Masoud Moradian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masoud Moradian has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Shekarchi
University of Tehran
7 shared publications M. Tyler Ley
4 shared publications- Farhad Pargar
Department of Civil Engineering, University of British Columbia, Vancouver, Canada
2 shared publications Mahdi Valipour
2 shared publicationsMehdi Nemati Chari
2 shared publicationsMilad Hallaji
2 shared publications
Latest Publications
- 1 April 2019
- Published by Elsevier in Cement and Concrete Composites
- Vol. 98, 150-161
Investigation of concrete workability through characterization of aggregate gradation in hardened concrete using X-ray computed tomography
- 1 April 2019
- Published by Elsevier in Cement and Concrete Composites
- Vol. 98, 150-161
Investigation of concrete workability through characterization of aggregate gradation in hardened concrete using X-ray computed tomography
- 1 November 2018
- Published by Elsevier in Materials & Design
- Vol. 157, 314-325
Stress induced dissolution and time-dependent deformation of portland cement paste
- 1 November 2018
- Published by Elsevier in Materials & Design
- Vol. 157, 314-325
Stress induced dissolution and time-dependent deformation of portland cement paste
- 1 January 2018
- Published by ASTM International in Advances in Civil Engineering Materials
- Vol. 7 (1) , 291-307
Dissolution and Leaching of Fly Ash in Nitric Acid Using Automated Scanning Electron Microscopy
This article studies the physical and chemical changes in two Class F fly ashes exposed to 3 % HNO3 solution for 15 min. Automated scanning electron microscopy was used to simultaneously determine the physical and chemical properties of thousands of individual particles before and after being exposed to the solution., Exposure for 15 min in the HNO3 solution resulted in the selective dissolution of particles containing over 30 % CaO content but did not cause significant physical or chemical changes in other particles for both fly ashes. In addition, the leaching of sulfur was observed from all particles. Two possible mechanisms are discussed. This work reveals that fly ash particle dissolution is not homogenous and is dependent on the chemical consistency of the particle. This work provides new insights into fly ash dissolution in aqueous solutions and characterization.
- 1 January 2018
- Published by ASTM International in Advances in Civil Engineering Materials
- Vol. 7 (1) , 291-307
Dissolution and Leaching of Fly Ash in Nitric Acid Using Automated Scanning Electron Microscopy
This article studies the physical and chemical changes in two Class F fly ashes exposed to 3 % HNO3 solution for 15 min. Automated scanning electron microscopy was used to simultaneously determine the physical and chemical properties of thousands of individual particles before and after being exposed to the solution., Exposure for 15 min in the HNO3 solution resulted in the selective dissolution of particles containing over 30 % CaO content but did not cause significant physical or chemical changes in other particles for both fly ashes. In addition, the leaching of sulfur was observed from all particles. Two possible mechanisms are discussed. This work reveals that fly ash particle dissolution is not homogenous and is dependent on the chemical consistency of the particle. This work provides new insights into fly ash dissolution in aqueous solutions and characterization.
- 1 December 2017
- Published by Elsevier in Materials & Design
- Vol. 136, 137-149
Direct observation of void evolution during cement hydration
- 1 December 2017
- Published by Elsevier in Materials & Design
- Vol. 136, 137-149
Direct observation of void evolution during cement hydration
- 25 September 2016
- Published by Techno-Press in Computers & concrete
- Vol. 18 (3) , 367-388
A simple practical method for determination of moisture transfer coefficient of mature concrete using a combined experimental-numerical approach
- 25 September 2016
- Published by Techno-Press in Computers & concrete
- Vol. 18 (3) , 367-388
A simple practical method for determination of moisture transfer coefficient of mature concrete using a combined experimental-numerical approach
- 1 January 2015
- Published by American Concrete Institute in ACI Materials Journal
- Vol. 112 (1)
Behavior of Steel Fiber-Reinforced Cementitious Mortar and High-Performance Concrete in Triaxial Loading
- 1 January 2015
- Published by American Concrete Institute in ACI Materials Journal
- Vol. 112 (1)
Behavior of Steel Fiber-Reinforced Cementitious Mortar and High-Performance Concrete in Triaxial Loading
- 1 October 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 27 (5) , 519-528
Corrosion Assessment of RC Deck in a Jetty Structure Damaged by Chloride Attack
The long-term behavior of concrete structures has shown that their main cause of distress is reinforcement corrosion. One of the most punishing exposure conditions for concrete is a marine environment such as that found in the Persian Gulf. Reinforcement corrosion from diffusion of chloride ions is the main mechanism for deterioration under such conditions; it is found that chloride penetration and chloride-induced reinforcement corrosion rates can be very high, often leading to a reduced service life. This paper presents results of a study performed on a 40-year-old RC jetty structure in the Mahshahr Petrochemical Special Zone, Persian Gulf region that had suffered extensive deterioration from chloride-induced corrosion. Based on visual inspection as well as in situ and laboratory tests, it was strongly evident that the structure had not been designed and built under sufficient qualitative specifications.
- 1 October 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 27 (5) , 519-528
Corrosion Assessment of RC Deck in a Jetty Structure Damaged by Chloride Attack
The long-term behavior of concrete structures has shown that their main cause of distress is reinforcement corrosion. One of the most punishing exposure conditions for concrete is a marine environment such as that found in the Persian Gulf. Reinforcement corrosion from diffusion of chloride ions is the main mechanism for deterioration under such conditions; it is found that chloride penetration and chloride-induced reinforcement corrosion rates can be very high, often leading to a reduced service life. This paper presents results of a study performed on a 40-year-old RC jetty structure in the Mahshahr Petrochemical Special Zone, Persian Gulf region that had suffered extensive deterioration from chloride-induced corrosion. Based on visual inspection as well as in situ and laboratory tests, it was strongly evident that the structure had not been designed and built under sufficient qualitative specifications.
- 1 October 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 26 (5) , 633-643
Assessment of Long-Term Performance of a 50-Year-Old Jetty in the South of Iran
A detailed investigation was carried out on a 50-year-old reinforced concrete jetty in a commercial port of Iran to assess the long-term performance as well as the structural condition. Destructive and nondestructive tests such as carbonation depth, electrical resistivity, chloride diffusion, X-ray diffraction, compressive strength, and water absorption were performed. The results revealed that the good quality of the concrete has protected reinforcement from corrosion. However, structural analysis showed minor weakness in some elements of the jetty; thus, consulting engineers finally decided to strengthen some elements with fiber-reinforced polymers.
- 1 October 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 26 (5) , 633-643
Assessment of Long-Term Performance of a 50-Year-Old Jetty in the South of Iran
A detailed investigation was carried out on a 50-year-old reinforced concrete jetty in a commercial port of Iran to assess the long-term performance as well as the structural condition. Destructive and nondestructive tests such as carbonation depth, electrical resistivity, chloride diffusion, X-ray diffraction, compressive strength, and water absorption were performed. The results revealed that the good quality of the concrete has protected reinforcement from corrosion. However, structural analysis showed minor weakness in some elements of the jetty; thus, consulting engineers finally decided to strengthen some elements with fiber-reinforced polymers.