Jianyong Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianyong Xiang has a total of 208 co-authors. Here are the top co-authors by number of shared publications:
- Fusheng Wen
Center for High Pressure Science (CHiPS), State Key Laboratory of Metastable Materials Science and Technology, Yanshan University, Qinhuangdao, People’s Republic of China
43 shared publications - Congpu Mu
Yanshan University
38 shared publications - Zhongyuan Liu
Center for High Pressure Science, State Key Laboratory of Metastable Materials Science and Technology, Yanshan University , Qinhuangdao
35 shared publications Anmin Nie
Yanshan University
28 shared publications- Kun Zhai
Yanshan University
27 shared publications - Bochong Wang
Yanshan University
26 shared publications
Latest Publications
- 18 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (43) , 20241-20250
Laser-Induced Graphene Arrays for Dual-Function Electromagnetic Interference Shielding and Photothermal Conversion
With the rapid growth of 5G communication and wearable electronics, developing multifunctional materials has become a research hotspot. Traditional single-function materials are inadequate to meet the needs of integration and lightweight design in complex applications. In this study, the optimization of electromagnetic interference (EMI) shielding and photothermal conversion was achieved in a laser-induced graphene (LIG) system. Patterned LIG arrays with various period were fabricated on polyimide (PI) films using a CO2 laser. A sandwich-structured device was subsequently built, comprising a patterned LIG array as the top layer, PI as the middle layer, and a LIG continuous film (LIGCF) as the bottom layer. The results indicate that a decrease of the array period leads to a significant increase in both conductivity and EMI shielding performance. Specifically, the L-60 array achieves the electrical conductivity of 1985 S/m and the EMI shielding effectiveness of 35.57 dB. With the addition of a LIGCF as the bottom reflective layer, the sandwich structure further improves EMI shielding effectiveness to 49.48 dB, demonstrating an enhancement toward efficient EMI shielding. For photothermal performance, small periods of LIG arrays have higher steady-state temperature, whereas the sandwich structure exhibits a lower steady-state temperature comparing to the single-layer array. It reveals the regulation mechanism of the period on EMI shielding and photothermal conversion performance.
- 18 October 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (43) , 20241-20250
Laser-Induced Graphene Arrays for Dual-Function Electromagnetic Interference Shielding and Photothermal Conversion
With the rapid growth of 5G communication and wearable electronics, developing multifunctional materials has become a research hotspot. Traditional single-function materials are inadequate to meet the needs of integration and lightweight design in complex applications. In this study, the optimization of electromagnetic interference (EMI) shielding and photothermal conversion was achieved in a laser-induced graphene (LIG) system. Patterned LIG arrays with various period were fabricated on polyimide (PI) films using a CO2 laser. A sandwich-structured device was subsequently built, comprising a patterned LIG array as the top layer, PI as the middle layer, and a LIG continuous film (LIGCF) as the bottom layer. The results indicate that a decrease of the array period leads to a significant increase in both conductivity and EMI shielding performance. Specifically, the L-60 array achieves the electrical conductivity of 1985 S/m and the EMI shielding effectiveness of 35.57 dB. With the addition of a LIGCF as the bottom reflective layer, the sandwich structure further improves EMI shielding effectiveness to 49.48 dB, demonstrating an enhancement toward efficient EMI shielding. For photothermal performance, small periods of LIG arrays have higher steady-state temperature, whereas the sandwich structure exhibits a lower steady-state temperature comparing to the single-layer array. It reveals the regulation mechanism of the period on EMI shielding and photothermal conversion performance.
- Open Access
- 5 February 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (5)
Ultralight aerogels based on 2D van der Waals ferromagnets toward tunable and high-performance microwave absorption
The rapid advancement of communication technologies and the miniaturization of electronic devices have the demand for high-performance, lightweight microwave-absorbing materials. However, constructing efficient microwave absorbers using two-dimensional (2D) ferromagnetic materials remains a significant challenge. In this work, 2D van der Waals ferromagnetic Fe5GeTe2 (FGT) crystals were synthesized via chemical vapor transport, and FGT nanosheets were subsequently obtained through liquid-phase exfoliation. Subsequently, this study integrated FGT nanosheets with aramid nanofibers (ANFs) to construct ultralight aerogels via a synergistic vacuum-assisted filtration and freeze-drying techniques. The resulting FGT/ANF (AFGT) aerogels exhibit tunable densities (12.4–38.7 mg/cm3) and exceptional microwave absorption properties. The optimized AFGT-3 aerogel demonstrated superior microwave absorption performance, achieving a minimum reflection loss of −48.4 dB at 9.8 GHz with a thickness of 1.9 mm, alongside an effective absorption bandwidth of 3.4 GHz (9.2–12.6 GHz). This work not only pioneers the application of 2D van der Waals ferromagnets in functional aerogels but also provides a viable strategy for developing next-generation ultralight electromagnetic protection materials.
- 5 February 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (5)
Open AccessUltralight aerogels based on 2D van der Waals ferromagnets toward tunable and high-performance microwave absorption
The rapid advancement of communication technologies and the miniaturization of electronic devices have the demand for high-performance, lightweight microwave-absorbing materials. However, constructing efficient microwave absorbers using two-dimensional (2D) ferromagnetic materials remains a significant challenge. In this work, 2D van der Waals ferromagnetic Fe5GeTe2 (FGT) crystals were synthesized via chemical vapor transport, and FGT nanosheets were subsequently obtained through liquid-phase exfoliation. Subsequently, this study integrated FGT nanosheets with aramid nanofibers (ANFs) to construct ultralight aerogels via a synergistic vacuum-assisted filtration and freeze-drying techniques. The resulting FGT/ANF (AFGT) aerogels exhibit tunable densities (12.4–38.7 mg/cm3) and exceptional microwave absorption properties. The optimized AFGT-3 aerogel demonstrated superior microwave absorption performance, achieving a minimum reflection loss of −48.4 dB at 9.8 GHz with a thickness of 1.9 mm, alongside an effective absorption bandwidth of 3.4 GHz (9.2–12.6 GHz). This work not only pioneers the application of 2D van der Waals ferromagnets in functional aerogels but also provides a viable strategy for developing next-generation ultralight electromagnetic protection materials.
- 22 September 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (39) , 14497-14504
Revealing Single-Amino Acid Recognition and Cleavage Dynamics Using Plasmonic Biosensors
High-resolution proteome analysis depends on accurately determining the primary structure of proteins to advance our understanding of biological systems. Conventional peptide sequencing techniques, such as Edman degradation and mass spectrometry, often require substantial sample input, limiting their sensitivity for low-abundance proteins. Although the fluorescent method offers an alternative for single-molecule protein sequencing, the lack of a comprehensive fluorophore repertoire for labeling recognizers for all 20 amino acids impedes further development. Here, we present a versatile optical biosensing platform based on surface plasmon resonance (SPR) technology. The integration of 2D GeP5 nanosheets significantly enhances the plasmonic response, improves the sensitivity of the SPR biosensor, and scrutinizes biomolecular interactions in real time. Neoteric SPR has the unique ability to recognize and cleave the ordered appearance of N-terminal amino acids in peptides. With an excellent performance of single-residue resolution, the successive dynamics of the "recognition-cleavage-re-recognition" process are attained using the label-free biosensing method.
- 22 September 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (39) , 14497-14504
Revealing Single-Amino Acid Recognition and Cleavage Dynamics Using Plasmonic Biosensors
High-resolution proteome analysis depends on accurately determining the primary structure of proteins to advance our understanding of biological systems. Conventional peptide sequencing techniques, such as Edman degradation and mass spectrometry, often require substantial sample input, limiting their sensitivity for low-abundance proteins. Although the fluorescent method offers an alternative for single-molecule protein sequencing, the lack of a comprehensive fluorophore repertoire for labeling recognizers for all 20 amino acids impedes further development. Here, we present a versatile optical biosensing platform based on surface plasmon resonance (SPR) technology. The integration of 2D GeP5 nanosheets significantly enhances the plasmonic response, improves the sensitivity of the SPR biosensor, and scrutinizes biomolecular interactions in real time. Neoteric SPR has the unique ability to recognize and cleave the ordered appearance of N-terminal amino acids in peptides. With an excellent performance of single-residue resolution, the successive dynamics of the "recognition-cleavage-re-recognition" process are attained using the label-free biosensing method.
- 12 August 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (34) , 13031-13039
Polarization-Enhanced Janus MoSSe Plasmonic Biosensor for Accurate Diabetic Nephropathy Diagnosis
Accurate diagnosis of diabetic nephropathy (DN) is crucial for timely clinical intervention and increasingly relies on ultrasensitive detection of specific biomarkers. However, current detection methods are limited by low sensitivity and time-consuming procedures. Here, we present a Janus MoSSe-based plasmonic biosensor to significantly enhance charge sensitivity, enabling the ultrasensitive detection of DN biomarkers in urine. Through a heterogeneous engineering strategy, we synthesized Janus MoSSe monolayers with spontaneous out-of-plane polarization via chemical vapor deposition (CVD). This design amplifies charge sensitivity, leading to a significantly improved plasmonic biosensing performance, with an ultralow detection limit of 10-15 g/L for key DN biomarkers. Furthermore, our biosenor successfully detects these biomarkers in clinical urine samples, outperforming conventional methods such as ELISA and enabling accurate, stage-specific DN diagnosis. This work not only broadens the application of Janus transition metal dichalcogenide monolayers but also offers a promising platform for the advanced clinical diagnosis of DN.
- 12 August 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (34) , 13031-13039
Polarization-Enhanced Janus MoSSe Plasmonic Biosensor for Accurate Diabetic Nephropathy Diagnosis
Accurate diagnosis of diabetic nephropathy (DN) is crucial for timely clinical intervention and increasingly relies on ultrasensitive detection of specific biomarkers. However, current detection methods are limited by low sensitivity and time-consuming procedures. Here, we present a Janus MoSSe-based plasmonic biosensor to significantly enhance charge sensitivity, enabling the ultrasensitive detection of DN biomarkers in urine. Through a heterogeneous engineering strategy, we synthesized Janus MoSSe monolayers with spontaneous out-of-plane polarization via chemical vapor deposition (CVD). This design amplifies charge sensitivity, leading to a significantly improved plasmonic biosensing performance, with an ultralow detection limit of 10-15 g/L for key DN biomarkers. Furthermore, our biosenor successfully detects these biomarkers in clinical urine samples, outperforming conventional methods such as ELISA and enabling accurate, stage-specific DN diagnosis. This work not only broadens the application of Janus transition metal dichalcogenide monolayers but also offers a promising platform for the advanced clinical diagnosis of DN.
- 26 September 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (40) , 27547-27556
Atomic-Level Defect Engineering in GeP Nanoflake Biosensors for Gastric Cancer Diagnosis
Defect engineering offers a promising approach to enhance the sensitivity of biosensing materials by creating abundant chemically active sites. Despite its potential, achieving precise control and modification of these defects remains a significant challenge. Herein, we propose atomic-level defect engineering in GeP two-dimensional (2D) layered materials, following precise in situ growing Au nanoparticles on the single defect active sites for the design of ultrasensitive biosensors. The GeP-based biosensor exhibits notable capabilities for miRNA detection with excellent chemical stability, sensitivity, selectivity, and an extremely low detection limit of 28.6 aM. When applied to clinical tissue samples from gastric cancer patients, the biosensor effectively quantified the miR378c biomarker, enabling accurate stage-specific monitoring. This research not only represents a crucial advancement in the field of biosensing materials through defect engineering but also provides a promising avenue for early cancer diagnosis, staging, and monitoring.
- 26 September 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (40) , 27547-27556
Atomic-Level Defect Engineering in GeP Nanoflake Biosensors for Gastric Cancer Diagnosis
Defect engineering offers a promising approach to enhance the sensitivity of biosensing materials by creating abundant chemically active sites. Despite its potential, achieving precise control and modification of these defects remains a significant challenge. Herein, we propose atomic-level defect engineering in GeP two-dimensional (2D) layered materials, following precise in situ growing Au nanoparticles on the single defect active sites for the design of ultrasensitive biosensors. The GeP-based biosensor exhibits notable capabilities for miRNA detection with excellent chemical stability, sensitivity, selectivity, and an extremely low detection limit of 28.6 aM. When applied to clinical tissue samples from gastric cancer patients, the biosensor effectively quantified the miR378c biomarker, enabling accurate stage-specific monitoring. This research not only represents a crucial advancement in the field of biosensing materials through defect engineering but also provides a promising avenue for early cancer diagnosis, staging, and monitoring.
- 25 September 2024
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 24 (40) , 12684-12690
High-Active Surface of Centimeter-Scale β-In2S3 for Attomolar-Level Hg2+ Sensing
Recognition layer materials play a crucial role in the functionality of chemical sensors. Although advancements in two-dimensional (2D) materials have promoted sensor development, the controlled fabrication of large-scale recognition layers with highly active sites remains crucial for enhancing sensor sensitivity, especially for trace detection applications. Herein, we propose a strategy for the controlled preparation of centimeter-scale non-layered ultrathin β-In2S3 materials with tailored high-active sites to design ultrasensitive Hg2+ sensors. Our results reveal that the highly active sites of non-layered β-In2S3 materials are pivotal for achieving superior sensing performance. Selective detection of Hg2+ at the 1 aM level is achieved via selective Hg-S bonding. Additionally, we evaluate that this sensor exhibits excellent performance in detecting Hg2+ in the tap water matrix. This work provides a proof-of-concept for utilizing non-layered 2D films in high-performance sensors and highlights their potential for diverse analyte sensing applications.
- 25 September 2024
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 24 (40) , 12684-12690
High-Active Surface of Centimeter-Scale β-In2S3 for Attomolar-Level Hg2+ Sensing
Recognition layer materials play a crucial role in the functionality of chemical sensors. Although advancements in two-dimensional (2D) materials have promoted sensor development, the controlled fabrication of large-scale recognition layers with highly active sites remains crucial for enhancing sensor sensitivity, especially for trace detection applications. Herein, we propose a strategy for the controlled preparation of centimeter-scale non-layered ultrathin β-In2S3 materials with tailored high-active sites to design ultrasensitive Hg2+ sensors. Our results reveal that the highly active sites of non-layered β-In2S3 materials are pivotal for achieving superior sensing performance. Selective detection of Hg2+ at the 1 aM level is achieved via selective Hg-S bonding. Additionally, we evaluate that this sensor exhibits excellent performance in detecting Hg2+ in the tap water matrix. This work provides a proof-of-concept for utilizing non-layered 2D films in high-performance sensors and highlights their potential for diverse analyte sensing applications.
- 8 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 7 (10) , 4549-4557
High-Density Planar MoSe2/SnSe Heterojunction for Solar Energy Harvesting and Hydrogen Evolution Reaction
- 8 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 7 (10) , 4549-4557
High-Density Planar MoSe2/SnSe Heterojunction for Solar Energy Harvesting and Hydrogen Evolution Reaction
- 16 April 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (4) , 2134-2140
Plasmonic Imaging of Single DNA with Charge Sensitive Monolayer WS2
Imaging the surface charge of biomolecules such as proteins and DNA, is crucial for comprehending their structure and function. Unfortunately, current methods for label-free, sensitive, and rapid imaging of the surface charge of single DNA molecules are limited. Here, we propose a plasmonic microscopy strategy that utilizes charge-sensitive single-crystal monolayer WS2 materials to image the local charge density of a single λ-DNA molecule. Our study reveals that WS2 is a highly sensitive charge-sensitive material that can accurately measure the local charge density of λ-DNA with high spatial resolution and sensitivity. The consistency of the surface charge density values obtained from the single-crystal monolayer WS2 materials with theoretical simulations demonstrates the reliability of our approach. Our findings suggest that this class of materials has significant implications for the development of label-free, scanning-free, and rapid optical detection and charge imaging of biomolecules.
- 16 April 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (4) , 2134-2140
Plasmonic Imaging of Single DNA with Charge Sensitive Monolayer WS2
Imaging the surface charge of biomolecules such as proteins and DNA, is crucial for comprehending their structure and function. Unfortunately, current methods for label-free, sensitive, and rapid imaging of the surface charge of single DNA molecules are limited. Here, we propose a plasmonic microscopy strategy that utilizes charge-sensitive single-crystal monolayer WS2 materials to image the local charge density of a single λ-DNA molecule. Our study reveals that WS2 is a highly sensitive charge-sensitive material that can accurately measure the local charge density of λ-DNA with high spatial resolution and sensitivity. The consistency of the surface charge density values obtained from the single-crystal monolayer WS2 materials with theoretical simulations demonstrates the reliability of our approach. Our findings suggest that this class of materials has significant implications for the development of label-free, scanning-free, and rapid optical detection and charge imaging of biomolecules.
- 16 April 2024
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 24 (17) , 5301-5307
Ultrasensitive CCL2 Detection in Urine for Diabetic Nephropathy Diagnosis Using a WS2-Based Plasmonic Biosensor
The accurate diagnosis of diabetic nephropathy relies on achieving ultrasensitive biosensing for biomarker detection. However, existing biosensors face challenges such as poor sensitivity, complexity, time-consuming procedures, and high assay costs. To address these limitations, we report a WS2-based plasmonic biosensor for the ultrasensitive detection of biomarker candidates in clinical human urine samples associated with diabetic nephropathy. Leveraging plasmonic-based electrochemical impedance microscopy (P-EIM) imaging, we observed a remarkable charge sensitivity in monolayer WS2 single crystals. Our biosensor exhibits an exceptionally low detection limit (0.201 ag/mL) and remarkable selectivity in detecting CC chemokine ligand 2 (CCL2) protein biomarkers, outperforming conventional techniques such as ELISA. This work represents a breakthrough in traditional protein sensors, providing a direction and materials foundation for developing ultrasensitive sensors tailored to clinical applications for biomarker sensing.
- 16 April 2024
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 24 (17) , 5301-5307
Ultrasensitive CCL2 Detection in Urine for Diabetic Nephropathy Diagnosis Using a WS2-Based Plasmonic Biosensor
The accurate diagnosis of diabetic nephropathy relies on achieving ultrasensitive biosensing for biomarker detection. However, existing biosensors face challenges such as poor sensitivity, complexity, time-consuming procedures, and high assay costs. To address these limitations, we report a WS2-based plasmonic biosensor for the ultrasensitive detection of biomarker candidates in clinical human urine samples associated with diabetic nephropathy. Leveraging plasmonic-based electrochemical impedance microscopy (P-EIM) imaging, we observed a remarkable charge sensitivity in monolayer WS2 single crystals. Our biosensor exhibits an exceptionally low detection limit (0.201 ag/mL) and remarkable selectivity in detecting CC chemokine ligand 2 (CCL2) protein biomarkers, outperforming conventional techniques such as ELISA. This work represents a breakthrough in traditional protein sensors, providing a direction and materials foundation for developing ultrasensitive sensors tailored to clinical applications for biomarker sensing.