David L. Dickensheets
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David L. Dickensheets has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Milind Rajadhyaksha
Dermatology Department, Memorial Sloan Kettering Cancer Center, New York, NY, 10022, USA
4 shared publications- Tianbo Liu
Electrical and Computer Engineering Department, Montana State University, Bozeman, MT, 59715, USA
4 shared publications - Gary Peterson
Memorial Sloan-Kettering Cancer Ctr. (United States)
3 shared publications Seth Kreitinger
Electrical and Computer Engineering Dept., Montana State University, Bozeman, MT 59717
3 shared publications- Jordan L. Baker
Montana State Univ, Elect & Comp Engn Dept, POB 173780, Bozeman, MT 59717 USA
2 shared publications Michael Heger
Electrical and Computer Engineering Department, Montana State University, Bozeman, Montana 59717, USA
2 shared publications
Latest Publications
- 15 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (8) , 15261-15279
Design and characterization of a bilayer wire-grid polarizer as a variable-angle polarizing beam splitter
Wire-grid polarizers (WGPs) are subwavelength metallic nanostructures that transmit one linear polarization state and reflect the orthogonal linear polarization state. Bilayer WGPs are devices composed of two sets of wire grids that are vertically offset by a surface-relief dielectric grating. We experimentally demonstrated a silicon-and-aluminum bilayer WGP for operation at wavelengths near 1550 nm that was optimized to be an angularly tolerant polarizing beam splitter (PBS)—to have high efficiency in the transmitted beam and in the orthogonally polarized reflected beam over a wide range of incidence angles. While bilayer WGPs at this wavelength tend to be fabricated with lower-index dielectric materials for better transmission efficiency, using silicon allowed us to both leverage existing silicon processing techniques and to create a device that is compatible with future integration with other silicon-based optical systems. We fabricated two devices, both of which maintained greater than 58% transmittance and greater than 93% reflectance over incidence angles from -50° to +50° for the horizontal polarizer pass axis orientation. Additionally, these devices demonstrated good performance as high contrast transmissive WGPs over this same angular range, maintaining a contrast ratio greater than 1000:1 for the horizontal pass axis orientation. Furthermore, we determined that if the Fresnel reflection at the device substrate’s back interface were reduced or eliminated, the transmission efficiency of the bilayer WGP could be as high as 82% for the horizontal pass axis orientation for all measured incidence angles. This demonstrated the potential for a silicon-based bilayer WGP to be used as a high-efficiency, variable-angle PBS that is integration-compatible with other silicon systems.
- 15 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (8) , 15261-15279
Design and characterization of a bilayer wire-grid polarizer as a variable-angle polarizing beam splitter
Wire-grid polarizers (WGPs) are subwavelength metallic nanostructures that transmit one linear polarization state and reflect the orthogonal linear polarization state. Bilayer WGPs are devices composed of two sets of wire grids that are vertically offset by a surface-relief dielectric grating. We experimentally demonstrated a silicon-and-aluminum bilayer WGP for operation at wavelengths near 1550 nm that was optimized to be an angularly tolerant polarizing beam splitter (PBS)—to have high efficiency in the transmitted beam and in the orthogonally polarized reflected beam over a wide range of incidence angles. While bilayer WGPs at this wavelength tend to be fabricated with lower-index dielectric materials for better transmission efficiency, using silicon allowed us to both leverage existing silicon processing techniques and to create a device that is compatible with future integration with other silicon-based optical systems. We fabricated two devices, both of which maintained greater than 58% transmittance and greater than 93% reflectance over incidence angles from -50° to +50° for the horizontal polarizer pass axis orientation. Additionally, these devices demonstrated good performance as high contrast transmissive WGPs over this same angular range, maintaining a contrast ratio greater than 1000:1 for the horizontal pass axis orientation. Furthermore, we determined that if the Fresnel reflection at the device substrate’s back interface were reduced or eliminated, the transmission efficiency of the bilayer WGP could be as high as 82% for the horizontal pass axis orientation for all measured incidence angles. This demonstrated the potential for a silicon-based bilayer WGP to be used as a high-efficiency, variable-angle PBS that is integration-compatible with other silicon systems.
- 24 April 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (13) , 3655-3663
Dynamic focusing using a MEMS mirror in a coherent lidar
This paper describes the use of dynamic focus control in a coherent lidar and compares the theoretical and experimental results. The system uses a MEMS variable-focus mirror, which has an electrostatically driven deformable membrane with a diameter of 4 mm and a manufacturer’s published 10%-to-90% rise time of less than 200 µs. The device permits fast, intra-scan adjustment of the downrange beam focus from 2.2 m to infinity for a lidar with a 25 mm diameter exit pupil. Experimentally, the variable-focus mirror improved the signal strength by more than 20 dB for objects within the first Rayleigh distance, in good agreement with theory. The fast response time allows the system to dynamically adjust the focus to different distances within a single sweep of a raster scan, in order to match the system focus on-the-fly to targets at different distances. Three-dimensional point clouds show that this technique allows some targets that are below the noise level when using a fixed focus to become visible when the focus is changed dynamically.
- 24 April 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (13) , 3655-3663
Dynamic focusing using a MEMS mirror in a coherent lidar
This paper describes the use of dynamic focus control in a coherent lidar and compares the theoretical and experimental results. The system uses a MEMS variable-focus mirror, which has an electrostatically driven deformable membrane with a diameter of 4 mm and a manufacturer’s published 10%-to-90% rise time of less than 200 µs. The device permits fast, intra-scan adjustment of the downrange beam focus from 2.2 m to infinity for a lidar with a 25 mm diameter exit pupil. Experimentally, the variable-focus mirror improved the signal strength by more than 20 dB for objects within the first Rayleigh distance, in good agreement with theory. The fast response time allows the system to dynamically adjust the focus to different distances within a single sweep of a raster scan, in order to match the system focus on-the-fly to targets at different distances. Three-dimensional point clouds show that this technique allows some targets that are below the noise level when using a fixed focus to become visible when the focus is changed dynamically.
- 8 February 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (5) , 1429-1437
Demonstration of a compact double-reflection transmissive beam scanner operating at 1550 nm wavelength
A compact forward-directed transmissive beam scanner operating at a wavelength of 1550 nm was constructed and characterized. The scanner consists of two wire-grid polarizers (WGPs) surrounding a 45° Faraday rotator, causing incident light to reflect once from each WGP before transmitting through the second polarizer. Scanning is achieved by tilting one of the WGPs. Measured efficiency remained above 73% over a 90° forward scan range (−45∘ to +45∘) for vertically polarized incident light. Additionally, we measured the efficiency versus beam deflection for four different incident linear polarization configurations, three of which maintained >70% efficiency for deflection angles up to −60∘.
- 8 February 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (5) , 1429-1437
Demonstration of a compact double-reflection transmissive beam scanner operating at 1550 nm wavelength
A compact forward-directed transmissive beam scanner operating at a wavelength of 1550 nm was constructed and characterized. The scanner consists of two wire-grid polarizers (WGPs) surrounding a 45° Faraday rotator, causing incident light to reflect once from each WGP before transmitting through the second polarizer. Scanning is achieved by tilting one of the WGPs. Measured efficiency remained above 73% over a 90° forward scan range (−45∘ to +45∘) for vertically polarized incident light. Additionally, we measured the efficiency versus beam deflection for four different incident linear polarization configurations, three of which maintained >70% efficiency for deflection angles up to −60∘.
- 1 June 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (17) , 4496-4504
Sequential RGB color imaging with a millimeter-scale monochrome camera with a rolling shutter
Applications are growing for ultracompact millimeter-scale cameras. For color images, these sensors commonly utilize a Bayer mask, which can negatively and perceptibly have an impact on image resolution and quality, especially for low pixel-count submillimeter sensors. To alleviate this, we built a time-multiplexed RGB LED illumination system synchronized to the rolling shutter of a monochrome camera. The sequential images are processed and displayed as near real-time color video. Experimental comparison with an identical sensor with a Bayer color mask showed significant improvement in the MTF curves and to perceived image clarity. Trade-offs with respect to system complexity and color motion artifacts are discussed.
- 1 June 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (17) , 4496-4504
Sequential RGB color imaging with a millimeter-scale monochrome camera with a rolling shutter
Applications are growing for ultracompact millimeter-scale cameras. For color images, these sensors commonly utilize a Bayer mask, which can negatively and perceptibly have an impact on image resolution and quality, especially for low pixel-count submillimeter sensors. To alleviate this, we built a time-multiplexed RGB LED illumination system synchronized to the rolling shutter of a monochrome camera. The sequential images are processed and displayed as near real-time color video. Experimental comparison with an identical sensor with a Bayer color mask showed significant improvement in the MTF curves and to perceived image clarity. Trade-offs with respect to system complexity and color motion artifacts are discussed.
- Open Access
- 26 June 2019
- Published by Springer Nature in Light: Science & Applications
- Vol. 8 (1) , 1-11
MEMS-in-the-lens architecture for a miniature high-NA laser scanning microscope
Laser scanning microscopes can be miniaturized for in vivo imaging by substituting optical microelectromechanical system (MEMS) devices in place of larger components. The emergence of multifunctional active optical devices can support further miniaturization beyond direct component replacement because those active devices enable diffraction-limited performance using simpler optical system designs. In this paper, we propose a catadioptric microscope objective lens that features an integrated MEMS device for performing biaxial scanning, axial focus adjustment, and control of spherical aberration. The MEMS-in-the-lens architecture incorporates a reflective MEMS scanner between a low-numerical-aperture back lens group and an aplanatic hyperhemisphere front refractive element to support high-numerical-aperture imaging. We implemented this new optical system using a recently developed hybrid polymer/silicon MEMS three-dimensional scan mirror that features an annular aperture that allows it to be coaxially aligned within the objective lens without the need for a beam splitter. The optical performance of the active catadioptric system is simulated and imaging of hard targets and human cheek cells is demonstrated with a confocal microscope that is based on the new objective lens design.
- 26 June 2019
- Published by Springer Nature in Light: Science & Applications
- Vol. 8 (1) , 1-11
Open AccessMEMS-in-the-lens architecture for a miniature high-NA laser scanning microscope
Laser scanning microscopes can be miniaturized for in vivo imaging by substituting optical microelectromechanical system (MEMS) devices in place of larger components. The emergence of multifunctional active optical devices can support further miniaturization beyond direct component replacement because those active devices enable diffraction-limited performance using simpler optical system designs. In this paper, we propose a catadioptric microscope objective lens that features an integrated MEMS device for performing biaxial scanning, axial focus adjustment, and control of spherical aberration. The MEMS-in-the-lens architecture incorporates a reflective MEMS scanner between a low-numerical-aperture back lens group and an aplanatic hyperhemisphere front refractive element to support high-numerical-aperture imaging. We implemented this new optical system using a recently developed hybrid polymer/silicon MEMS three-dimensional scan mirror that features an annular aperture that allows it to be coaxially aligned within the objective lens without the need for a beam splitter. The optical performance of the active catadioptric system is simulated and imaging of hard targets and human cheek cells is demonstrated with a confocal microscope that is based on the new objective lens design.
- Open Access
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 10931, 35-244
MEMS-in-the-lens 3D beam scanner for in vivo microscopy
The “MEMS-in-the-lens” active lens for a laser scanning microscope comprises a high numerical aperture front element, a 3D+ MOEMS beam scanner and a collimating back lens. The scanner utilizes a silicon gimbal with SU-8 polymer flexures and deformable membrane mirror. The mirror aperture is 4 mm in diameter, and is capable of 9 μm deflection for focus control, with four annular electrodes to allow tuning of primary and secondary spherical aberration. The gimbal supports tip/tilt actuation up to ±3° for lateral beam scanning. We show confocal imaging using a benchtop mockup of the active lens, illustrating the potential for this approach to support 3D microscopy for optical biopsy applications.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng in Proceedings of SPIE
- Vol. 10931, 35-244
Open AccessMEMS-in-the-lens 3D beam scanner for in vivo microscopy
The “MEMS-in-the-lens” active lens for a laser scanning microscope comprises a high numerical aperture front element, a 3D+ MOEMS beam scanner and a collimating back lens. The scanner utilizes a silicon gimbal with SU-8 polymer flexures and deformable membrane mirror. The mirror aperture is 4 mm in diameter, and is capable of 9 μm deflection for focus control, with four annular electrodes to allow tuning of primary and secondary spherical aberration. The gimbal supports tip/tilt actuation up to ±3° for lateral beam scanning. We show confocal imaging using a benchtop mockup of the active lens, illustrating the potential for this approach to support 3D microscopy for optical biopsy applications.
- 20 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (4) , 719-729
MEMS 3-D Scan Mirror With SU-8 Membrane and Flexures for High NA Microscopy
We demonstrate a micro-electro-mechanical systems (MEMS) beam scanner capable of biaxial scanning with simultaneous focus control, for integration into a handheld confocal microscope for skin imaging. The device is based on a dual-axis gimbal structure with an integrated large-stroke deformable mirror. SU-8 polymer is used to construct both the deformable membrane as well as the torsional hinges for biaxial scanning. The 4-mm-diameter mirror can perform raster pattern scanning with a range of +/-1.5° and Lissajous scanning with a range of +/-3° (mechanical scan angle), and has a maximum deflection of 9 μm for focus control. The design, fabrication, and characterization of the opto-mechanical performance of the MEMS device are presented in this paper.
- 20 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 27 (4) , 719-729
MEMS 3-D Scan Mirror With SU-8 Membrane and Flexures for High NA Microscopy
We demonstrate a micro-electro-mechanical systems (MEMS) beam scanner capable of biaxial scanning with simultaneous focus control, for integration into a handheld confocal microscope for skin imaging. The device is based on a dual-axis gimbal structure with an integrated large-stroke deformable mirror. SU-8 polymer is used to construct both the deformable membrane as well as the torsional hinges for biaxial scanning. The 4-mm-diameter mirror can perform raster pattern scanning with a range of +/-1.5° and Lissajous scanning with a range of +/-3° (mechanical scan angle), and has a maximum deflection of 9 μm for focus control. The design, fabrication, and characterization of the opto-mechanical performance of the MEMS device are presented in this paper.
- 1 January 2018
- Published by Optica Publishing Group
- p. MW4A.1
Toward Smaller, More Useable Clinical Confocal Microscopes with Advanced Scanning and Integrated Wide-Field Guidance
MEMS 3D scanning dramatically shrinks an instrument while preserving image quality, enabling pencil probes or endoscopic tools with the performance of benchtop instruments. An integrated wide-field camera provides real-time dermoscopic guidance during confocal sampling.
- 1 January 2018
- Published by Optica Publishing Group
- p. MW4A.1
Toward Smaller, More Useable Clinical Confocal Microscopes with Advanced Scanning and Integrated Wide-Field Guidance
MEMS 3D scanning dramatically shrinks an instrument while preserving image quality, enabling pencil probes or endoscopic tools with the performance of benchtop instruments. An integrated wide-field camera provides real-time dermoscopic guidance during confocal sampling.
- Open Access
- 21 March 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (7) , 1241-1244
Wide-field imaging combined with confocal microscopy using a miniature f/5 camera integrated within a high NA objective lens
Wide-field (WF) imaging paired with reflectance confocal microscopy can noninvasively detect skin cancer with high accuracy. However, two separate devices are required to perform each imaging procedure. We describe a new concept that integrates the two into one device: a miniature WF color camera within the objective lens used for confocal microscopy, providing simultaneous sub-surface cellular imaging and WF surface morphologic imaging. The camera, inserted between a hyperhemisphere front lens and a back lens group of the objective, commands a field of view of 4.0 mm, with a resolution better than 30 μm, while confocal optical sectioning is preserved at sharper than 2.5 μm.
- 21 March 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (7) , 1241-1244
Open AccessWide-field imaging combined with confocal microscopy using a miniature f/5 camera integrated within a high NA objective lens
Wide-field (WF) imaging paired with reflectance confocal microscopy can noninvasively detect skin cancer with high accuracy. However, two separate devices are required to perform each imaging procedure. We describe a new concept that integrates the two into one device: a miniature WF color camera within the objective lens used for confocal microscopy, providing simultaneous sub-surface cellular imaging and WF surface morphologic imaging. The camera, inserted between a hyperhemisphere front lens and a back lens group of the objective, commands a field of view of 4.0 mm, with a resolution better than 30 μm, while confocal optical sectioning is preserved at sharper than 2.5 μm.
- 29 February 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9689, 96890U
Dermoscopy-guided reflectance confocal microscopy of skin using high-NA objective lens with integrated wide-field color camera
Reflectance Confocal Microscopy, or RCM, is being increasingly used to guide diagnosis of skin lesions. The combination of widefield dermoscopy (WFD) with RCM is highly sensitive (~90%) and specific (~ 90%) for noninvasively detecting melanocytic and non-melanocytic skin lesions. The combined WFD and RCM approach is being implemented on patients to triage lesions into benign (with no biopsy) versus suspicious (followed by biopsy and pathology). Currently, however, WFD and RCM imaging are performed with separate instruments, while using an adhesive ring attached to the skin to sequentially image the same region and co-register the images. The latest small handheld RCM instruments offer no provision yet for a co-registered wide-field image. This paper describes an innovative solution that integrates an ultra-miniature dermoscopy camera into the RCM objective lens, providing simultaneous wide-field color images of the skin surface and RCM images of the subsurface cellular structure. The objective lens (0.9 NA) includes a hyperhemisphere lens and an ultra-miniature CMOS color camera, commanding a 4 mm wide dermoscopy view of the skin surface. The camera obscures the central portion of the aperture of the objective lens, but the resulting annular aperture provides excellent RCM optical sectioning and resolution. Preliminary testing on healthy volunteers showed the feasibility of combined WFD and RCM imaging to concurrently show the skin surface in wide-field and the underlying microscopic cellular-level detail. The paper describes this unique integrated dermoscopic WFD/RCM lens, and shows representative images. The potential for dermoscopy-guided RCM for skin cancer diagnosis is discussed.
- 29 February 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9689, 96890U
Dermoscopy-guided reflectance confocal microscopy of skin using high-NA objective lens with integrated wide-field color camera
Reflectance Confocal Microscopy, or RCM, is being increasingly used to guide diagnosis of skin lesions. The combination of widefield dermoscopy (WFD) with RCM is highly sensitive (~90%) and specific (~ 90%) for noninvasively detecting melanocytic and non-melanocytic skin lesions. The combined WFD and RCM approach is being implemented on patients to triage lesions into benign (with no biopsy) versus suspicious (followed by biopsy and pathology). Currently, however, WFD and RCM imaging are performed with separate instruments, while using an adhesive ring attached to the skin to sequentially image the same region and co-register the images. The latest small handheld RCM instruments offer no provision yet for a co-registered wide-field image. This paper describes an innovative solution that integrates an ultra-miniature dermoscopy camera into the RCM objective lens, providing simultaneous wide-field color images of the skin surface and RCM images of the subsurface cellular structure. The objective lens (0.9 NA) includes a hyperhemisphere lens and an ultra-miniature CMOS color camera, commanding a 4 mm wide dermoscopy view of the skin surface. The camera obscures the central portion of the aperture of the objective lens, but the resulting annular aperture provides excellent RCM optical sectioning and resolution. Preliminary testing on healthy volunteers showed the feasibility of combined WFD and RCM imaging to concurrently show the skin surface in wide-field and the underlying microscopic cellular-level detail. The paper describes this unique integrated dermoscopic WFD/RCM lens, and shows representative images. The potential for dermoscopy-guided RCM for skin cancer diagnosis is discussed.