Rita Paniccia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rita Paniccia has a total of 226 co-authors. Here are the top co-authors by number of shared publications:
Rosanna Abbate
Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
48 shared publications- Domenico Prisco
Department of Experimental and Clinical Medicine, University of Florence, 50121 Florence, Italy
43 shared publications Gian Franco Gensini
Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Don Carlo Gnocchi Foundation, IRCCS, Florence, Italy
40 shared publications- Rossella Marcucci
University of Florence
34 shared publications Anna Maria Gori
Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; Don Carlo Gnocchi Foundation, Florence, Italy
27 shared publications- Betti Giusti
Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy
27 shared publications
Latest Publications
- 1 May 2016
- Published by Elsevier in European Journal of Internal Medicine
- Vol. 30, 49-54
High on-aspirin platelet reactivity predicts cardiac death in acute coronary syndrome patients undergoing PCI
- 1 May 2016
- Published by Elsevier in European Journal of Internal Medicine
- Vol. 30, 49-54
High on-aspirin platelet reactivity predicts cardiac death in acute coronary syndrome patients undergoing PCI
- 20 December 2015
- Published by Springer Nature
- p. 35-58
General Aspects of Platelet Function Tests
- 1 September 2015
- Published by Elsevier in Thrombosis Research
- Vol. 136 (3) , 613-619
A time course study of high on treatment platelet reactivity in acute coronary syndrome male patients on dual antiplatelet therapy
- 1 September 2015
- Published by Elsevier in Thrombosis Research
- Vol. 136 (3) , 613-619
A time course study of high on treatment platelet reactivity in acute coronary syndrome male patients on dual antiplatelet therapy
- 1 September 2015
- Published by Elsevier in Journal of Cardiology Cases
- Vol. 12 (3) , 65-67
Non-traumatic splenic rupture on dual antiplatelet therapy with aspirin and ticagrelor after stenting for acute coronary syndrome
- 1 September 2015
- Published by Elsevier in Journal of Cardiology Cases
- Vol. 12 (3) , 65-67
Non-traumatic splenic rupture on dual antiplatelet therapy with aspirin and ticagrelor after stenting for acute coronary syndrome
- Top Cited PapersOpen Access
- 1 February 2015
- Published by Taylor & Francis in Vascular Health and Risk Management
- Vol. 11, 133-148
Platelet function tests: a comparative review
In physiological hemostasis a prompt recruitment of platelets on the vessel damage prevents the bleeding by the rapid formation of a platelet plug. Qualitative and/or quantitative platelet defects promote bleeding, whereas the high residual reactivity of platelets in patients on antiplatelet therapies moves forward thromboembolic complications. The biochemical mechanisms of the different phases of platelet activation – adhesion, shape change, release reaction, and aggregation – have been well delineated, whereas their complete translation into laboratory assays has not been so fulfilled. Laboratory tests of platelet function, such as bleeding time, light transmission platelet aggregation, lumiaggregometry, impedance aggregometry on whole blood, and platelet activation investigated by flow cytometry, are traditionally utilized for diagnosing hemostatic disorders and managing patients with platelet and hemostatic defects, but their use is still limited to specialized laboratories. To date, a point-of-care testing (POCT) dedicated to platelet function, using pertinent devices much simpler to use, has now become available (ie, PFA-100, VerifyNow System, Multiplate Electrode Aggregometry [MEA]). POCT includes new methodologies which may be used in critical clinical settings and also in general laboratories because they are rapid and easy to use, employing whole blood without the necessity of sample processing. Actually, these different platelet methodologies for the evaluation of inherited and acquired bleeding disorders and/or for monitoring antiplatelet therapies are spreading and the study of platelet function is strengthening. In this review, well-tried and innovative platelet function tests and their methodological features and clinical applications are considered.
- 1 February 2015
- Published by Taylor & Francis in Vascular Health and Risk Management
- Vol. 11, 133-148
Top Cited PapersOpen AccessPlatelet function tests: a comparative review
In physiological hemostasis a prompt recruitment of platelets on the vessel damage prevents the bleeding by the rapid formation of a platelet plug. Qualitative and/or quantitative platelet defects promote bleeding, whereas the high residual reactivity of platelets in patients on antiplatelet therapies moves forward thromboembolic complications. The biochemical mechanisms of the different phases of platelet activation – adhesion, shape change, release reaction, and aggregation – have been well delineated, whereas their complete translation into laboratory assays has not been so fulfilled. Laboratory tests of platelet function, such as bleeding time, light transmission platelet aggregation, lumiaggregometry, impedance aggregometry on whole blood, and platelet activation investigated by flow cytometry, are traditionally utilized for diagnosing hemostatic disorders and managing patients with platelet and hemostatic defects, but their use is still limited to specialized laboratories. To date, a point-of-care testing (POCT) dedicated to platelet function, using pertinent devices much simpler to use, has now become available (ie, PFA-100, VerifyNow System, Multiplate Electrode Aggregometry [MEA]). POCT includes new methodologies which may be used in critical clinical settings and also in general laboratories because they are rapid and easy to use, employing whole blood without the necessity of sample processing. Actually, these different platelet methodologies for the evaluation of inherited and acquired bleeding disorders and/or for monitoring antiplatelet therapies are spreading and the study of platelet function is strengthening. In this review, well-tried and innovative platelet function tests and their methodological features and clinical applications are considered.
- 14 December 2014
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 40 (1) , 76-82
Residual platelet reactivity to predict long-term clinical outcomes after clopidogrel loading in patients with acute coronary syndromes: comparison of different cutoff values by light transmission aggregometry from the responsiveness to clopidogrel and stent thrombosis 2-acute coronary syndrome (RECLOSE 2-ACS) study
The aim of this study was the identification of the optimal cutoff value of high residual platelet reactivity (HRPR) assessed by light transmission aggregometry (LTA) in the responsiveness to clopidogrel and stent thrombosis 2-acute coronary syndrome (RECLOSE 2-ACS) patient cohort to discriminate patients with and without major adverse cardiac events (MACE) and cardiac death at 2 years. The RECLOSE 2-ACS study included 1,789 patients with ACS who underwent LTA after clopidogrel loading. A post hoc cutoff value for HRPR was defined with the ROC curve and the Youden index and compared with the protocol-defined cutoff of 70 %. By ROC analysis, 63 % resulted the optimal cutoff value to predict both MACE and cardiac death at 2 years follow-up. A significant sensitivity improvement for the ROC-based cutoff value was noted (p < 0.001), at the price of lower specificity and predictive accuracy. The latter were 81 % for MACE and 85 % for cardiac death with the 70 % cutoff, while the respective figures were 73 and 75 % with the 63 % cutoff. The areas under the curve were virtually identical with the 70 and 63 % cutoffs both for MACE (0.71) and cardiac death (0.79). A residual platelet reactivity cutoff of 70 % by LTA, compared to the ROC-based cutoff of 63 %, allows for the identification of a subset of patients at very high risk of adverse ischemic events, making LTA-ADP test more acceptable in clinical practice for the identification of subjects at risk than other platelet function assays with broader definitions of HRPR.
- 14 December 2014
- Published by Springer Nature in Journal of Thrombosis and Thrombolysis
- Vol. 40 (1) , 76-82
Residual platelet reactivity to predict long-term clinical outcomes after clopidogrel loading in patients with acute coronary syndromes: comparison of different cutoff values by light transmission aggregometry from the responsiveness to clopidogrel and stent thrombosis 2-acute coronary syndrome (RECLOSE 2-ACS) study
The aim of this study was the identification of the optimal cutoff value of high residual platelet reactivity (HRPR) assessed by light transmission aggregometry (LTA) in the responsiveness to clopidogrel and stent thrombosis 2-acute coronary syndrome (RECLOSE 2-ACS) patient cohort to discriminate patients with and without major adverse cardiac events (MACE) and cardiac death at 2 years. The RECLOSE 2-ACS study included 1,789 patients with ACS who underwent LTA after clopidogrel loading. A post hoc cutoff value for HRPR was defined with the ROC curve and the Youden index and compared with the protocol-defined cutoff of 70 %. By ROC analysis, 63 % resulted the optimal cutoff value to predict both MACE and cardiac death at 2 years follow-up. A significant sensitivity improvement for the ROC-based cutoff value was noted (p < 0.001), at the price of lower specificity and predictive accuracy. The latter were 81 % for MACE and 85 % for cardiac death with the 70 % cutoff, while the respective figures were 73 and 75 % with the 63 % cutoff. The areas under the curve were virtually identical with the 70 and 63 % cutoffs both for MACE (0.71) and cardiac death (0.79). A residual platelet reactivity cutoff of 70 % by LTA, compared to the ROC-based cutoff of 63 %, allows for the identification of a subset of patients at very high risk of adverse ischemic events, making LTA-ADP test more acceptable in clinical practice for the identification of subjects at risk than other platelet function assays with broader definitions of HRPR.
- 1 October 2014
- Published by Elsevier in Thrombosis Research
- Vol. 134 (4) , 884-888
Global platelet hyperreactivity and elevated C-reactive protein levels predict long term mortality in STEMI patients
- 1 October 2014
- Published by Elsevier in Thrombosis Research
- Vol. 134 (4) , 884-888
Global platelet hyperreactivity and elevated C-reactive protein levels predict long term mortality in STEMI patients
- Open Access
- 1 January 2014
- Published by Baishideng Publishing Group Inc. in World Journal of Translational Medicine
- Vol. 3 (2) , 69-83
Assessment of platelet function: Laboratory and point-of-care methods
In the event of blood vessel damage, human platelets are promptly recruited on the site of injury and, after their adhesion, activation and aggregation, prevent blood loss with the formation of a clot. The consequence of abnormal regulation can be either hemorrhage or the development of thrombosis. Qualitative and/or quantitative defects in platelets promote bleeding, whereas the residual reactivity of platelets, despite antiplatelet therapies, play an important role in promoting arterial thrombotic complications. Platelet function is traditionally assessed to investigate the origin of a bleeding syndrome, to predict the risk of bleeding prior surgery or during pregnancy or to monitor the efficacy of antiplatelet therapy in thrombotic syndromes that, now, can be considered a new discipline. “Old” platelet function laboratory tests such as the evaluation of bleeding time and the platelet aggregation analysis in platelet-rich plasma are traditionally utilized to aid in the diagnosis and management of patients with platelet and hemostatic disorders and used as diagnostic tools both in bleeding and thrombotic diathesis in specialized laboratories. Now, new and renewed automated systems have been introduced to provide a simple, rapid assessment of platelet function including point of care methods. These new methodologies are also suitable for being used in non-specialized laboratories and in critical area for assessing platelet function in whole blood without the requirement of sample processing. Some of these methods are also beginning to be incorporated into routine clinical use and can be utilized as not only as first panel for the diagnosis of platelet dysfunction, but also for monitoring anti-platelet therapy and to potentially assess risk of both bleeding and/or thrombosis.
- 1 January 2014
- Published by Baishideng Publishing Group Inc. in World Journal of Translational Medicine
- Vol. 3 (2) , 69-83
Open AccessAssessment of platelet function: Laboratory and point-of-care methods
In the event of blood vessel damage, human platelets are promptly recruited on the site of injury and, after their adhesion, activation and aggregation, prevent blood loss with the formation of a clot. The consequence of abnormal regulation can be either hemorrhage or the development of thrombosis. Qualitative and/or quantitative defects in platelets promote bleeding, whereas the residual reactivity of platelets, despite antiplatelet therapies, play an important role in promoting arterial thrombotic complications. Platelet function is traditionally assessed to investigate the origin of a bleeding syndrome, to predict the risk of bleeding prior surgery or during pregnancy or to monitor the efficacy of antiplatelet therapy in thrombotic syndromes that, now, can be considered a new discipline. “Old” platelet function laboratory tests such as the evaluation of bleeding time and the platelet aggregation analysis in platelet-rich plasma are traditionally utilized to aid in the diagnosis and management of patients with platelet and hemostatic disorders and used as diagnostic tools both in bleeding and thrombotic diathesis in specialized laboratories. Now, new and renewed automated systems have been introduced to provide a simple, rapid assessment of platelet function including point of care methods. These new methodologies are also suitable for being used in non-specialized laboratories and in critical area for assessing platelet function in whole blood without the requirement of sample processing. Some of these methods are also beginning to be incorporated into routine clinical use and can be utilized as not only as first panel for the diagnosis of platelet dysfunction, but also for monitoring anti-platelet therapy and to potentially assess risk of both bleeding and/or thrombosis.
- 1 December 2013
- Published by Elsevier in Atherosclerosis
- Vol. 231 (2) , 392-400
Platelet and leukocyte ROS production and lipoperoxidation are associated with high platelet reactivity in Non-ST elevation myocardial infarction (NSTEMI) patients on dual antiplatelet treatment
- 1 December 2013
- Published by Elsevier in Atherosclerosis
- Vol. 231 (2) , 392-400
Platelet and leukocyte ROS production and lipoperoxidation are associated with high platelet reactivity in Non-ST elevation myocardial infarction (NSTEMI) patients on dual antiplatelet treatment