Julia Attias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Julia Attias has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Bjoern Braunstein
Institute of Movement and Neuroscience, German Sport University Cologne, Cologne, Germany
3 shared publications - Tobias Weber
European Astronaut Centre (EAC), European Space Agency, Space Medicine Team (HRE-OM), Cologne, Germany
3 shared publications Alexander Suess
European Astronaut Centre (EAC), European Space Agency, Space Medicine Team (HRE-OM), Cologne, Germany
2 shared publications- Charlotte Richter
Department of Medical Engineering and Technomathematics, University of Applied Sciences Aachen, Aachen, Germany
2 shared publications - David Andrew Green
Centre of Human & Applied Physiological Sciences (CHAPS) King's College London London UK
2 shared publications - Jörn Rittweger
Institute of Aerospace Medicine, German Aerospace Center, Cologne, Germany
2 shared publications
Latest Publications
- Open Access
- 19 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-13
Gastrocnemius medialis contractile behavior during running differs between simulated Lunar and Martian gravities
The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.
- 19 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-13
Open AccessGastrocnemius medialis contractile behavior during running differs between simulated Lunar and Martian gravities
The international partnership of space agencies has agreed to proceed forward to the Moon sustainably. Activities on the Lunar surface (0.16 g) will allow crewmembers to advance the exploration skills needed when expanding human presence to Mars (0.38 g). Whilst data from actual hypogravity activities are limited to the Apollo missions, simulation studies have indicated that ground reaction forces, mechanical work, muscle activation, and joint angles decrease with declining gravity level. However, these alterations in locomotion biomechanics do not necessarily scale to the gravity level, the reduction in gastrocnemius medialis activation even appears to level off around 0.2 g, while muscle activation pattern remains similar. Thus, it is difficult to predict whether gastrocnemius medialis contractile behavior during running on Moon will basically be the same as on Mars. Therefore, this study investigated lower limb joint kinematics and gastrocnemius medialis behavior during running at 1 g, simulated Martian gravity, and simulated Lunar gravity on the vertical treadmill facility. The results indicate that hypogravity-induced alterations in joint kinematics and contractile behavior still persist between simulated running on the Moon and Mars. This contrasts with the concept of a ceiling effect and should be carefully considered when evaluating exercise prescriptions and the transferability of locomotion practiced in Lunar gravity to Martian gravity.
- Open Access
- 9 August 2021
- Published by Springer Nature in npj Microgravity
- Vol. 7 (1) , 1-8
Contractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity
Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle−series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.
- 9 August 2021
- Published by Springer Nature in npj Microgravity
- Vol. 7 (1) , 1-8
Open AccessContractile behavior of the gastrocnemius medialis muscle during running in simulated hypogravity
Vigorous exercise countermeasures in microgravity can largely attenuate muscular degeneration, albeit the extent of applied loading is key for the extent of muscle wasting. Running on the International Space Station is usually performed with maximum loads of 70% body weight (0.7 g). However, it has not been investigated how the reduced musculoskeletal loading affects muscle and series elastic element dynamics, and thereby force and power generation. Therefore, this study examined the effects of running on the vertical treadmill facility, a ground-based analog, at simulated 0.7 g on gastrocnemius medialis contractile behavior. The results reveal that fascicle−series elastic element behavior differs between simulated hypogravity and 1 g running. Whilst shorter peak series elastic element lengths at simulated 0.7 g appear to be the result of lower muscular and gravitational forces acting on it, increased fascicle lengths and decreased velocities could not be anticipated, but may inform the development of optimized running training in hypogravity. However, whether the alterations in contractile behavior precipitate musculoskeletal degeneration warrants further study.
- Open Access
- 14 August 2020
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 120 (11) , 2407-2415
Head-down tilt bed rest with or without artificial gravity is not associated with motor unit remodeling
Purpose: The objective of this study was to assess whether artificial gravity attenuates any long-duration head-down 60 bed rest (HDBR)-induced alterations in motor unit (MU) properties. Methods: Twenty-four healthy participants (16 men; 8 women; 26–54 years) underwent 60-day HDBR with (n = 16) or without (n = 8) 30 min artificial gravity daily induced by whole-body centrifugation. Compound muscle action potential (CMAP), MU number (MUNIX) and MU size (MUSIX) were estimated using the method of Motor Unit Number Index in the Abductor digiti minimi and tibialis anterior muscles 5 days before (BDC-5), and during day 4 (HDT4) and 59 (HDT59) of HDBR. Results: The CMAP, MUNIX, and MUSIX at baseline did not change significantly in either muscle, irrespective of the intervention (p > 0.05). Across groups, there were no significant differences in any variable during HDBR, compared to BDC-5. Conclusion: Sixty days of HDBR with or without artificial gravity does not induce alterations in motor unit number and size in the ADM or TA muscles in healthy individuals.
- 14 August 2020
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 120 (11) , 2407-2415
Open AccessHead-down tilt bed rest with or without artificial gravity is not associated with motor unit remodeling
Purpose: The objective of this study was to assess whether artificial gravity attenuates any long-duration head-down 60 bed rest (HDBR)-induced alterations in motor unit (MU) properties. Methods: Twenty-four healthy participants (16 men; 8 women; 26–54 years) underwent 60-day HDBR with (n = 16) or without (n = 8) 30 min artificial gravity daily induced by whole-body centrifugation. Compound muscle action potential (CMAP), MU number (MUNIX) and MU size (MUSIX) were estimated using the method of Motor Unit Number Index in the Abductor digiti minimi and tibialis anterior muscles 5 days before (BDC-5), and during day 4 (HDT4) and 59 (HDT59) of HDBR. Results: The CMAP, MUNIX, and MUSIX at baseline did not change significantly in either muscle, irrespective of the intervention (p > 0.05). Across groups, there were no significant differences in any variable during HDBR, compared to BDC-5. Conclusion: Sixty days of HDBR with or without artificial gravity does not induce alterations in motor unit number and size in the ADM or TA muscles in healthy individuals.
- Open Access
- 13 February 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (2) , e0211263
Hopping in hypogravity—A rationale for a plyometric exercise countermeasure in planetary exploration missions
Moon and Mars are considered to be future targets for human space explorations. The gravity level on the Moon and Mars amount to 16% and 38%, respectively, of Earth’s gravity. Mechanical loading during the anticipated habitual activities in these hypogravity environments will most likely not be sufficient to maintain physiological integrity of astronauts unless additional exercise countermeasures are performed. Current microgravity exercise countermeasures appear to attenuate but not prevent ‘space deconditioning’. However, plyometric exercises (hopping and whole body vibration) have shown promise in recent analogue bed rest studies and may be options for space exploration missions where resources will be limited compared to the ISS. This paper therefore tests the hypothesis that plyometric hop exercise in hypogravity can generate sufficient mechanical stimuli to prevent musculoskeletal deconditioning. It has been suggested that hypogravity-induced reductions in peak ground reaction force (peak vertical GRF) can be offset by increases in hopping height. Therefore, this study investigated the effects of simulated hypogravity (0.16G, 0.27G, 0.38G, and 0.7G) upon sub-maximal plyometric hopping on the Verticalised Treadmill Facility, simulating different hypogravity levels. Results show that peak vertical GRF are negatively related to simulated gravity level, but positively to hopping height. Contact times decreased with increasing gravity level but were not influenced through hopping height. In contrast, flight time increased with decreasing gravity levels and increasing hopping height (P < 0.001). The present data suggest that the anticipated hypogravity-related reductions of musculoskeletal forces during normal walking can be compensated by performing hops and therefore support the idea of plyometric hopping as a robust and resourceful exercise countermeasure in hypogravity. As maximal hop height was constrained on the VTF further research is needed to determine whether similar relationships are evident during maximal hops and other forms of jumping.
- 13 February 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (2) , e0211263
Open AccessHopping in hypogravity—A rationale for a plyometric exercise countermeasure in planetary exploration missions
Moon and Mars are considered to be future targets for human space explorations. The gravity level on the Moon and Mars amount to 16% and 38%, respectively, of Earth’s gravity. Mechanical loading during the anticipated habitual activities in these hypogravity environments will most likely not be sufficient to maintain physiological integrity of astronauts unless additional exercise countermeasures are performed. Current microgravity exercise countermeasures appear to attenuate but not prevent ‘space deconditioning’. However, plyometric exercises (hopping and whole body vibration) have shown promise in recent analogue bed rest studies and may be options for space exploration missions where resources will be limited compared to the ISS. This paper therefore tests the hypothesis that plyometric hop exercise in hypogravity can generate sufficient mechanical stimuli to prevent musculoskeletal deconditioning. It has been suggested that hypogravity-induced reductions in peak ground reaction force (peak vertical GRF) can be offset by increases in hopping height. Therefore, this study investigated the effects of simulated hypogravity (0.16G, 0.27G, 0.38G, and 0.7G) upon sub-maximal plyometric hopping on the Verticalised Treadmill Facility, simulating different hypogravity levels. Results show that peak vertical GRF are negatively related to simulated gravity level, but positively to hopping height. Contact times decreased with increasing gravity level but were not influenced through hopping height. In contrast, flight time increased with decreasing gravity levels and increasing hopping height (P < 0.001). The present data suggest that the anticipated hypogravity-related reductions of musculoskeletal forces during normal walking can be compensated by performing hops and therefore support the idea of plyometric hopping as a robust and resourceful exercise countermeasure in hypogravity. As maximal hop height was constrained on the VTF further research is needed to determine whether similar relationships are evident during maximal hops and other forms of jumping.
- 14 May 2017
- Published by Wiley in The Journal of Physiology
- Vol. 595 (14) , 4589-4590
Altitude exposure and increased heart rate: the role of the parasympathetic nervous system
- 14 May 2017
- Published by Wiley in The Journal of Physiology
- Vol. 595 (14) , 4589-4590
Altitude exposure and increased heart rate: the role of the parasympathetic nervous system