AIAdam Imer

Adam Imer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adam Imer has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Aldrin Ocsing

    Discipline of Physiotherapy, Faculty of Health Sciences, The University of Sydney, Cumberland Campus C42, P.O. Box 170, Lidcombe, NSW 1825, Australia

    1 shared publication
  • Amy D. Sman

    Arthritis and Musculoskeletal Research Group, Faculty of Health Sciences, The University of Sydney, 75 East Street, Lidcombe, NSW 2151, Australia; Paediatric Gait Analysis Service of New South Wales, The Children's Hospital at Westmead, Hawkesbury Road, Westmead, NSW 2145, Australia

    1 shared publication
  • Claire E. Hiller

    Discipline of Physiotherapy, Faculty of Health Sciences, The University of Sydney, Cumberland Campus C42, P.O. Box 170, Lidcombe, NSW 1825, Australia

    1 shared publication
  • Joshua Burns

    Department of Epidemiology and Cancer Control St. Jude Children's Research Hospital Memphis Tennessee USA

    1 shared publication
  • Kathryn Margaret Refshauge

    Faculty of Health Sciences, The University of Sydney, Lidcombe, NSW, Australia

    1 shared publication

Latest Publications

  • Open Access

    Design and Reliability of a Novel Heel Rise Test Measuring Device for Plantarflexion Endurance

    by Amy D. Sman, Claire E. Hiller, Adam Imer, Aldrin Ocsing, Joshua Burns, Kathryn M. Refshauge

    Background. Plantarflexion results from the combined action of the soleus and gastrocnemius muscles in the calf. The heel rise test is commonly used to test calf muscle endurance, function, and performance by a wide variety of professionals; however, no uniform description of the test is available. This paper aims to document the construction and reliability of a novel heel rise test device and measurement protocol that is suitable for the needs of most individuals.Methods. This device was constructed from compact and lightweight materials and is fully adjustable, enabling the testing of a wide variety of individuals. It is easy to assemble and disassemble, ensuring that it is portable for use in different settings.Findings. We tested reliability on 40 participants, finding excellent interrater reliability (ICC2,10.97, 95% CI: 0.94 to 0.98). Limits of agreement were less than two repetitions in 90% of cases and the Bland-Altman plot showed no bias.Interpretation. We have designed a novel, standardized, simple, and reliable device and measurement protocol for the heel rise test which can be used by researchers and clinicians in a variety of settings.