Jennifer H. Mahaffey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jennifer H. Mahaffey has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Amrut V. Ambardekar
Division of Cardiology, Department of Medicine, University of Colorado, Aurora, CO, USA
1 shared publication - Carlin S. Long
Cardiovascular Research Institute, University of California, San Francisco
1 shared publication - Chandrasekhar Saripalli
Department of Cellular and Molecular Medicine, University of Arizona, Tucson (R.v.d.P., E.N., J.S., R.S., J.G., Z.H., C.S., J.K., K.H., O.B., J.E.S., M.M., H.G.).
1 shared publication Charles A. Dinarello
Division of Infectious Diseases, Department of Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO 80045, USA
1 shared publication- Doris Marko
University of Vienna
1 shared publication G. Del Favero
Department of Food Chemistry and Toxicology, University of Vienna, Vienna, Austria
1 shared publication
Latest Publications
- 7 February 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 10 (427)
Histone deacetylase activity governs diastolic dysfunction through a nongenomic mechanism
The histone deacetylase inhibitor ITF2357 (givinostat) prevents diastolic dysfunction by enhancing cardiac myofibril relaxation.
- 7 February 2018
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 10 (427)
Histone deacetylase activity governs diastolic dysfunction through a nongenomic mechanism
The histone deacetylase inhibitor ITF2357 (givinostat) prevents diastolic dysfunction by enhancing cardiac myofibril relaxation.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (8) , 084301
The cell-stretcher: A novel device for the mechanical stimulation of cell populations
Mechanical stimulation appears to be a critical modulator for many aspects of biology, both of living tissue and cells. The cell-stretcher, a novel device for the mechanical uniaxial stimulation of populations of cells, is described. The system is based on a variable stroke cam-lever-tappet mechanism which allows the delivery of cyclic stimuli with frequencies of up to 10 Hz and deformation between 1% and 20%. The kinematics is presented and a simulation of the dynamics of the system is shown, in order to compute the contact forces in the mechanism. The cells, following cultivation and preparation, are plated on an ad hoc polydimethylsiloxane membrane which is then loaded on the clamps of the cell-stretcher via force-adjustable magnetic couplings. In order to show the viability of the experimentation and biocompatibility of the cell-stretcher, a set of two in vitro tests were performed. Human epithelial carcinoma cell line A431 and Adult Mouse Ventricular Fibroblasts (AMVFs) from a dual reporter mouse were subject to 0.5 Hz, 24 h cyclic stretching at 15% strain, and to 48 h stimulation at 0.5 Hz and 15% strain, respectively. Visual analysis was performed on A431, showing definite morphological changes in the form of cellular extroflections in the direction of stimulation compared to an unstimulated control. A cytometric analysis was performed on the AMVF population. Results show a post-stimulation live-dead ratio deviance of less than 6% compared to control, which proves that the environment created by the cell-stretcher is suitable for in vitro experimentation.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (8) , 084301
The cell-stretcher: A novel device for the mechanical stimulation of cell populations
Mechanical stimulation appears to be a critical modulator for many aspects of biology, both of living tissue and cells. The cell-stretcher, a novel device for the mechanical uniaxial stimulation of populations of cells, is described. The system is based on a variable stroke cam-lever-tappet mechanism which allows the delivery of cyclic stimuli with frequencies of up to 10 Hz and deformation between 1% and 20%. The kinematics is presented and a simulation of the dynamics of the system is shown, in order to compute the contact forces in the mechanism. The cells, following cultivation and preparation, are plated on an ad hoc polydimethylsiloxane membrane which is then loaded on the clamps of the cell-stretcher via force-adjustable magnetic couplings. In order to show the viability of the experimentation and biocompatibility of the cell-stretcher, a set of two in vitro tests were performed. Human epithelial carcinoma cell line A431 and Adult Mouse Ventricular Fibroblasts (AMVFs) from a dual reporter mouse were subject to 0.5 Hz, 24 h cyclic stretching at 15% strain, and to 48 h stimulation at 0.5 Hz and 15% strain, respectively. Visual analysis was performed on A431, showing definite morphological changes in the form of cellular extroflections in the direction of stimulation compared to an unstimulated control. A cytometric analysis was performed on the AMVF population. Results show a post-stimulation live-dead ratio deviance of less than 6% compared to control, which proves that the environment created by the cell-stretcher is suitable for in vitro experimentation.