Yigit Yazicioglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yigit Yazicioglu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Thomas J. Royston
University of Illinois Chicago, Chicago, IL, 60607, USA
5 shared publications - Afsar Saranli
Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara, Turkey
2 shared publications Bryn Martin
Univ. of Illinois at Chicago, 842 W. Taylor St. MC 251, Chicago, IL 60607
2 shared publications- Cuneyt Sert
Orta Doğu Teknik Üniversitesi
2 shared publications - Francis Loth
Department of Mechanical and Industrial Engineering and Department of Bioengineering, University of Illinois at Chicago, 842 W. Taylor, Chicago, IL 60607, USA
2 shared publications - Francis Loth
Department of Mechanical and Industrial Engineering and Bioengineering, Northeastern University, Boston, MA 02115 USA
2 shared publications
Latest Publications
- Open Access
- 8 May 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (5) , 328
Dynamics and Control of a Novel Hybrid Legged Robot with Temporary Flight Capabilities
In this study, a novel flying legged robot configuration with enhanced obstacle-crossing capability is introduced. Legged robots, especially RHex robots, already possess high obstacle-crossing capability; however, the obstacle size that can be overcome is directly dependent on the leg length. Although stair climbing–descending, obstacle course and inclined surface algorithms have been studied for the RHex robot, flight capability has not been explored. In this study, this improvement is achieved with minimal impact on the RHex’s design by adding just a thruster as an additional propulsion system to propel the robot into flight. The attitude control is realized using the mass actuation of the robot legs, similar to how animals like lizards and cats utilize their limbs or tails as inertial appendages to stabilize their body pitch during mid-air maneuvers. Instead of direct and complete flight control, the aim was a temporary flight similar to obstacle-clearing flights of chickens. Hence, a nonlinear 2D model is developed to investigate the kinematics and dynamics of the RHex robot. Equations of motion are derived, linearized and used in a state feedback regulator design; the regulator is also expanded for reference tracking.
- 8 May 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (5) , 328
Open AccessDynamics and Control of a Novel Hybrid Legged Robot with Temporary Flight Capabilities
In this study, a novel flying legged robot configuration with enhanced obstacle-crossing capability is introduced. Legged robots, especially RHex robots, already possess high obstacle-crossing capability; however, the obstacle size that can be overcome is directly dependent on the leg length. Although stair climbing–descending, obstacle course and inclined surface algorithms have been studied for the RHex robot, flight capability has not been explored. In this study, this improvement is achieved with minimal impact on the RHex’s design by adding just a thruster as an additional propulsion system to propel the robot into flight. The attitude control is realized using the mass actuation of the robot legs, similar to how animals like lizards and cats utilize their limbs or tails as inertial appendages to stabilize their body pitch during mid-air maneuvers. Instead of direct and complete flight control, the aim was a temporary flight similar to obstacle-clearing flights of chickens. Hence, a nonlinear 2D model is developed to investigate the kinematics and dynamics of the RHex robot. Equations of motion are derived, linearized and used in a state feedback regulator design; the regulator is also expanded for reference tracking.
- 1 September 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 208, 106253
Simulation of turbulence induced sound generation inside stenosed femoral artery models with different severities and eccentricities
- 1 September 2021
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 208, 106253
Simulation of turbulence induced sound generation inside stenosed femoral artery models with different severities and eccentricities
- Open Access
- 7 February 2020
- Published by Copernicus GmbH in Mechanical Sciences
- Vol. 11 (1) , 29-38
On the analysis and design of a fully compliant large stroke slider-crank (rocker) mechanism
In the literature, authors have made contributions in the area of partially compliant slider-crank (rocker) mechanisms possessing rigid joints that may cause backlash inherently. On contrary, fully compliant mechanisms offer no backlash which is a valuable property for the cases where high precision is required. In this paper, we proposed a fully compliant slider-crank mechanism that performs large stroke. Kinematic performance of the mechanism is investigated analytically. Dimensions of the mechanism are optimized to obtain maximum translational output, while keeping deflections of flexible hinges equal to each other and as small as possible. A design table displaying stroke, axis drift of the output segment, and critical stresses of compliant segments are presented. As an example, a compliant mechanism is designed by using rigid body replacement technique. Then, via nonlinear finite element analysis technique, analytical results are verified. Finally, a prototype is built to compare output stroke and axis drift with analytical approaches. The results of experiments verified that the theoretical approaches are consistent.
- 7 February 2020
- Published by Copernicus GmbH in Mechanical Sciences
- Vol. 11 (1) , 29-38
Open AccessOn the analysis and design of a fully compliant large stroke slider-crank (rocker) mechanism
In the literature, authors have made contributions in the area of partially compliant slider-crank (rocker) mechanisms possessing rigid joints that may cause backlash inherently. On contrary, fully compliant mechanisms offer no backlash which is a valuable property for the cases where high precision is required. In this paper, we proposed a fully compliant slider-crank mechanism that performs large stroke. Kinematic performance of the mechanism is investigated analytically. Dimensions of the mechanism are optimized to obtain maximum translational output, while keeping deflections of flexible hinges equal to each other and as small as possible. A design table displaying stroke, axis drift of the output segment, and critical stresses of compliant segments are presented. As an example, a compliant mechanism is designed by using rigid body replacement technique. Then, via nonlinear finite element analysis technique, analytical results are verified. Finally, a prototype is built to compare output stroke and axis drift with analytical approaches. The results of experiments verified that the theoretical approaches are consistent.
- 14 January 2020
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 58 (3) , 643-658
Effect of stenosis shape on the sound emitted from a constricted blood vessel
Effect of stenosis shape on the post-stenotic pressure fluctuations and the sound emitted from a constricted blood vessel is studied numerically. Large eddy simulations are performed using OpenFOAM under pulsatile flow conditions with a non-Newtonian fluid model. Findings indicate that the high slope at the stenosis entrance and overlap of more than one stenosis shorten the length of the flow jet, trigger turbulence, and increase vortical activity, turbulent kinetic energy, and magnitude of pressure fluctuations at the post-stenotic region. Also, these morphological parameters strengthen the audible signal especially in the systolic phase of the pulsatile flow. On the other hand, asymmetry of the stenosis creates an opposite effect. Based on the wall pressure data, it is shown that the stenosis shape affects the intensity and the pattern of the murmurs generated. Stenosis shape is found to be an essential factor for the acoustic-based non-invasive diagnosis of stenosis.
- 14 January 2020
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 58 (3) , 643-658
Effect of stenosis shape on the sound emitted from a constricted blood vessel
Effect of stenosis shape on the post-stenotic pressure fluctuations and the sound emitted from a constricted blood vessel is studied numerically. Large eddy simulations are performed using OpenFOAM under pulsatile flow conditions with a non-Newtonian fluid model. Findings indicate that the high slope at the stenosis entrance and overlap of more than one stenosis shorten the length of the flow jet, trigger turbulence, and increase vortical activity, turbulent kinetic energy, and magnitude of pressure fluctuations at the post-stenotic region. Also, these morphological parameters strengthen the audible signal especially in the systolic phase of the pulsatile flow. On the other hand, asymmetry of the stenosis creates an opposite effect. Based on the wall pressure data, it is shown that the stenosis shape affects the intensity and the pattern of the murmurs generated. Stenosis shape is found to be an essential factor for the acoustic-based non-invasive diagnosis of stenosis.
- 20 June 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 70 (1) , 39-50
Computational analysis for non-invasive detection of stenosis in peripheral arteries
Atherosclerosis usually affects the entire cardiovascular system, including peripheral blood vessels. Peripheral arterial stenosis may indicate possible serious vascular disorders related to more vital organs. If peripheral arterial stenosis can be discerned at an early stage, it can serve as a warning sign to take precautions, such as using more invasive diagnostic techniques or adopting a healthier life style. In this study, peripheral regions, such as the thigh, upper arm, and neck are modelled considering stenosis of their major arteries. Stenosis generates a fluctuating pressure field on the arterial wall, which leads to vibration on the skin's surface. This stenosis-induced pressure field is modelled as a harmonic load and applied to the inner surface of the arterial structure. The vibration response on bare skin is computationally determined using the superposition of modal responses. Realistic geometries and hyperelastic material properties are used in modelling the layers of skin, fat, muscle, and bones. The results indicate that stenosis severities higher than 70% lead to a considerable increase in vibration-response amplitudes, especially at frequencies greater than 250 Hz. The detailed analysis of skin responses provides useful information to detect the stenosis location, where the sum of the vibration amplitudes attains its maximum value around the stenosis.
- 20 June 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 70 (1) , 39-50
Computational analysis for non-invasive detection of stenosis in peripheral arteries
Atherosclerosis usually affects the entire cardiovascular system, including peripheral blood vessels. Peripheral arterial stenosis may indicate possible serious vascular disorders related to more vital organs. If peripheral arterial stenosis can be discerned at an early stage, it can serve as a warning sign to take precautions, such as using more invasive diagnostic techniques or adopting a healthier life style. In this study, peripheral regions, such as the thigh, upper arm, and neck are modelled considering stenosis of their major arteries. Stenosis generates a fluctuating pressure field on the arterial wall, which leads to vibration on the skin's surface. This stenosis-induced pressure field is modelled as a harmonic load and applied to the inner surface of the arterial structure. The vibration response on bare skin is computationally determined using the superposition of modal responses. Realistic geometries and hyperelastic material properties are used in modelling the layers of skin, fat, muscle, and bones. The results indicate that stenosis severities higher than 70% lead to a considerable increase in vibration-response amplitudes, especially at frequencies greater than 250 Hz. The detailed analysis of skin responses provides useful information to detect the stenosis location, where the sum of the vibration amplitudes attains its maximum value around the stenosis.
- 8 June 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (8) , 1737-1752
Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration
Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibility of noninvasive acoustic detection of the peripheral arterial stenosis is investigated using the vibration responses by means of experimental and computational models. Latex rubber tube is used to model the artery, and it is surrounded by a tissue mimicking phantom made of bovine gelatin. Vibration responses on phantom surface are measured using laser Doppler vibrometer, and computational results are obtained performing modal analysis. Experimental findings and computational results showed well agreement in terms of spectral content and vibration amplitudes. The effects of various stenosis severities, flow rates, and phantom thicknesses on the vibration responses are investigated from diagnostic perspective. Stenosis severities greater than 70% resulted in a considerable increase in vibration amplitudes. The structural mode shapes of the tissue phantom are dominant between 0 and 100 Hz, suppressing the signals generated by the stenosis. The optimum range of frequency for acoustic stenosis detection is concluded to be between 200 and 500 Hz, particularly around 300 Hz.
- 8 June 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (8) , 1737-1752
Experimental and numerical investigation on soft tissue dynamic response due to turbulence-induced arterial vibration
Peripheral arterial occlusive disease is a serious cardiovascular disorder. The arterial occlusion leads to turbulent flow and arterial sound generation on the inner vessel wall. Stenosis-induced vibro-acoustic waves propagate through the surrounding soft tissues and reach the skin surface. In this study, the feasibility of noninvasive acoustic detection of the peripheral arterial stenosis is investigated using the vibration responses by means of experimental and computational models. Latex rubber tube is used to model the artery, and it is surrounded by a tissue mimicking phantom made of bovine gelatin. Vibration responses on phantom surface are measured using laser Doppler vibrometer, and computational results are obtained performing modal analysis. Experimental findings and computational results showed well agreement in terms of spectral content and vibration amplitudes. The effects of various stenosis severities, flow rates, and phantom thicknesses on the vibration responses are investigated from diagnostic perspective. Stenosis severities greater than 70% resulted in a considerable increase in vibration amplitudes. The structural mode shapes of the tissue phantom are dominant between 0 and 100 Hz, suppressing the signals generated by the stenosis. The optimum range of frequency for acoustic stenosis detection is concluded to be between 200 and 500 Hz, particularly around 300 Hz.
- Open Access
- 1 January 2019
- Published by Wiley in Shock and Vibration
- Vol. 2019 (1)
Minimization of Ground Vibration Test Configurations for F‐16 Aircraft by Subtractive Modification
The certification process of external loads designed for aircraft needs to satisfy various criteria where compatibility with existing systems is one of the essential requirements. Flight flutter testing is a critical part of a certification process that requires many preliminary studies. Computational flutter analysis must precede actual flutter test to determine an approximately safe flight envelope to ensure the safety of the personnel and aircraft. To be able to perform flutter analysis of an aircraft, an accurate structural model such as finite element (FE) model is required. An accurate FE model can be obtained from a coarse model using ground vibration test (GVT) which is also the primary test campaign for certification of a new external load, new aircraft design, or modification on existing aircraft. On the other hand, performing GVT for each configuration of an aircraft is both time consuming and costly. It would be more practical to determine the critical configurations for an aircraft using computational tools and perform actual GVT for those configurations. The objective of this study is to simulate GVT characteristics for downloading and fuel configurations of F‐16 aircraft. A novel methodology is proposed where various loading configurations can be simulated by subtractive modification from loaded GVT data so that joint stiffnesses between stores and aircraft need not be identified. The proposed technique decreases the number of necessary physical GVT testing campaigns.
- 1 January 2019
- Published by Wiley in Shock and Vibration
- Vol. 2019 (1)
Open AccessMinimization of Ground Vibration Test Configurations for F‐16 Aircraft by Subtractive Modification
The certification process of external loads designed for aircraft needs to satisfy various criteria where compatibility with existing systems is one of the essential requirements. Flight flutter testing is a critical part of a certification process that requires many preliminary studies. Computational flutter analysis must precede actual flutter test to determine an approximately safe flight envelope to ensure the safety of the personnel and aircraft. To be able to perform flutter analysis of an aircraft, an accurate structural model such as finite element (FE) model is required. An accurate FE model can be obtained from a coarse model using ground vibration test (GVT) which is also the primary test campaign for certification of a new external load, new aircraft design, or modification on existing aircraft. On the other hand, performing GVT for each configuration of an aircraft is both time consuming and costly. It would be more practical to determine the critical configurations for an aircraft using computational tools and perform actual GVT for those configurations. The objective of this study is to simulate GVT characteristics for downloading and fuel configurations of F‐16 aircraft. A novel methodology is proposed where various loading configurations can be simulated by subtractive modification from loaded GVT data so that joint stiffnesses between stores and aircraft need not be identified. The proposed technique decreases the number of necessary physical GVT testing campaigns.
- 1 January 2015
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 25 (1) , 020001
Investigation of on skin surface response due to acoustic radiation from stenosed blood vessels
Arterial stenosis is a form of cardiovascular disease which leads to highest rate of fatalities worldwide. When stenosis is present in coronary arteries, it leads to heart attack and often sudden death. Arterial disease is usually not confined to critical organs such as the heart and the brain but observed throughout the peripheral cardiovascular system. When an artery has a diameter reduction, acoustic radiation originating from this constriction propagates through soft tissues and reaches to skin surface. Therefore, these signals detected on skin surface may provide valuable information for diagnostic purposes. In this study, effects of acoustic radiation on skin surface due to a stenosis are investigated. Human upper arm is modeled using commercial finite element analysis software ADINA. Realistic geometries and soft tissue mechanical properties are employed. Acoustic pressure distribution due to constriction is modeled using related studies in literature and applied on inner surface of blood vessel. Harmonic analysis is performed for upper arm and pressure distribution on skin surface is obtained. It is observed that increasing level of stenosis leads to an increase in pressure amplitudes on skin surface where the region which is closest to the constricted artery has the highest pressure amplitudes.
- 1 January 2015
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 25 (1) , 020001
Investigation of on skin surface response due to acoustic radiation from stenosed blood vessels
Arterial stenosis is a form of cardiovascular disease which leads to highest rate of fatalities worldwide. When stenosis is present in coronary arteries, it leads to heart attack and often sudden death. Arterial disease is usually not confined to critical organs such as the heart and the brain but observed throughout the peripheral cardiovascular system. When an artery has a diameter reduction, acoustic radiation originating from this constriction propagates through soft tissues and reaches to skin surface. Therefore, these signals detected on skin surface may provide valuable information for diagnostic purposes. In this study, effects of acoustic radiation on skin surface due to a stenosis are investigated. Human upper arm is modeled using commercial finite element analysis software ADINA. Realistic geometries and soft tissue mechanical properties are employed. Acoustic pressure distribution due to constriction is modeled using related studies in literature and applied on inner surface of blood vessel. Harmonic analysis is performed for upper arm and pressure distribution on skin surface is obtained. It is observed that increasing level of stenosis leads to an increase in pressure amplitudes on skin surface where the region which is closest to the constricted artery has the highest pressure amplitudes.
- 1 December 2014
- Published by Elsevier in Control Engineering Practice
- Vol. 33, 10-21
Optimal control of a half-circular compliant legged monopod
- 1 December 2014
- Published by Elsevier in Control Engineering Practice
- Vol. 33, 10-21
Optimal control of a half-circular compliant legged monopod
- 1 March 2014
- Published by Elsevier in Journal of Computational and Applied Mathematics
- Vol. 259, 955-964
Lagrangian based mathematical modeling and experimental validation of a planar stabilized platform for mobile systems
- 1 March 2014
- Published by Elsevier in Journal of Computational and Applied Mathematics
- Vol. 259, 955-964
Lagrangian based mathematical modeling and experimental validation of a planar stabilized platform for mobile systems