Simone Mattei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simone Mattei has a total of 227 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Jomaa
Department of Molecular Physiology and Biological Physics, University of Virginia, Charlottesville, USA
8 shared publications - Hans-Georg Kräusslich
Department of Infectious Diseases, Virology, Heidelberg University, Heidelberg, Germany
6 shared publications - John A. G. Briggs
Department of Cell and Virus Structure, Max Planck Institute of Biochemistry, Martinsried, Germany
6 shared publications - Daniel Boehringer
Cryo-EM Knowledge Hub (CEMK), ETH Zurich, Zurich, Switzerland
5 shared publications - Simon A. Fromm
EMBL Imaging Centre, European Molecular Biology Laboratory, Meyerhofstr. 1, 69117 Heidelberg, Germany
5 shared publications - Barbara Müller
Department of Infectious Diseases, Virology, Heidelberg University, Heidelberg, Germany
4 shared publications
Latest Publications
- Open Access
Super-Resolution Processing Enables In Situ Subtomogram Averaging Beyond the Nyquist Limit
In situ subtomogram averaging (STA) for high-resolution structure determination requires fine pixel sampling, forcing a trade-off between achievable resolution and the field of view (FOV) recorded in each tomogram. Electron-event representation (EER) data can be rendered at half the physical pixel size, but whether super-resolution processing can recover useful information beyond the physical Nyquist limit from noisy in situ data remains unclear. Here, we show that super-resolution processing of EER data recovers biologically interpretable information beyond a physical Nyquist limit of 4.78 Å in two in situ datasets. STA of unidentified virus particles in a Drosophila melanogaster larva yielded a 3.42 Å inner capsid reconstruction, enabling de novo model building and identification of the particles as Drosophila A virus. In situ STA of ribosomes in Saccharomyces cerevisiae reached 3.18 Å, with local resolution extending to 2.78 Å. EER acquisition therefore provides greater flexibility in choosing the acquisition magnification: existing datasets can be re-rendered at the super-resolution pixel size when physical sampling becomes limiting, while lower-magnification acquisition can be considered when a larger FOV improves target capture or cellular context.
Open AccessSuper-Resolution Processing Enables In Situ Subtomogram Averaging Beyond the Nyquist Limit
In situ subtomogram averaging (STA) for high-resolution structure determination requires fine pixel sampling, forcing a trade-off between achievable resolution and the field of view (FOV) recorded in each tomogram. Electron-event representation (EER) data can be rendered at half the physical pixel size, but whether super-resolution processing can recover useful information beyond the physical Nyquist limit from noisy in situ data remains unclear. Here, we show that super-resolution processing of EER data recovers biologically interpretable information beyond a physical Nyquist limit of 4.78 Å in two in situ datasets. STA of unidentified virus particles in a Drosophila melanogaster larva yielded a 3.42 Å inner capsid reconstruction, enabling de novo model building and identification of the particles as Drosophila A virus. In situ STA of ribosomes in Saccharomyces cerevisiae reached 3.18 Å, with local resolution extending to 2.78 Å. EER acquisition therefore provides greater flexibility in choosing the acquisition magnification: existing datasets can be re-rendered at the super-resolution pixel size when physical sampling becomes limiting, while lower-magnification acquisition can be considered when a larger FOV improves target capture or cellular context.
- Open Access
- 26 August 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 9068
Dual apical methyltransferases orchestrate motility initiation in apicomplexan parasites
Apicomplexan parasites such as Toxoplasma gondii initiate motility through rapid, spatially confined cytoskeletal activation at their apical end. While calcium-, lipid-, and kinase-based signalling pathways have been partially elucidated, how these cues are translated into mechanical force remains unclear. Here, we uncover a dual methyltransferase mechanism that orchestrates this process. We characterise Tg PCKMT, a PreConoidal ring–associated lysine (K) MethylTransferase, as an essential upstream regulator of motility. Tg PCKMT anchors the actin nucleator Formin-1 ( Tg FRM1) at the conoid, enabling conoid protrusion and F-actin assembly. Loss of Tg PCKMT abolishes Tg FRM1 recruitment, blocks conoid extrusion, and arrests invasion and egress despite preserved conoid structure. In contrast, the apical methyltransferase Tg AKMT, previously linked to motility through recruitment of the glideosome-associated connector ( Tg GAC), acts downstream, disengaging from the conoid upon activation and likely promoting Tg GAC-dependent force transmission. Tg PCKMT depletion prevents Tg AKMT translocation, revealing that actin assembly and lysine methylation are mechanistically coupled. Together, these findings define a two-step methylation regulatory module that coordinates actin nucleation with force propagation, uncovering methylation as a central regulatory axis for motility initiation in apicomplexan parasites.
- 26 August 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1) , 9068
Open AccessDual apical methyltransferases orchestrate motility initiation in apicomplexan parasites
Apicomplexan parasites such as Toxoplasma gondii initiate motility through rapid, spatially confined cytoskeletal activation at their apical end. While calcium-, lipid-, and kinase-based signalling pathways have been partially elucidated, how these cues are translated into mechanical force remains unclear. Here, we uncover a dual methyltransferase mechanism that orchestrates this process. We characterise Tg PCKMT, a PreConoidal ring–associated lysine (K) MethylTransferase, as an essential upstream regulator of motility. Tg PCKMT anchors the actin nucleator Formin-1 ( Tg FRM1) at the conoid, enabling conoid protrusion and F-actin assembly. Loss of Tg PCKMT abolishes Tg FRM1 recruitment, blocks conoid extrusion, and arrests invasion and egress despite preserved conoid structure. In contrast, the apical methyltransferase Tg AKMT, previously linked to motility through recruitment of the glideosome-associated connector ( Tg GAC), acts downstream, disengaging from the conoid upon activation and likely promoting Tg GAC-dependent force transmission. Tg PCKMT depletion prevents Tg AKMT translocation, revealing that actin assembly and lysine methylation are mechanistically coupled. Together, these findings define a two-step methylation regulatory module that coordinates actin nucleation with force propagation, uncovering methylation as a central regulatory axis for motility initiation in apicomplexan parasites.
- Open Access
- 28 July 2026
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 82 (8) , 990-997
LowDoseWizard : rapid and standardized setup of low-dose cryo-TEM imaging in SerialEM
Structure elucidation of biological macromolecules by single-particle cryogenic electron microscopy (SPA cryo-EM) or cryogenic electron tomography (cryo-ET) relies on low-dose imaging on cryogenic transmission electron microscopes (cryo-TEMs). Routine microscope setup remains technically demanding and can be time-consuming, particularly for inexperienced or infrequent users. We present LowDoseWizard , a guided workflow implemented in SerialEM that enables rapid and standardized setup of cryo-TEM imaging conditions. From minimal user input, the workflow configures microscope optics, camera parameters and image-shift settings for all low-dose states, and guides the user through key daily alignment procedures, including beam-shift offset calibration, objective-lens astigmatism correction and coma-free alignment. The workflow is organized into modular routines that can be executed sequentially or independently, while microscope-specific acquisition parameters are defined in editable configuration files, allowing flexible adaptation to different instruments without modification of the core scripts. Across user sessions on three microscopes at EMBL Heidelberg, the complete setup required on average less than 15 min. To assess whether predefined imaging conditions generated by the workflow are compatible with high-resolution data collection, we acquired apoferritin data on a 200 kV Glacios and a 300 kV Titan Krios. These datasets yielded reconstructions at 1.62 and 1.09 Å resolution, respectively, demonstrating that rapid, guided setup can support near-atomic and atomic-resolution SPA cryo-EM. LowDoseWizard lowers the barrier to robust cryo-TEM setup, reduces the time spent on routine parameter selection and alignment, and helps users focus on sample-specific aspects of data acquisition such as target selection. The workflow should be particularly valuable in shared instrumentation environments, where accessibility, reproducibility and efficient microscope use are critical.
- 28 July 2026
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 82 (8) , 990-997
Open AccessLowDoseWizard : rapid and standardized setup of low-dose cryo-TEM imaging in SerialEM
Structure elucidation of biological macromolecules by single-particle cryogenic electron microscopy (SPA cryo-EM) or cryogenic electron tomography (cryo-ET) relies on low-dose imaging on cryogenic transmission electron microscopes (cryo-TEMs). Routine microscope setup remains technically demanding and can be time-consuming, particularly for inexperienced or infrequent users. We present LowDoseWizard , a guided workflow implemented in SerialEM that enables rapid and standardized setup of cryo-TEM imaging conditions. From minimal user input, the workflow configures microscope optics, camera parameters and image-shift settings for all low-dose states, and guides the user through key daily alignment procedures, including beam-shift offset calibration, objective-lens astigmatism correction and coma-free alignment. The workflow is organized into modular routines that can be executed sequentially or independently, while microscope-specific acquisition parameters are defined in editable configuration files, allowing flexible adaptation to different instruments without modification of the core scripts. Across user sessions on three microscopes at EMBL Heidelberg, the complete setup required on average less than 15 min. To assess whether predefined imaging conditions generated by the workflow are compatible with high-resolution data collection, we acquired apoferritin data on a 200 kV Glacios and a 300 kV Titan Krios. These datasets yielded reconstructions at 1.62 and 1.09 Å resolution, respectively, demonstrating that rapid, guided setup can support near-atomic and atomic-resolution SPA cryo-EM. LowDoseWizard lowers the barrier to robust cryo-TEM setup, reduces the time spent on routine parameter selection and alignment, and helps users focus on sample-specific aspects of data acquisition such as target selection. The workflow should be particularly valuable in shared instrumentation environments, where accessibility, reproducibility and efficient microscope use are critical.
- Open Access
PinCorr: A high-pressure freezing carrier with intrinsic landmarks for cryo-correlative light and electron microscopy
Cryo-correlative light and electron microscopy methods enable targeted structural analysis of fluorescently labelled features in vitrified specimens. However, correlative workflows on high-pressure frozen samples often remain challenging due to the lack of persistent landmarks for reliable sample tracking and image registration between different microscopes. Standard high-pressure freezing carriers provide little intrinsic reference information, as the exposed sample surface is often smooth and rotationally ambiguous, complicating localisation of regions of interest across imaging platforms. Here, we introduce PinCorr, a 3-mm high-pressure freezing carrier with an integrated coordinate system formed by four asymmetrically arranged pillars with distinct geometries. These built-in landmarks remain visible after freezing and provide a stable, sample-independent reference frame for orientation and correlation between cryo-fluorescence microscopy and electron microscopy. We show that PinCorr supports fluorescence-guided cryo-volume imaging, serial lift-out for cryo-electron tomography and freeze-substitution workflows followed by room-temperature on-section correlation. PinCorr thus provides a hardware-based approach to establishing a persistent spatial reference frame in HPF-based correlative imaging workflows for thick and multicellular specimens.
Open AccessPinCorr: A high-pressure freezing carrier with intrinsic landmarks for cryo-correlative light and electron microscopy
Cryo-correlative light and electron microscopy methods enable targeted structural analysis of fluorescently labelled features in vitrified specimens. However, correlative workflows on high-pressure frozen samples often remain challenging due to the lack of persistent landmarks for reliable sample tracking and image registration between different microscopes. Standard high-pressure freezing carriers provide little intrinsic reference information, as the exposed sample surface is often smooth and rotationally ambiguous, complicating localisation of regions of interest across imaging platforms. Here, we introduce PinCorr, a 3-mm high-pressure freezing carrier with an integrated coordinate system formed by four asymmetrically arranged pillars with distinct geometries. These built-in landmarks remain visible after freezing and provide a stable, sample-independent reference frame for orientation and correlation between cryo-fluorescence microscopy and electron microscopy. We show that PinCorr supports fluorescence-guided cryo-volume imaging, serial lift-out for cryo-electron tomography and freeze-substitution workflows followed by room-temperature on-section correlation. PinCorr thus provides a hardware-based approach to establishing a persistent spatial reference frame in HPF-based correlative imaging workflows for thick and multicellular specimens.
- Open Access
- 23 June 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (7) , 1359-1367
EasyGrid: a versatile platform for automated cryo-EM sample preparation and quality control
Optimized sample preparation is essential for imaging biological macromolecules in their native state using single-particle cryo-electron microscopy (cryo-EM) or in situ cryo-electron tomography (cryo-ET). Here we present EasyGrid, a modular, automated platform designed to streamline and standardize cryo-EM/ET sample preparation. EasyGrid integrates in-line plasma treatment of the sample support, microfluidic dispensing, blot-less sample spreading, jet-based vitrification and grid quality control via light interferometry. We demonstrate its effectiveness by preparing grids for multiple purified macromolecular complexes and resolving their structures with cryo-EM. Additionally, EasyGrid achieves improved vitrification of large mammalian cells compared to conventional plunge-freezing. By enabling systematic and high-throughput optimization, EasyGrid provides a robust and time-saving solution for both structural and cellular cryo-EM applications.
- 23 June 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (7) , 1359-1367
Open AccessEasyGrid: a versatile platform for automated cryo-EM sample preparation and quality control
Optimized sample preparation is essential for imaging biological macromolecules in their native state using single-particle cryo-electron microscopy (cryo-EM) or in situ cryo-electron tomography (cryo-ET). Here we present EasyGrid, a modular, automated platform designed to streamline and standardize cryo-EM/ET sample preparation. EasyGrid integrates in-line plasma treatment of the sample support, microfluidic dispensing, blot-less sample spreading, jet-based vitrification and grid quality control via light interferometry. We demonstrate its effectiveness by preparing grids for multiple purified macromolecular complexes and resolving their structures with cryo-EM. Additionally, EasyGrid achieves improved vitrification of large mammalian cells compared to conventional plunge-freezing. By enabling systematic and high-throughput optimization, EasyGrid provides a robust and time-saving solution for both structural and cellular cryo-EM applications.
- Open Access
- 13 May 2026
- Published by Springer Nature in Nature
- Vol. 655 (8122) , 516-524
SNOR promotes translation restart after dormancy
Cellular dormancy enables survival during prolonged nutrient limitation by reversibly suppressing protein synthesis 1–4 . How inactive eukaryotic ribosomes are reactivated when nutrients return remains unclear. Here, using high-resolution in situ cryo-electron tomography in Schizosaccharomyces pombe , we identify SNOR, an SBDS domain-containing ribosome-associated factor that binds at the peptidyl transferase centre and contacts the hypusinated loop of eIF5A during glucose depletion-induced dormancy. Rather than acting as a canonical hibernation factor, SNOR licenses dormant ribosomes for rapid translational restart. Upon glucose repletion, SNOR and eIF5A act together to promote efficient recovery of polysomes and exit from dormancy. These findings define a stress-responsive ribosome restart module that couples carbon-source limitation to surveillance of the ribosomal active site and reactivation of protein synthesis.
- 13 May 2026
- Published by Springer Nature in Nature
- Vol. 655 (8122) , 516-524
Open AccessSNOR promotes translation restart after dormancy
Cellular dormancy enables survival during prolonged nutrient limitation by reversibly suppressing protein synthesis 1–4 . How inactive eukaryotic ribosomes are reactivated when nutrients return remains unclear. Here, using high-resolution in situ cryo-electron tomography in Schizosaccharomyces pombe , we identify SNOR, an SBDS domain-containing ribosome-associated factor that binds at the peptidyl transferase centre and contacts the hypusinated loop of eIF5A during glucose depletion-induced dormancy. Rather than acting as a canonical hibernation factor, SNOR licenses dormant ribosomes for rapid translational restart. Upon glucose repletion, SNOR and eIF5A act together to promote efficient recovery of polysomes and exit from dormancy. These findings define a stress-responsive ribosome restart module that couples carbon-source limitation to surveillance of the ribosomal active site and reactivation of protein synthesis.
- Open Access
LowDoseWizard – rapid and standardised setup of low-dose cryo-TEM imaging in SerialEM
Structure elucidation of biological macromolecules by single particle cryogenic electron microscopy (SPA cryo-EM) or cryogenic electron tomography (cryo-ET) relies on low-dose imaging on cryogenic transmission electron microscopes (cryo-TEMs). Routine microscope setup remains technically demanding and can be time-consuming, particularly for inexperienced or infrequent users. We present LowDoseWizard, a guided workflow implemented in SerialEM that enables rapid and standardised setup of cryo-TEM imaging conditions. From minimal user input, the workflow configures microscope optics, camera parameters and image shift settings for all low-dose imaging states, and guides the user through key daily alignment procedures including beam shift offset calibration, objective lens astigmatism correction and coma-free alignment. The workflow is organised into modular routines that can be executed sequentially or independently, while microscope-specific acquisition parameters are defined in editable configuration files, allowing flexible adaptation to different instruments without modification of the core scripts. Across user sessions on three microscopes at EMBL Heidelberg, the complete setup required on average less than 15 minutes. To assess whether predefined imaging conditions generated by the workflow are compatible with high-resolution data collection, we acquired apoferritin data on a 200 kV Glacios and a 300 kV Titan Krios. These datasets yielded reconstructions at 1.62 Å and 1.09 Å resolution, respectively, demonstrating that rapid, guided setup can support near-atomic and atomic-resolution single particle cryo-EM. LowDoseWizard lowers the barrier to robust cryo-TEM setup, reduces the time spent on routine parameter selection and alignment, and helps users focus on sample-specific aspects of data acquisition such as target selection. The workflow should be particularly valuable in shared instrumentation environments, where accessibility, reproducibility and efficient microscope use are critical.
Open AccessLowDoseWizard – rapid and standardised setup of low-dose cryo-TEM imaging in SerialEM
Structure elucidation of biological macromolecules by single particle cryogenic electron microscopy (SPA cryo-EM) or cryogenic electron tomography (cryo-ET) relies on low-dose imaging on cryogenic transmission electron microscopes (cryo-TEMs). Routine microscope setup remains technically demanding and can be time-consuming, particularly for inexperienced or infrequent users. We present LowDoseWizard, a guided workflow implemented in SerialEM that enables rapid and standardised setup of cryo-TEM imaging conditions. From minimal user input, the workflow configures microscope optics, camera parameters and image shift settings for all low-dose imaging states, and guides the user through key daily alignment procedures including beam shift offset calibration, objective lens astigmatism correction and coma-free alignment. The workflow is organised into modular routines that can be executed sequentially or independently, while microscope-specific acquisition parameters are defined in editable configuration files, allowing flexible adaptation to different instruments without modification of the core scripts. Across user sessions on three microscopes at EMBL Heidelberg, the complete setup required on average less than 15 minutes. To assess whether predefined imaging conditions generated by the workflow are compatible with high-resolution data collection, we acquired apoferritin data on a 200 kV Glacios and a 300 kV Titan Krios. These datasets yielded reconstructions at 1.62 Å and 1.09 Å resolution, respectively, demonstrating that rapid, guided setup can support near-atomic and atomic-resolution single particle cryo-EM. LowDoseWizard lowers the barrier to robust cryo-TEM setup, reduces the time spent on routine parameter selection and alignment, and helps users focus on sample-specific aspects of data acquisition such as target selection. The workflow should be particularly valuable in shared instrumentation environments, where accessibility, reproducibility and efficient microscope use are critical.
- Open Access
- 16 April 2026
- Published by EMBL-EBI
Mouse heavy-chain apoferritin on continuous carbon from 200 kV Glacios
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 16 April 2026
- Published by EMBL-EBI
Open AccessMouse heavy-chain apoferritin on continuous carbon from 200 kV Glacios
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
- 14 April 2026
- Published by EMBL-EBI
Mouse heavy-chain apoferritin on continuous carbon from 300 kV Titan Krios
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- 14 April 2026
- Published by EMBL-EBI
Open AccessMouse heavy-chain apoferritin on continuous carbon from 300 kV Titan Krios
EMPIAR, the Electron Microscopy Public Image Archive centered at EMBL-EBI, is a public resource for raw electron microscopy images related to EMDB, contains micrographs, particle sets and tilt-series.
- Open Access
A Novel Eukaryotic Ribosome Factor Enables Translation Restart Following Cellular Dormancy
Dormancy is a survival strategy employed by all domains of life to withstand prolonged nutrient deprivation and environmental stress that is marked by a global shutdown of protein synthesis. However, the molecular mechanisms driving ribosome inactivation and reactivation during and after dormancy in eukaryotes remain poorly understood. Here, we identify SNOR, a novel SBDS-like ribosome-associated factor in Schizosaccharomyces pombe, that is upregulated and associates with ribosomes during induced dormancy triggered by glucose depletion. SNOR contributes to protein synthesis repression by binding the ribosome to probe the peptidyl transferase center (PTC), block tRNA-binding sites, and cap the polypeptide exit tunnel (PET). Importantly, we show that SNOR is essential for the restart of protein synthesis upon glucose reintroduction and exit from dormancy. SNOR is evolutionarily conserved and specifically upregulated in response to glucose stress in fungi. These findings reveal a previously unrecognized ribosome-associated factor that links glucose stress and cellular dormancy to surveillance of protein synthesis and highlight the power of in situ structural biology to uncover stress-responsive regulators of translation.
Open AccessA Novel Eukaryotic Ribosome Factor Enables Translation Restart Following Cellular Dormancy
Dormancy is a survival strategy employed by all domains of life to withstand prolonged nutrient deprivation and environmental stress that is marked by a global shutdown of protein synthesis. However, the molecular mechanisms driving ribosome inactivation and reactivation during and after dormancy in eukaryotes remain poorly understood. Here, we identify SNOR, a novel SBDS-like ribosome-associated factor in Schizosaccharomyces pombe, that is upregulated and associates with ribosomes during induced dormancy triggered by glucose depletion. SNOR contributes to protein synthesis repression by binding the ribosome to probe the peptidyl transferase center (PTC), block tRNA-binding sites, and cap the polypeptide exit tunnel (PET). Importantly, we show that SNOR is essential for the restart of protein synthesis upon glucose reintroduction and exit from dormancy. SNOR is evolutionarily conserved and specifically upregulated in response to glucose stress in fungi. These findings reveal a previously unrecognized ribosome-associated factor that links glucose stress and cellular dormancy to surveillance of protein synthesis and highlight the power of in situ structural biology to uncover stress-responsive regulators of translation.