Richard J. van Arkel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard J. van Arkel has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Justin Peter Cobb
MSK Lab, Imperial College London, London, UK
9 shared publications - Amy Garner
MSk Lab, Sir Michael Uren Biomedical Engineering Research Hub, Imperial College London, London, UK
7 shared publications - Oliver W. Dandridge
Department of Mechanical Engineering, Imperial College London, London, UK
7 shared publications - Andrew A. Amis
Biomechanics Group, Mechanical Engineering Department, Imperial College, London, United Kingdom
6 shared publications - Jonathan R. T. Jeffers
Department of Mechanical Engineering, Imperial College London, London, UK
4 shared publications Nupur Kohli
Biomechanics Group, , , London, United Kingdom
4 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (13) , 3171-3180
Lateral Tibial Posterior Slope Induces Anterior Tibial Translation While Lateral-Medial Slope Difference Induces Internal Rotation: A Cadaveric Biomechanical Study
Background: Posterior tibial slope (PTS) influences tibiofemoral kinematics and anterior cruciate ligament (ACL) function. While previous studies have evaluated symmetrical slope modifications, the isolated influences of the medial or lateral PTS remain unclear. This study investigated the influence of medial and lateral PTS changes on anterior tibial translation (ATT) and internal rotation (IR) under axial loading, using unicondylar slope-changing osteotomies. Hypothesis: Increased lateral PTS increases ATT, while a greater delta PTS (lateral minus medial PTS) increases IR. Study Design: Controlled laboratory study. Methods: Eight fresh-frozen knee specimens were mounted in a custom-built fixture in a compression/torsion loading machine. Tibiofemoral translation/rotation kinematics were measured under a 500-N axial compression load at 0° and 20° of knee flexion using optical motion tracking. Unicondylar tibial slope-changing osteotomies were performed on the medial and lateral tibial plateaus with a custom cutting guide, preserving key ligament and meniscus root attachments. Medial and lateral PTS were independently adjusted to −5°, 0°, +5°, and +10°, resulting in medial and lateral PTS ranging from −5° to +10°, using 3-dimensionally printed wedges. Repeated-measures analyses of variance, post hoc t tests, and Pearson correlations were used for analysis. Results: An increase of +10° in lateral PTS significantly increased ATT ( P = .012), while increasing medial PTS did not ( P > .99). IR was most influenced by delta PTS. At 0° of flexion, altering lateral or medial PTS alone was insufficient to significantly change rotation, but changing delta PTS +10° produced 7.6° more rotation ( P = .015). At 20° of flexion, changing individual slopes ±10° significantly increased/decreased rotation ( P < .036). The largest rotational differences correlated with opposing delta PTS values ( r = 0.960; P = .0006). Conclusion: Lateral PTS was the principal determinant of ATT, whereas delta PTS was the principal determinant of IR under axial loading. Clinical Relevance: Understanding the independent biomechanical roles of the medial and lateral PTS provides insight into mechanisms of anterior and rotational instability in ACL injury and reconstruction. These findings suggest the potential utility of differential correction of PTS as a novel surgical approach for optimizing tibiofemoral rotational kinematics.
- 22 September 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (13) , 3171-3180
Open AccessLateral Tibial Posterior Slope Induces Anterior Tibial Translation While Lateral-Medial Slope Difference Induces Internal Rotation: A Cadaveric Biomechanical Study
Background: Posterior tibial slope (PTS) influences tibiofemoral kinematics and anterior cruciate ligament (ACL) function. While previous studies have evaluated symmetrical slope modifications, the isolated influences of the medial or lateral PTS remain unclear. This study investigated the influence of medial and lateral PTS changes on anterior tibial translation (ATT) and internal rotation (IR) under axial loading, using unicondylar slope-changing osteotomies. Hypothesis: Increased lateral PTS increases ATT, while a greater delta PTS (lateral minus medial PTS) increases IR. Study Design: Controlled laboratory study. Methods: Eight fresh-frozen knee specimens were mounted in a custom-built fixture in a compression/torsion loading machine. Tibiofemoral translation/rotation kinematics were measured under a 500-N axial compression load at 0° and 20° of knee flexion using optical motion tracking. Unicondylar tibial slope-changing osteotomies were performed on the medial and lateral tibial plateaus with a custom cutting guide, preserving key ligament and meniscus root attachments. Medial and lateral PTS were independently adjusted to −5°, 0°, +5°, and +10°, resulting in medial and lateral PTS ranging from −5° to +10°, using 3-dimensionally printed wedges. Repeated-measures analyses of variance, post hoc t tests, and Pearson correlations were used for analysis. Results: An increase of +10° in lateral PTS significantly increased ATT ( P = .012), while increasing medial PTS did not ( P > .99). IR was most influenced by delta PTS. At 0° of flexion, altering lateral or medial PTS alone was insufficient to significantly change rotation, but changing delta PTS +10° produced 7.6° more rotation ( P = .015). At 20° of flexion, changing individual slopes ±10° significantly increased/decreased rotation ( P < .036). The largest rotational differences correlated with opposing delta PTS values ( r = 0.960; P = .0006). Conclusion: Lateral PTS was the principal determinant of ATT, whereas delta PTS was the principal determinant of IR under axial loading. Clinical Relevance: Understanding the independent biomechanical roles of the medial and lateral PTS provides insight into mechanisms of anterior and rotational instability in ACL injury and reconstruction. These findings suggest the potential utility of differential correction of PTS as a novel surgical approach for optimizing tibiofemoral rotational kinematics.
- Open Access
- 14 July 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Knee joint line obliquity alters lateral meniscal root tension, tibiofemoral subluxation and compartment-specific contact pressures.
The objective was to measure effects of joint line obliquity (JLO) on meniscus posterior root tension, tibiofemoral subluxation and contact pressures. It was hypothesised that a medial JLO would increase medial meniscal (MM) root tension, medial tibiofemoral subluxation and medial compartment contact pressure, and vice versa for lateral downslope. Eight knees were mounted in a compression machine with JLO from 16° medial to 12° lateral downslope. The loading axis was aligned to the centre of the tibial plateau, while JLO was altered by tilting the tibial plateau relative to the loading axis. Subluxation was measured optically. Sub-meniscal sensors measured contact pressures. The posterior MM or lateral meniscus (LM) root was transected and repaired using transosseous suture tapes attached to a tensiometer. The repair was tightened 30 N, then the tension measured at 2× body weight load. This was repeated for each JLO and both menisci, at 0° and 20° flexion. Data analyses used Shapiro-Wilk tests, RM-ANOVA and RM-t post-tests. 2× body weight load (1.48 ± 0.30kN) caused posterior root tensions higher at 20° flexion than 0°: MM 83 ± 15 N and 64 ± 9 N (p < 0.001), LM 75 ± 16 N and 63 ± 13 N (p = 0.006). Changing JLO at 20° flexion from 16° medial to 12° lateral caused 5.4 mm subluxation and increased LM root tension: 55 ± 14 N to 81 ± 12 N (p = 0.016). JLO did not affect MM tension significantly. Medial JLO did not increase medial compartment articular pressure; the lateral compartment saw reduced pressure with lateral JLO. JLO affected lateral compartment contact stresses, but less than meniscal root transection. Beyond 8° lateral JLO the LM root tension was above that with native 4° medial downslope. Root repairs restored contact pressures following root transection. Excessive lateral JLO may influence contact mechanics and meniscal loading. This should be considered during surgical planning of osteotomies. Level N/A, controlled laboratory study.
- 14 July 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Open AccessKnee joint line obliquity alters lateral meniscal root tension, tibiofemoral subluxation and compartment-specific contact pressures.
The objective was to measure effects of joint line obliquity (JLO) on meniscus posterior root tension, tibiofemoral subluxation and contact pressures. It was hypothesised that a medial JLO would increase medial meniscal (MM) root tension, medial tibiofemoral subluxation and medial compartment contact pressure, and vice versa for lateral downslope. Eight knees were mounted in a compression machine with JLO from 16° medial to 12° lateral downslope. The loading axis was aligned to the centre of the tibial plateau, while JLO was altered by tilting the tibial plateau relative to the loading axis. Subluxation was measured optically. Sub-meniscal sensors measured contact pressures. The posterior MM or lateral meniscus (LM) root was transected and repaired using transosseous suture tapes attached to a tensiometer. The repair was tightened 30 N, then the tension measured at 2× body weight load. This was repeated for each JLO and both menisci, at 0° and 20° flexion. Data analyses used Shapiro-Wilk tests, RM-ANOVA and RM-t post-tests. 2× body weight load (1.48 ± 0.30kN) caused posterior root tensions higher at 20° flexion than 0°: MM 83 ± 15 N and 64 ± 9 N (p < 0.001), LM 75 ± 16 N and 63 ± 13 N (p = 0.006). Changing JLO at 20° flexion from 16° medial to 12° lateral caused 5.4 mm subluxation and increased LM root tension: 55 ± 14 N to 81 ± 12 N (p = 0.016). JLO did not affect MM tension significantly. Medial JLO did not increase medial compartment articular pressure; the lateral compartment saw reduced pressure with lateral JLO. JLO affected lateral compartment contact stresses, but less than meniscal root transection. Beyond 8° lateral JLO the LM root tension was above that with native 4° medial downslope. Root repairs restored contact pressures following root transection. Excessive lateral JLO may influence contact mechanics and meniscal loading. This should be considered during surgical planning of osteotomies. Level N/A, controlled laboratory study.
- Open Access
- 7 January 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (7)
Lattice Structures for Bone Replacement: The Intersection of Bone Biomechanics, Lattice Design, and Additive Manufacturing
Additive manufacturing (AM) has enabled the development of highly porous orthopedic implants by incorporating lattice structures that mimic the micro‐architecture of natural bone. Lattices can be tuned to replicate bone's mechanical properties, creating implants that preserve the bone environment and allow bone formation within lattice pores. This review examines the intersection of bone biology, lattice design, and AM technologies to guide the development of such biomimetic structures. The hierarchical structure, mechanical properties, anisotropy, and heterogeneity of bone are identified as critical factors influencing bone remodeling, which is regulated by mechanical stimuli and can inform lattice design. Lattice mechanical behavior can be tailored through base material, relative density, topology, anisotropy, and size, which in turn affect biological responses, including cell function, tissue growth, and vascularization. Among available AM methods, powder bed fusion demonstrates the greatest capacity for producing complex geometries with high precision and reproducibility. Post‐processing techniques, such as surface and thermal treatments and biomimetic coatings, are increasingly recognized as crucial for enhancing mechanical and biological performance. Still, current clinical and preclinical applications underscore remaining challenges in improving fatigue life, implant stabilization, vascularization, and bioactivity. This review provides a framework for advancing the design and clinical translation of lattice‐based orthopedic implants.
- 7 January 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (7)
Open AccessLattice Structures for Bone Replacement: The Intersection of Bone Biomechanics, Lattice Design, and Additive Manufacturing
Additive manufacturing (AM) has enabled the development of highly porous orthopedic implants by incorporating lattice structures that mimic the micro‐architecture of natural bone. Lattices can be tuned to replicate bone's mechanical properties, creating implants that preserve the bone environment and allow bone formation within lattice pores. This review examines the intersection of bone biology, lattice design, and AM technologies to guide the development of such biomimetic structures. The hierarchical structure, mechanical properties, anisotropy, and heterogeneity of bone are identified as critical factors influencing bone remodeling, which is regulated by mechanical stimuli and can inform lattice design. Lattice mechanical behavior can be tailored through base material, relative density, topology, anisotropy, and size, which in turn affect biological responses, including cell function, tissue growth, and vascularization. Among available AM methods, powder bed fusion demonstrates the greatest capacity for producing complex geometries with high precision and reproducibility. Post‐processing techniques, such as surface and thermal treatments and biomimetic coatings, are increasingly recognized as crucial for enhancing mechanical and biological performance. Still, current clinical and preclinical applications underscore remaining challenges in improving fatigue life, implant stabilization, vascularization, and bioactivity. This review provides a framework for advancing the design and clinical translation of lattice‐based orthopedic implants.
- Open Access
- 5 March 2025
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 9 (1) , e66464
Exploring Stakeholder Perspectives on the Barriers and Facilitators of Implementing Digital Technologies for Heart Disease Diagnosis: Qualitative Study
Background: Digital technologies are increasingly being implemented in health care to improve the quality and efficiency of care for patients. However, the rapid adoption of health technologies over the last 5 years has failed to adequately consider patient and clinician needs, which results in ineffective implementation. There is also a lack of consideration for the differences between patient and clinician needs, resulting in overgeneralized approaches to the implementation and use of digital health technologies. Objective: This study aimed to explore barriers and facilitators of the implementation of digital technologies in the diagnosis of heart disease for both patients and clinicians, and to provide recommendations to increase the acceptability of novel health technologies. Methods: We recruited 32 participants from across the United Kingdom, including 23 (72%) individuals with lived experience of heart disease and 9 (28%) clinicians involved in diagnosing heart disease. Participants with experience of living with heart disease took part in semistructured focused groups, while clinicians contributed to one-to-one semistructured interviews. Inductive thematic analysis using a phenomenological approach was conducted to analyze the resulting qualitative data and to identify themes. Results were discussed with a cardiovascular patient advisory group to enhance the rigor of our interpretation of the data. Results: Emerging themes were separated into facilitators and barriers and categorized into resource-, technology-, and user-related themes. Resource-related barriers and facilitators related to concerns around increased clinician workload, the high cost of digital technologies, and systemic limitations within health care systems such as outdated equipment and limited support. Technology-related barriers and facilitators included themes related to reliability, accuracy, safety parameters, data security, ease of use, and personalization, all of which can impact engagement and trust with digital technologies. Finally, the most prominent themes were the user-related barriers and facilitators, which encompassed user attitudes, individual-level variation in preferences and capabilities, and impact on quality of health care experiences. This theme captured a wide variety of perspectives among the sample and revealed how patient and clinician attitudes and personal experiences substantially impact engagement with digital health technologies across the cardiovascular care pathway. Conclusions: Our findings highlight the importance of considering both patient and clinician needs and preferences when investigating the barriers and facilitators to effective implementation of digital health technologies. Facilitators to technology adoption include the need for cost-effective, accurate, reliable, and easy-to-use systems as well as adequate setup support and personalization to meet individual needs. Positive user attitudes, perceived improvement in care quality, and increased involvement in the care process also enhance engagement. While both clinicians and patients acknowledge the potential benefits of digital technologies, effective implementation hinges on addressing these barriers and leveraging facilitators to ensure that the technologies are perceived as useful, safe, and supportive of health care outcomes. International Registered Report Identifier (IRRID): RR2-10.1136/bmjopen-2023-072952
- 5 March 2025
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 9 (1) , e66464
Open AccessExploring Stakeholder Perspectives on the Barriers and Facilitators of Implementing Digital Technologies for Heart Disease Diagnosis: Qualitative Study
Background: Digital technologies are increasingly being implemented in health care to improve the quality and efficiency of care for patients. However, the rapid adoption of health technologies over the last 5 years has failed to adequately consider patient and clinician needs, which results in ineffective implementation. There is also a lack of consideration for the differences between patient and clinician needs, resulting in overgeneralized approaches to the implementation and use of digital health technologies. Objective: This study aimed to explore barriers and facilitators of the implementation of digital technologies in the diagnosis of heart disease for both patients and clinicians, and to provide recommendations to increase the acceptability of novel health technologies. Methods: We recruited 32 participants from across the United Kingdom, including 23 (72%) individuals with lived experience of heart disease and 9 (28%) clinicians involved in diagnosing heart disease. Participants with experience of living with heart disease took part in semistructured focused groups, while clinicians contributed to one-to-one semistructured interviews. Inductive thematic analysis using a phenomenological approach was conducted to analyze the resulting qualitative data and to identify themes. Results were discussed with a cardiovascular patient advisory group to enhance the rigor of our interpretation of the data. Results: Emerging themes were separated into facilitators and barriers and categorized into resource-, technology-, and user-related themes. Resource-related barriers and facilitators related to concerns around increased clinician workload, the high cost of digital technologies, and systemic limitations within health care systems such as outdated equipment and limited support. Technology-related barriers and facilitators included themes related to reliability, accuracy, safety parameters, data security, ease of use, and personalization, all of which can impact engagement and trust with digital technologies. Finally, the most prominent themes were the user-related barriers and facilitators, which encompassed user attitudes, individual-level variation in preferences and capabilities, and impact on quality of health care experiences. This theme captured a wide variety of perspectives among the sample and revealed how patient and clinician attitudes and personal experiences substantially impact engagement with digital health technologies across the cardiovascular care pathway. Conclusions: Our findings highlight the importance of considering both patient and clinician needs and preferences when investigating the barriers and facilitators to effective implementation of digital health technologies. Facilitators to technology adoption include the need for cost-effective, accurate, reliable, and easy-to-use systems as well as adequate setup support and personalization to meet individual needs. Positive user attitudes, perceived improvement in care quality, and increased involvement in the care process also enhance engagement. While both clinicians and patients acknowledge the potential benefits of digital technologies, effective implementation hinges on addressing these barriers and leveraging facilitators to ensure that the technologies are perceived as useful, safe, and supportive of health care outcomes. International Registered Report Identifier (IRRID): RR2-10.1136/bmjopen-2023-072952
- Open Access
- 13 September 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Exploring Stakeholder Perspectives on the Barriers and Facilitators of Implementing Digital Technologies for Heart Disease Diagnosis: Qualitative Study (Preprint)
BACKGROUND Digital technologies are increasingly being implemented in health care to improve the quality and efficiency of care for patients. However, the rapid adoption of health technologies over the last 5 years has failed to adequately consider patient and clinician needs, which results in ineffective implementation. There is also a lack of consideration for the differences between patient and clinician needs, resulting in overgeneralized approaches to the implementation and use of digital health technologies. OBJECTIVE This study aimed to explore barriers and facilitators of the implementation of digital technologies in the diagnosis of heart disease for both patients and clinicians, and to provide recommendations to increase the acceptability of novel health technologies. METHODS We recruited 32 participants from across the United Kingdom, including 23 (72%) individuals with lived experience of heart disease and 9 (28%) clinicians involved in diagnosing heart disease. Participants with experience of living with heart disease took part in semistructured focused groups, while clinicians contributed to one-to-one semistructured interviews. Inductive thematic analysis using a phenomenological approach was conducted to analyze the resulting qualitative data and to identify themes. Results were discussed with a cardiovascular patient advisory group to enhance the rigor of our interpretation of the data. RESULTS Emerging themes were separated into facilitators and barriers and categorized into resource-, technology-, and user-related themes. Resource-related barriers and facilitators related to concerns around increased clinician workload, the high cost of digital technologies, and systemic limitations within health care systems such as outdated equipment and limited support. Technology-related barriers and facilitators included themes related to reliability, accuracy, safety parameters, data security, ease of use, and personalization, all of which can impact engagement and trust with digital technologies. Finally, the most prominent themes were the user-related barriers and facilitators, which encompassed user attitudes, individual-level variation in preferences and capabilities, and impact on quality of health care experiences. This theme captured a wide variety of perspectives among the sample and revealed how patient and clinician attitudes and personal experiences substantially impact engagement with digital health technologies across the cardiovascular care pathway. CONCLUSIONS Our findings highlight the importance of considering both patient and clinician needs and preferences when investigating the barriers and facilitators to effective implementation of digital health technologies. Facilitators to technology adoption include the need for cost-effective, accurate, reliable, and easy-to-use systems as well as adequate setup support and personalization to meet individual needs. Positive user attitudes, perceived improvement in care quality, and increased involvement in the care process also enhance engagement. While both clinicians and patients acknowledge the potential benefits of digital technologies, effective implementation hinges on addressing these barriers and leveraging facilitators to ensure that the technologies are perceived as useful, safe, and supportive of health care outcomes. INTERNATIONAL REGISTERED REPORT RR2-10.1136/bmjopen-2023-072952
- 13 September 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessExploring Stakeholder Perspectives on the Barriers and Facilitators of Implementing Digital Technologies for Heart Disease Diagnosis: Qualitative Study (Preprint)
BACKGROUND Digital technologies are increasingly being implemented in health care to improve the quality and efficiency of care for patients. However, the rapid adoption of health technologies over the last 5 years has failed to adequately consider patient and clinician needs, which results in ineffective implementation. There is also a lack of consideration for the differences between patient and clinician needs, resulting in overgeneralized approaches to the implementation and use of digital health technologies. OBJECTIVE This study aimed to explore barriers and facilitators of the implementation of digital technologies in the diagnosis of heart disease for both patients and clinicians, and to provide recommendations to increase the acceptability of novel health technologies. METHODS We recruited 32 participants from across the United Kingdom, including 23 (72%) individuals with lived experience of heart disease and 9 (28%) clinicians involved in diagnosing heart disease. Participants with experience of living with heart disease took part in semistructured focused groups, while clinicians contributed to one-to-one semistructured interviews. Inductive thematic analysis using a phenomenological approach was conducted to analyze the resulting qualitative data and to identify themes. Results were discussed with a cardiovascular patient advisory group to enhance the rigor of our interpretation of the data. RESULTS Emerging themes were separated into facilitators and barriers and categorized into resource-, technology-, and user-related themes. Resource-related barriers and facilitators related to concerns around increased clinician workload, the high cost of digital technologies, and systemic limitations within health care systems such as outdated equipment and limited support. Technology-related barriers and facilitators included themes related to reliability, accuracy, safety parameters, data security, ease of use, and personalization, all of which can impact engagement and trust with digital technologies. Finally, the most prominent themes were the user-related barriers and facilitators, which encompassed user attitudes, individual-level variation in preferences and capabilities, and impact on quality of health care experiences. This theme captured a wide variety of perspectives among the sample and revealed how patient and clinician attitudes and personal experiences substantially impact engagement with digital health technologies across the cardiovascular care pathway. CONCLUSIONS Our findings highlight the importance of considering both patient and clinician needs and preferences when investigating the barriers and facilitators to effective implementation of digital health technologies. Facilitators to technology adoption include the need for cost-effective, accurate, reliable, and easy-to-use systems as well as adequate setup support and personalization to meet individual needs. Positive user attitudes, perceived improvement in care quality, and increased involvement in the care process also enhance engagement. While both clinicians and patients acknowledge the potential benefits of digital technologies, effective implementation hinges on addressing these barriers and leveraging facilitators to ensure that the technologies are perceived as useful, safe, and supportive of health care outcomes. INTERNATIONAL REGISTERED REPORT RR2-10.1136/bmjopen-2023-072952
- Open Access
- 14 July 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 263, 116571
Wireless implantable bioelectronics with a direct electron transfer lactate enzyme for detection of surgical site infection in orthopaedics
- 14 July 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 263, 116571
Open AccessWireless implantable bioelectronics with a direct electron transfer lactate enzyme for detection of surgical site infection in orthopaedics
- Open Access
- 10 July 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 32 (12) , 3133-3140
Femorotibial angle scan–rescan reproducibility: A high‐precision calculation on a large cohort
Purpose: Femorotibial angle (FTA) is a convenient measure of coronal knee alignment that can be extracted from a short knee radiograph, avoiding the additional radiation exposure and specialist equipment required for full‐leg radiographs. While intra‐ and inter‐reader reproducibility from the same image has been reported, the full scan–rescan reproducibility across images, as calculated in this study, has not.Methods: In this study, 4589 FTA measurement pairs from 2586 subjects acquired a year apart were used to estimate FTA scan–rescan reproducibility using data from the Osteoarthritis Initiative. Subjects with radiographic progression of osteoarthritis or other conditions that may cause a change in coronal knee alignment were excluded. Measurement pairs were analysed using paired‐samples tests to detect differences and compared to symptomatic changes in Western Ontario and McMaster Universities Arthritis Index scores for joint pain, stiffness and physical function to detect correlations.Results: The 95% limit of agreement and the paired‐samples correlation were calculated with high precision to be [−1.76°, +1.78°] and 0.938, considerably worse than the corresponding figures for intra‐ and inter‐reader reproducibility, without relation to symptomatic or radiographic changes in knee condition. This error will weakly attenuate and values from their true values in correlative studies involving FTA. The realistic maximum value for is 87% and for Pearson's is 93%.Conclusion: The scan–rescan reproducibility in FTA is almost double the intra‐ and inter‐reader reliability from a single scan. At almost ±2° accuracy, FTA is inappropriate for surgical use, but it is sufficiently reproducible to produce good correlations in studies predicting disease incidence and progression.Level of Evidence: Level II, retrospective study.
- 10 July 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 32 (12) , 3133-3140
Open AccessFemorotibial angle scan–rescan reproducibility: A high‐precision calculation on a large cohort
Purpose: Femorotibial angle (FTA) is a convenient measure of coronal knee alignment that can be extracted from a short knee radiograph, avoiding the additional radiation exposure and specialist equipment required for full‐leg radiographs. While intra‐ and inter‐reader reproducibility from the same image has been reported, the full scan–rescan reproducibility across images, as calculated in this study, has not.Methods: In this study, 4589 FTA measurement pairs from 2586 subjects acquired a year apart were used to estimate FTA scan–rescan reproducibility using data from the Osteoarthritis Initiative. Subjects with radiographic progression of osteoarthritis or other conditions that may cause a change in coronal knee alignment were excluded. Measurement pairs were analysed using paired‐samples tests to detect differences and compared to symptomatic changes in Western Ontario and McMaster Universities Arthritis Index scores for joint pain, stiffness and physical function to detect correlations.Results: The 95% limit of agreement and the paired‐samples correlation were calculated with high precision to be [−1.76°, +1.78°] and 0.938, considerably worse than the corresponding figures for intra‐ and inter‐reader reproducibility, without relation to symptomatic or radiographic changes in knee condition. This error will weakly attenuate and values from their true values in correlative studies involving FTA. The realistic maximum value for is 87% and for Pearson's is 93%.Conclusion: The scan–rescan reproducibility in FTA is almost double the intra‐ and inter‐reader reliability from a single scan. At almost ±2° accuracy, FTA is inappropriate for surgical use, but it is sufficiently reproducible to produce good correlations in studies predicting disease incidence and progression.Level of Evidence: Level II, retrospective study.
- Open Access
- 6 May 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (8) , 1108-1121
An Optimization Approach for Creating Application-specific Ultrasound Speckle Tracking Algorithms
- 6 May 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (8) , 1108-1121
Open AccessAn Optimization Approach for Creating Application-specific Ultrasound Speckle Tracking Algorithms
- Open Access
- 22 March 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1360669
Active osseointegration in an ex vivo porcine bone model
Achieving osseointegration is a fundamental requirement for many orthopaedic, oral, and craniofacial implants. Osseointegration typically takes three to 6 months, during which time implants are at risk of loosening. The aim of this study was to investigate whether osseointegration could be actively enhanced by delivering controllable electromechanical stimuli to the periprosthetic bone. First, the osteoconductivity of the implant surface was confirmed using an in vitro culture with murine preosteoblasts. The effects of active treatment on osseointegration were then investigated in a 21-day ex vivo model with freshly harvested cancellous bone cylinders (n = 24; Ø10 mm × 5 mm) from distal porcine femora, with comparisons to specimens treated by a distant ultrasound source and static controls. Cell viability, proliferation and distribution was evident throughout culture. Superior ongrowth of tissue onto the titanium discs during culture was observed in the actively stimulated specimens, with evidence of ten-times increased mineralisation after 7 and 14 days of culture (p < 0.05) and 2.5 times increased expression of osteopontin (p < 0.005), an adhesive protein, at 21 days. Moreover, histological analyses revealed increased bone remodelling at the implant-bone interface in the actively stimulated specimens compared to the passive controls. Active osseointegration is an exciting new approach for accelerating bone growth into and around implants.
- 22 March 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1360669
Open AccessActive osseointegration in an ex vivo porcine bone model
Achieving osseointegration is a fundamental requirement for many orthopaedic, oral, and craniofacial implants. Osseointegration typically takes three to 6 months, during which time implants are at risk of loosening. The aim of this study was to investigate whether osseointegration could be actively enhanced by delivering controllable electromechanical stimuli to the periprosthetic bone. First, the osteoconductivity of the implant surface was confirmed using an in vitro culture with murine preosteoblasts. The effects of active treatment on osseointegration were then investigated in a 21-day ex vivo model with freshly harvested cancellous bone cylinders (n = 24; Ø10 mm × 5 mm) from distal porcine femora, with comparisons to specimens treated by a distant ultrasound source and static controls. Cell viability, proliferation and distribution was evident throughout culture. Superior ongrowth of tissue onto the titanium discs during culture was observed in the actively stimulated specimens, with evidence of ten-times increased mineralisation after 7 and 14 days of culture (p < 0.05) and 2.5 times increased expression of osteopontin (p < 0.005), an adhesive protein, at 21 days. Moreover, histological analyses revealed increased bone remodelling at the implant-bone interface in the actively stimulated specimens compared to the passive controls. Active osseointegration is an exciting new approach for accelerating bone growth into and around implants.
- Open Access
- 8 March 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1274496
Load transfer in bone after partial, multi-compartmental, and total knee arthroplasty
Introduction: Arthroplasty-associated bone loss remains a clinical problem: stiff metallic implants disrupt load transfer to bone and, hence, its remodeling stimulus. The aim of this research was to analyze how load transfer to bone is affected by different forms of knee arthroplasty: isolated partial knee arthroplasty (PKA), compartmental arthroplasty [combined partial knee arthroplasty (CPKA), two or more PKAs in the same knee], and total knee arthroplasty (TKA).Methods: An experimentally validated subject-specific finite element model was analyzed native and with medial unicondylar, lateral unicondylar, patellofemoral, bi-unicondylar, medial bicompartmental, lateral bicompartmental, tricompartmental, and total knee arthroplasty. Three load cases were simulated for each: gait, stair ascent, and sit-to-stand. Strain shielding and overstraining were calculated from the differences between the native and implanted states.Results: For gait, the TKA femoral component led to mean strain shielding (30%) more than three times higher than that of PKA (4%–7%) and CPKA (5%–8%). Overstraining was predicted in the proximal tibia (TKA 21%; PKA/CPKA 0%–6%). The variance in the distribution for TKA was an order of magnitude greater than for PKA/CPKA, indicating less physiological load transfer. Only the TKA-implanted femur was sensitive to the load case: for stair ascent and gait, almost the entire distal femur was strain-shielded, whereas during sit-to-stand, the posterior femoral condyles were overstrained.Discussion: TKA requires more bone resection than PKA and CPKA. These finite element analyses suggest that a longer-term benefit for bone is probable as partial and multi-compartmental knee procedures lead to more natural load transfer compared to TKA. High-flexion activity following TKA may be protective of posterior condyle bone resorption, which may help explain why bone loss affects some patients more than others. The male and female bone models used for this research are provided open access to facilitate future research elsewhere.
- 8 March 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1274496
Open AccessLoad transfer in bone after partial, multi-compartmental, and total knee arthroplasty
Introduction: Arthroplasty-associated bone loss remains a clinical problem: stiff metallic implants disrupt load transfer to bone and, hence, its remodeling stimulus. The aim of this research was to analyze how load transfer to bone is affected by different forms of knee arthroplasty: isolated partial knee arthroplasty (PKA), compartmental arthroplasty [combined partial knee arthroplasty (CPKA), two or more PKAs in the same knee], and total knee arthroplasty (TKA).Methods: An experimentally validated subject-specific finite element model was analyzed native and with medial unicondylar, lateral unicondylar, patellofemoral, bi-unicondylar, medial bicompartmental, lateral bicompartmental, tricompartmental, and total knee arthroplasty. Three load cases were simulated for each: gait, stair ascent, and sit-to-stand. Strain shielding and overstraining were calculated from the differences between the native and implanted states.Results: For gait, the TKA femoral component led to mean strain shielding (30%) more than three times higher than that of PKA (4%–7%) and CPKA (5%–8%). Overstraining was predicted in the proximal tibia (TKA 21%; PKA/CPKA 0%–6%). The variance in the distribution for TKA was an order of magnitude greater than for PKA/CPKA, indicating less physiological load transfer. Only the TKA-implanted femur was sensitive to the load case: for stair ascent and gait, almost the entire distal femur was strain-shielded, whereas during sit-to-stand, the posterior femoral condyles were overstrained.Discussion: TKA requires more bone resection than PKA and CPKA. These finite element analyses suggest that a longer-term benefit for bone is probable as partial and multi-compartmental knee procedures lead to more natural load transfer compared to TKA. High-flexion activity following TKA may be protective of posterior condyle bone resorption, which may help explain why bone loss affects some patients more than others. The male and female bone models used for this research are provided open access to facilitate future research elsewhere.