Karin Markenroth Bloch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Karin Markenroth Bloch has a total of 432 co-authors. Here are the top co-authors by number of shared publications:
- Bjorn Jonson
Chalmers Tekniska Högskola
14 shared publications K. Riisager
14 shared publications- Thomas Nilsson
Institutionen för Fysik, Chalmers Tekniska Högskola, Göteborg, Sweden
13 shared publications H. Simon
11 shared publicationsG. Schrieder
10 shared publicationsH. Geissel
10 shared publications
Latest Publications
- Open Access
- 19 November 2025
- Published by Taylor & Francis in LEUKOS
- Vol. 23 (1) , 99-115
Temporal Light Modulation Activation in Visual Cortex – A 7T fMRI Study on Healthy Subjects
- 19 November 2025
- Published by Taylor & Francis in LEUKOS
- Vol. 23 (1) , 99-115
Open AccessTemporal Light Modulation Activation in Visual Cortex – A 7T fMRI Study on Healthy Subjects
- Open Access
- 17 April 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70041
High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing
This study aimed to obtain high‐resolution 3D isotropic turbo spin‐echo (TSE) wrist MRI acquisitions at 7T, with and without fat suppression, facilitated by compressed‐sensing (CS) acceleration. In 16 healthy subjects, fat‐suppressed (FS) and nonfat‐suppressed (NFS) TSE wrist images were obtained. The protocol consisted of a SENSE‐accelerated scan, with an isotropic voxel size of 0.45 mm and acquisition time of 7 min (“SENSE45”), a 0.45‐mm, 4‐min CS‐accelerated scan (“CS45”), and a 0.35‐mm, 7‐min CS‐accelerated scan (“CS35”). For two subjects, additional 0.45‐mm, 4‐min SENSE‐accelerated scans were acquired (“High‐SENSE”). For the NFS scans, refocusing pulses were optimized to mitigate water‐fat chemical‐shift artifacts in the slab‐selection direction. Anatomical visibility of wrist structures and image quality were assessed qualitatively and through musculoskeletal radiologist grading. The use of nonselective hard refocusing pulses with optimized bandwidths and a center frequency in between water and fat enabled NFS imaging. The image quality of the faster CS45 scans was lower than for SENSE45, with statistically significantly different grading in 9/16 (FS) and 2/6 (NFS) grading parameters. Nonetheless, a similar scan time reduction could not be achieved using High‐SENSE. No distinct benefit of CS35 compared to SENSE45 was evident in either the FS or NFS scans. NFS CS35 exhibited enhanced bone sharpness compared to SENSE45 for some subjects, yet on a group level, the difference was not statistically significant. In conclusion, for maintained voxel size, CS presents the opportunity to achieve shorter scan times than possible with SENSE alone, but with reduced image quality. For maintained scan time, although higher resolution CS incidentally showed a promising increase in NFS bone sharpness compared to SENSE, it does not present an unequivocal advantage for 3D 7‐T TSE wrist MRI at this stage. Further optimization of the acquisition and reconstruction process is recommended.
- 17 April 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70041
Open AccessHigh‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing
This study aimed to obtain high‐resolution 3D isotropic turbo spin‐echo (TSE) wrist MRI acquisitions at 7T, with and without fat suppression, facilitated by compressed‐sensing (CS) acceleration. In 16 healthy subjects, fat‐suppressed (FS) and nonfat‐suppressed (NFS) TSE wrist images were obtained. The protocol consisted of a SENSE‐accelerated scan, with an isotropic voxel size of 0.45 mm and acquisition time of 7 min (“SENSE45”), a 0.45‐mm, 4‐min CS‐accelerated scan (“CS45”), and a 0.35‐mm, 7‐min CS‐accelerated scan (“CS35”). For two subjects, additional 0.45‐mm, 4‐min SENSE‐accelerated scans were acquired (“High‐SENSE”). For the NFS scans, refocusing pulses were optimized to mitigate water‐fat chemical‐shift artifacts in the slab‐selection direction. Anatomical visibility of wrist structures and image quality were assessed qualitatively and through musculoskeletal radiologist grading. The use of nonselective hard refocusing pulses with optimized bandwidths and a center frequency in between water and fat enabled NFS imaging. The image quality of the faster CS45 scans was lower than for SENSE45, with statistically significantly different grading in 9/16 (FS) and 2/6 (NFS) grading parameters. Nonetheless, a similar scan time reduction could not be achieved using High‐SENSE. No distinct benefit of CS35 compared to SENSE45 was evident in either the FS or NFS scans. NFS CS35 exhibited enhanced bone sharpness compared to SENSE45 for some subjects, yet on a group level, the difference was not statistically significant. In conclusion, for maintained voxel size, CS presents the opportunity to achieve shorter scan times than possible with SENSE alone, but with reduced image quality. For maintained scan time, although higher resolution CS incidentally showed a promising increase in NFS bone sharpness compared to SENSE, it does not present an unequivocal advantage for 3D 7‐T TSE wrist MRI at this stage. Further optimization of the acquisition and reconstruction process is recommended.
- 23 October 2023
- Published by Elsevier in Radiography
- Vol. 30 (1) , 95-99
Effects of ultra-high field MRI environment on cognitive performance in healthy participants
- 23 October 2023
- Published by Elsevier in Radiography
- Vol. 30 (1) , 95-99
Effects of ultra-high field MRI environment on cognitive performance in healthy participants
- 13 June 2023
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 32 (3) , 986-989
7T magnetic resonance angiographic imaging of basilar artery perforator aneurysms – initial experience of a non-invasive alternative to DSA
Background: Perforator aneurysms of the basilar artery (PABA) are rare causes of subarachnoid haemorrhage (SAH) and challenging to diagnose. We present two cases of SAH caused by PABA diagnosed by cone beam computed tomography angiography (CBCTA) and a novel non-invasive method – 7T magnetic resonance imaging (7T MRI). Methods: Two patients with SAH, diagnosed with PABA, were imaged on day 9 and 13 after onset, respectively, with CBCTA and 7T MR angiography (MRA) performed on the day after and at follow-up at 3 months. Results: All four 7T MRI examinations in the two patients were technically successful with fully diagnostic images. No endovascular treatment was performed and control with 7T MRA at 3 months showed no remaining aneurysms. Conclusion: PABA can be imaged with 7T MRI – a novel non-invasive method, allowing non-invasive follow-up to monitor this rare cause of SAH.
- 13 June 2023
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 32 (3) , 986-989
7T magnetic resonance angiographic imaging of basilar artery perforator aneurysms – initial experience of a non-invasive alternative to DSA
Background: Perforator aneurysms of the basilar artery (PABA) are rare causes of subarachnoid haemorrhage (SAH) and challenging to diagnose. We present two cases of SAH caused by PABA diagnosed by cone beam computed tomography angiography (CBCTA) and a novel non-invasive method – 7T magnetic resonance imaging (7T MRI). Methods: Two patients with SAH, diagnosed with PABA, were imaged on day 9 and 13 after onset, respectively, with CBCTA and 7T MR angiography (MRA) performed on the day after and at follow-up at 3 months. Results: All four 7T MRI examinations in the two patients were technically successful with fully diagnostic images. No endovascular treatment was performed and control with 7T MRA at 3 months showed no remaining aneurysms. Conclusion: PABA can be imaged with 7T MRI – a novel non-invasive method, allowing non-invasive follow-up to monitor this rare cause of SAH.
- Open Access
- 20 November 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (6) , e4863
Tissue response curve‐shape analysis of dynamic glucose‐enhanced and dynamic contrast‐enhanced magnetic resonance imaging in patients with brain tumor
Dynamic glucose‐enhanced (DGE) MRI is used to study the signal intensity time course (tissue response curve) after D‐glucose injection. D‐glucose has potential as a biodegradable alternative or complement to gadolinium‐based contrast agents, with DGE being comparable with dynamic contrast‐enhanced (DCE) MRI. However, the tissue uptake kinetics as well as the detection methods of DGE differ from DCE MRI, and it is relevant to compare these techniques in terms of spatiotemporal enhancement patterns. This study aims to develop a DGE analysis method based on tissue response curve shapes, and to investigate whether DGE MRI provides similar or complementary information to DCE MRI. Eleven patients with suspected gliomas were studied. Tissue response curves were measured for DGE and DCE MRI at 7 T and the area under the curve (AUC) was assessed. Seven types of response curve shapes were postulated and subsequently identified by deep learning to create color‐coded “curve maps” showing the spatial distribution of different curve types. DGE AUC values were significantly higher in lesions than in normal tissue (p < 0.007). Furthermore, the distribution of curve types differed between lesions and normal tissue for both DGE and DCE. The DGE and DCE response curves in a 6‐min postinjection time interval were classified as the same curve type in 20% of the lesion voxels, which increased to 29% when a 12‐min DGE time interval was considered. While both DGE and DCE tissue response curve‐shape analysis enabled differentiation of lesions from normal brain tissue in humans, their enhancements were neither temporally identical nor confined entirely to the same regions. Curve maps can provide accessible and intuitive information about the shape of DGE response curves, which is expected to be useful in the continued work towards the interpretation of DGE uptake curves in terms of D‐glucose delivery, transport, and metabolism.
- 20 November 2022
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (6) , e4863
Open AccessTissue response curve‐shape analysis of dynamic glucose‐enhanced and dynamic contrast‐enhanced magnetic resonance imaging in patients with brain tumor
Dynamic glucose‐enhanced (DGE) MRI is used to study the signal intensity time course (tissue response curve) after D‐glucose injection. D‐glucose has potential as a biodegradable alternative or complement to gadolinium‐based contrast agents, with DGE being comparable with dynamic contrast‐enhanced (DCE) MRI. However, the tissue uptake kinetics as well as the detection methods of DGE differ from DCE MRI, and it is relevant to compare these techniques in terms of spatiotemporal enhancement patterns. This study aims to develop a DGE analysis method based on tissue response curve shapes, and to investigate whether DGE MRI provides similar or complementary information to DCE MRI. Eleven patients with suspected gliomas were studied. Tissue response curves were measured for DGE and DCE MRI at 7 T and the area under the curve (AUC) was assessed. Seven types of response curve shapes were postulated and subsequently identified by deep learning to create color‐coded “curve maps” showing the spatial distribution of different curve types. DGE AUC values were significantly higher in lesions than in normal tissue (p < 0.007). Furthermore, the distribution of curve types differed between lesions and normal tissue for both DGE and DCE. The DGE and DCE response curves in a 6‐min postinjection time interval were classified as the same curve type in 20% of the lesion voxels, which increased to 29% when a 12‐min DGE time interval was considered. While both DGE and DCE tissue response curve‐shape analysis enabled differentiation of lesions from normal brain tissue in humans, their enhancements were neither temporally identical nor confined entirely to the same regions. Curve maps can provide accessible and intuitive information about the shape of DGE response curves, which is expected to be useful in the continued work towards the interpretation of DGE uptake curves in terms of D‐glucose delivery, transport, and metabolism.
- Open Access
- 10 April 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 770-786
Real‐time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways
Purpose: Respiration‐related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real‐time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions.Methods: A golden‐angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers (n = 10) were scanned at four different respiratory conditions, including repeat scans.Results: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real‐time/reference QR = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio QC = 0.46 ± 0.14). Simulations suggest that QC can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55–0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48–0.90). Net flow was influenced by respiratory condition (p < 0.01).Conclusions: The presented real‐time flow MRI method can quantify respiratory‐related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration.
- 10 April 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (2) , 770-786
Open AccessReal‐time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways
Purpose: Respiration‐related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real‐time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions.Methods: A golden‐angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers (n = 10) were scanned at four different respiratory conditions, including repeat scans.Results: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real‐time/reference QR = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio QC = 0.46 ± 0.14). Simulations suggest that QC can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55–0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48–0.90). Net flow was influenced by respiratory condition (p < 0.01).Conclusions: The presented real‐time flow MRI method can quantify respiratory‐related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration.
- 1 February 2022
- Published by SAGE Publications in Journal of Patient Safety and Risk Management
- Vol. 27 (2) , 76-82
MR- safety: Evaluation of compliance with screening routines using a structured screening interview
Background: Magnetic resonance (MR) safety procedures are designed to allow patients, research subjects and personnel to enter the MR-scanner room under controlled conditions and without the risk to be harmed during the examination. Ferromagnetic objects in the MR-environment or inside the human body represent the main safety risks potentially leading to human injuries. Screening for MR-safety risks with dedicated procedures is therefore mandatory. As human errors during the screening procedure might align and lead to an incident compliance is essential. Purpose: To evaluate compliance with a documented structured MR-safety screening process. Method: Written and signed MR-safety screening documentation collected at a national 7T MR facility during a four-year period was evaluated for compliance of trained personnel with multi-step MR-safety routines. We analysed whether examinations were performed or why they were not performed. Data analysis further included descriptive statistics of the study population (age, gender and patient or healthy volunteer status), identification of missing documents and omitted or incorrect answers, and whether these compliance shortcomings concerned predominantly administrative or MR-safety related issues. Results: Documentation of the screening process in 1819 subjects was incomplete in 19% of subjects. The most common documentation shortcoming was omitted fields. Out of 478 omitted answer-fields in 307 subjects, 36% were of administrative nature and 64% related directly to MR-safety issues. Conclusion: Compliance with MR-safety screening procedures cannot be taken for granted and deficiencies to comply with screening routines were revealed. Documentation shortcomings concerned both administrative and MR-safety related issues.
- 1 February 2022
- Published by SAGE Publications in Journal of Patient Safety and Risk Management
- Vol. 27 (2) , 76-82
MR- safety: Evaluation of compliance with screening routines using a structured screening interview
Background: Magnetic resonance (MR) safety procedures are designed to allow patients, research subjects and personnel to enter the MR-scanner room under controlled conditions and without the risk to be harmed during the examination. Ferromagnetic objects in the MR-environment or inside the human body represent the main safety risks potentially leading to human injuries. Screening for MR-safety risks with dedicated procedures is therefore mandatory. As human errors during the screening procedure might align and lead to an incident compliance is essential. Purpose: To evaluate compliance with a documented structured MR-safety screening process. Method: Written and signed MR-safety screening documentation collected at a national 7T MR facility during a four-year period was evaluated for compliance of trained personnel with multi-step MR-safety routines. We analysed whether examinations were performed or why they were not performed. Data analysis further included descriptive statistics of the study population (age, gender and patient or healthy volunteer status), identification of missing documents and omitted or incorrect answers, and whether these compliance shortcomings concerned predominantly administrative or MR-safety related issues. Results: Documentation of the screening process in 1819 subjects was incomplete in 19% of subjects. The most common documentation shortcoming was omitted fields. Out of 478 omitted answer-fields in 307 subjects, 36% were of administrative nature and 64% related directly to MR-safety issues. Conclusion: Compliance with MR-safety screening procedures cannot be taken for granted and deficiencies to comply with screening routines were revealed. Documentation shortcomings concerned both administrative and MR-safety related issues.
- Open Access
- 11 August 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (2) , 1362-1370
Visualization of wrist anatomy—a comparison between 7T and 3T MRI
Objective: Injuries to the wrist are, due to its small size and complex anatomical structures, difficult to assess by MR, and surgical interventions such as diagnostic arthroscopy are often necessary. Therefore, improved visualization using non-invasive methods could be of clinical value. As a first step of improvement, the purpose of this study was to evaluate visualization of anatomical structures at 7T compared with 3T MR. Methods: Eighteen healthy volunteers (three males and three females from each age decade between 20 and 49 years) were examined with 7T and 3T MR. Four musculoskeletal radiologists graded 2D and 3D images on a five-level grading scale for visibility of ligaments, cartilage, nerves, trabecular bone, and tendons, as well as overall image quality (i.e., edge sharpness, perceived tissue contrast, and presence of artefacts). Statistical analysis was done using a visual grading characteristics (VGC) analysis. Results: Visibility of cartilage, trabecular bone, tendons, nerves, and ligaments was graded significantly higher at 7T with an area under the curve (AUCVGC) of 0.62–0.88 (95% confidence interval [CI] 0.50–0.97, p = < 0.0001–0.03) using either 2D or 3D imaging. Imaging with 3T was not graded as superior to 7T for any structure. Image quality was also significantly superior at 7T, except for artefacts, where no significant differences were found. Conclusions: Tendons, trabecular bone, nerves, and ligaments were all significantly better visualized at 7T compared to 3T. Key Points: • MRI of the wrist at 7T with a commercially available wrist coil is feasible at similar acquisition times as for 3T MRI. • The current study showed 7T to be superior to 3T in the visualization of anatomical structures of the wrist, including ligaments, tendons, nerves, and trabecular bone. • Image quality was significantly superior at 7T, except for artefacts, where no significant differences were found.
- 11 August 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (2) , 1362-1370
Open AccessVisualization of wrist anatomy—a comparison between 7T and 3T MRI
Objective: Injuries to the wrist are, due to its small size and complex anatomical structures, difficult to assess by MR, and surgical interventions such as diagnostic arthroscopy are often necessary. Therefore, improved visualization using non-invasive methods could be of clinical value. As a first step of improvement, the purpose of this study was to evaluate visualization of anatomical structures at 7T compared with 3T MR. Methods: Eighteen healthy volunteers (three males and three females from each age decade between 20 and 49 years) were examined with 7T and 3T MR. Four musculoskeletal radiologists graded 2D and 3D images on a five-level grading scale for visibility of ligaments, cartilage, nerves, trabecular bone, and tendons, as well as overall image quality (i.e., edge sharpness, perceived tissue contrast, and presence of artefacts). Statistical analysis was done using a visual grading characteristics (VGC) analysis. Results: Visibility of cartilage, trabecular bone, tendons, nerves, and ligaments was graded significantly higher at 7T with an area under the curve (AUCVGC) of 0.62–0.88 (95% confidence interval [CI] 0.50–0.97, p = < 0.0001–0.03) using either 2D or 3D imaging. Imaging with 3T was not graded as superior to 7T for any structure. Image quality was also significantly superior at 7T, except for artefacts, where no significant differences were found. Conclusions: Tendons, trabecular bone, nerves, and ligaments were all significantly better visualized at 7T compared to 3T. Key Points: • MRI of the wrist at 7T with a commercially available wrist coil is feasible at similar acquisition times as for 3T MRI. • The current study showed 7T to be superior to 3T in the visualization of anatomical structures of the wrist, including ligaments, tendons, nerves, and trabecular bone. • Image quality was significantly superior at 7T, except for artefacts, where no significant differences were found.
- Open Access
- 11 August 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-7
The potential role of T2*-weighted multi-echo data image combination as an imaging marker for intraplaque hemorrhage in carotid plaque imaging
Background: Carotid atherosclerotic plaques with intraplaque hemorrhage (IPH) are associated with elevated stroke risk. IPH is predominantly imaged based on paramagnetic properties of the upstream hemoglobin degradation product methemoglobin. This is an explorative observational study to test the feasibility of a spoiled gradient echo based T2* weighted MRI sequence (3D MEDIC) for carotid plaque imaging, and to compare signs suggestive of the downstream degradation product hemosiderin on 3D MEDIC with signs of methemoglobin on a T1wBB sequence. Methods: Patients with recent TIA or stroke were selected based on the presence on non-calcified plaque components on CTA to promote an enriched prevalence of IPH in the material. Patients (n = 42) underwent 3T MRI with 3D MEDIC and 2D turbo spin echo T1w black blood (T1wBB). Images were independently evaluated by two neuroradiologists and Cohens Kappa was used for inter-reader agreement for each sequence. Results: The technical feasibility for 3D MEDIC, was 34/42 patients (81%). Non-calcified plaque components with susceptibility effect without simultaneous T1-shortening—a combination suggestive of hemosiderin, was seen in 13/34 of the plaques. An equally large group display elevated T1w signal in combination with signal loss on 3D MEDIC, a combination suggestive of both hemosiderin and methemoglobin. Cohen’s kappa for inter-reader agreement was 0.64 (CI 0.345–0.925) for 3D MEDIC and 0.94 (CI 0.81–1.00) for T1wBB. Conclusions: 3D MEDIC shows signal loss, without elevated T1w signal on T1wBB, in non-calcified tissue in many plaques in this group of patients. If further studies, including histological verification, confirm that the 3D MEDIC susceptibility effect is indeed caused by hemosiderin, 3D MEDIC could aid in the detection of IPH, beyond elevation of T1w signal.
- 11 August 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-7
Open AccessThe potential role of T2*-weighted multi-echo data image combination as an imaging marker for intraplaque hemorrhage in carotid plaque imaging
Background: Carotid atherosclerotic plaques with intraplaque hemorrhage (IPH) are associated with elevated stroke risk. IPH is predominantly imaged based on paramagnetic properties of the upstream hemoglobin degradation product methemoglobin. This is an explorative observational study to test the feasibility of a spoiled gradient echo based T2* weighted MRI sequence (3D MEDIC) for carotid plaque imaging, and to compare signs suggestive of the downstream degradation product hemosiderin on 3D MEDIC with signs of methemoglobin on a T1wBB sequence. Methods: Patients with recent TIA or stroke were selected based on the presence on non-calcified plaque components on CTA to promote an enriched prevalence of IPH in the material. Patients (n = 42) underwent 3T MRI with 3D MEDIC and 2D turbo spin echo T1w black blood (T1wBB). Images were independently evaluated by two neuroradiologists and Cohens Kappa was used for inter-reader agreement for each sequence. Results: The technical feasibility for 3D MEDIC, was 34/42 patients (81%). Non-calcified plaque components with susceptibility effect without simultaneous T1-shortening—a combination suggestive of hemosiderin, was seen in 13/34 of the plaques. An equally large group display elevated T1w signal in combination with signal loss on 3D MEDIC, a combination suggestive of both hemosiderin and methemoglobin. Cohen’s kappa for inter-reader agreement was 0.64 (CI 0.345–0.925) for 3D MEDIC and 0.94 (CI 0.81–1.00) for T1wBB. Conclusions: 3D MEDIC shows signal loss, without elevated T1w signal on T1wBB, in non-calcified tissue in many plaques in this group of patients. If further studies, including histological verification, confirm that the 3D MEDIC susceptibility effect is indeed caused by hemosiderin, 3D MEDIC could aid in the detection of IPH, beyond elevation of T1w signal.
- Open Access
- 18 January 2021
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 41 (9) , 2137-2149
Achieving brain clearance and preventing neurodegenerative diseases—A glymphatic perspective
Age-related neurodegenerative diseases are a growing burden to society, and many are sporadic, meaning that the environment, diet and lifestyle play significant roles. Cerebrospinal fluid (CSF)-mediated clearing of brain waste products via perivascular pathways, named the glymphatic system, is receiving increasing interest, as it offers unexplored perspectives on understanding neurodegenerative diseases. The glymphatic system is involved in clearance of metabolic by-products such as amyloid-β from the brain, and its function is believed to lower the risk of developing some of the most common neurodegenerative diseases. Here, we present magnetic resonance imaging (MRI) data on the heart cycle’s control of CSF flow in humans which corroborates findings from animal studies. We also review the importance of sleep, diet, vascular health for glymphatic clearance and find that these factors are also known players in brain longevity.
- 18 January 2021
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 41 (9) , 2137-2149
Open AccessAchieving brain clearance and preventing neurodegenerative diseases—A glymphatic perspective
Age-related neurodegenerative diseases are a growing burden to society, and many are sporadic, meaning that the environment, diet and lifestyle play significant roles. Cerebrospinal fluid (CSF)-mediated clearing of brain waste products via perivascular pathways, named the glymphatic system, is receiving increasing interest, as it offers unexplored perspectives on understanding neurodegenerative diseases. The glymphatic system is involved in clearance of metabolic by-products such as amyloid-β from the brain, and its function is believed to lower the risk of developing some of the most common neurodegenerative diseases. Here, we present magnetic resonance imaging (MRI) data on the heart cycle’s control of CSF flow in humans which corroborates findings from animal studies. We also review the importance of sleep, diet, vascular health for glymphatic clearance and find that these factors are also known players in brain longevity.