrist scores averaged 10.8, 40.5, and 82.5, respectively. There were no nonunions, and no plates required removal. Distal radius deformity can be effectively addressed through a volar approach with the use of a locking plate.