Saad Mahmood Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saad Mahmood Ali has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Jenan S. Kashan
Biomedical Engineering Department, College of Engineering, University of Technology, Baghdad, Iraq
3 shared publicationsSamir Ali Amin
University of Technology
2 shared publicationsShurooq S. Mahmood
Al Iraqia University
2 shared publicationsAbdullah N. Abdel Abbas
Biomedical Engineering Department, University of Technology, Baghdad, Iraq
1 shared publicationAhmed Al-Khazraji
1 shared publicationAhmed Naif Al-Khazraji
University of Technology
1 shared publication
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 470-482
Design and Development of a Wearable Assistive Device for Enhancing Mobility and Balance in Elderly Individuals
- 2 August 2026
- Published by Springer Nature
- p. 470-482
Design and Development of a Wearable Assistive Device for Enhancing Mobility and Balance in Elderly Individuals
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3091 (1) , 030004
Design of a paediatric occupational therapy device to improve cognitive and physical capabilities in cases of ataxia
Some children have problems concentrating and difficulty in using their hands for basic daily activities due to a condition known as ataxia, which has many caus Some children have problems concentrating and difficulty in using their hands for basic daily activities due to a condition known as ataxia, which has many caus
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3091 (1) , 030004
Design of a paediatric occupational therapy device to improve cognitive and physical capabilities in cases of ataxia
Some children have problems concentrating and difficulty in using their hands for basic daily activities due to a condition known as ataxia, which has many caus Some children have problems concentrating and difficulty in using their hands for basic daily activities due to a condition known as ataxia, which has many caus
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3091 (1) , 040006
Design and implementation of an ambulance drone prototype for emergency medical deliveries
The world was stunned and shocked at the beginning of the novel coronavirus (Covid 19) pandemic by the lack of medical equipment and failure of hospital deliver The world was stunned and shocked at the beginning of the novel coronavirus (Covid 19) pandemic by the lack of medical equipment and failure of hospital deliver
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3091 (1) , 040006
Design and implementation of an ambulance drone prototype for emergency medical deliveries
The world was stunned and shocked at the beginning of the novel coronavirus (Covid 19) pandemic by the lack of medical equipment and failure of hospital deliver The world was stunned and shocked at the beginning of the novel coronavirus (Covid 19) pandemic by the lack of medical equipment and failure of hospital deliver
- Open Access
- 1 January 2024
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 37 (2) , 237-251
A Novel Design and Simulation of a Nano Prosthetic Artificial Heart Valves
Heart valve replacement is a major health burden and is required by millions of people worldwide, which invites the continuous need to discover and manufacture more effective and permanent artificial replacements. In the present work, unique models of eight artificial heart valves were designed and examined using seven synthetic and nanocomposite materials. The designed valves were examined to determine the best designs and materials in terms of durability, flexibility, and energy consumption, and to improve the biomechanical performance by using the Response Surface Methodology (RSM) and the Design Expert System 13. The highest values of the equivalent stress due to the applied blood pressure on the moving parts on each type of manufactured heart valve occur in valves with three dimensions moving parts, reached in the mitral tri-leaflet valve 14.13 MPa, followed by the tricuspid aortic valve. The equivalent stresses for other types of valves produced with simple surface action were lower than 2 MPa. The strain energy that is expended during the process of diastole and systole was found to be directly proportional to the strength and flexibility of the materials used. The energy consumption rates decrease when using highly elastic materials such as TPE and PSN4. The values of this energy also increase with an increase in the area of the moving parts of the valve, especially when faced with the process of closing blood flow, as with the use of the tricuspid aortic valve (TAV). The highest total deformation resulted in the valve body when using TPU, followed by TPE, nylon, PETG, and PLA, while the lowest deformation rates were observed when using PSN4, which ranged from 5x105 to 0.1 mm, followed by SIBSTAR103 nanostructured rubber. The obtained values of stress safety factors were decreased with the complexity of the movement for the moving parts of the valve. The highest rates were recorded when using the tricuspid mitral valve, reaching 2.45 when using the high-strength and flexible PSN4 nanomaterial. It can be concluded that the best materials for manufacturing these four types of valves are the PSN4, followed by SIBSTAR103T, TPU, and TPE. The use of PETG, PLA, and nylon materials is not recommended for the manufacture of any prosthetic heart valves, due to their lack of strength, flexibility, and high brittleness, especially for PETG and PLA materials. It was also noted here that PSN4 is the only material suitable for the manufacture of mitral tri-leaflet and tricuspid mitral valve artificial valves. For other types of valves manufactured with a single leaflet, high safety stress factors were obtained because their movement is simple, flat, and in one direction, where the highest values were observed when testing a single hemispherical leaflet type valve, then the conical caged ball and the caged ball type, respectively.
- 1 January 2024
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 37 (2) , 237-251
Open AccessA Novel Design and Simulation of a Nano Prosthetic Artificial Heart Valves
Heart valve replacement is a major health burden and is required by millions of people worldwide, which invites the continuous need to discover and manufacture more effective and permanent artificial replacements. In the present work, unique models of eight artificial heart valves were designed and examined using seven synthetic and nanocomposite materials. The designed valves were examined to determine the best designs and materials in terms of durability, flexibility, and energy consumption, and to improve the biomechanical performance by using the Response Surface Methodology (RSM) and the Design Expert System 13. The highest values of the equivalent stress due to the applied blood pressure on the moving parts on each type of manufactured heart valve occur in valves with three dimensions moving parts, reached in the mitral tri-leaflet valve 14.13 MPa, followed by the tricuspid aortic valve. The equivalent stresses for other types of valves produced with simple surface action were lower than 2 MPa. The strain energy that is expended during the process of diastole and systole was found to be directly proportional to the strength and flexibility of the materials used. The energy consumption rates decrease when using highly elastic materials such as TPE and PSN4. The values of this energy also increase with an increase in the area of the moving parts of the valve, especially when faced with the process of closing blood flow, as with the use of the tricuspid aortic valve (TAV). The highest total deformation resulted in the valve body when using TPU, followed by TPE, nylon, PETG, and PLA, while the lowest deformation rates were observed when using PSN4, which ranged from 5x105 to 0.1 mm, followed by SIBSTAR103 nanostructured rubber. The obtained values of stress safety factors were decreased with the complexity of the movement for the moving parts of the valve. The highest rates were recorded when using the tricuspid mitral valve, reaching 2.45 when using the high-strength and flexible PSN4 nanomaterial. It can be concluded that the best materials for manufacturing these four types of valves are the PSN4, followed by SIBSTAR103T, TPU, and TPE. The use of PETG, PLA, and nylon materials is not recommended for the manufacture of any prosthetic heart valves, due to their lack of strength, flexibility, and high brittleness, especially for PETG and PLA materials. It was also noted here that PSN4 is the only material suitable for the manufacture of mitral tri-leaflet and tricuspid mitral valve artificial valves. For other types of valves manufactured with a single leaflet, high safety stress factors were obtained because their movement is simple, flat, and in one direction, where the highest values were observed when testing a single hemispherical leaflet type valve, then the conical caged ball and the caged ball type, respectively.
- Open Access
- 6 December 2023
- Published by University of Technology, Iraq - DIGITAL COMMONS in Engineering and Technology Journal
- Vol. 41 (12) , 1552-1566
Comparison between the Effect of Adding MSGNP and B4C-WC Nanoparticles on the Metallurgical and Mechanical Characterization of Al-7075 Composites Produced by Stir Casting
Metal Matrix Composite (MCC) reveals considerably better properties, such as low density, high tensile strength, hardness, and good resistance to wear compared with every alloy or other metal. The current study concentrated upon the assessment of the properties of aluminum matrix composites (AMCs) synthesis with the Al-7075 as a matrix and the MSGNPs that sieved to (35 nm) at different weight fractions percentages as reinforcements using stir-casting method and compared with Al7075/B4C-WC nanocomposites. These experiments aim to select the appropriate type and percentage of reinforcement particles for producing Al-7075 composites with the best mechanical properties. The mechanical properties, as well as the metallurgical features for analyzing the microstructure and the distribution of (MSGNP, SiC-WC) into the composite alloy specimens, have been studied utilizing the mechanical tests and the Optical Microscopy (OM), Scanning Electron Microscope (SEM), Energy Dispersive Spectroscopy (EDS), and X-Ray Diffraction (XRD) SEM pictures. By reviewing the mechanical test results, they manifested that the value of the composite's ultimate strength was enhanced with the additive concentration of nanoglass. The maximum tensile strength was obtained for the sample comprising 4% MSGNP—the composite with 6 wt.% B4C and WC have the highest hardness value, which means the increase of the added composite material beyond 10% will decrease the hardness. The X-ray diffraction (XRD) examination results illustrate the various phases of the two-theta value-generated diffraction patterns for the Al-7075/MSGNP and Al-7075/B4C-WC workpieces materials. These examinations show that the matrix of Al and the clear glass are the two major composite constituents and contain B4C, WC, and aluminum matrix, which are consistent with what was shown by the optical microstructure of the composite. The Al-7075 microstructure analysis also demonstrated a virtuous metallic bonding between the particles of Al and the uniformly dispersed and transparent glass particles at the optimal addition of 8wt%. Such enhancement was ascribed to the reinforcement's sufficiency and the uniform dispersion of MSGNP. Therefore, the addition of 8 wt.% was chosen in the present work.
- 6 December 2023
- Published by University of Technology, Iraq - DIGITAL COMMONS in Engineering and Technology Journal
- Vol. 41 (12) , 1552-1566
Open AccessComparison between the Effect of Adding MSGNP and B4C-WC Nanoparticles on the Metallurgical and Mechanical Characterization of Al-7075 Composites Produced by Stir Casting
Metal Matrix Composite (MCC) reveals considerably better properties, such as low density, high tensile strength, hardness, and good resistance to wear compared with every alloy or other metal. The current study concentrated upon the assessment of the properties of aluminum matrix composites (AMCs) synthesis with the Al-7075 as a matrix and the MSGNPs that sieved to (35 nm) at different weight fractions percentages as reinforcements using stir-casting method and compared with Al7075/B4C-WC nanocomposites. These experiments aim to select the appropriate type and percentage of reinforcement particles for producing Al-7075 composites with the best mechanical properties. The mechanical properties, as well as the metallurgical features for analyzing the microstructure and the distribution of (MSGNP, SiC-WC) into the composite alloy specimens, have been studied utilizing the mechanical tests and the Optical Microscopy (OM), Scanning Electron Microscope (SEM), Energy Dispersive Spectroscopy (EDS), and X-Ray Diffraction (XRD) SEM pictures. By reviewing the mechanical test results, they manifested that the value of the composite's ultimate strength was enhanced with the additive concentration of nanoglass. The maximum tensile strength was obtained for the sample comprising 4% MSGNP—the composite with 6 wt.% B4C and WC have the highest hardness value, which means the increase of the added composite material beyond 10% will decrease the hardness. The X-ray diffraction (XRD) examination results illustrate the various phases of the two-theta value-generated diffraction patterns for the Al-7075/MSGNP and Al-7075/B4C-WC workpieces materials. These examinations show that the matrix of Al and the clear glass are the two major composite constituents and contain B4C, WC, and aluminum matrix, which are consistent with what was shown by the optical microstructure of the composite. The Al-7075 microstructure analysis also demonstrated a virtuous metallic bonding between the particles of Al and the uniformly dispersed and transparent glass particles at the optimal addition of 8wt%. Such enhancement was ascribed to the reinforcement's sufficiency and the uniform dispersion of MSGNP. Therefore, the addition of 8 wt.% was chosen in the present work.
- Open Access
- 4 August 2023
- Published by Universidad Nacional de Colombia in Ingeniería e Investigación
- Vol. 43 (3) , e98916
Design and Manufacturing of a Low-Cost Prosthetic Foot
Below-knee prosthetics are used to restore the functional activity and appearance of persons with lower limb amputation. This work attempted to design and manufacture a low-cost, novel, comfortable, lightweight, durable, and flexible smart below-knee foot prosthesis prototype. This prosthesis foot was designed according to the natural leg measurement of an adult male patient. The foot is composed of rigid PVC layers interspersed with elastic strips of PTFE, and the axis of the ankle joint is flexible and consists of metal layers and a composite of polymeric damping strips with different mechanical properties, making it flexible and allowing it to absorb shocks and store and release energy. The design, modeling, and simulation of the manufactured prosthetic foot were performed via the ANSYS 18.0 software and the finite element method (FEM), where a large number of parallel and oblique planes and sketches were created. This work included four adult patients weighing 50, 75, 90, and 120 kg with different walking cycles. The results show that the highest equivalent von Mises stress and total deformations for the prosthetic limb occur at the beginning of the walking step, while the highest equivalent elastic strains and strain energy release rates are observed at the end of the walking step, regardless of the weight. This prototype can satisfactorily perform the biomechanical functions of a natural human foot, and it can be produced in attractive sizes, models, and shapes to suit different levels of below-knee amputations for different ages and weights, especially for patients with limited income. Las prótesis debajo de la rodilla se utilizan para restaurar la actividad funcional y la apariencia de personas con amputación de miembros inferiores. Este trabajo intentó diseñar y fabricar un prototipo de prótesis de pie inteligente debajo de la rodilla, novedoso, cómodo, liviano, duradero, flexible y de bajo costo. Esta prótesis de pie fue diseñada según la medida natural de la pierna de un paciente masculino adulto. El pie está compuesto por capas rígidas de PVC intercaladas con tiras elásticas de PTFE, y el eje de la articulación del tobillo es flexible y está formado por capas metálicas y un compuesto de tiras amortiguadoras poliméricas con diferentes propiedades mecánicas, que la hacen flexible y le permiten absorber impactos y almacenar y liberar energía. El diseño, modelado y simulación de la prótesis de pie fabricada se realizó mediante el software ANSYS 18.0 y el método de elementos finitos (FEM), donde se crearon una gran cantidad de planos y bocetos paralelos y oblicuos. Este trabajo incluyó a cuatro pacientes adultos que pesaban 50, 75, 90 y 120 kg con diferentes ciclos de caminata. Los resultados muestran que la tensión de von Mises equivalente más alta y las deformaciones totales para la extremidad protésica ocurren al comienzo del paso de caminar, mientras que las deformaciones elásticas equivalentes y las tasas de liberación de energía de deformación más altas se observan al final del paso de caminar, independientemente del peso. Este prototipo puede realizar satisfactoriamente las funciones biomecánicas de un pie humano natural y puede producirse en tamaños, modelos y formas atractivos para adaptarse a diferentes niveles de amputaciones por debajo de la rodilla para diferentes edades y pesos, especialmente para pacientes con ingresos limitados.
- 4 August 2023
- Published by Universidad Nacional de Colombia in Ingeniería e Investigación
- Vol. 43 (3) , e98916
Open AccessDesign and Manufacturing of a Low-Cost Prosthetic Foot
Below-knee prosthetics are used to restore the functional activity and appearance of persons with lower limb amputation. This work attempted to design and manufacture a low-cost, novel, comfortable, lightweight, durable, and flexible smart below-knee foot prosthesis prototype. This prosthesis foot was designed according to the natural leg measurement of an adult male patient. The foot is composed of rigid PVC layers interspersed with elastic strips of PTFE, and the axis of the ankle joint is flexible and consists of metal layers and a composite of polymeric damping strips with different mechanical properties, making it flexible and allowing it to absorb shocks and store and release energy. The design, modeling, and simulation of the manufactured prosthetic foot were performed via the ANSYS 18.0 software and the finite element method (FEM), where a large number of parallel and oblique planes and sketches were created. This work included four adult patients weighing 50, 75, 90, and 120 kg with different walking cycles. The results show that the highest equivalent von Mises stress and total deformations for the prosthetic limb occur at the beginning of the walking step, while the highest equivalent elastic strains and strain energy release rates are observed at the end of the walking step, regardless of the weight. This prototype can satisfactorily perform the biomechanical functions of a natural human foot, and it can be produced in attractive sizes, models, and shapes to suit different levels of below-knee amputations for different ages and weights, especially for patients with limited income. Las prótesis debajo de la rodilla se utilizan para restaurar la actividad funcional y la apariencia de personas con amputación de miembros inferiores. Este trabajo intentó diseñar y fabricar un prototipo de prótesis de pie inteligente debajo de la rodilla, novedoso, cómodo, liviano, duradero, flexible y de bajo costo. Esta prótesis de pie fue diseñada según la medida natural de la pierna de un paciente masculino adulto. El pie está compuesto por capas rígidas de PVC intercaladas con tiras elásticas de PTFE, y el eje de la articulación del tobillo es flexible y está formado por capas metálicas y un compuesto de tiras amortiguadoras poliméricas con diferentes propiedades mecánicas, que la hacen flexible y le permiten absorber impactos y almacenar y liberar energía. El diseño, modelado y simulación de la prótesis de pie fabricada se realizó mediante el software ANSYS 18.0 y el método de elementos finitos (FEM), donde se crearon una gran cantidad de planos y bocetos paralelos y oblicuos. Este trabajo incluyó a cuatro pacientes adultos que pesaban 50, 75, 90 y 120 kg con diferentes ciclos de caminata. Los resultados muestran que la tensión de von Mises equivalente más alta y las deformaciones totales para la extremidad protésica ocurren al comienzo del paso de caminar, mientras que las deformaciones elásticas equivalentes y las tasas de liberación de energía de deformación más altas se observan al final del paso de caminar, independientemente del peso. Este prototipo puede realizar satisfactoriamente las funciones biomecánicas de un pie humano natural y puede producirse en tamaños, modelos y formas atractivos para adaptarse a diferentes niveles de amputaciones por debajo de la rodilla para diferentes edades y pesos, especialmente para pacientes con ingresos limitados.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2977 (1) , 020059
Design and implementation of an electrical muscle stimulator for clinically and physical treatment application
The purpose of electrical stimulation is to take advantage of the physiological effects of electrical current on muscles to strengthen muscles, delay muscle atr
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2977 (1) , 020059
Open AccessDesign and implementation of an electrical muscle stimulator for clinically and physical treatment application
The purpose of electrical stimulation is to take advantage of the physiological effects of electrical current on muscles to strengthen muscles, delay muscle atr
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2977 (1)
Design and modeling of a lower artificial limb adjustable socket
Amputation is always considered a major health problem that causes panic and leads to body disfigurement and changes in the life and activity of amputees and their independence. The process of adaptation with prosthetic limbs is a major problem in the field of rehabilitation. Not only does it require extra effort from the patient to adapt to a new condition in terms of movement and balance, but it is also not easy to get a perfect fit between the socket and the amputated tip. The present work aims to design and manufacture a low-cost, lightweight, flexible, and highly efficient regulated lower limb prosthesis socket for a 22-year-old male weighing 78 kg. The socket recess on the leg of the amputee patient can be adjusted to be comfortable, flexible, and integrated with the details of the amputation area. The socket was designed and manufactured with the characteristics of rapid and continuous regulation to ensure a tight fit of the socket with the amputated limb. It enables the patient to quickly adapt and to ensure patient comfort during normal daily activities as well as during wearing and removing the prosthesis where the dimensions and size of the amputated leg of the patient change after the prosthesis was installed due to dynamic loads to which it was subjected. The pneumatic control system consists of the manufactured socket, the mechanism for controlling air pressure and the system of air gates were designed to adjust the socket to work with a number of mechanical stresses with variable directions to ensure the best fixation of the prosthesis, the highest comfort and to restore a large part of the daily activities lost by patients of different ages, weights, and levels of amputation in their lower limbs.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2977 (1)
Design and modeling of a lower artificial limb adjustable socket
Amputation is always considered a major health problem that causes panic and leads to body disfigurement and changes in the life and activity of amputees and their independence. The process of adaptation with prosthetic limbs is a major problem in the field of rehabilitation. Not only does it require extra effort from the patient to adapt to a new condition in terms of movement and balance, but it is also not easy to get a perfect fit between the socket and the amputated tip. The present work aims to design and manufacture a low-cost, lightweight, flexible, and highly efficient regulated lower limb prosthesis socket for a 22-year-old male weighing 78 kg. The socket recess on the leg of the amputee patient can be adjusted to be comfortable, flexible, and integrated with the details of the amputation area. The socket was designed and manufactured with the characteristics of rapid and continuous regulation to ensure a tight fit of the socket with the amputated limb. It enables the patient to quickly adapt and to ensure patient comfort during normal daily activities as well as during wearing and removing the prosthesis where the dimensions and size of the amputated leg of the patient change after the prosthesis was installed due to dynamic loads to which it was subjected. The pneumatic control system consists of the manufactured socket, the mechanism for controlling air pressure and the system of air gates were designed to adjust the socket to work with a number of mechanical stresses with variable directions to ensure the best fixation of the prosthesis, the highest comfort and to restore a large part of the daily activities lost by patients of different ages, weights, and levels of amputation in their lower limbs.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2977 (1) , 020060
Design and fabricating of continuous passive motion (CPM) machine for physical knee pain therapy
Diseases of the human musculoskeletal system are increasingly common, especially those affecting the knee joint, for various reasons, including those that resul
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2977 (1) , 020060
Design and fabricating of continuous passive motion (CPM) machine for physical knee pain therapy
Diseases of the human musculoskeletal system are increasingly common, especially those affecting the knee joint, for various reasons, including those that resul
- 20 July 2021
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1039, 182-200
The Effect of Electrical Discharge Machining Total Heat Generated on White Layer Thickness (WLT) and Fatigue Life for Die Steel
The present paper concerns with studying the high complexity nature of the EDM multiple discharge analysis transformed into a feasible solvable mathematical model for the die steel workpiece type AISI D2, the copper and graphite materials electrodes, and the kerosene dielectric by setting the Transient Thermal and the Multiphysics analyses domain loads models using the ANSYS 15.0 finite element analysis. Two load steps modeled the entering setting time analysis, six sub-periods setting time cycle, four heating, and two cooling periods, six transient temperature values, and four transient thermal convection models. The radius spark (discharge channel), the total number of discharges sparks, the total heat power generation, the absorbed heat flux fractions by the electrodes, the workpieces and kerosene fluid dielectric, the heat-affected zones (HAZ), the hard white recast layer thickness (WLT) and properties, the workpiece fatigue safety factor and life after EDM machining were determined and simulated. The thermal model errors compared with theoretical calculations and a modeled predicted equation were also deduced and verified. The experimental results evinced that the maximum total heat flux generated using the graphite material electrodes is (2.619E+009 W/m2) which is higher than when using copper material electrodes by (82.4%), while the minimum value of the white layer thickness (WLT) after EDM machining using graphite tool electrodes is (8.34 μm), which it gives an improvement comparing with using of copper tool electrodes by (40.0%). The macrographic and microstructure evaluation manifest that the discharge spark craters sizes when using graphite tool electrodes reached their sizes. The maximum fatigue stresses and fatigue safety factor when using copper tool electrodes are (240 MPa) and (0.89) which is higher by a value of (3.35%) and (3.45%) comparing with the using of graphite electrodes, respectively.
- 20 July 2021
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1039, 182-200
The Effect of Electrical Discharge Machining Total Heat Generated on White Layer Thickness (WLT) and Fatigue Life for Die Steel
The present paper concerns with studying the high complexity nature of the EDM multiple discharge analysis transformed into a feasible solvable mathematical model for the die steel workpiece type AISI D2, the copper and graphite materials electrodes, and the kerosene dielectric by setting the Transient Thermal and the Multiphysics analyses domain loads models using the ANSYS 15.0 finite element analysis. Two load steps modeled the entering setting time analysis, six sub-periods setting time cycle, four heating, and two cooling periods, six transient temperature values, and four transient thermal convection models. The radius spark (discharge channel), the total number of discharges sparks, the total heat power generation, the absorbed heat flux fractions by the electrodes, the workpieces and kerosene fluid dielectric, the heat-affected zones (HAZ), the hard white recast layer thickness (WLT) and properties, the workpiece fatigue safety factor and life after EDM machining were determined and simulated. The thermal model errors compared with theoretical calculations and a modeled predicted equation were also deduced and verified. The experimental results evinced that the maximum total heat flux generated using the graphite material electrodes is (2.619E+009 W/m2) which is higher than when using copper material electrodes by (82.4%), while the minimum value of the white layer thickness (WLT) after EDM machining using graphite tool electrodes is (8.34 μm), which it gives an improvement comparing with using of copper tool electrodes by (40.0%). The macrographic and microstructure evaluation manifest that the discharge spark craters sizes when using graphite tool electrodes reached their sizes. The maximum fatigue stresses and fatigue safety factor when using copper tool electrodes are (240 MPa) and (0.89) which is higher by a value of (3.35%) and (3.45%) comparing with the using of graphite electrodes, respectively.