RLRuth P. Lim

Ruth P. Lim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ruth P. Lim has a total of 214 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated opportunistic screening for low bone mineral density using routine CT brain imaging

    by Rory Zhang, Nishant Panchal, Heinrik Choong, Charlie Ding, Haotian Huang, Stefan Kachel, Cherie Chiang, Numan Kutaiba, Ruth P. Lim

    Objectives: CT brain (CTB) scans are frequently performed in older adults, a population at increased risk of osteoporosis and low bone mineral density (BMD), presenting an opportunity for opportunistic screening. This study aims to evaluate an automated deep learning approach for opportunistic screening of low BMD and osteoporosis from routine CTB imaging. Materials and methods: A single-centre retrospective analysis was conducted on 2,014 patients (mean age 69.7 ± 14.9 years; 61% female) who underwent non-contrast CTB and dual-energy x-ray absorptiometry (DEXA) within one year of each other. A convolutional neural network incorporating automatically selected CTB slices cranial to the lateral ventricles, as well as age and sex, was trained to perform two binary classification tasks: low BMD screening ( T -score < –1.0) and osteoporosis screening ( T -score ≤ –2.5). Model performance was evaluated on a 10% hold-out test set using AUC, balanced accuracy, sensitivity, specificity, positive predictive value, and negative predictive value, with subgroup analysis by sex. Results: 22% of patients scanned had normal BMD, 44% had osteopenia, and 34% had osteoporosis. For low BMD screening, the model achieved an AUC of 0.83 (95% CI: 0.76–0.90), with AUCs of 0.88 in females and 0.76 in males. For osteoporosis screening, the model achieved an AUC of 0.78 (95% CI: 0.72–0.85), with AUCs of 0.78 in females and 0.74 in males. Conclusion: Automated analysis of routine CT brain imaging showed good discriminatory performance for opportunistic low BMD screening, particularly among females. With further validation, this approach could support earlier identification of at-risk individuals using imaging already acquired in routine clinical care.

  • Open Access

    Prognostic Value and Inter-Reader Agreement of the ANALING and DiStrict MRCP Scores in Primary Sclerosing Cholangitis

    by Thomas Goodwin, Numan Kutaiba, Mark Goodwin, Ruth P. Lim, Leon Winata, Bruno Di Muzio, William Kemp, Stuart Roberts, Natassia Tan, Ammar Majeed

    Background/Objectives: The ANALI and DiStrict scores are novel quantitative magnetic resonance cholangio-pancreatography (MRCP)-derived scoring systems designed to predict outcomes in primary sclerosing cholangitis (PSC). However, as their prognostic utility and inter-reader reproducibility are not widely validated, their utility in clinical practice is currently limited. This study aimed to assess the reproducibility and prognostic performance of the ANALI without gadolinium (ANALING) and DiStrict scores in predicting liver-related outcomes in patients with PSC. Methods: We conducted a multicentre retrospective cohort study enrolling adult patients with large-duct PSC and at least one MRCP from the time of diagnosis. MRCPs were scored by five blinded senior abdominal radiologists with inter- and intra-reader agreement assessed via intraclass correlation coefficients. Multivariate Cox proportional models were used to evaluate the prognostic value of the ANALING and DiStrict scores, with a composite endpoint of liver transplantation, hepatic decompensation, or liver-related death. Results: Eighty-nine patients with a median of 5.5 years (IQR 3.4–9.2) of follow-up were included. The ANALING score showed higher intra-reader agreement (ICC 0.87, 95% CI 0.82–0.92 vs. ICC 0.64, 95% CI 0.36–0.79) and similar inter-reader agreement (ICC 0.71, 95% CI 0.63–0.78 vs. ICC 0.67, 95% CI 0.59–0.75) compared to the DiStrict score. Only the ANALING score was associated with liver-related events, which remained significant when adjusted for age and sex (aHR 1.28, 95% CI 1.01–1.63) and MELD (aHR 1.69, 95% CI 1.22–2.34). Conclusions: The ANALING score is a reproducible, MRI-derived scoring system that is independently associated with liver outcomes and has higher intra-reader agreement compared to the DiStrict score.

  • Open Access

    Multi‐Parametric Magnetic Resonance Imaging to Assess Empagliflozin Effect on the Kidneys in People With Type 2 Diabetes Mellitus: A Pilot Clinical Trial

    by Ruth P. Lim, Salma Qassin, Lucy McKenna, Emma Hornsey, Dominic Italiano, Leonid Churilov, Richard J. MacIsaac, Jas-Mine Seah, Elif I. Ekinci, The Austin EMPA-MRI Study Group

    Aims: Empagliflozin is renoprotective in Type 2 diabetes mellitus (T2DM). Our primary aim was to assess empagliflozin's effect on glomerular filtration rate and renal vascular resistance using multiparametric MRI (MpMRI). Our secondary aim was to assess the impact of empagliflozin on additional MpMRI‐derived metrics including markers of tissue oxygenation and microstructure. Materials and Methods: Prospective randomised open‐label crossover clinical trial of adults with T2DM with eGFR ≥ 45 mL/min/1.73 m 2 and any degree of albuminuria (CKD KDIGO G1, 2 or GF3a, A1–A3). MpMRI was performed at baseline and 12‐weeks post‐empagliflozin or active comparator sitagliptin therapy in random order with an interval washout period. Brochner‐Mortensen corrected MRI‐derived GFR (MRI‐GFR), renal vascular resistance (RVR), renal blood flow (RBF) and markers of tissue hypoxia (R2*) and microstructure were measured. Impact of empagliflozin or sitagliptin on MpMRI and laboratory metrics were assessed with mixed‐effect linear regression. Results: Twelve participants (8 male, 4 female) completed all study visits. Following empagliflozin, there were significant mean decreases in MRI‐GFR (3.03 mL/min/1.73 m 2 ) and RBF (41.24 mL/min) and increased medullary hypoxia (R2* 1.81 s −1 ) compared to sitagliptin, all p < 0.05. There were no statistically significant changes to RVR, corticomedullary microstructure, eGFR or albuminuria observed with empagliflozin. Conclusions: Multiparametric MRI can non‐invasively demonstrate local renal impacts of empagliflozin beyond that of traditional markers of renal function, including decreased GFR and medullary hypoxia. Lack of RVR change may relate to lower systemic blood pressure, concurrent medication and efferent arteriolar vasodilation in T2DM. Trial Registration: ACTRN12619000933156

  • Open Access

    Abdominal aortic calcification on routine preoperative computed tomography—A novel cardiovascular risk prediction tool in liver transplant patients

    by Benjamin Cailes, Numan Kutaiba, Omar Farouque, Avik Majumdar, Thalys S. Rodrigues, Anees Enayati, Layal Abdelganne, Shannon McNamara, Nikki Garrard, Ali Al-Fiadh, et al.

    Cardiovascular (CV) disease is a leading cause of postoperative mortality following liver transplantation (LT). The presence of abdominal aortic calcification (AAC) has been linked to CV events in the general population. We sought to investigate whether AAC on routine pre-transplant CT can improve the prediction of coronary artery disease, post-LT major adverse cardiovascular events (MACEs) or long-term mortality. Of 461 patients undergoing LT between 2010 and 2018, 318 were included in the analysis, among whom 81 had also undergone computed tomography coronary angiography. The extent of AAC was quantified with high AAC defined as a calcium score ≥500. High AAC was identified in 84/318 (26.4%) and demonstrated moderate correlation with coronary artery calcium score (CACS) ( r =0.52, p p =0.02). It was also associated with a significantly increased risk of 30-day MACE (OR 2.34, 95% CI 1.08–5.05, p =0.03) and long-term mortality (HR 2.45, 95% CI 1.18–5.06, p =0.02). Following multivariate analysis adjusting for pertinent CV risk factors, high AAC remained a strong independent predictor of MACE (OR 3.10, 95% CI 1.27–7.60, p =0.02). Addition of AAC to the Revised Cardiac Risk Index significantly improved model fit for predicting MACE outcomes ( p <0.01), while the absence of heavy AAC ruled out moderate-to-severe disease on CT coronary angiography with a negative predictive value of 97.0%. High AAC on routine CT scans was associated with a 3-fold increased risk of 30-day MACE post-LT and improved CV risk prediction compared to traditional indices. Quantification of AAC may offer a simple method of improving CV risk assessment in these patients.


  • Open Access

    CT Utilisation in Emergency Department (ED) Assessment of Patients With Suspected Polytrauma: Impact of a Dedicated Trauma Surgical Team

    by Rebecca Hong, Salma Qassin, Chris Zhao, Nihal Raju, Zemar Vajuhudeen, Danielle Thom, Casey Paton, Leonid Churilov, Odkhishig Ganbold, Natalie Yang, et al.

    Introduction: We aimed to assess the impact of introduction of a dedicated trauma surgical unit (TSU) on CT utilisation for polytrauma in the Emergency Department (ED).Methods: Single centre retrospective cohort study comparing adult patients undergoing CT for polytrauma following TSU introduction (Intervention group, n = 617) to a historical Baseline group (n = 257) over a matched time period. Patient impact, including initial clinical assessment, injuries, radiation exposure, incidental findings, ED disposition, and impact on radiology services were compared with Mann–Whitney and Fisher's exact tests.Results: Intervention patients were more likely to be examined by ED physicians (96.7% vs. 91.1%, p = 0.001) prior to CT. There was greater documented clinical suspicion for chest and abdominal injuries, with increased WBCT utilisation for Intervention (Baseline 17.1% vs. 47.8%, p < 0.05), with no significant increase in positive scans by region. More CT chest (Intervention 38.4% vs. Baseline 14.8%, p < 0.05), CT abdomen (42.6% vs. 12.6%, p < 0.005) and CT pelvis (46.1% vs. 16%, p < 0.001) was performed even with low documented clinical suspicion, with no significant increase in positive findings. The intervention group returned for more additional scans (12.48% vs. Baseline 5.45%), had more incidental findings (23.66% vs. 15.18%), and were more likely to be admitted for observation (21.7% vs. 14%), all p < 0.05. Time to scan and total CT reporting time were significantly longer for Intervention.Conclusion: Introduction of a TSU was associated in a shift towards increased CT utilisation, with no increase in scan yield, increased incidental findings and impacts on Radiology workflow.


  • Patient-specific prediction of arterial wall elasticity using medical image-informed in-silico simulations

    by Manideep Roy, Xiaojing Guo, Qingdi Wang, Daniel Stäb, Ning Jin, Ruth P. Lim, Andrew Ooi, Suman Chakraborty


  • Diagnosis of bicuspid aortic valves: CT vs. TTE

    by Amy Sylivris, Zhao Feng Liu, James Theuerle, Ruth P. Lim

    Bicuspid aortic valfves (BAV) are a relatively common cardiac abnormality, with an associated risk of aortic stenosis, aortic regurgitation and aortopathy. First-line diagnosis is via transthoracic echocardiography (TTE), which may be impacted by valve calcification and operator variability. Electrocardiogram-gated computed tomography (CT) offers an alternative form of assessment. The aim of this systematic review and meta-analysis is to evaluate the diagnostic performance of TTE versus CT for BAV. Eligible studies were retrieved from inception through to March 2024 on OVID Medline, Embase and Cochrane Library. All primary studies regarding the diagnostic performance of TTE and/or CT with regards to BAV were included. The QUADAS-2 tool was utilized for quality assessment. Sensitivity and specificity data were statistically analyzed. Of 4698 records, 19 were eligible for inclusion, and 16 had sufficient data for inclusion in the meta-analysis. There was only data regarding TTE vs. retrospectively ECG-gated CT. There was a significant difference between the sensitivity of retrospectively ECG-gated cardiac CT (95.5% (95% CI: [91.3–97.5%]) and TTE (79.7%, 95% CI: [71.6–86.0%]) for identifying BAV. The specificity was high and not significantly different for both CT and TTE (96%, 95% CI: [92.5–98.2%] and 91.3%, 95% CI: [87.3–93.8%], respectively). Retrospectively ECG-gated CT demonstrates greater sensitivity for diagnosis of BAV compared to TTE. Both modalities are non-invasive and demonstrate good specificity for excluding BAV. Given that CT scans are easily accessible, they offer a reasonable second-line investigation for diagnosis of BAV when an initial TTE is inconclusive.


  • Open Access

    Automated inversion time selection for late gadolinium–enhanced cardiac magnetic resonance imaging

    by Cheng Xie, Rory Zhang, Sebastian Mensink, Rahul Gandharva, Mustafa Awni, Hester Lim, Stefan E. Kachel, Ernest Cheung, Richard Crawley, Leonid Churilov, et al.

    Objectives: To develop and share a deep learning method that can accurately identify optimal inversion time (TI) from multi-vendor, multi-institutional and multi-field strength inversion scout (TI scout) sequences for late gadolinium enhancement cardiac MRI. Materials and methods: Retrospective multicentre study conducted on 1136 1.5-T and 3-T cardiac MRI examinations from four centres and three scanner vendors. Deep learning models, comprising a convolutional neural network (CNN) that provides input to a long short-term memory (LSTM) network, were trained on TI scout pixel data from centres 1 to 3 to identify optimal TI, using ground truth annotations by two readers. Accuracy within 50 ms, mean absolute error (MAE), Lin’s concordance coefficient (LCCC) and reduced major axis regression (RMAR) were used to select the best model from validation results, and applied to holdout test data. Robustness of the best-performing model was also tested on imaging data from centre 4. Results: The best model (SE-ResNet18-LSTM) produced accuracy of 96.1%, MAE 22.9 ms and LCCC 0.47 compared to ground truth on the holdout test set and accuracy of 97.3%, MAE 15.2 ms and LCCC 0.64 when tested on unseen external (centre 4) data. Differences in vendor performance were observed, with greatest accuracy for the most commonly represented vendor in the training data. Conclusion: A deep learning model was developed that can identify optimal inversion time from TI scout images on multi-vendor data with high accuracy, including on previously unseen external data. We make this model available to the scientific community for further assessment or development. Clinical relevance statement: A robust automated inversion time selection tool for late gadolinium–enhanced imaging allows for reproducible and efficient cross-vendor inversion time selection. Key Points: • A model comprising convolutional and recurrent neural networks was developed to extract optimal TI from TI scout images. • Model accuracy within 50 ms of ground truth on multi-vendor holdout and external data of 96.1% and 97.3% respectively was achieved. • This model could improve workflow efficiency and standardise optimal TI selection for consistent LGE imaging.