ASAnna Sala-Puigdollers

Anna Sala-Puigdollers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anna Sala-Puigdollers has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pharmacoproteomics in the development of personalised medicine in Age-related Macular Degeneration (PHARPRO-AMD) study protocol

    by Antonio Cañizo-Outeiriño, Diana Carolina Castro-Fernández, Luis Arias-Barquet, María Isabel Fernández-Rodríguez, Nuria Olivier-Pascual, Ignacio Ortea, Salvador Pastor-Iodate, Enrique Rodríguez-De la Rúa-Franch, José M Ruiz-Moreno, Óscar Ruiz-Moreno, et al.

    Introduction: Age-related macular degeneration (AMD) is the leading cause of irreversible vision loss among people over 55 years of age globally, being neovascular AMD (nAMD) its most aggressive form. Its treatment consists of the use of drugs that block vascular endothelial growth factor (anti-VEGF). Proteomics may allow the identification of differentially expressed proteins between responders and non-responders to each anti-VEGF drug. Thus, the objective of Pharmacoproteomics in the development of personalised medicine in Age-related Macular Degeneration (PHARPRO-AMD) is to find new proteomic biomarkers, predictive of response to antiangiogenic treatment in patients with nAMD. Methods and analysis: PHARPRO-AMD is a nationwide, multicentre, prospective, observational study. Treatment-naïve patients with nAMD starting anti-VEGF therapy will be enrolled and followed up for 2 years. During this period, clinical variables will be gathered to classify treatment response. In addition, blood, tear and vitreous and aqueous humour samples will be collected and will undergo a ZenoSWATH proteomic analysis. Relevant biomarkers identified and response classification will be used to perform a multivariate logistic regression and construct receiver operating characteristic curves. Results: The study is expected to identify a panel of proteomic biomarkers predictive of anti-VEGF treatment response. Integrating data from invasive and non-invasive biological samples may enhance clinical applicability. Once validated, these biomarkers could support the design of future clinical trials on biomarker-guided therapies, helping to optimise treatment regimens and improve visual outcomes. Conclusions: The PHARPRO-AMD study aims to provide proof-of-concept for biomarker-guided anti-VEGF therapy in nAMD, potentially improving vision outcomes. A notable limitation is the exclusion of patients with visual acuity above 73 Early Treatment of Diabetic Retinopathy Study letters, a criterion chosen to reduce potential ceiling effects and improve response assessment accuracy. Ethics and dissemination: Approved by the Galician Network of Ethics Committees, with nationwide validity. Anonymised data will be deposited in open-access repositories and published in peer-reviewed journals. Trial registration number: Spanish Clinical Studies Registry (REec) (0033-2024-OBS).


  • Open Access

    Optical Coherence Tomography Angiography in Type 1 Diabetes Mellitus—Report 2: Diabetic Kidney Disease

    by Aníbal Alé-Chilet, Carolina Bernal-Morales, Marina Barraso, Teresa Hernández, Cristian Oliva, Irene Vinagre, Emilio Ortega, Marc Figueras-Roca, Anna Sala-Puigdollers, Cristina Esquinas, et al.

    The purpose of this study is to investigate potential associations between optical coherence tomography angiography (OCTA) parameters and diabetic kidney disease (DKD) categories in type 1 diabetes mellitus (T1DM) patients and controls. A complete ocular and systemic examination, including OCTA imaging tests and bloods, was performed. OCTA parameters included vessel density (VD), perfusion density (PD), foveal avascular zone area (FAZa), perimeter (FAZp) and circularity (FAZc) in the superficial vascular plexus, and DKD categories were defined according to glomerular filtration rate (GFR), albumin-creatinine ratio (ACR) and KDIGO prognosis risk classifications. A total of 425 individuals (1 eye/1 patient) were included. Reduced VD and FAZc were associated with greater categories of GFR (p = 0.002, p = 0.04), ACR (p = 0.003, p = 0.005) and KDIGO risk prognosis classifications (p = 0.002, p = 0.005). FAZc was significantly reduced in greater KDIGO prognosis risk categories (low risk vs. moderate risk, 0.65 ± 0.09 vs. 0.60 ± 0.07, p < 0.05). VD and FAZc presented the best diagnostic performance in ROCs. In conclusion, OCTA parameters, such as VD and FAZc, are able to detect different GFR, ACR, and KDIGO categories in T1DM patients and controls in a non-invasive, objective quantitative way. FAZc is able to discriminate within T1DM patients those with greater DKD categories and greater risk of DKD progression.


  • Open Access

    Optical Coherence Tomography Angiography in Type 1 Diabetes Mellitus. Report 4: Glycated Haemoglobin

    by Carolina Bernal-Morales, Aníbal Alé-Chilet, Ruben Martín-Pinardel, Marina Barraso, Teresa Hernández, Cristian Oliva, Irene Vinagre, Emilio Ortega, Marc Figueras-Roca, Anna Sala-Puigdollers, et al.

    The purpose of this study was to evaluate specifically the relationship between glycated haemoglobin (HbA1c) levels and retinal optical coherence tomography (OCT) and OCT angiography (OCTA) parameters in type 1 Diabetes Mellitus (DM). A total of 478 type 1 DM patients and 115 controls were included in a prospective OCTA trial (ClinicalTrials.gov NCT03422965). Subgroup analysis was performed for controls, no diabetic retinopathy (DM-no DR) and DR patients (DM-DR), and HbA1c levels. OCT and OCTA measurements were compared with HbA1c levels (current and previous 5 years). DM-no DR patients with HbA1c levels >7.5% showed lower VD than DM-DR and controls (20.16 vs. 20.22 vs. 20.71, p < 0.05), and showed a significant correlation between HbA1c levels and FAZc (p = 0.04), after adjusting for age, gender, signal strength index, axial length, and DM disease duration. DM-DR patients with HbA1c > 7.5% presented greater CRT than DM-no DR and controls (270.8 vs. 260 vs. 251.1, p < 0.05) and showed a significant correlation between HbA1c and CRT (p = 0.03). In conclusion, greater levels of HbA1c are associated with OCTA changes in DM-no DR patients, and with structural OCT changes in DM-DR patients. The combination of OCTA and OCT measurements and HbA1c levels may be helpful to identify patients at risk of progression to greater stages of the diabetic microvascular disease.


  • Uveitic macular edema response to intravitreal dexamethasone implant is independent of optical coherence tomography findings

    by Aina Moll-Udina, Marc Figueras-Roca, Joan Oliveres, Anna Sala-Puigdollers, Cristina Esquinas, Carmen Alba-Linero, Victor Llorenç, Alfredo Adán

    Purpose To identify predictive response optical coherence tomography (OCT) findings in uveitic macular edema (UME) treated with intravitreal dexamethasone implant (DEX). Methods Retrospective study of 66 eyes (53 patients) treated with DEX for UME. SD-OCT macular scans were collected prior to DEX treatment and 6 weeks and 3 months after the DEX implant. OCT images were evaluated for qualitative and quantitative characteristics (central retinal thickness, CRT and macular volume, MV). A multivariate analysis of covariance (ANCOVA) was carried out to study the predictive influence of OCT and clinical covariates on outcomes. The main outcome was a composite endpoint based on the simultaneous gain of 5 or more letters associated with a 20% or more reduction in CRT. Results A significant improvement in BCVA at 6 weeks (mean change from baseline −0.2, SD 0.3) and 3 months (mean −0.2, SD 0.4) was observed after the DEX implant. A significant decrease in CRT (change from baseline −187.7 μm at 3 months) and MV (change from baseline −1.7 mm3 at 3 months) were also observed. An association of ≥ 5-letter improvement in BCVA and a ≥ 20% CRT reduction was observed in 44.6% of cases at 6 weeks and 31.4% at 3 months. ANCOVA multivariate analyses found CRT at 3 months independent from baseline clinical variables but from CRT. Conclusion DEX implant is an effective treatment for UME independently of basal characteristics, producing both a gain of visual acuity and improvement of macular anatomy by OCT measures at 3 months.


  • Open Access

    Early Detection of Incipient Retinal Pigment Epithelium Atrophy Overlying Drusen with Fundus Autofluorescence vs. Spectral Domain Optical Coherence Tomography

    by Anabel Rodríguez, Marc Biarnés, Rosa M. Coco-Martin, Anna Sala-Puigdollers, Jordi Monés

    Purpose. This study aims to find out which tool, fundus autofluorescence (FAF) or spectral domain optical coherence tomography (SD-OCT), is more sensitive in detecting retinal pigment epithelium (RPE) demise overlying drusen and can, therefore, help predict geographic atrophy (GA) appearance in Age-Related Macular Degeneration (AMD). Methods. A single-site, retrospective, observational, longitudinal study was conducted. Patients with intermediate AMD (iAMD) (large (>125 μm) or intermediate (63–125 μm) drusen with hyper/hypopigmentation) with a minimum follow-up of 18 months were included. Drusen with overlying incipient RPE atrophy were identified on SD-OCT defined as choroidal hypertransmission or nascent geographic atrophy (nGA). These selected drusen were, then, traced backwards in time to determine if incipient RPE atrophy overlying drusen was observed on FAF (well-demarcated region of absence of autofluorescence) before, simultaneously, or after having detected the first signs of incipient RPE atrophy on SD-OCT. The number of drusen in which signs of incipient RPE atrophy was detected earlier using FAF or SD-OCT was compared. The time elapsed from the identification with the more sensitive method to the other was recorded and analyzed. Results. One hundred and thirty-three drusen in 22 eyes of 22 patients were included. Of these, 112 (84.2%) drusen showed choroidal hypertransmission and 21(15.8%) nGA. Early signs of atrophy overlying drusen were found simultaneously on SD-OCT and FAF in 52 cases (39.1%, 95% CI 30.8–47.9%), earliest on FAF in 51 (38.3%, 95% CI 30.0–47.2%) and first on SD-OCT in 30 (22.6%, 95% CI 15.8–30.6%; ). Statistically significant differences were found between both techniques ( ), with FAF detecting it earlier than SD-OCT. When RPE atrophy was found first on FAF, the median time to diagnosis with SD-OCT was 6.6 months (95% CI 5.5 to 8.6), while if detection occurred earlier on SD-OCT, the median time until identification with FAF was 12.6 months (95% CI 6.0 to 23.4; ). Conclusions. In iAMD cases in which early atrophy overlying drusen is not detected simultaneously in FAF and SD-OCT, FAF was significantly more sensitive. Nevertheless, a multimodal approach is recommended and required to evaluate these patients.


  • Multimodal retinal imaging of familial amyloid polyneuropathy

    by Marta Latasiewicz, Anna Sala-Puigdollers, Andrea Gonzalez-Ventosa, Elena Milla, Alfredo Adan Civera

    Background: Retinal amyloid angiopathy is a sight-threatening complication of familial amyloid polyneuropathy (FAP) caused by pathological deposition of transthyretin. The purpose of this report is to present ocular findings in patients with FAP using a combination of novel non-invasive retinal imaging techniques, including first time published images of optical coherence tomography angiography (OCT-A) in FAP. Materials and methods: Observational cross-sectional study of retinal images in patients with FAP using: fundus ultra wide-field photography (UWF); autofluorescence (AF); optical coherence tomography (OCT); and, OCT-A. Fifteen eyes of eight patients with FAP from a tertiary center were included. A descriptive analysis of obtained images and clinical data was performed. Results: Amyloid vitreous and retinal deposits were easily identified using OCT scans, AF, and UWF images, especially in the red-free modality. OCT-A allowed quality reconstruction of posterior pole vasculature, foveal avascular zone, and areas of ischemia. Conclusions: Different modalities of currently available non-invasive retinal imaging techniques, including OCT-A scans described for the first time in FAP, are safe and useful in detecting and analyzing retinal amyloidosis. Retinopathy in FAP in the studied group was more frequent than previously reported.


  • Aqueous Humour Cytokine Changes with Intravitreal Dexamethasone Implant Injection for Diabetic Macular Edema

    by Marc Figueras-Roca, Anna Sala-Puigdollers, Socorro Alforja, Josep Torras, Jorge Peraza-Nieves, Javier Zarranz-Ventura, Alfredo Adan Civera, Blanca Molins

    Purpose: To assess changes in aqueous humor (AH) levels of cytokines following dexamethasone intravitreal implant (DEX) injection for diabetic macular edema (DME). Methods: Sixteen DME and cataract cases series study. Anterior chamber AH sampling was performed at baseline at DEX injection time (T1), cataract surgery 8 weeks afterward (T2), and whenever DME relapsed (T3) in order to assess changes in IL-1β, IL-3, IL-6, IL-8, IL-10, MCP-1, IP-10, TNF-α, and VEGF levels. Results: IP-10 and MCP-1 levels significantly decreased at T2 (p = .034 and p = .044, respectively) compared to baseline (T1). Relapsed DME cases (T3) showed significantly higher levels of IL-6 (p = .028), IL-8 (p = .005), IP-10 (p = .013) and MCP-1 (p = .005) compared to T2. Conclusion: IP-10 and MCP-1 AH levels seem to be related to DEX intraocular action, decreasing after injection and increasing when DME relapses. In addition, IL-6 and IL-8 may play a role in DME late evolution and clinical relapse beyond DEX effect.


  • Long-Term Intravitreal Dexamethasone Implant Outcomes in Uveitis

    by Carmen Alba-Linero, Anna Sala-Puigdollers, Barbara Romero, Victor Llorenç, Alfredo Adan, Javier Zarranz-Ventura

    Purpose: To describe the long-term clinical outcomes in a cohort of uveitic eyes treated with the intravitreal dexamethasone implant (Ozurdex; Allergan, Inc). Methods: Seventy-nine (63 patients) receiving 134 implant injections over 82 months were included. Indication, visual acuity (VA), intraocular pressure (IOP), vitreous haze score (VHS), central retinal thickness (CRT), time to reinjection, systemic treatments, and complications data were recorded. Results: The cumulative probability of VA improvement was 80% at 1 month and 90% at 12 months, and it was maintained until 60 months. Eyes with baseline vitritis (VHS >0.5; 68%) had a probability of VHS improvement of 33% at 1 month, 75% at 12 months, and 85% at 60 months. The probability of CRT improvement was 33% at 1 month, 75% at 12 months, and 85% at 60 months. The most frequent adverse event was moderate IOP elevation (≥25 mmHg) in 30.3%, no cases of retinal detachment or endophthalmitis were observed. Conclusions: The dexamethasone implant provides favorable VA, CRT, and VHS long-term outcomes in uveitis with a reduced rate of severe adverse events.


  • Open Access

    Repeatability and reproducibility of retinal and choroidal thickness measurements in Diabetic Macular Edema using Swept-source Optical Coherence Tomography

    by Anna Sala-Puigdollers, Marc Figueras-Roca, Mireia Hereu, Teresa Hernández, Montse Morató, Alfredo Adán, Javier Zarranz-Ventura

    To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choroidal thickness were measured in the Total macular circle (TMC) and foveal central subfield (FCS) using device-integrated specific software. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were determined as a measure of repeatability and relative reliability within graders. Reproducibility was assessed using Bland-Altman plots and 95% limits of agreement (LoA) were determined as a measure of interobserver variability. Intragrader CR of retinal and choroidal thickness were 8.37 and 12.20 microns for TMC and 22.24 and 32.40 microns for FCS, and intergrader 95% LoA were 7.37–8.69 and -27.2–27.71 microns for TMC and -34.21–41.93 and -30.46–24.84 for FCS, respectively. Retinal and choroidal thickness showed very good intraobserver reliability for both TMC and FCS (ICC 0.99, LoA 0.98–0.99 in all cases). Intraobserver and interobserver variability for retinal and choroidal thickness was not significantly different for TMC (p = 0.98 and p = 0.90, p = 0.98 and p = 0.91) or FCS (p = 0.97 and p = 0.85, p = 0.78 and p = 0.73), respectively. Retinal and choroidal thickness in DME eyes can be quantified with good reliability, repeatability and reproducibility using new OCT devices that incorporate swept source technology. The technical advantages of this technology may provide new insights in the understanding of the choroidal changes related with DME.