Matteo Scaramuzza
Research Subjects
Matteo Scaramuzza has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Elisabetta Pasqualotto
University of Padova
11 shared publications A. De Toni
10 shared publicationsA. Paccagnella
8 shared publications- Alessandro Paccagnella
University of Padova
8 shared publications - Alberto Ferrario
ICMATE CNR, Corso Stati Uniti, 4, Padova, Veneto, 35127, ITALY
6 shared publications - Giulio Rosati
Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, Barcelona 08193, Spain
6 shared publications
Latest Publications
- Open Access
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (6) , 1-4
Bacteria-Based Biosensor for the Detection of Lactococcus Lactis Bacteriophage in Agrifood Industry
This study explores and clarifies the sensing mechanism of a proposed biosensor designed for the rapid detection of the phages of Lactococcus lactis in milk-based solutions. A dedicated experimental test revealed that the increased charge transfer resistance visible when L. lactis proliferates in solution results from both bacterial electrode coverage and direct bacterial interaction with redox species, most likely related to Fe(CN6)3- consumption during L. lactis metabolism. Finally, the evaluation of biosensor performance through impedance phase shift analysis at 100 Hz offers a simplified approach for practical applications. The biosensor demonstrates efficient phage detection within 4 hours with detection capabilities for phage concentrations >103 PFU/mL, and future work aims to validate its on-field applicability in authentic milk samples.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (6) , 1-4
Open AccessBacteria-Based Biosensor for the Detection of Lactococcus Lactis Bacteriophage in Agrifood Industry
This study explores and clarifies the sensing mechanism of a proposed biosensor designed for the rapid detection of the phages of Lactococcus lactis in milk-based solutions. A dedicated experimental test revealed that the increased charge transfer resistance visible when L. lactis proliferates in solution results from both bacterial electrode coverage and direct bacterial interaction with redox species, most likely related to Fe(CN6)3- consumption during L. lactis metabolism. Finally, the evaluation of biosensor performance through impedance phase shift analysis at 100 Hz offers a simplified approach for practical applications. The biosensor demonstrates efficient phage detection within 4 hours with detection capabilities for phage concentrations >103 PFU/mL, and future work aims to validate its on-field applicability in authentic milk samples.
- Open Access
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (1) , 78-85
Electrochemical Biosensor for the Monitoring of Phages of Lactococcus lactis in Milk-Based Samples
Lactococcus lactis bacteriophage infections in milk prevent the proper lactic fermentation, leading to the production of unsaleable low-quality products and great economic losses in the dairy industry. In this work, we present an innovative biosensing approach for the cost-effective detection of L. lactis phages in milk-based samples through electrochemical impedance spectroscopy (EIS). The detection is based on the evident parametric shifts in the charge transfer resistance and in the impedance phase at 100 Hz caused by different bacteria proliferation due to phage activity. The EIS results are compared with optical absorbance measurements at 600 nm, in order to validate the proposed method. Preliminary experimental tests with filtered milk-based samples confirm the sensor capability to detect phages at different concentrations in milk-based solutions in less than 4 hours. In order to reach a higher sensitivity, we propose a new milk pre-treatment adding calcium chloride (CaCl 2 ) to the samples. The EIS results with CaCl 2 -treated milk evidence an enhanced phage activity, which leads to a much larger parametric shift. Lastly, the sensor is tested with CaCl 2 -treated milk-based samples at different phages concentrations, obtaining an enhanced performance reaching the limit of detection of 10 3 PFU/mL.
- 21 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (1) , 78-85
Open AccessElectrochemical Biosensor for the Monitoring of Phages of Lactococcus lactis in Milk-Based Samples
Lactococcus lactis bacteriophage infections in milk prevent the proper lactic fermentation, leading to the production of unsaleable low-quality products and great economic losses in the dairy industry. In this work, we present an innovative biosensing approach for the cost-effective detection of L. lactis phages in milk-based samples through electrochemical impedance spectroscopy (EIS). The detection is based on the evident parametric shifts in the charge transfer resistance and in the impedance phase at 100 Hz caused by different bacteria proliferation due to phage activity. The EIS results are compared with optical absorbance measurements at 600 nm, in order to validate the proposed method. Preliminary experimental tests with filtered milk-based samples confirm the sensor capability to detect phages at different concentrations in milk-based solutions in less than 4 hours. In order to reach a higher sensitivity, we propose a new milk pre-treatment adding calcium chloride (CaCl 2 ) to the samples. The EIS results with CaCl 2 -treated milk evidence an enhanced phage activity, which leads to a much larger parametric shift. Lastly, the sensor is tested with CaCl 2 -treated milk-based samples at different phages concentrations, obtaining an enhanced performance reaching the limit of detection of 10 3 PFU/mL.
- Open Access
SPECTRA: A Novel Compact System for Surface Plasmon Resonance Measurements
Surface plasmon resonance (SPR) is a common and useful measurement technique to perform fast and sensitive optical detection. SPR instrumentations usually comprise optical systems of mirrors and lenses which are quite expensive and impractical for point-of-care applications. In this work, we presented a novel and compact SPR device called SPECTRA, designed as a spectrophotometer add-on with a grating coupling configuration. The device is conceived as a marketable solution to perform quick SPR measurements in grating configuration without the requirement of complex instrumentation. The device can be customized either in a vertical structure to reach lower incident light angles, or in a horizontal configuration, which is suitable for SPR analysis using liquid solutions. The SPECTRA performance was evaluated through SPR measurements in typical applications. The vertical SPECTRA system was employed to detect different functionalization molecules on gold 720 nm-period grating devices. Meanwhile, the horizontal SPECTRA configuration was exploited to carry out fluid-dynamic measurements using a microfluidic cell with glycerol solutions at increasing concentrations to account for different refractive indexes. The experimental tests confirmed that the SPECTRA design is suitable for SPR measurements, demonstrating its capability to detect the presence of analytes and changes in surface properties both in static and dynamic set-ups.
Open AccessSPECTRA: A Novel Compact System for Surface Plasmon Resonance Measurements
Surface plasmon resonance (SPR) is a common and useful measurement technique to perform fast and sensitive optical detection. SPR instrumentations usually comprise optical systems of mirrors and lenses which are quite expensive and impractical for point-of-care applications. In this work, we presented a novel and compact SPR device called SPECTRA, designed as a spectrophotometer add-on with a grating coupling configuration. The device is conceived as a marketable solution to perform quick SPR measurements in grating configuration without the requirement of complex instrumentation. The device can be customized either in a vertical structure to reach lower incident light angles, or in a horizontal configuration, which is suitable for SPR analysis using liquid solutions. The SPECTRA performance was evaluated through SPR measurements in typical applications. The vertical SPECTRA system was employed to detect different functionalization molecules on gold 720 nm-period grating devices. Meanwhile, the horizontal SPECTRA configuration was exploited to carry out fluid-dynamic measurements using a microfluidic cell with glycerol solutions at increasing concentrations to account for different refractive indexes. The experimental tests confirmed that the SPECTRA design is suitable for SPR measurements, demonstrating its capability to detect the presence of analytes and changes in surface properties both in static and dynamic set-ups.
- Open Access
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (6) , 5552-5560
Screen-Printed Electrochemical Biosensor for the Detection of Bacteriophage of Lactococcus Lactis for Dairy Production
In the dairy industry, the spreading of phages of Lactococcus lactis prevent the proper lactic fermentation, causing waste of contaminated products and economic losses. This work presents a cheap biosensing method for rapidly detecting the L.lactis phages. The detection is based on live L. lactis bacteria covering the sensor electrodes, whose electrical response is measured by electrochemical impedance spectroscopy (EIS). Solutions contaminated by phages induce bacteria lysis, clearly reducing the bacteria coverage over the electrodes and leading to evident parametrical shifts in the charge transfer resistance and in the impedance phase at 400 Hz. Experimental tests with laboratory contaminated samples confirm that screen-printed sensors with gold and detection capability compared to interdigitated gold electrodes. Two measurement protocols, called spill-out and drop-in methods, are evaluated to optimize the sensor detection capability and time. The EIS results are compared with optical absorbance measurements at 600 nm, in order to validate the proposed detection method with 10 7 PFU/mL phages and with a detection time of about 5 hours. Lastly, the proposed method is tested successfully with milk-based solutions. Evident shifts are measured in the charge transfer resistance of more than one order of magnitude and impedance phase differences of 43° in phages contaminated sensors.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (6) , 5552-5560
Open AccessScreen-Printed Electrochemical Biosensor for the Detection of Bacteriophage of Lactococcus Lactis for Dairy Production
In the dairy industry, the spreading of phages of Lactococcus lactis prevent the proper lactic fermentation, causing waste of contaminated products and economic losses. This work presents a cheap biosensing method for rapidly detecting the L.lactis phages. The detection is based on live L. lactis bacteria covering the sensor electrodes, whose electrical response is measured by electrochemical impedance spectroscopy (EIS). Solutions contaminated by phages induce bacteria lysis, clearly reducing the bacteria coverage over the electrodes and leading to evident parametrical shifts in the charge transfer resistance and in the impedance phase at 400 Hz. Experimental tests with laboratory contaminated samples confirm that screen-printed sensors with gold and detection capability compared to interdigitated gold electrodes. Two measurement protocols, called spill-out and drop-in methods, are evaluated to optimize the sensor detection capability and time. The EIS results are compared with optical absorbance measurements at 600 nm, in order to validate the proposed detection method with 10 7 PFU/mL phages and with a detection time of about 5 hours. Lastly, the proposed method is tested successfully with milk-based solutions. Evident shifts are measured in the charge transfer resistance of more than one order of magnitude and impedance phase differences of 43° in phages contaminated sensors.
- Open Access
- 25 November 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1079
Optical System Based on Nafion Membrane for the Detection of Ammonia in Blood Serum Samples
The blood ammonia (NH3) level is one of the most important hepatic biomarkers for the diagnosis and monitoring of liver pathologies and infections. In this work, we developed an optimized optical biosensing method to extract and quantify the ammonia contained in complex-matrix samples emulating the blood serum. First, the approach was tested with solutions of phosphate-buffered saline (PBS) and ammonia chloride. Then, further trials were carried out with solutions of fetal bovine serum (FBS). The ammonia was extracted from the tested samples through a customized cell, and it was optically quantified by exploiting the indophenol reaction. The extraction cell included a cation-exchange membrane in Nafion, which was chemically pre-treated through cleaning procedures of sulfuric acid and hydrogen peroxide to keep a basic pH in the ammonia solution and to avoid contaminants in the membrane. From the NH3 solution, the indophenol reaction produced light-reactive indophenol dye molecules, which were used as colorimetric indicators. Through absorbance measurements of the indophenol dye solution at 670 nm wavelength, we were able to detect and quantify the ammonia level in the samples both with a spectrophotometer and a customized miniaturized read-out system, obtaining a detection limit of 0.029 µmol/mL.
- 25 November 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1079
Open AccessOptical System Based on Nafion Membrane for the Detection of Ammonia in Blood Serum Samples
The blood ammonia (NH3) level is one of the most important hepatic biomarkers for the diagnosis and monitoring of liver pathologies and infections. In this work, we developed an optimized optical biosensing method to extract and quantify the ammonia contained in complex-matrix samples emulating the blood serum. First, the approach was tested with solutions of phosphate-buffered saline (PBS) and ammonia chloride. Then, further trials were carried out with solutions of fetal bovine serum (FBS). The ammonia was extracted from the tested samples through a customized cell, and it was optically quantified by exploiting the indophenol reaction. The extraction cell included a cation-exchange membrane in Nafion, which was chemically pre-treated through cleaning procedures of sulfuric acid and hydrogen peroxide to keep a basic pH in the ammonia solution and to avoid contaminants in the membrane. From the NH3 solution, the indophenol reaction produced light-reactive indophenol dye molecules, which were used as colorimetric indicators. Through absorbance measurements of the indophenol dye solution at 670 nm wavelength, we were able to detect and quantify the ammonia level in the samples both with a spectrophotometer and a customized miniaturized read-out system, obtaining a detection limit of 0.029 µmol/mL.
- Open Access
- 1 November 2019
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 26, 100308
Inkjet sensors produced by consumer printers with smartphone impedance readout
- 1 November 2019
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 26, 100308
Open AccessInkjet sensors produced by consumer printers with smartphone impedance readout
- Open Access
- 18 February 2019
- Published by MDPI AG in Chemosensors
- Vol. 7 (1) , 8
Inkjet Printed Interdigitated Biosensor for Easy and Rapid Detection of Bacteriophage Contamination: A Preliminary Study for Milk Processing Control Applications
Bacteriophages are responsible for significant material and time losses in the dairy industry. This because these viruses infect the selected lactic starter cultures used for milk fermentation, i.e., the first stage toward cheese production. Standard detection techniques are time- and labor-consuming, causing huge costs related to production plant sanitation and product wasting. A new type of biosensor for early detection of bacteriophage contamination is highly demanded by the milk processing market, and inkjet-printed electrochemical sensors could be the answer. Inkjet printing is a well-known technology that has been revisited in recent years, using silver nanoparticle (AgNP) based inks for low-cost and easy fabrication of sensing and biosensing systems on flexible and eco-compatible substrates. In this research, we studied inkjet printing for the manufacturing of both interdigitated electrodes arrays (IDEAs), and a versatile system to monitor bacterial cultures by electrochemical impedance spectroscopy (EIS). In particular, we studied this biosensing system for the detection of bacteriophages by comparing its performance with standard microbiological methods. We performed electrical and morphological characterizations of the devices produced with a consumer-use inkjet printer with commercial AgNPs ink on flexible substrates, such as office paper, polyethylene (PET), and photo paper. We used light microscopy optical analysis, profilometry, atomic force microscopy (AFM), and scanning electron microscopy (SEM) imaging to define the objects resolution, their real dimensions, and thickness. We also investigated the devices’ conductivity and layout, by EIS measurements with a standard buffer solution, i.e., phosphate buffered saline (PBS). Finally, we tested our system by monitoring Lactococcus lactis cultures and bacteriophage infection. We compared the results to those obtained by two standard microbiological methods in terms of response time, proving that our technique requires less than half the time of other methods and no specialized personnel.
- 18 February 2019
- Published by MDPI AG in Chemosensors
- Vol. 7 (1) , 8
Open AccessInkjet Printed Interdigitated Biosensor for Easy and Rapid Detection of Bacteriophage Contamination: A Preliminary Study for Milk Processing Control Applications
Bacteriophages are responsible for significant material and time losses in the dairy industry. This because these viruses infect the selected lactic starter cultures used for milk fermentation, i.e., the first stage toward cheese production. Standard detection techniques are time- and labor-consuming, causing huge costs related to production plant sanitation and product wasting. A new type of biosensor for early detection of bacteriophage contamination is highly demanded by the milk processing market, and inkjet-printed electrochemical sensors could be the answer. Inkjet printing is a well-known technology that has been revisited in recent years, using silver nanoparticle (AgNP) based inks for low-cost and easy fabrication of sensing and biosensing systems on flexible and eco-compatible substrates. In this research, we studied inkjet printing for the manufacturing of both interdigitated electrodes arrays (IDEAs), and a versatile system to monitor bacterial cultures by electrochemical impedance spectroscopy (EIS). In particular, we studied this biosensing system for the detection of bacteriophages by comparing its performance with standard microbiological methods. We performed electrical and morphological characterizations of the devices produced with a consumer-use inkjet printer with commercial AgNPs ink on flexible substrates, such as office paper, polyethylene (PET), and photo paper. We used light microscopy optical analysis, profilometry, atomic force microscopy (AFM), and scanning electron microscopy (SEM) imaging to define the objects resolution, their real dimensions, and thickness. We also investigated the devices’ conductivity and layout, by EIS measurements with a standard buffer solution, i.e., phosphate buffered saline (PBS). Finally, we tested our system by monitoring Lactococcus lactis cultures and bacteriophage infection. We compared the results to those obtained by two standard microbiological methods in terms of response time, proving that our technique requires less than half the time of other methods and no specialized personnel.
- 1 February 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 280, 280-289
Silver nanoparticles inkjet-printed flexible biosensor for rapid label-free antibiotic detection in milk
- 1 February 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 280, 280-289
Silver nanoparticles inkjet-printed flexible biosensor for rapid label-free antibiotic detection in milk
- Open Access
- 1 November 2018
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 21, 54-64
Lactate Dehydrogenase and Glutamate Pyruvate Transaminase biosensing strategies for lactate detection on screen-printed sensors. Catalysis efficiency and interference analysis in complex matrices: from cell cultures to sport medicine
- 1 November 2018
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 21, 54-64
Open AccessLactate Dehydrogenase and Glutamate Pyruvate Transaminase biosensing strategies for lactate detection on screen-printed sensors. Catalysis efficiency and interference analysis in complex matrices: from cell cultures to sport medicine
- 9 September 2017
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 103-110
Optimization of Cyclic Voltammetric Curve Parameters to Measure Lactate Concentration in Urine Samples
- 9 September 2017
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 103-110
Optimization of Cyclic Voltammetric Curve Parameters to Measure Lactate Concentration in Urine Samples