Ting An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ting An has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Chengyong Zhao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publicationsGuangfu Tang
Global Energy Interconnection Research Institute, State Key Laboratory of Advanced Transmission Technology, Beijing, China
2 shared publications- Jianzhong Xu
North China Electric Power University
2 shared publications Yuke Ji
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
2 shared publications- Bjarne R. Andersen
Study Committee B4 CIGRE
1 shared publication Chengyu Li
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 10 July 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 17 (10) , 2433-2435
Guest editorial: Upscaling industrial electricity innovations to deliver net‐zero targets
- 10 July 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 17 (10) , 2433-2435
Open AccessGuest editorial: Upscaling industrial electricity innovations to deliver net‐zero targets
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (6) , 3867-3881
Analysis and Suppression Control of High Frequency Resonance for MMC-HVDC System
The high-frequency resonances (HFRs) around 700 Hz and 1.8 kHz have occurred in Yu ′ E project. Mechanism studies indicate that HFRs are caused by the interactions between the negative damping inductance characteristics of the MMC and the capacitive characteristics of the AC system. In this paper, two optimized methods regarding the current control loop are presented to suppress the HFRs. The first one is to use a round(x) function inserted into voltage feed-forward loop instead of low pass filter (LPF). The proposed method has less negative impact on transient characteristics of an MMC. The second one is to employ a second-order damping controller, including the parameters design, to reshape the MMC impedance around the multiple risky regions. The core of HFRs suppression is that the real part of the MMC impedance near the multiple intersection frequencies should be positive according to impedance stability theory. Combined with the proposed control methods and core of HFRs suppression, the simplified model of MMC is adopted to design the parameters using the analytical expressions. Moreover, the general steps of parameters design are presented. Finally, the optimized methods to suppress HFRs are verified by time-domain simulations.
- 8 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (6) , 3867-3881
Analysis and Suppression Control of High Frequency Resonance for MMC-HVDC System
The high-frequency resonances (HFRs) around 700 Hz and 1.8 kHz have occurred in Yu ′ E project. Mechanism studies indicate that HFRs are caused by the interactions between the negative damping inductance characteristics of the MMC and the capacitive characteristics of the AC system. In this paper, two optimized methods regarding the current control loop are presented to suppress the HFRs. The first one is to use a round(x) function inserted into voltage feed-forward loop instead of low pass filter (LPF). The proposed method has less negative impact on transient characteristics of an MMC. The second one is to employ a second-order damping controller, including the parameters design, to reshape the MMC impedance around the multiple risky regions. The core of HFRs suppression is that the real part of the MMC impedance near the multiple intersection frequencies should be positive according to impedance stability theory. Combined with the proposed control methods and core of HFRs suppression, the simplified model of MMC is adopted to design the parameters using the analytical expressions. Moreover, the general steps of parameters design are presented. Finally, the optimized methods to suppress HFRs are verified by time-domain simulations.
- Open Access
Control Strategies of Full-Voltage to Half-Voltage Operation for LCC and Hybrid LCC/MMC based UHVDC Systems
With the increasing demand of transmitting bulk-power over long-distance, the ultra high-voltage direct-current (UHVDC) transmission systems become an attractive option. Nowadays, not only the line commutated converter (LCC) based systems, but also the modular multilevel converter (MMC) based systems have reached UHVDC levels. The converter stations of UHVDC systems normally utilize two series-connected valve-groups to reduce the difficulties of device manufacturing and transportation. This high-voltage and low-voltage valve-group configuration allows the UHVDC systems to achieve a full-voltage to half-voltage operation which increases the flexibility of the systems. However, the existing research only focuses on the full-voltage to half-voltage control of LCC-UHVDC systems. The control strategies for hybrid LCC/MMC UHVDC systems are underresearched. Moreover, the approaches to reduce the load-shedding caused by the full-voltage to half-voltage control for both LCC and hybrid LCC/MMC based UHVDC systems have not been investigated. In this paper, full-voltage to half-voltage control strategies for both LCC and hybrid LCC/MMC based UHVDC systems have been proposed. Moreover, to avoid load-shedding caused by the half-voltage operation, a power rescheduling method that re-sets the power references of the half-voltage operating and full-voltage operating poles has been proposed. The proposed full-voltage to half-voltage control strategies and power rescheduling method can achieve a stable and fast control process with a minimum power loss. The proposed methods have been verified through the time-domain simulations conducted in PSCAD/EMTDC.
Open AccessControl Strategies of Full-Voltage to Half-Voltage Operation for LCC and Hybrid LCC/MMC based UHVDC Systems
With the increasing demand of transmitting bulk-power over long-distance, the ultra high-voltage direct-current (UHVDC) transmission systems become an attractive option. Nowadays, not only the line commutated converter (LCC) based systems, but also the modular multilevel converter (MMC) based systems have reached UHVDC levels. The converter stations of UHVDC systems normally utilize two series-connected valve-groups to reduce the difficulties of device manufacturing and transportation. This high-voltage and low-voltage valve-group configuration allows the UHVDC systems to achieve a full-voltage to half-voltage operation which increases the flexibility of the systems. However, the existing research only focuses on the full-voltage to half-voltage control of LCC-UHVDC systems. The control strategies for hybrid LCC/MMC UHVDC systems are underresearched. Moreover, the approaches to reduce the load-shedding caused by the full-voltage to half-voltage control for both LCC and hybrid LCC/MMC based UHVDC systems have not been investigated. In this paper, full-voltage to half-voltage control strategies for both LCC and hybrid LCC/MMC based UHVDC systems have been proposed. Moreover, to avoid load-shedding caused by the half-voltage operation, a power rescheduling method that re-sets the power references of the half-voltage operating and full-voltage operating poles has been proposed. The proposed full-voltage to half-voltage control strategies and power rescheduling method can achieve a stable and fast control process with a minimum power loss. The proposed methods have been verified through the time-domain simulations conducted in PSCAD/EMTDC.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 34 (1) , 826
A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids (vol 32, pg 4943, 2017)
Presents corrected author information for the paper, “A pole-to-pole shortcircuit fault current calculation method for DC grids,” (Li, C.), IEEE Trans. Power Syst., vol. 32, no. 6, pp. 4943–4953, Nov. 2017.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 34 (1) , 826
A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids (vol 32, pg 4943, 2017)
Presents corrected author information for the paper, “A pole-to-pole shortcircuit fault current calculation method for DC grids,” (Li, C.), IEEE Trans. Power Syst., vol. 32, no. 6, pp. 4943–4953, Nov. 2017.
- 11 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 34 (2) , 942-952
Low-Order Response Modeling for Wind Farm-MTDC Participating in Primary Frequency Controls
A low-order and system-level response model for wind farms (WFs) and voltage source converter based high-voltage direct current (VSC-HVDC) participating in primary frequency regulation using virtual synchronous machine (VSM) control is developed and validated. The VSM control with virtual power system stabilizer (PSS) function is presented being applicable to all multi-terminal HVDC (MTDC) VSCs. In this context, a general low-order response model (LRM) for presenting the WF-MTDC participating in the frequency control of main AC system is readily established. This modeling method derives transfer function based block diagram offering an illustrative insight into dynamic interaction between AC frequencies and DC voltages. Such a model can also provide a convenient way performing control system designing and parameter tuning. As a paradigm, LRM-based linear quadratic regulation optimization is applied to obtain the droop and damping gains for feasible frequency regulation. The effectiveness of the LRM method is verified through comparisons of the simulation results obtained from different models, controller designs, and parameter tuning approaches, which are all performed on a five-terminal VSC-HVDC connecting WF-side and main AC systems.
- 11 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 34 (2) , 942-952
Low-Order Response Modeling for Wind Farm-MTDC Participating in Primary Frequency Controls
A low-order and system-level response model for wind farms (WFs) and voltage source converter based high-voltage direct current (VSC-HVDC) participating in primary frequency regulation using virtual synchronous machine (VSM) control is developed and validated. The VSM control with virtual power system stabilizer (PSS) function is presented being applicable to all multi-terminal HVDC (MTDC) VSCs. In this context, a general low-order response model (LRM) for presenting the WF-MTDC participating in the frequency control of main AC system is readily established. This modeling method derives transfer function based block diagram offering an illustrative insight into dynamic interaction between AC frequencies and DC voltages. Such a model can also provide a convenient way performing control system designing and parameter tuning. As a paradigm, LRM-based linear quadratic regulation optimization is applied to obtain the droop and damping gains for feasible frequency regulation. The effectiveness of the LRM method is verified through comparisons of the simulation results obtained from different models, controller designs, and parameter tuning approaches, which are all performed on a five-terminal VSC-HVDC connecting WF-side and main AC systems.
- Top Cited Papers
- 15 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 32 (6) , 4943-4953
A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids
This paper proposes a generic pole-to-pole short-circuit fault current calculation method for dc grids. The calculation procedure begins from the simplified RLC equivalent model of a single modular multilevel converter, and then the prefault matrices and faulted matrices are established and modified to calculate the dc fault currents of all the branches. The proposed approaches are validated by comparing with the electromagnetic transient (EMT) simulation results on PSCAD/EMTDC. Besides, two case studies showed that the calculation method can be easily used to evaluate the severity of a dc fault. Moreover, the calculation can be applied to select the parameters of a fault current limiter (to match the circuit breaker capacity. The main contributions of the proposed numerical calculation method are: 1) The proposed method is accurate and much more time efficient than the EMT simulations; 2) the proposed method can handle all kinds of dc grid networks including the ring, radial, and meshed topologies; and 3) the proposed method is applicable to dc grid with multiple dc voltage level areas connected with dc/dc converters.
- 15 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 32 (6) , 4943-4953
Top Cited PapersA Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC Grids
This paper proposes a generic pole-to-pole short-circuit fault current calculation method for dc grids. The calculation procedure begins from the simplified RLC equivalent model of a single modular multilevel converter, and then the prefault matrices and faulted matrices are established and modified to calculate the dc fault currents of all the branches. The proposed approaches are validated by comparing with the electromagnetic transient (EMT) simulation results on PSCAD/EMTDC. Besides, two case studies showed that the calculation method can be easily used to evaluate the severity of a dc fault. Moreover, the calculation can be applied to select the parameters of a fault current limiter (to match the circuit breaker capacity. The main contributions of the proposed numerical calculation method are: 1) The proposed method is accurate and much more time efficient than the EMT simulations; 2) the proposed method can handle all kinds of dc grid networks including the ring, radial, and meshed topologies; and 3) the proposed method is applicable to dc grid with multiple dc voltage level areas connected with dc/dc converters.
- Open Access
- 1 March 2017
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 2 (1) , 1-10
Research and application on multi‐terminal and DC grids based on VSC‐HVDC technology in China
Voltage source converter (VSC)‐based high‐voltage direct current (HVDC) and multi‐terminal (MT)/DC grid technologies are the new HVDC transmission technologies after ultra‐high voltage alternative current (UHVAC) and UHVDC transmission technologies which have been widely used in China. The application of the new technologies has resulted in a rapid increase in the number of schemes in construction and planning worldwide. This has been stimulated by the greater level of functionality available from the VSC technology, which makes it suitable for a wide variety of applications. These include the integration of off‐shore wind farms, embedded links within AC networks and interconnectors, especially where the AC networks are relatively ‘weak’. VSC technology has renewed interest in MT DC systems, which may ultimately lead to wide area DC grids. This study outlines the research and application on MT and DC grids in China with respect to VSC‐HVDC key technologies and DC grid key technologies based on the presentation given in the International Workshop on Next Generation Power Equipment held on 23 September 2016 in Xian, China. The briefing details of the VSC‐HVDC projects constructed and to be constructed in China are summarised in this study.
- 1 March 2017
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 2 (1) , 1-10
Open AccessResearch and application on multi‐terminal and DC grids based on VSC‐HVDC technology in China
Voltage source converter (VSC)‐based high‐voltage direct current (HVDC) and multi‐terminal (MT)/DC grid technologies are the new HVDC transmission technologies after ultra‐high voltage alternative current (UHVAC) and UHVDC transmission technologies which have been widely used in China. The application of the new technologies has resulted in a rapid increase in the number of schemes in construction and planning worldwide. This has been stimulated by the greater level of functionality available from the VSC technology, which makes it suitable for a wide variety of applications. These include the integration of off‐shore wind farms, embedded links within AC networks and interconnectors, especially where the AC networks are relatively ‘weak’. VSC technology has renewed interest in MT DC systems, which may ultimately lead to wide area DC grids. This study outlines the research and application on MT and DC grids in China with respect to VSC‐HVDC key technologies and DC grid key technologies based on the presentation given in the International Workshop on Next Generation Power Equipment held on 23 September 2016 in Xian, China. The briefing details of the VSC‐HVDC projects constructed and to be constructed in China are summarised in this study.
- Open Access
- 26 July 2016
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 5 (2) , 262-274
HVDC grid test models for different application scenarios and load flow studies
- 26 July 2016
- Published by Springer Nature in Journal of Modern Power Systems and Clean Energy
- Vol. 5 (2) , 262-274
Open AccessHVDC grid test models for different application scenarios and load flow studies