Kwang-Bum Park
Research Subjects
Kwang-Bum Park has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Abdallah Menhall
Oral Surgery Department, Saint Joseph University, Beirut P.O. Box 1104-2020, Lebanon
2 shared publications - Christian Makary
Oral Surgery Department, Saint Joseph University, Beirut P.O. Box 1104-2020, Lebanon
2 shared publications - Hyun-Wook An
Department of Dental Science, Kyungpook National University, Daehak-ro, Buk-gu, Daegu 41566, Republic of Korea
2 shared publications - Pierre Lahoud
Oral Surgery Department, Saint Joseph University, Beirut P.O. Box 1104-2020, Lebanon
2 shared publications - Tonino Traini
Department of Innovative Technologies in Medicine & Dentistry, University “G. D’Annunzio” of Chieti-Pescara, Chieti, Italy
2 shared publications - Dong-Guk Ha
Institute of Science & Technology, Megagen Implant, Gyeongsan, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 16 January 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (2) , 357
Nanostructured Calcium-Incorporated Surface Compared to Machined and SLA Dental Implants—A Split-Mouth Randomized Case/Double-Control Histological Human Study
Background: Implant surface topography is a key element in achieving osseointegration. Nanostructured surfaces have shown promising results in accelerating and improving bone healing around dental implants. The main objective of the present clinical and histological study is to compare, at 4 and 6 weeks, (w) bone-to-implant contact in implants having either machined surface (MAC), sandblasted, large grit, acid-etched implant surface (SLA) medium roughness surface or a nanostructured calcium-incorporated surface (XPEED®). Methods: 35 mini-implants of 3.5 × 8.5 mm with three different surface treatments (XPEED® (n = 16)—SLA (n = 13)—MAC (n = 6), were placed in the posterior maxilla of 11 patients (6 females and 5 males) then, retrieved at either 4 or 6w in a randomized split-mouth study design. Results: The BIC rates measured at 4w and 6w respectively, were: 16.8% (±5.0) and 29.0% (±3.1) for MAC surface; 18.5% (±2.3) and 33.7% (±3.3) for SLA surface; 22.4% (±1.3) and 38.6% (±3.2) for XPEED® surface. In all types of investigated surfaces, the time factor appeared to significantly increase the bone to implant contact (BIC) rate (p < 0.05). XPEED® surface showed significantly higher BIC values when compared to both SLA and MAC values at 4w (p < 0.05). Also, at 6w, both roughened surfaces (SLA and XPEED®) showed significantly higher values (p < 0.05) than turned surface (MAC). Conclusions: Nanostructured Calcium titanate coating is able to enhance bone deposition around implants at early healing stages.
- 16 January 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (2) , 357
Open AccessNanostructured Calcium-Incorporated Surface Compared to Machined and SLA Dental Implants—A Split-Mouth Randomized Case/Double-Control Histological Human Study
Background: Implant surface topography is a key element in achieving osseointegration. Nanostructured surfaces have shown promising results in accelerating and improving bone healing around dental implants. The main objective of the present clinical and histological study is to compare, at 4 and 6 weeks, (w) bone-to-implant contact in implants having either machined surface (MAC), sandblasted, large grit, acid-etched implant surface (SLA) medium roughness surface or a nanostructured calcium-incorporated surface (XPEED®). Methods: 35 mini-implants of 3.5 × 8.5 mm with three different surface treatments (XPEED® (n = 16)—SLA (n = 13)—MAC (n = 6), were placed in the posterior maxilla of 11 patients (6 females and 5 males) then, retrieved at either 4 or 6w in a randomized split-mouth study design. Results: The BIC rates measured at 4w and 6w respectively, were: 16.8% (±5.0) and 29.0% (±3.1) for MAC surface; 18.5% (±2.3) and 33.7% (±3.3) for SLA surface; 22.4% (±1.3) and 38.6% (±3.2) for XPEED® surface. In all types of investigated surfaces, the time factor appeared to significantly increase the bone to implant contact (BIC) rate (p < 0.05). XPEED® surface showed significantly higher BIC values when compared to both SLA and MAC values at 4w (p < 0.05). Also, at 6w, both roughened surfaces (SLA and XPEED®) showed significantly higher values (p < 0.05) than turned surface (MAC). Conclusions: Nanostructured Calcium titanate coating is able to enhance bone deposition around implants at early healing stages.
- Open Access
- 29 November 2022
- Published by MDPI AG in Preprints.org
Bone-To-Implant Contact At 4- And 6-Week Healing Stages in Implants Having Either Machined, SLA Medium Roughness or Nanostructured Calcium-Incorporated Surface.
Background: Implant surface topography is a key element in achieving osseointegration. Nanostructured surfaces have shown promising results in accelerating and improving bone healing around dental implants. The main objective of the present clinical and histological study is to compare, at 4 and 6 weeks, (w) bone-to-implant contact in implants having either machined surface (MAC), SLA medium roughness surface or a Nanostructured Calcium-Incorporated sur-face (XPEED®). Methods: 35 mini-implants with 3 different surface treatments (XPEED® (n=16) – SLA (n=13) – Machined (n=6), were placed in the posterior maxilla of 11 patients then, retrieved at either 4 or 6w in a randomized split-mouth study design. Results: The BIC rate measured at 4 and 6w respectively, was: 16.8 % (±5.0) and 29.0 % (±3.1) for MAC surface; 18.5 % (±2.3) and 33.7 % (±3.3) for SLA surface; 22.4 % (±1.3) and 38.6 % (±3.2) for XPEED® surface. In all types of in-vestigated surfaces, the time factor appeared to significantly increase the BIC rate (p < .05). XPEED® surface showed a significantly higher values when compared to both SLA and MAC values at 4w (p < .05). Also, at 6w, both roughened surfaces (SLA and XPEED® ) showed signifi-cantly higher values (p < .05) than turned surface (MAC). Conclusion: Nanostructured Calcium titanate coating is able to enhance bone deposition around implants at early healing stages.
- 29 November 2022
- Published by MDPI AG in Preprints.org
Open AccessBone-To-Implant Contact At 4- And 6-Week Healing Stages in Implants Having Either Machined, SLA Medium Roughness or Nanostructured Calcium-Incorporated Surface.
Background: Implant surface topography is a key element in achieving osseointegration. Nanostructured surfaces have shown promising results in accelerating and improving bone healing around dental implants. The main objective of the present clinical and histological study is to compare, at 4 and 6 weeks, (w) bone-to-implant contact in implants having either machined surface (MAC), SLA medium roughness surface or a Nanostructured Calcium-Incorporated sur-face (XPEED®). Methods: 35 mini-implants with 3 different surface treatments (XPEED® (n=16) – SLA (n=13) – Machined (n=6), were placed in the posterior maxilla of 11 patients then, retrieved at either 4 or 6w in a randomized split-mouth study design. Results: The BIC rate measured at 4 and 6w respectively, was: 16.8 % (±5.0) and 29.0 % (±3.1) for MAC surface; 18.5 % (±2.3) and 33.7 % (±3.3) for SLA surface; 22.4 % (±1.3) and 38.6 % (±3.2) for XPEED® surface. In all types of in-vestigated surfaces, the time factor appeared to significantly increase the BIC rate (p < .05). XPEED® surface showed a significantly higher values when compared to both SLA and MAC values at 4w (p < .05). Also, at 6w, both roughened surfaces (SLA and XPEED® ) showed signifi-cantly higher values (p < .05) than turned surface (MAC). Conclusion: Nanostructured Calcium titanate coating is able to enhance bone deposition around implants at early healing stages.
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (2) , 115-121
The effect of the thread depth on the mechanical properties of the dental implant
Lee SY, et al. J Adv Prosthodont. 2015 Apr;7(2):115-121. https://doi.org/10.4047/jap.2015.7.2.115
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (2) , 115-121
Open AccessThe effect of the thread depth on the mechanical properties of the dental implant
Lee SY, et al. J Adv Prosthodont. 2015 Apr;7(2):115-121. https://doi.org/10.4047/jap.2015.7.2.115
- 21 October 2011
- Published by Wiley in Clinical Oral Implants Research
- Vol. 23 (11) , 1283-1289
The cytocompatibility and osseointegration of the Ti implants with XPEED® surfaces
Objectives This study evaluated cytocompatibility and osseointegration of the titanium (Ti) implants with resorbable blast media (RBM) surfaces produced by grit-blasting or XPEED® surfaces by coating of the nanostructured calcium. Material and methods Ti implants with XPEED® surfaces were hydrothermally prepared from Ti implants with RBM surfaces in a solution containing alkaline calcium. The surface characteristics were evaluated by using a scanning electron microscope (SEM) and surface roughness measuring system. Apatite formation was measured with SEM after immersion in modified-simulated body fluid and the amount of calcium released was measured by inductively coupled plasma optical emission. The cell proliferation was investigated by MTT assay and the cell attachment was evaluated by SEM in MC3T3-E1 pre-osteoblast cells. Thirty implants with RBM surfaces and 30 implants with XPEED® surfaces were placed in the proximal tibiae and in the femoral condyles of 10 New Zealand White rabbits. The osseointegration was evaluated by a removal torque test in the proximal tibiae and by histomorphometric analysis in the femoral condyles 4 weeks after implantation. Results The Ti implants with XPEED® surfaces showed a similar surface morphology and surface roughness to those of the Ti implants with RBM surfaces. The amount of calcium ions released from the surface of the Ti implants with XPEED® surfaces was much more than the Ti implants with RBM surfaces (P < 0.05). The cell proliferation and cell attachment of the Ti implants showed a similar pattern to those of the Ti implants with RBM surfaces (P > 0.1). Apatite deposition significantly increased in all surfaces of the Ti implants with XPEED® surfaces. The removable torque value (P = 0.038) and percentage of bone-to-implant contact (BIC%) (P = 0.03) was enhanced in the Ti implants with XPEED® surfaces. Conclusion The Ti implants with XPEED® surfaces significantly enhanced apatite formation, removal torque value, and the BIC%. The Ti implants with XPEED® surfaces may induce strong bone integration by improving osseointegration of grit-blasted Ti implants in areas of poor quality bone.
- 21 October 2011
- Published by Wiley in Clinical Oral Implants Research
- Vol. 23 (11) , 1283-1289
The cytocompatibility and osseointegration of the Ti implants with XPEED® surfaces
Objectives This study evaluated cytocompatibility and osseointegration of the titanium (Ti) implants with resorbable blast media (RBM) surfaces produced by grit-blasting or XPEED® surfaces by coating of the nanostructured calcium. Material and methods Ti implants with XPEED® surfaces were hydrothermally prepared from Ti implants with RBM surfaces in a solution containing alkaline calcium. The surface characteristics were evaluated by using a scanning electron microscope (SEM) and surface roughness measuring system. Apatite formation was measured with SEM after immersion in modified-simulated body fluid and the amount of calcium released was measured by inductively coupled plasma optical emission. The cell proliferation was investigated by MTT assay and the cell attachment was evaluated by SEM in MC3T3-E1 pre-osteoblast cells. Thirty implants with RBM surfaces and 30 implants with XPEED® surfaces were placed in the proximal tibiae and in the femoral condyles of 10 New Zealand White rabbits. The osseointegration was evaluated by a removal torque test in the proximal tibiae and by histomorphometric analysis in the femoral condyles 4 weeks after implantation. Results The Ti implants with XPEED® surfaces showed a similar surface morphology and surface roughness to those of the Ti implants with RBM surfaces. The amount of calcium ions released from the surface of the Ti implants with XPEED® surfaces was much more than the Ti implants with RBM surfaces (P < 0.05). The cell proliferation and cell attachment of the Ti implants showed a similar pattern to those of the Ti implants with RBM surfaces (P > 0.1). Apatite deposition significantly increased in all surfaces of the Ti implants with XPEED® surfaces. The removable torque value (P = 0.038) and percentage of bone-to-implant contact (BIC%) (P = 0.03) was enhanced in the Ti implants with XPEED® surfaces. Conclusion The Ti implants with XPEED® surfaces significantly enhanced apatite formation, removal torque value, and the BIC%. The Ti implants with XPEED® surfaces may induce strong bone integration by improving osseointegration of grit-blasted Ti implants in areas of poor quality bone.