Peter Fischer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peter Fischer has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Maier
Friedrich-Alexander-Universität Erlangen-Nürnberg
6 shared publications Joachim Hornegger
Pattern Recognition Lab and the Erlangen Graduate School in Advanced Optical Technologies, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
6 shared publicationsThomas Pohl
Siemens Healthcare GmbH, Forchheim, Germany
5 shared publicationsAndreas Maier
Graduate School in Advanced Optical Technologies (SAOT), 91058 Erlangen, Germany
2 shared publicationsAnja Borsdorf
Siemens Healthineers AG, 91301 Forchheim, Germany
2 shared publicationsAnthony Faranesh
National Institutes of Health, Bethesda, MD, USA
2 shared publications
Latest Publications
- Open Access
- 20 November 2025
- Published by Scientific Scholar in Journal of Clinical Imaging Science
- Vol. 15, 43
Improving cone-beam computed tomography image quality for transarterial therapy of liver malignancies: Evaluation of a motion correction algorithm with and without automated bone removal
Objectives: The objectives of the study are to compare the effect on image quality of a motion artifact correction algorithm (CAVAREC) alone versus in combination with an automated bone removal algorithm (ZIBOS) for motion-degraded intraprocedural liver cone-beam computed tomography (CBCT) images. Material and Methods: In this retrospective, two-center, Institutional Review Board (IRB)-approved study, 48 CBCTs from 41 patients were included. Inclusion criteria were (a) age ≥18; (b) liver CBCT with contrast injected at the main, right, or left hepatic artery; and (c) CBCT motion-degraded. Exclusion criteria were (a) no visible tumor and (b) CBCT not capturing the entire liver. The mean (standard deviation [SD]) age was 64 (7) years, 81% male. 65% had hepatocellular carcinoma and 35% metastatic cancer. 69% CBCTs were from transarterial radioembolization (TARE) mapping, 25% transarterial chemoembolization, and 6% TARE treatment. Mean (SD) maximum tumor diameter was 4.6 (2.7) cm. CBCT images were processed with CAVAREC (prototype, Siemens Healthineers AG, Forchheim, Germany) and CAVAREC + ZIBOS (work in progress, Comprehenso, Hannover, Germany). Using CoroEval, sharpness for two segmental arteries per case was obtained quantitatively. Three blinded interventional radiologists independently evaluated overall image quality on a 0–100 scale and large vessels, small vessels, vessel sharpness, tumor feeders, tumor blush, and streak artifacts on a −50 to +50 scale relative to uncorrected images. Results were analyzed with paired t- tests and Wilcoxon signed-rank tests, adjusting P -values with the Benjamini–Hochberg procedure. Results: On quantitative assessment, mean (SD) sharpness for uncorrected, CAVAREC, and CAVAREC + ZIBOS (C+Z) images was 0.281 (0.04), 0.287 (0.04), and 0.284 (0.04), respectively, P = 0.02 for uncorrected versus CAVAREC and P > 0.05 for other comparisons. On qualitative assessment, mean (SD) overall quality for uncorrected, CAVAREC, and C+Z images was 45 (14), 53 (16), and 53 (17), respectively, P < 0.001 for both uncorrected versus CAVAREC and uncorrected versus C+Z and P = 0.06 for CAVAREC versus C+Z. The mean preference for both CAVAREC and C+Z compared to uncorrected images for all parameters ranged from +4.3 to +9.5, P < 0.001, except tumor blush which was +1.6 for CAVAREC and +0.9 for C+Z, P > 0.05. CAVAREC versus C+Z was not significant for any parameter. Conclusion: Motion artifact correction of liver CBCT images using CAVAREC improves image quality significantly. According to observer studies, integrating the automated bone segmentation algorithm ZIBOS with CAVAREC does not degrade image quality.
- 20 November 2025
- Published by Scientific Scholar in Journal of Clinical Imaging Science
- Vol. 15, 43
Open AccessImproving cone-beam computed tomography image quality for transarterial therapy of liver malignancies: Evaluation of a motion correction algorithm with and without automated bone removal
Objectives: The objectives of the study are to compare the effect on image quality of a motion artifact correction algorithm (CAVAREC) alone versus in combination with an automated bone removal algorithm (ZIBOS) for motion-degraded intraprocedural liver cone-beam computed tomography (CBCT) images. Material and Methods: In this retrospective, two-center, Institutional Review Board (IRB)-approved study, 48 CBCTs from 41 patients were included. Inclusion criteria were (a) age ≥18; (b) liver CBCT with contrast injected at the main, right, or left hepatic artery; and (c) CBCT motion-degraded. Exclusion criteria were (a) no visible tumor and (b) CBCT not capturing the entire liver. The mean (standard deviation [SD]) age was 64 (7) years, 81% male. 65% had hepatocellular carcinoma and 35% metastatic cancer. 69% CBCTs were from transarterial radioembolization (TARE) mapping, 25% transarterial chemoembolization, and 6% TARE treatment. Mean (SD) maximum tumor diameter was 4.6 (2.7) cm. CBCT images were processed with CAVAREC (prototype, Siemens Healthineers AG, Forchheim, Germany) and CAVAREC + ZIBOS (work in progress, Comprehenso, Hannover, Germany). Using CoroEval, sharpness for two segmental arteries per case was obtained quantitatively. Three blinded interventional radiologists independently evaluated overall image quality on a 0–100 scale and large vessels, small vessels, vessel sharpness, tumor feeders, tumor blush, and streak artifacts on a −50 to +50 scale relative to uncorrected images. Results were analyzed with paired t- tests and Wilcoxon signed-rank tests, adjusting P -values with the Benjamini–Hochberg procedure. Results: On quantitative assessment, mean (SD) sharpness for uncorrected, CAVAREC, and CAVAREC + ZIBOS (C+Z) images was 0.281 (0.04), 0.287 (0.04), and 0.284 (0.04), respectively, P = 0.02 for uncorrected versus CAVAREC and P > 0.05 for other comparisons. On qualitative assessment, mean (SD) overall quality for uncorrected, CAVAREC, and C+Z images was 45 (14), 53 (16), and 53 (17), respectively, P < 0.001 for both uncorrected versus CAVAREC and uncorrected versus C+Z and P = 0.06 for CAVAREC versus C+Z. The mean preference for both CAVAREC and C+Z compared to uncorrected images for all parameters ranged from +4.3 to +9.5, P < 0.001, except tumor blush which was +1.6 for CAVAREC and +0.9 for C+Z, P > 0.05. CAVAREC versus C+Z was not significant for any parameter. Conclusion: Motion artifact correction of liver CBCT images using CAVAREC improves image quality significantly. According to observer studies, integrating the automated bone segmentation algorithm ZIBOS with CAVAREC does not degrade image quality.
- 20 February 2024
- Published by Springer Nature
- p. 279-284
Evaluation of Semi-automatic Segmentation of Liver Tumors for Intra-procedural Planning
- 20 February 2024
- Published by Springer Nature
- p. 279-284
Evaluation of Semi-automatic Segmentation of Liver Tumors for Intra-procedural Planning
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (10) , 3159-3174
Learning an Attention Model for Robust 2-D/3-D Registration Using Point-To-Plane Correspondences
Minimally invasive procedures rely on image guidance for navigation at the operation site to avoid large surgical incisions. images are often used for guidance, but important structures may be not well visible. These structures can be overlaid from pre-operative images and accurate alignment can be established using registration. Registration based on the point-to-plane correspondence model was recently proposed and shown to achieve performance. However, registration may still fail in challenging cases due to a large portion of outliers. In this paper, we describe a correspondence weighting scheme to improve the registration performance. By learning an attention model, inlier correspondences get higher attention in the motion estimation while the outlier correspondences are suppressed. Instead of using per-correspondence labels, our objective function allows to train the model directly by minimizing the registration error. We demonstrate a highly increased robustness, e.g. increasing the success rate from 84.9 % to 97.0 % for spine registration. In contrast to previously proposed methods, we also achieve a high accuracy of around 0.5 mm mean re-projection distance. In addition, our method requires a relatively small amount of training data, is able to learn from simulated data, and generalizes to images with additional structures which are not present during training. Furthermore, a single model can be trained for both, different views and different anatomical structures.
- 16 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (10) , 3159-3174
Learning an Attention Model for Robust 2-D/3-D Registration Using Point-To-Plane Correspondences
Minimally invasive procedures rely on image guidance for navigation at the operation site to avoid large surgical incisions. images are often used for guidance, but important structures may be not well visible. These structures can be overlaid from pre-operative images and accurate alignment can be established using registration. Registration based on the point-to-plane correspondence model was recently proposed and shown to achieve performance. However, registration may still fail in challenging cases due to a large portion of outliers. In this paper, we describe a correspondence weighting scheme to improve the registration performance. By learning an attention model, inlier correspondences get higher attention in the motion estimation while the outlier correspondences are suppressed. Instead of using per-correspondence labels, our objective function allows to train the model directly by minimizing the registration error. We demonstrate a highly increased robustness, e.g. increasing the success rate from 84.9 % to 97.0 % for spine registration. In contrast to previously proposed methods, we also achieve a high accuracy of around 0.5 mm mean re-projection distance. In addition, our method requires a relatively small amount of training data, is able to learn from simulated data, and generalizes to images with additional structures which are not present during training. Furthermore, a single model can be trained for both, different views and different anatomical structures.
- 14 February 2019
- Published by Springer Nature
- p. 140-152
Metric-Driven Learning of Correspondence Weighting for 2-D/3-D Image Registration
- 14 February 2019
- Published by Springer Nature
- p. 140-152
Metric-Driven Learning of Correspondence Weighting for 2-D/3-D Image Registration
- Open Access
- 30 November 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 56
Rapid Interactive and Intuitive Segmentation of 3D Medical Images Using Radial Basis Function Interpolation
Segmentation is one of the most important parts of medical image analysis. Manual segmentation is very cumbersome, time-consuming, and prone to inter-observer variability. Fully automatic segmentation approaches require a large amount of labeled training data and may fail in difficult or abnormal cases. In this work, we propose a new method for 2D segmentation of individual slices and 3D interpolation of the segmented slices. The Smart Brush functionality quickly segments the region of interest in a few 2D slices. Given these annotated slices, our adapted formulation of Hermite radial basis functions reconstructs the 3D surface. Effective interactions with less number of equations accelerate the performance and, therefore, a real-time and an intuitive, interactive segmentation of 3D objects can be supported effectively. The proposed method is evaluated on 12 clinical 3D magnetic resonance imaging data sets and are compared to gold standard annotations of the left ventricle from a clinical expert. The automatic evaluation of the 2D Smart Brush resulted in an average Dice coefficient of 0.88 ± 0.09 for the individual slices. For the 3D interpolation using Hermite radial basis functions, an average Dice coefficient of 0.94 ± 0.02 is achieved.
- 30 November 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 56
Open AccessRapid Interactive and Intuitive Segmentation of 3D Medical Images Using Radial Basis Function Interpolation
Segmentation is one of the most important parts of medical image analysis. Manual segmentation is very cumbersome, time-consuming, and prone to inter-observer variability. Fully automatic segmentation approaches require a large amount of labeled training data and may fail in difficult or abnormal cases. In this work, we propose a new method for 2D segmentation of individual slices and 3D interpolation of the segmented slices. The Smart Brush functionality quickly segments the region of interest in a few 2D slices. Given these annotated slices, our adapted formulation of Hermite radial basis functions reconstructs the 3D surface. Effective interactions with less number of equations accelerate the performance and, therefore, a real-time and an intuitive, interactive segmentation of 3D objects can be supported effectively. The proposed method is evaluated on 12 clinical 3D magnetic resonance imaging data sets and are compared to gold standard annotations of the left ventricle from a clinical expert. The automatic evaluation of the 2D Smart Brush resulted in an average Dice coefficient of 0.88 ± 0.09 for the individual slices. For the 3D interpolation using Hermite radial basis functions, an average Dice coefficient of 0.94 ± 0.02 is achieved.
- 4 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (1) , 47-60
An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy
In X-ray fluoroscopy, static overlays are used to visualize soft tissue. We propose a system for cardiac and respiratory motion compensation of these overlays. It consists of a 3-D motion model created from real-time magnetic resonance (MR) imaging. Multiple sagittal slices are acquired and retrospectively stacked to consistent 3-D volumes. Slice stacking considers cardiac information derived from the ECG and respiratory information extracted from the images. Additionally, temporal smoothness of the stacking is enhanced. Motion is estimated from the MR volumes using deformable 3-D/3-D registration. The motion model itself is a linear direct correspondence model using the same surrogate signals as slice stacking. In X-ray fluoroscopy, only the surrogate signals need to be extracted to apply the motion model and animate the overlay in real time. For evaluation, points are manually annotated in oblique MR slices and in contrast-enhanced X-ray images. The 2-D Euclidean distance of these points is reduced from 3.85 to 2.75 mm in MR and from 3.0 to 1.8 mm in X-ray compared with the static baseline. Furthermore, the motion-compensated overlays are shown qualitatively as images and videos.
- 4 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (1) , 47-60
An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy
In X-ray fluoroscopy, static overlays are used to visualize soft tissue. We propose a system for cardiac and respiratory motion compensation of these overlays. It consists of a 3-D motion model created from real-time magnetic resonance (MR) imaging. Multiple sagittal slices are acquired and retrospectively stacked to consistent 3-D volumes. Slice stacking considers cardiac information derived from the ECG and respiratory information extracted from the images. Additionally, temporal smoothness of the stacking is enhanced. Motion is estimated from the MR volumes using deformable 3-D/3-D registration. The motion model itself is a linear direct correspondence model using the same surrogate signals as slice stacking. In X-ray fluoroscopy, only the surrogate signals need to be extracted to apply the motion model and animate the overlay in real time. For evaluation, points are manually annotated in oblique MR slices and in contrast-enhanced X-ray images. The 2-D Euclidean distance of these points is reduced from 3.85 to 2.75 mm in MR and from 3.0 to 1.8 mm in X-ray compared with the static baseline. Furthermore, the motion-compensated overlays are shown qualitatively as images and videos.
- 16 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 36 (4) , 865-877
Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy
Respiratory signals are required for image gating and motion compensation in minimally invasive interventions. In X-ray fluoroscopy, extraction of a respiratory signal can be challenging due to characteristics of interventional imaging, in particular injection of contrast agent and automatic exposure control. We present a novel method for respiratory signal extraction based on dimensionality reduction that can tolerate these events. Images are divided into patches of multiple sizes. Low-dimensional embeddings are generated for each patch using illumination-invariant kernel PCA. Patches with respiratory information are selected automatically by agglomerative clustering. The signals from this respiratory cluster are combined robustly to a single respiratory signal. In the experiments, we evaluate our method on a variety of scenarios. If the diaphragm is visible, we track its superior-inferior motion as ground truth. Our method has a correlation coefficient of more than 91% with the ground truth irrespective of whether or not contrast agent injection or automatic exposure control occur. Additionally, we show that very similar signals are estimated from biplane sequences and from sequences without visible diaphragm. Since all these cases are handled automatically, the method is robust enough to be considered for use in a clinical setting.
- 16 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 36 (4) , 865-877
Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy
Respiratory signals are required for image gating and motion compensation in minimally invasive interventions. In X-ray fluoroscopy, extraction of a respiratory signal can be challenging due to characteristics of interventional imaging, in particular injection of contrast agent and automatic exposure control. We present a novel method for respiratory signal extraction based on dimensionality reduction that can tolerate these events. Images are divided into patches of multiple sizes. Low-dimensional embeddings are generated for each patch using illumination-invariant kernel PCA. Patches with respiratory information are selected automatically by agglomerative clustering. The signals from this respiratory cluster are combined robustly to a single respiratory signal. In the experiments, we evaluate our method on a variety of scenarios. If the diaphragm is visible, we track its superior-inferior motion as ground truth. Our method has a correlation coefficient of more than 91% with the ground truth irrespective of whether or not contrast agent injection or automatic exposure control occur. Additionally, we show that very similar signals are estimated from biplane sequences and from sequences without visible diaphragm. Since all these cases are handled automatically, the method is robust enough to be considered for use in a clinical setting.
- 18 November 2015
- Published by Springer Nature
- p. 282-289
Surrogate-Driven Estimation of Respiratory Motion and Layers in X-Ray Fluoroscopy
- 18 November 2015
- Published by Springer Nature
- p. 282-289
Surrogate-Driven Estimation of Respiratory Motion and Layers in X-Ray Fluoroscopy
- 23 June 2015
- Published by Springer Nature
- Vol. 24, 288-299
A Robust Probabilistic Model for Motion Layer Separation in X-ray Fluoroscopy
Fluoroscopic images are characterized by a transparent projection of 3-D structures from all depths to 2-D. Differently moving structures, for example due to breathing and heartbeat, can be described approximately using independently moving 2-D layers. Separating the fluoroscopic images into the motion layers is desirable to facilitate interpretation and diagnosis. Given the motion of each layer, it is state of the art to compute the layer separation by minimizing a least-squares objective function. However, due to high noise levels and inaccurate motion estimates, the results are not satisfactory in X-ray images. In this work, we propose a probabilistic model for motion layer separation. In this model, we analyze various data terms and regularization terms theoretically and experimentally. We show that a robust penalty function is required in the data term to deal with noise and shortcomings of the image formation model. For the regularization term, we propose to enforce smoothness of the layers using bilateral total variation. On synthetic data, the mean squared error between the estimated layers and the ground truth is improved by \(18\,\%\) compared to the state of the art. In addition, we show qualitative improvements on real X-ray data.- 23 June 2015
- Published by Springer Nature
- Vol. 24, 288-299
A Robust Probabilistic Model for Motion Layer Separation in X-ray Fluoroscopy
Fluoroscopic images are characterized by a transparent projection of 3-D structures from all depths to 2-D. Differently moving structures, for example due to breathing and heartbeat, can be described approximately using independently moving 2-D layers. Separating the fluoroscopic images into the motion layers is desirable to facilitate interpretation and diagnosis. Given the motion of each layer, it is state of the art to compute the layer separation by minimizing a least-squares objective function. However, due to high noise levels and inaccurate motion estimates, the results are not satisfactory in X-ray images. In this work, we propose a probabilistic model for motion layer separation. In this model, we analyze various data terms and regularization terms theoretically and experimentally. We show that a robust penalty function is required in the data term to deal with noise and shortcomings of the image formation model. For the regularization term, we propose to enforce smoothness of the layers using bilateral total variation. On synthetic data, the mean squared error between the estimated layers and the ground truth is improved by \(18\,\%\) compared to the state of the art. In addition, we show qualitative improvements on real X-ray data.- 25 February 2015
- Published by Springer Nature
- p. 329-334
Markov Random Field-Based Layer Separation for Simulated X-Ray Image Sequences
- 25 February 2015
- Published by Springer Nature
- p. 329-334
Markov Random Field-Based Layer Separation for Simulated X-Ray Image Sequences