YTYasutaka Tashiro

Yasutaka Tashiro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yasutaka Tashiro has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Yukihide Iwamoto

    Department of Orthopaedic Surgery, Kyushu University, Fukuoka 812-8582, Japan

    8 shared publications
  • Ken Okazaki

    Department of Orthopaedic Surgery, Tokyo Women’s Medical University, Tokyo, Japan

    6 shared publications
  • Kanji Osaki

    Department of Orthopaedic Surgery, Kyushu University, Fukuoka 812-8582, Japan

    4 shared publications
  • Hirokazu Matsubara

    Department of Orthopaedic Surgery, Kyushu University, Fukuoka 812-8582, Japan

    3 shared publications
  • Satoshi Hamai

    Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan

    3 shared publications
  • Hideki Mizu-Uchi

    Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan

    2 shared publications

Latest Publications

  • Open Access

    Comparison of the efficacy and safety of acetaminophen versus NSAIDs for the treatment of chronic pain in older adults with osteoarthritis of the hip and knee: Findings from the randomized, double-blind, parallel-group, non-inferiority RETHINK study

    by Makoto Endo, Tsutomu Kawano, Masami Tokunaga, Shinya Kawahara, Taro Mawatari, Toshihiko Hara, Yasutaka Tashiro, Masahiro Matsuda, Taishi Sato, Shoji Baba, et al.

  • Open Access

    Anterolateral rotatory instability in vivo correlates tunnel position after anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft

    by Yasutaka Tashiro, Ken Okazaki, Koji Murakami, Hirokazu Matsubara, Kanji Osaki, Yukihide Iwamoto, Yasuharu Nakashima

    Anterolateral rotatory instability in vivo correlates tunnel position after anterior cruciate ligament reconstruction using bone-patellar tendon-bone graft


  • Anterior cruciate ligament tibial insertion site is elliptical or triangular shaped in healthy young adults: high-resolution 3-T MRI analysis

    by Yasutaka Tashiro, Gian Andrea Lucidi, Tom Gale, Kanto Nagai, Elmar Herbst, James J. Irrgang, Yasuharu Nakashima, William Anderst, Freddie H. Fu

    Purpose To clarify the morphology of anterior cruciate ligament (ACL) tibial insertion site in healthy young knees using high-resolution 3-T MRI. Methods Subjects were 50 ACL-reconstructed patients with a mean age of 21.4 ± 6.8 years. The contralateral healthy knees were scanned using high-resolution 3-T MRI. The tibial insertion sites of the anteromedial (AM) and posterolateral (PL) bundle fibres, and the ACL attachment on the anterior horn of lateral meniscus (AHLM) were segmented from the MR images, and 3D models were reconstructed to evaluate the morphology. The shape of ACL footprint was qualitatively analysed, and the size of AM and PL attachments and AHLM overlapped area was measured digitally. Results Tibial AM and PL bundles were clearly identified in 42 of 50 knees (84.0%). Morphology of the whole ACL tibial insertion site was elliptical in 23 knees (54.8%) and triangular in 19 knees (45.2%), but not classified as C-shape in any knees. However, the AM bundle attachment was of C-shape in 29 knees (69.0%) and band-like in 13 knees (31.0%). Overlap of ACL on AHLM was found in 26 knees (61.9%), and the size of the overlapped area was 4.8 ± 4.7% of the whole ACL insertion site. Conclusion 3D morphology of the intact ACL tibial insertion site analysed by high-resolution 3-T MRI was elliptical or triangular in healthy young knees. However, the AM bundle insertion site was of C-shape or band-like. A small lateral portion of the ACL was overlapped with the AHLM. As for clinical relevance, these findings should be considered in order to reproduce the native ACL insertion site sufficiently. Level of evidence III.


  • Comparison of graft bending angle during knee motion after outside-in, trans-portal and trans-tibial anterior cruciate ligament reconstruction

    by Yasutaka Tashiro, Sebastián Irarrázaval, Kanji Osaki, Yukihide Iwamoto, Freddie H. Fu

    Purpose To determine graft bending angle (GBA) during knee motion after anatomic anterior cruciate ligament (ACL) reconstruction and to clarify whether surgical techniques affect GBA. Our hypotheses were that the graft bending angle would be highest at knee extension and the difference of surgical techniques would affect the bending steepness. Methods Eight healthy volunteers with a mean age of 29.3 ± 3.0 years were recruited and 3D MRI knee models were created at three flexion angles (0°, 90° and 130°). Surgical simulation of the tunnel drilling was performed with anatomic tunnel position using each outside-in (OI), trans-portal (TP) and trans-tibial (TT) techniques on the identical cases. The models were matched to other knee positions and the GBA in 3D was measured using computational software. Double-bundle ACL reconstruction was analysed first, and single-bundle reconstruction was also analysed to evaluate its effect to reduce GBA. A repeated-measures ANOVA was used to compare GBA difference at three flexion angles, by three techniques or of three bundles. Results GBA changed substantially with knee motion, and it was highest at full extension (p < 0.001) in each surgical technique. OI technique exhibited highest GBA for anteromedial bundle (94.3° ± 5.2°) at extension, followed by TP (83.1° ± 6.5°) and TT (70.0° ± 5.2°) techniques (p < 0.01). GBA for posterolateral bundle at extension were also high in OI (84.6° ± 7.4°), TP (83.0° ± 6.3°) and TT (77.2° ± 7.0°) techniques (n.s.). Single-bundle grafts did not decrease GBA compared with double-bundle grafts. In OI technique, a more proximal location of the femoral exit reduced GBA of each bundle at extension and 90° flexion. Conclusion A significant GBA change with knee motion and considerably steep bending at full extension, especially with OI and TP techniques, were simulated. Although single-bundle technique did not reduce GBA as seen in double-bundle technique, proximal location of femoral exits by OI technique, with tunnels kept in anatomic position, was effective in decreasing GBA at knee extension and flexion. For clinical relevance, high stress on graft and bone interface has been suggested by steep GBA at full extension after anatomic ACL reconstruction. Level of evidence Therapeutic study (prospective comparative study), Level II.


  • Comparison of the impact of closing wedge versus opening wedge high tibial osteotomy on proximal tibial deformity and subsequent revision to total knee arthroplasty

    by Umito Kuwashima, Yasutaka Tashiro, Ken Okazaki, Hideki Mizu-Uchi, Satoshi Hamai, Koji Murakami, Yukihide Iwamoto

    The purpose of this study was to assess the differences in proximal tibial deformity between closing wedge (CW) and opening wedge (OW) high tibial osteotomy (HTO) and their effects on the difficulty of total knee arthroplasty (TKA) conversion. Surgical simulations of CW-HTO and OW-HTO were performed on the same 3D computer-aided design knee models reconstructed from computed tomographic datasets of patients (median age 77 years; range 55–87 years; 40 knees) with medial osteoarthritis or osteonecrosis, and proximal tibial deformities were analysed. Subsequent TKA conversion was simulated in both CW and OW models, and the interference between the tibial implant and endosteal cortex was assessed. The difference in the metaphyseal–diaphyseal angle in the CW-HTO and OW-HTO groups was 0.3° ± 0.2° (p < 0.001). The mechanical axis in the CW-HTO group was shifted laterally by 1.8 ± 1.1 mm relative to that in the OW-HTO group (p < 0.001) on the resection surface in TKA. Finally, the TKA tibial implant was substantially closer to the endosteal cortex in the CW-HTO group (mean 5.6 ± 1.6 mm) than to that in the OW-HTO group (mean 7.3 ± 1.6 mm) (p < 0.001). The difference in the post-operative angular deformities of the proximal tibia between CW-HTO and OW-HTO was considered to be clinically irrelevant. The risk of interference between TKA tibial implant and endosteal bone was greater after CW-HTO than after OW-HTO. For clinical relevance, the difference between the two techniques has little influence on subsequent TKA difficulty regarding the proximal tibial deformity, although preoperative planning is obligatory, particularly after CW-HTO, to prevent interference with the tibial implant. II.


  • Open Access

    Evaluating the distance between the femoral tunnel centers in anatomic double-bundle anterior cruciate ligament reconstruction using a computer simulation

    by Yasutaka Tashiro, Ken Okazaki, Yukihide Iwamoto

    Purpose: We aimed to clarify the distance between the anteromedial (AM) bundle and posterolateral (PL) bundle tunnel-aperture centers by simulating the anatomical femoral tunnel placement during double-bundle anterior cruciate ligament reconstruction using 3-D computer-aided design models of the knee, in order to discuss the risk of tunnel overlap. Relationships between the AM to PL center distance, body height, and sex difference were also analyzed. Patients and methods: The positions of the AM and PL tunnel centers were defined based on previous studies using the quadrant method, and were superimposed anatomically onto the 3-D computer-aided design knee models from 68 intact femurs. The distance between the tunnel centers was measured using the 3-D DICOM software package. The correlation between the AM–PL distance and the subject's body height was assessed, and a cutoff height value for a higher risk of overlap of the AM and PL tunnel apertures was identified. Results: The distance between the AM and PL centers was 10.2±0.6 mm in males and 9.4±0.5 mm in females (Pr=0.66, Pr=0.63, P Conclusion: When AM and PL tunnels were placed anatomically in simulated double-bundle anterior cruciate ligament reconstruction, the distance between the two tunnel centers showed a strong positive correlation with body height. In cases with relatively short stature, the AM and PL tunnel apertures are considered to be at a higher risk of overlap when surgeons choose the double-bundle technique.


  • Optimal entry position on the lateral femoral surface for outside‐in drilling technique to restore the anatomical footprint of anterior cruciate ligament

    by Hirokazu Matsubara, Ken Okazaki, Kanji Osaki, Yasutaka Tashiro, Hideki Mizu‐Uchi, Satoshi Hamai, Yukihide Iwamoto

    Purpose: To investigate the optimal starting points for drilling on the lateral femoral condyle for better coverage of the anatomical footprint of the anterior cruciate ligament (ACL) using the outside‐in (OI) technique in a single‐bundle ACL reconstruction.Methods: Femoral tunnel drilling was simulated on three‐dimensional bone models from 40 subjects by connecting the centre of the ACL footprint with various points on the lateral femoral surface. The percentage of the femoral footprint covered by apertures of the virtual tunnel sockets with 9 mm diameter was calculated for each tunnel.Results: The mean percentages of the femoral footprint covered by the apertures of the virtual tunnel sockets were significantly higher when drilled at 2 and 3 cm from the lateral epicondyle on a 45° line and a 60° line anterior from the proximal–distal axis than the other points. However, articular cartilage damage was occurred in nine subjects at 3 cm on a 60° line and eight subjects at 3 cm on a 45° line. Posterior wall blowout occurred in five subjects at 3 cm on a 45° line. Thus, OI drilling at 3 cm from the epicondyle has a risk of these complications.Conclusion: During the OI drilling of the femoral tunnel, connecting the centre of the anatomical footprint of the ACL and the entry drilling point at 2 cm from the lateral epicondyle on between the 45° line and the 60° line anterior from the proximal–distal axis provides an oval‐shaped socket aperture that covers and restores the native ACL footprint as nearly as possible.Level of evidence: III.


  • The coronal alignment after medial unicompartmental knee arthroplasty can be predicted: usefulness of full‐length valgus stress radiography for evaluating correctability

    by Yasutaka Tashiro, Shuichi Matsuda, Ken Okazaki, Hideki Mizu‐Uchi, Umito Kuwashima, Yukihide Iwamoto

    Purpose: We aimed to clarify whether the coronal alignment after medial unicompartmental knee arthroplasty (UKA) is predictable using preoperative full‐length valgus stress radiography.Methods: Thirty‐seven consecutive patients with a mean age of 71.5 ± 7.0 years awaiting medial UKA were recruited. Full‐length weight‐bearing radiographs of the lower limbs were obtained pre‐ and postoperatively. Preoperative full‐length valgus stress radiography in the supine position was also performed, and the transition of the hip‐knee‐ankle angle (HKAA) and the weight‐bearing ratio were assessed. The tibia first cut technique was used, and the distal femur was cut parallel to the cutting surface of the proximal tibia during surgery.Results: The mean postoperative HKAA was 2.0° ± 2.1° varus, and the mean weight‐bearing ratio was 43.1 ± 7.7 %; each of these parameters demonstrated significantly strong correlations with the values on the preoperative valgus stress radiographs (p < 0.01), while the correlation between the postoperative alignment and the preoperative standing alignment without stress was moderate (p < 0.01). The postoperative alignment was slightly undercorrected compared to that observed on the valgus stress radiographs (p < 0.05), and no knees exhibited evident overcorrection compared to that on the valgus stress radiographs.Conclusion: Preoperative valgus stress radiography is useful for evaluating the correctability of varus deformities and predicting the postoperative coronal alignment. For clinical relevance, performing preoperative valgus stress radiography would help to more precisely select patients and, when combined with the tibia first cut technique, aid in achieving the expected knee alignment and avoid severe undercorrection or overcorrection.Level of evidence: Diagnostic study, Level II.


  • Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty

    by Ken Okazaki, Yasutaka Tashiro, Hideki Mizu-Uchi, Satoshi Hamai, Toshio Doi, Yukihide Iwamoto


  • Open Access

    Comparison of transtibial and transportal techniques in drilling femoral tunnels during anterior cruciate ligament reconstruction using 3D-CAD models

    by Yasutaka Tashiro, Ken Okazaki, Munenori Uemura, Kanji Osaki, Hirokazu Matsubara, Kazutaka Toyoda, Makoto Hashizume, Yukihide Iwamoto

    Purpose: The purpose of this study was to assess the differences in bone tunnel apertures between the trans-accessory medial portal (trans-AMP) technique and the transtibial (TT) technique in double-bundle anterior cruciate ligament reconstruction. The extent of ovalization and the frequency of overlap of the two tunnel apertures were compared. Methods: The simulation of femoral tunnel drilling with the TT and the trans-AMP techniques was performed using three-dimensional computer aided design models from two volunteers. The incidence angle of drilling against the intercondylar wall, the femoral tunnel position, the ovalization, and the overlap were analyzed. The aperture and location of the tunnels were also examined in real anterior cruciate ligament reconstruction cases (n=36). Results: The surgical simulation showed that a lower drill incident angle induced by the TT technique made the apertures of two tunnels more ovalized, located anteromedial tunnels in a shallower position to prevent posterior wall blow out, and led to a higher frequency of tunnel overlap. The trans-AMP group had tunnel places within the footprint and had less ovalization and overlap. The results of analysis for tunnels in the clinical cases were consistent with results from the surgical simulation. Conclusion: In the TT technique, the shallow anteromedial tunnel location and more ovalized tunnel aperture can lead to a higher frequency of tunnel overlap. Compared with the TT technique, the trans-AMP technique was more useful in preparing femoral tunnels anatomically and avoiding tunnel ovalization and overlapping in double-bundle anterior cruciate ligament reconstruction.