Glauco Brandolino
Glauco Brandolino has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Emanuele Bertaglia
Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padua, 35128 Padua, Italy
7 shared publications - Franco Zoppo
U.O.C. Cardiologia, Ospedale Civile Gorizia, Gorizia, Italy
7 shared publications Francesca Zerbo
4 shared publicationsPietro Pascotto
Dipartimento di Cardiologia, Ospedale Civile di Mirano, Venice, Italy
2 shared publicationsA. Berton
Ospedale Civile Mirano (Venezia)
1 shared publicationA. Lupo
Ospedale Civile Mirano (Venezia)
1 shared publication
Latest Publications
- Open Access
- 13 January 2016
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 5 (1) , e4
Large Controlled Observational Study on Remote Monitoring of Pacemakers and Implantable Cardiac Defibrillators: A Clinical, Economic, and Organizational Evaluation
Interactive Journal of Medical Research
- 13 January 2016
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 5 (1) , e4
Open AccessLarge Controlled Observational Study on Remote Monitoring of Pacemakers and Implantable Cardiac Defibrillators: A Clinical, Economic, and Organizational Evaluation
Interactive Journal of Medical Research
- 21 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (3) , 403-408
Long-term clinical outcome of patients who failed catheter ablation of atrial fibrillation
Aims Left atrial ablation fails to prevent symptomatic recurrences of atrial fibrillation (AF) in 20–30% of patients up to 3 years of follow-up despite multiple procedures. Data are lacking on the long-term clinical outcome of those patients for whom the decision was taken to renounce performing further ablation procedures. Methods and results In this multicentre study, 218 (34%) of 631 consecutive patients, who had undergone AF catheter ablation in the years 2001–11 for drug-refractory symptomatic AF, had symptomatic AF recurrences after 1.5 ± 0.6 procedures. Their long-term clinical outcome was assessed in March 2012 (minimum follow-up 1 year). At a mean of 5.1 ± 2.6 years since their last ablation, 82 (38%) patients improved, 103 (47%) remained unchanged and 33 (15%) worsened, but only 17 (8%) had such a severe impairment of their quality of life as to require atrioventricular junction ablation and pacing (#13) or cardiac surgery (#4); 22 (10%) patients had had adverse clinical events (death in five, heart failure in five, stroke and transient ischaemic cerebral attack in four, severe haemorrhage in four, pacemaker or implantable cardioverter-defibrillator implantation in seven) and 98 (45%) patients had developed permanent AF. Compared with patients without permanent AF, fewer patients with permanent AF improved (3% vs. 66%, P = 0.001) and more got worse (28% vs. 5%, P = 0.001). At multivariable logistic regression, single ablation procedure, left atrial diameter, persistent AF and time from the last ablation were independent predictors of permanent AF. Conclusion More than 5 years after a failed AF ablation, a small minority of patients had such an impaired quality of life as to require non-pharmacological interventions. Almost half developed permanent AF, which significantly impaired quality of life. Permanent AF was more common in patients who had left atrial enlargement, history of persistent AF, longer follow-up, and had performed a single ablation procedure, thus hypothesizing that reablation could reduce the chronicization of arrhythmia. A low risk of stroke was observed in the long-term follow-up.
- 21 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (3) , 403-408
Long-term clinical outcome of patients who failed catheter ablation of atrial fibrillation
Aims Left atrial ablation fails to prevent symptomatic recurrences of atrial fibrillation (AF) in 20–30% of patients up to 3 years of follow-up despite multiple procedures. Data are lacking on the long-term clinical outcome of those patients for whom the decision was taken to renounce performing further ablation procedures. Methods and results In this multicentre study, 218 (34%) of 631 consecutive patients, who had undergone AF catheter ablation in the years 2001–11 for drug-refractory symptomatic AF, had symptomatic AF recurrences after 1.5 ± 0.6 procedures. Their long-term clinical outcome was assessed in March 2012 (minimum follow-up 1 year). At a mean of 5.1 ± 2.6 years since their last ablation, 82 (38%) patients improved, 103 (47%) remained unchanged and 33 (15%) worsened, but only 17 (8%) had such a severe impairment of their quality of life as to require atrioventricular junction ablation and pacing (#13) or cardiac surgery (#4); 22 (10%) patients had had adverse clinical events (death in five, heart failure in five, stroke and transient ischaemic cerebral attack in four, severe haemorrhage in four, pacemaker or implantable cardioverter-defibrillator implantation in seven) and 98 (45%) patients had developed permanent AF. Compared with patients without permanent AF, fewer patients with permanent AF improved (3% vs. 66%, P = 0.001) and more got worse (28% vs. 5%, P = 0.001). At multivariable logistic regression, single ablation procedure, left atrial diameter, persistent AF and time from the last ablation were independent predictors of permanent AF. Conclusion More than 5 years after a failed AF ablation, a small minority of patients had such an impaired quality of life as to require non-pharmacological interventions. Almost half developed permanent AF, which significantly impaired quality of life. Permanent AF was more common in patients who had left atrial enlargement, history of persistent AF, longer follow-up, and had performed a single ablation procedure, thus hypothesizing that reablation could reduce the chronicization of arrhythmia. A low risk of stroke was observed in the long-term follow-up.
- 7 August 2012
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 35 (2) , 151-158
Predictors of left atrium appendage clot detection despite on-target warfarin prevention for atrial fibrillation
The antithrombotic management of atrial fibrillation (AF) is currently based on clinical scores (CHADS2 or CHA2DS2VASc). The prevalence of left atrium (LA) thrombi in effectively anticoagulated AF patients has been reported as being up to 7.7 %. We tried to correlate LA/LA appendage (LAA) thrombus detection with possible clinical predictors in warfarin-treated patients. We performed trans-esophageal echocardiography on 430 patients (mean age, 60.3 ± 9.8 years) receiving oral anticoagulant (OAC) therapy and undergoing pulmonary vein isolation. In 10/430 (2.3 %), an LA thrombus was found despite therapeutic OAC (mean INR 2.6 ± 0.6; range, 2.0–3.8) over the previous 4 weeks. Two study groups were identified: T-positive group = with LAA thrombus (10 patients) T-negative group = without LAA thrombus (420 patients) The T-positive patients had a higher CHADS2 score (1.5 ± 0.7 versus 0.7 ± 0.8; p = 0.004), a lower LVEF (54.7 ± 9.5 % versus 60.2 ± 7.4; p = 0.02), and a larger LA size (LA diameter, 56 ± 12.2 mm versus 46 ± 6.5 mm; p < 0.001and normalized LA volume: 140.2 ± 66 ml/m² vs. 67 ± 39 ml/m²; p < 0.05). On multivariate analysis, a larger LA diameter and normalized LA volume (OR, 1.14; 95 % C.I., 1.04–1.26; p = 0.006 and OR, 1.02; 95 % C.I., 1.01–1.03; p = 0.001, respectively) and a higher CHA2DS2VASc score (OR, 2.4; 95 % C.I., 1.4–4.2; p = 0.001) predicted left atrium appendage (LAA) thrombus. In another 42/430 (9.8 %) patients, an LA spontaneous echo-contrast (SEC) was detected. Thus, cumulatively, 52/430 (12.1 %) patients had either LAA thrombi (10 patients) or SEC (42 patients). LA diameter continued to predict the presence of either thrombi or SEC (OR, 1.14; 95 % C.I., 1.07–1.2; p < 0.05). We found a 2.3 % prevalence of LA thrombus (12.1 % when SEC was also considered). The thrombus was present despite on-target warfarin prevention. In addition to a higher CHA2DS2VASc score, a larger LA size was a strong predictor of clot detection.
- 7 August 2012
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 35 (2) , 151-158
Predictors of left atrium appendage clot detection despite on-target warfarin prevention for atrial fibrillation
The antithrombotic management of atrial fibrillation (AF) is currently based on clinical scores (CHADS2 or CHA2DS2VASc). The prevalence of left atrium (LA) thrombi in effectively anticoagulated AF patients has been reported as being up to 7.7 %. We tried to correlate LA/LA appendage (LAA) thrombus detection with possible clinical predictors in warfarin-treated patients. We performed trans-esophageal echocardiography on 430 patients (mean age, 60.3 ± 9.8 years) receiving oral anticoagulant (OAC) therapy and undergoing pulmonary vein isolation. In 10/430 (2.3 %), an LA thrombus was found despite therapeutic OAC (mean INR 2.6 ± 0.6; range, 2.0–3.8) over the previous 4 weeks. Two study groups were identified: T-positive group = with LAA thrombus (10 patients) T-negative group = without LAA thrombus (420 patients) The T-positive patients had a higher CHADS2 score (1.5 ± 0.7 versus 0.7 ± 0.8; p = 0.004), a lower LVEF (54.7 ± 9.5 % versus 60.2 ± 7.4; p = 0.02), and a larger LA size (LA diameter, 56 ± 12.2 mm versus 46 ± 6.5 mm; p < 0.001and normalized LA volume: 140.2 ± 66 ml/m² vs. 67 ± 39 ml/m²; p < 0.05). On multivariate analysis, a larger LA diameter and normalized LA volume (OR, 1.14; 95 % C.I., 1.04–1.26; p = 0.006 and OR, 1.02; 95 % C.I., 1.01–1.03; p = 0.001, respectively) and a higher CHA2DS2VASc score (OR, 2.4; 95 % C.I., 1.4–4.2; p = 0.001) predicted left atrium appendage (LAA) thrombus. In another 42/430 (9.8 %) patients, an LA spontaneous echo-contrast (SEC) was detected. Thus, cumulatively, 52/430 (12.1 %) patients had either LAA thrombi (10 patients) or SEC (42 patients). LA diameter continued to predict the presence of either thrombi or SEC (OR, 1.14; 95 % C.I., 1.07–1.2; p < 0.05). We found a 2.3 % prevalence of LA thrombus (12.1 % when SEC was also considered). The thrombus was present despite on-target warfarin prevention. In addition to a higher CHA2DS2VASc score, a larger LA size was a strong predictor of clot detection.
- 1 May 2012
- Published by Elsevier in International Journal of Cardiology
- Vol. 156 (3) , 270-276
Late atrial tachycardia following pulmonary vein isolation: Analysis of successful discrete ablation sites
- 1 May 2012
- Published by Elsevier in International Journal of Cardiology
- Vol. 156 (3) , 270-276
Late atrial tachycardia following pulmonary vein isolation: Analysis of successful discrete ablation sites
- 31 January 2012
- Vol. 60 (3) , 275-90
Activation mapping to determine the mechanism of atrial tachycardia when pacing techniques are not feasible.
Atrial tachycardia/flutter (ATAF) could be sustained by a focus or a reentry circuit, which mapping differs significantly. Entrainment mapping is widely used to detect reentry, but it is not always feasible. We evaluated an activation mapping protocol to differentiate macro, micro-reentrant and focal ATAFs. Among 454 patients who underwent ablation for supraventricular tachycardia (SVT) between December, 2004 and August, 2008, 52 ATAF patients were selected and assessed by means of activation mapping (study mapping protocol). The remaining 402 cases (AVNRT, AVRT, and common atrial flutter) were excluded. Fifty-eight ATAF morphologies were mapped (mean CL 297.2±98 ms). The protocol identified the ATAF mechanism in 53/58 (91%, 52 successfully ablated) morphologies, while the mapping technique failed in 5/58 (9%) cases/patients. Among the 53 ATAF diagnoses, 25/53 (47%) were macroreentrant ATAFs (MATs), whereas 12/53 (23%) were focal ATAFs (FATs) or microreentrant ATAFs (MIATs) (16/53, 30%). Ablation was successful in 25/25 cases of the MAT group, in 11/12 (91.7%) cases of the FAT group, and in 16/16 cases of the MIAT group. At the end of the procedure, no ATAF was inducible in 44/52 (85%) patients. The study protocol was successfully validated in 20 patients (10 with AVNRT, and 10 with common atrial flutter) of the control group. After a mean follow-up of 21.5±12.5 months, 36/52 (70%) pts resulted free from ATAF. Non-inducibility predicted long-term freedom from ATAF (92.1 % vs. 60 %, P=0.005, OR 0.09; 95% CI 0.18-0.51, P=0.006). Activation mapping alone may be reliable to determine the ATAF mechanism, especially when pacing techniques are not feasible.
- 31 January 2012
- Vol. 60 (3) , 275-90
Activation mapping to determine the mechanism of atrial tachycardia when pacing techniques are not feasible.
Atrial tachycardia/flutter (ATAF) could be sustained by a focus or a reentry circuit, which mapping differs significantly. Entrainment mapping is widely used to detect reentry, but it is not always feasible. We evaluated an activation mapping protocol to differentiate macro, micro-reentrant and focal ATAFs. Among 454 patients who underwent ablation for supraventricular tachycardia (SVT) between December, 2004 and August, 2008, 52 ATAF patients were selected and assessed by means of activation mapping (study mapping protocol). The remaining 402 cases (AVNRT, AVRT, and common atrial flutter) were excluded. Fifty-eight ATAF morphologies were mapped (mean CL 297.2±98 ms). The protocol identified the ATAF mechanism in 53/58 (91%, 52 successfully ablated) morphologies, while the mapping technique failed in 5/58 (9%) cases/patients. Among the 53 ATAF diagnoses, 25/53 (47%) were macroreentrant ATAFs (MATs), whereas 12/53 (23%) were focal ATAFs (FATs) or microreentrant ATAFs (MIATs) (16/53, 30%). Ablation was successful in 25/25 cases of the MAT group, in 11/12 (91.7%) cases of the FAT group, and in 16/16 cases of the MIAT group. At the end of the procedure, no ATAF was inducible in 44/52 (85%) patients. The study protocol was successfully validated in 20 patients (10 with AVNRT, and 10 with common atrial flutter) of the control group. After a mean follow-up of 21.5±12.5 months, 36/52 (70%) pts resulted free from ATAF. Non-inducibility predicted long-term freedom from ATAF (92.1 % vs. 60 %, P=0.005, OR 0.09; 95% CI 0.18-0.51, P=0.006). Activation mapping alone may be reliable to determine the ATAF mechanism, especially when pacing techniques are not feasible.
- 5 January 2011
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 325-330
Straight Screw‐In Atrial Leads “J‐Post Shaped” in Right Appendage Versus J‐Shaped Systems for Permanent Atrial Pacing: A Safety Comparison
Background and Objectives: The reliability of active‐fixation atrial leads has been compared with that of passive‐fixation leads; comparisons have also been made between straight and J‐shaped screw‐in lead systems. However, few data are available on procedural and short‐term safety. This retrospective study compared the procedural safety of non‐pre‐shaped screw‐in leads with that of passive‐ and active‐fixation J‐shaped leads. Patients and Methods: From January 2004 to January 2010, 1,464 patients underwent new pacemaker/implantable cardioverter‐defibrillator implantation. Of these, 915 (study population) received a passive‐ or active‐fixation pre‐J‐shaped lead, or a straight screw‐in atrial lead; the remaining 549 patients, who received only a ventricular lead, were excluded. The three study groups were: Group S‐FIX (165 patients, 18%), receiving a straight screw‐in atrial lead (postshaped in the right appendage); Group J‐PASS (690 patients, 75.4%), receiving a passive‐fixation J‐shaped atrial lead; and Group J‐FIX (60 patients, 6.6%), receiving an active‐fixation screw‐in J‐shaped atrial lead. Procedural and short‐term complication rates were analyzed up to 3 months postimplantation. Results: One complication occurred in each group (S‐FIX 0.6% vs J‐PASS 0.1% vs J‐FIX 1.6%, P = 0.3, 0.1, and 0.4, respectively, for each comparison). The rate of atrial lead dislodgement was higher in Group J‐PASS than in S‐FIX but not J‐FIX (Group S‐FIX 0 vs Group J‐PASS 16 vs Group J‐FIX 1 dislodgements; P = 0.04 and 0.7, respectively). Conclusion: Straight screw‐in atrial leads, “J‐post shaped” in the right appendage, offer better stability than passive‐fixation J‐shaped leads and display a similarly acceptable safety profile compared with both the J‐shaped systems. (PACE 2011; 34:325–330)
- 5 January 2011
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (3) , 325-330
Straight Screw‐In Atrial Leads “J‐Post Shaped” in Right Appendage Versus J‐Shaped Systems for Permanent Atrial Pacing: A Safety Comparison
Background and Objectives: The reliability of active‐fixation atrial leads has been compared with that of passive‐fixation leads; comparisons have also been made between straight and J‐shaped screw‐in lead systems. However, few data are available on procedural and short‐term safety. This retrospective study compared the procedural safety of non‐pre‐shaped screw‐in leads with that of passive‐ and active‐fixation J‐shaped leads. Patients and Methods: From January 2004 to January 2010, 1,464 patients underwent new pacemaker/implantable cardioverter‐defibrillator implantation. Of these, 915 (study population) received a passive‐ or active‐fixation pre‐J‐shaped lead, or a straight screw‐in atrial lead; the remaining 549 patients, who received only a ventricular lead, were excluded. The three study groups were: Group S‐FIX (165 patients, 18%), receiving a straight screw‐in atrial lead (postshaped in the right appendage); Group J‐PASS (690 patients, 75.4%), receiving a passive‐fixation J‐shaped atrial lead; and Group J‐FIX (60 patients, 6.6%), receiving an active‐fixation screw‐in J‐shaped atrial lead. Procedural and short‐term complication rates were analyzed up to 3 months postimplantation. Results: One complication occurred in each group (S‐FIX 0.6% vs J‐PASS 0.1% vs J‐FIX 1.6%, P = 0.3, 0.1, and 0.4, respectively, for each comparison). The rate of atrial lead dislodgement was higher in Group J‐PASS than in S‐FIX but not J‐FIX (Group S‐FIX 0 vs Group J‐PASS 16 vs Group J‐FIX 1 dislodgements; P = 0.04 and 0.7, respectively). Conclusion: Straight screw‐in atrial leads, “J‐post shaped” in the right appendage, offer better stability than passive‐fixation J‐shaped leads and display a similarly acceptable safety profile compared with both the J‐shaped systems. (PACE 2011; 34:325–330)
- 28 February 2008
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (3) , 273-282
Integration of Three‐Dimensional Left Atrial Magnetic Resonance Images into a Real‐Time Electroanatomic Mapping System: Validation of a Registration Method
The alignment of three-dimensional (3D) left atrial images acquired by magnetic resonance (MR) with the anatomical information yielded by 3D mapping systems is one of the most critical issues in image integration techniques for catheter ablation of atrial fibrillation (AF). We assessed the accuracy of a simplified method of superimposing 3D MR left atrial images on real-time left atrial electroanatomic maps (registration). MR data on the left atrium in 40 patients with drug-refractory AF were imported into the CartoMerge (Biosense Webster, Inc., Diamond Bar, CA, USA) electroanatomic mapping system. Registration was obtained by combining "visual alignment" of one endocardial point and "surface registration" of a limited number of points sampled on the posterior wall of the left atrium. The accuracy of the registration process was assessed through a statistical algorithm incorporated into the CartoMerge system, and through the percentage of pulmonary veins (PVs) in which electrical isolation was achieved after anatomical ablation. The mean registration surface-to-point distance and ablation surface-to-point distance were 1.33 +/- 0.96 mm and 1.47 +/- 1.15 mm, respectively. Upon completion of the circumferential anatomical ablation around the PVs, electrical PV isolation was confirmed by a multipolar circular mapping catheter in 129 of 146 PVs (89%). Our registration method, which is mainly based on the surface registration of the posterior wall of the left atrium, enables almost 90% of PVs to be isolated by means of an anatomically based catheter ablation approach.
- 28 February 2008
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 31 (3) , 273-282
Integration of Three‐Dimensional Left Atrial Magnetic Resonance Images into a Real‐Time Electroanatomic Mapping System: Validation of a Registration Method
The alignment of three-dimensional (3D) left atrial images acquired by magnetic resonance (MR) with the anatomical information yielded by 3D mapping systems is one of the most critical issues in image integration techniques for catheter ablation of atrial fibrillation (AF). We assessed the accuracy of a simplified method of superimposing 3D MR left atrial images on real-time left atrial electroanatomic maps (registration). MR data on the left atrium in 40 patients with drug-refractory AF were imported into the CartoMerge (Biosense Webster, Inc., Diamond Bar, CA, USA) electroanatomic mapping system. Registration was obtained by combining "visual alignment" of one endocardial point and "surface registration" of a limited number of points sampled on the posterior wall of the left atrium. The accuracy of the registration process was assessed through a statistical algorithm incorporated into the CartoMerge system, and through the percentage of pulmonary veins (PVs) in which electrical isolation was achieved after anatomical ablation. The mean registration surface-to-point distance and ablation surface-to-point distance were 1.33 +/- 0.96 mm and 1.47 +/- 1.15 mm, respectively. Upon completion of the circumferential anatomical ablation around the PVs, electrical PV isolation was confirmed by a multipolar circular mapping catheter in 129 of 146 PVs (89%). Our registration method, which is mainly based on the surface registration of the posterior wall of the left atrium, enables almost 90% of PVs to be isolated by means of an anatomically based catheter ablation approach.
- 1 July 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (7) , 921-924
Atrio-Ventricular Block During Left Atrial Flutter Ablation
We present a case of a patient treated with catheter ablation for atrial fibrillation aiming to pulmonary veins isolation. During ablation, atrial fibrillation organized into a left atrial flutter. Electroanatomic and electrophysiologic mapping revealed the anterior left atrium area between the mitral annulus and left atrium septum as a critical region for flutter ablation. After a few pulses of radiofrequency, complete atrio-ventricular block appeared. Finally, we propose pace mapping of the mitral annulus to detect left dislodgment of the compact atrio-ventricular node.
- 1 July 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (7) , 921-924
Atrio-Ventricular Block During Left Atrial Flutter Ablation
We present a case of a patient treated with catheter ablation for atrial fibrillation aiming to pulmonary veins isolation. During ablation, atrial fibrillation organized into a left atrial flutter. Electroanatomic and electrophysiologic mapping revealed the anterior left atrium area between the mitral annulus and left atrium septum as a critical region for flutter ablation. After a few pulses of radiofrequency, complete atrio-ventricular block appeared. Finally, we propose pace mapping of the mitral annulus to detect left dislodgment of the compact atrio-ventricular node.