OBOsama Abdullah Bawazir

Osama Abdullah Bawazir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Osama Abdullah Bawazir has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Modified Clip-and-drop Technique Using LigaSure Device in the Management of Multifocal Necrotizing Enterocolitis

    by Osama A. Bawazir, Ohoud Mohammad Baajlan

    Introduction: Despite the acknowledgment in the previous decades and all the extensive studies of necrotizing enterocolitis (NEC), the controversy regarding this problem is still on-going and unsolved. It is a common gastrointestinal life-threatening emergency that occurs primarily in 90% of the preterm infants. Surgery is usually indicated in approximately 27%–52% of infants with NEC. Case 1: Full-term, birth weight of 3.2 kg. At 14 days old, he developed pneumoperitonea, at exploratory laparotomy, all the necrotic segments were sealed and divided using 5 mm LigaSure device. All the edges of the resected bowel were sealed and return in the abdominal cavity. At the second look surgery, assurance of bowel viability was established. The sealed bowel segments were completely closed. Case 2: A 33-week-old gestational age, of 2000 g. was operated upon at the age of 14 days for developing pneumoperitoneum. At exploration, there was evidence of extensive NEC involving the entire small intestine reaching to the cecum with multiple necrotic and perforated areas was found. All the segments of necrosis were resected using 5-mm LigaSure device. The small areas of perforation were patched. At second-look surgery, all the sealed bowel segments and the areas of patch perforation were viable, with good sealing without any complications. Anastomosis of the multiple resected segments was done with “Shish-Kebab” technique. Discussion: Multifocal NEC is a challenging spectrum of the disease for pediatric surgeon, as there are various surgical options in their management. LigaSure is an electrothermal sealing system that combines dissecting and reconstructing abilities in a single instrument, without the need to reload with each use. Thus, it reduces the cost as well as shorten the operative time as mentioned in the previous studies. In addition, it has the advantage over clips as they do not leave any metallics in the body, furthermore, the risk to damage the surrounding structures is less due to minimal thermal spread so limited injury, and it considers easy to use. Conclusion: LigaSure device is an effective and safe method in sealing small bowel in sick neonates with multifocal NEC if applied with single application and with minimal manipulation of the bowel and most importantly minimizing the operative time.

  • Open Access

    Single-Incision Open versus Laparoscopic Gastrostomy in Infants

    by Osama A. Bawazir, Ahmed Hasan Alamoudi

    Background: Gastrostomy tube can be inserted through a single incision without laparoscopic or endoscopic guidance. The superiority of this approach over the laparoscopic technique is still debated. Therefore, we aimed to compare single-incision open and laparoscopic gastrostomy in infants. Patients and Methods: We retrospectively reviewed paediatric patients aged 12 months or less who required enteral feeding between 2006 and 2019. Patients were grouped according to the technique into two groups. Group 1 (n = 42) included patients who had a single incision open gastrostomy, and Group 2 (n = 45) included patients who underwent laparoscopic gastrostomy. Results: The median age was 2 months (Q1-Q3: 1–4 months) in Group 1 and 5 months (3–6 months) in Group 2 (P < 0.001). Male presented 52.38% in Group 1 and 37.78% in Group 2 (P = 0.17). There were no differences in cardiac and neurological comorbidities between the groups. Operative time was significantly shorter in Group 1 (23 [20–25] vs. 40 [35–45] min; P < 0.001). There were no differences in the post-operative leak around the tube (P > 0.99), granulation tissue formation (P = 0.36), wound dehiscence (P = 0.61), surgical site infection (P > 0.99) and pneumonia (P = 0.10) between the groups. Conclusion: Single-incision open and laparoscopic gastrostomy could be effective and safe techniques in infants. The minimal anaesthesia without gas insufflation and short time for the open gastrostomy make it not inferior to laparoscopic gastrostomy and should be considered in small infants.


  • Open Access

    Bilateral Wilms’ Tumor With Different Responses to Preoperative Chemotherapy

    by Wadah Qari, Alyazid Alzahrani, Mohammed Alzahrani, Yasir Saleh, Abdulrahim Almasabi, Osama Bawazir

    Wilms’ tumor (WT) is a common type of primary renal tumor in the pediatric population that can equally affect both sides. Herein, we describe a case of bilateral Wilms’ tumor (BWT) in a three-year-old male with different responses to preoperative chemotherapy in the two kidneys. The left kidney mass responded poorly to chemotherapy than the right kidney, which raised the suspicion of coexisting benign disease or congenital anomaly. However, it was ruled out by preoperative nuclear scan and ultrasound-guided frozen section biopsy taken from the left kidney mass. The report of a frozen section on hematoxylin and eosin (H&E) stain was positive for the small blue cell tumor. The patient was managed successfully with a total nephrectomy of the right kidney and nephron-sparing surgery (NSS) on the left kidney. The postoperative period was uneventful and was managed successfully with radiotherapy. Despite many challenges faced in the management of bilateral Wilms’ tumor, surgery is the most preferable mode of therapy with chemotherapy and radiotherapy being effective in certain cases. The patient was followed up till no signs of recurrence or metastasis were observed.


  • Orchidopexy during inguinoscrotal hydrocele repair: is it necessary?

    by Osama A. Bawazir, Murad O. Alsaegh

    Article: Orchidopexy during inguinoscrotal hydrocele repair: is it necessary? - Chirurgia 2022 April;35(2):71-5 - Minerva Medica - Journals

  • Is it beneficial to approximate the hyoid bone during thyroglossal duct cyst excision?

    by Osama A. Bawazir, Abdullah Bawazir, Razan Bawazir, Ameen Alherabi

    Article: Is it beneficial to approximate the hyoid bone during thyroglossal duct cyst excision? - Chirurgia 2022 April;35(2):90-4 - Minerva Medica - Journals

  • Percutaneous endoscopic gastrostomy in children: A tertiary center experience

    by Osama Bawazir, Abdulaziz M Banaja, Razan Bawazir, Abdullah Osama Bawazir

    Introduction: Percutaneous endoscopic gastrostomy (PEG) is a common procedure in children. The outcomes of PEG could be affected by the associated disease. We aimed to evaluate the outcomes and safety of PEG tube placement in a tertiary care center with special attention to patients with cardiac disease, ventriculoperitoneal (VP) shunt, or peritoneal dialysis (PD) catheter.Methods: This retrospective study included 113 pediatric patients who had PEG tube insertion from 2011 to 2021. Eighteen patients (15.93%) had cardiac disease, five patients (4.42%) had PD catheters, and three patients (2.65%) had VP shunt.Results: The median age was 3 years (interquartile range: 1–6), and females represented 55% of our patients. The weight ranged from 2.57 to 60 kg, and the most common indication for insertion was neurological disease (n = 56; 49.56%). The median operative time was 30 (20–45) minutes. Pneumonia and vomiting were the most frequent complications (n = 20, 17.7%). Thirty‐day mortality occurred in four patients (3.54%) and 1‐year mortality in 10 patients (8.85%). Nine patients (7.96%) required fundoplication, and four patients (3.53%) had tube removal and reinsertion. There was no association between weight and postoperative complications (odds ratio: 0.97; P = .48). There were no differences in postoperative complications among patients with cardiac diseases, PD catheters, and VP shunts. No complications were reported in patients with VP shunt. One patient with cardiac disease and one patient with PD catheter required fundoplication. Removal and reinsertion were needed in one patient with a PD catheter.Conclusion: PEG is feasible in low‐weight infants with a low complication rate. The complication rate is low in patients with VP shunt, PD catheter, and cardiac patients.


  • Open Access

    Introduction to the first issue of Saudi Medical Horizons Journal

    by Osama Bawazir

    Introduction to the first issue of Saudi Medical Horizons Journal

  • Open Access

    Is the simple webbed penis a contraindication to circumcision?

    by Osama Abdullah Bawazir, Obada Alladh Alhallaq, Bashair Albayhani, Abdullah Bawazir

    Background: Surgical correction of the webbed penis is challenging. We presented the safety and feasibility of webbed penis correction for neonates under local anesthesia using a simple principle of leaving equal cylindrical shaft skin.Methods: This retrospective study included 530 patients who presented for circumcision to three pediatric surgery centers between May 2017 and January 2020. We included male patients aged less than four weeks old who had circumcision with a minimum of 6 months follow-up. We compared patients with normal penile anatomy (n = 451, Group 1) to a simple webbed penis (n = 79, Group 2).Results: There were no differences in age and weight between groups. The procedure time was significantly longer in Group 2 (8.05 ± 3.11 vs. 7.48 ± 2.07 min;P = 0.04). There were no differences in bleeding (P = 0.38), redundant foreskin (P > 0.99), need for corrective surgery (P = 0.38), and re-suturing (P = 0.28) between groups. The procedure success was significantly higher in Group 1 (449 (99.56%) vs. 70 (88.6%);P < 0.001). Parents' satisfaction was measured at two weeks with no difference between both groups.Conclusion: Simple penoscrotal web is not a contraindication for neonatal circumcision. Circumcision of the penoscrotal web had good esthetic results with comparable outcomes to those with a normal penis without a web.

  • Open Access

    Ultrasound guidance for Port-A-Cath insertion in children; a comparative study

    by Osama A. Bawazir, Abdullah Bawazir

    Background: Gaining vascular access in children is challenging. Ultrasound-guided central line insertion in adults became the standard of care; however, its role in children is not clear. Our objective was to evaluate the ultrasound-guided Port-A-Cath or totally implanted long-term venous access device insertion in pediatric patients compared to the traditional approach. Methods: This single-institution retrospective cohort study included 169 children who had port-A-catheters between May 2016 and Oct 2019. The patients were divided into two groups; group A included patients who had Port-A-Cath insertion using the landmark method (n = 117), and Group B included patients who had ultrasound-guided Port-A-Cath insertion (n = 52). Preoperative, operative, and postoperative data were collected and compared between the two groups. The study outcomes were operative time and catheter insertion-related complications. Results: There was no significant difference in age or gender between both groups (P = .33 and .71, respectively). Eleven cases in group A and two cases in group B were converted to cut down technique because of difficulty in inserting the guidewire. There was no difference in the indication of the need for the port-A-Cath between both groups. The mean operative time for group A was 47 min and for group B was 41.7 min (P < .042). Two patients had intraoperative bleeding and hemothorax and required blood transfusion and chest tube insertion in group A. No statistically significant difference was found in the reported complications between the groups. However, the insertion-related complications were higher in group A (P = .053). No procedure-related mortality was reported. Conclusions: Ultrasound-guided insertion of Port-A-Cath is an effective and safe technique with a reduction of failure rate. It should be considered the standard technique for Port-A-Cath insertion in the pediatric population.