JVJuan Verde

Juan Verde

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juan Verde has a total of 113 co-authors. Here are the top co-authors by number of shared publications:

  • Alain García Vázquez

    IHU, Institute of Image-Guided Surgery, 1 Pl. de l’Hôpital, 67000 Strasbourg, France

    2 shared publications
  • Guido Costamagna

    Digestive Endoscopy Unit, Center for Endoscopic Research Therapeutics and Training (CERTT), Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy

    2 shared publications
  • Ivo Boškoski

    Digestive Endoscopy Unit, Center for Endoscopic Research Therapeutics and Training (CERTT), Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy

    2 shared publications
  • Jacques Marescaux

    Research Institute against Digestive Cancer, IRCAD, Strasbourg University, Strasbourg, France

    2 shared publications
  • Lee L. Swanstrom

    IHU-Strasbourg, Institute of Image guided Surgery, Strasbourg (France)

    2 shared publications
  • Mariano Palermo

    Daicim Foundation, Training, Research, and Clinical activity in Minimally Invasive Surgery, Buenos Aires, Argentina

    2 shared publications

Latest Publications

  • Open Access

    How artificial intelligence and human expertise will improve access to healthcare in the Global South

    by Saad Slimani, Sara Ajanovic, Mariam Aboian, Idriss Ahmedou, Udunna Anazodo, Sandrine de Ribaupierre, Hicham El Attar, Bassma El Sabaa, Rachel E. A. Fincham, Daniel A. Hashimoto, et al.

  • Open Access

    Exploring Endovascular Photo-Activated Ablation (EPA) for Downstaging Locally Advanced Pancreatic Cancer: A Proof-of-Concept Study in the Normal Porcine Model

    by Alain García Vázquez, Juan Manuel Verde, Fanélie Wanert, Irene Alexandra Spiridon, Axel Schmid, Tina Saeidi, Lee L. Swanstrom, Stephen G. Bown, Lothar Lilge, Arjen Bogaards

    Background: Pancreatic cancers can involve large blood vessels early, making complete resection technically challenging or impossible. A minimally invasive treatment that clears vessels from encasing tumours could potentially enable curative surgery. We hypothesise that Endovascular Photo-activated Ablation (EPA) of perivascular tumour tissue can create a necrotic zone free of viable tumour between cancer and blood vessels, through which the tumour could be resected. Methods: A dose escalation study was conducted in the normal porcine model (n = 7). Under general anaesthesia, the animals were given a photo-activated drug and photo-activation was provided by a prototype balloon catheter, positioned in a major blood vessel within the pancreas, under angiographic guidance. Contrast-enhanced CT scans were undertaken prior to and 1, 2, or 7 days following ablation. The animals were euthanised and the exposed tissue excised en bloc for histological examination. Results: Five animals were euthanised after 2 days. On post-mortem, the histology confirmed necrotic pancreas in the perivascular zone, which increased from zero to 15 mm around the treated vessel, for increasing drug doses. Treated arteries showed necrotising arteritis, without evidence of perforation or obstruction during the observation period, although one animal was euthanised at 1 day, due to technical endovascular device issues and obstruction. The lowest-dose animal euthanised at 7 days showed no lesions on pathology. Conclusions: These proof-of-concept results demonstrate that EPA can produce pancreatic perivascular necrosis in a large animal model. In a pancreatic cancer abutting a major blood vessel, this procedure may be able to create a zone free of viable tumour, potentially rendering these cancers operable, while preserving vessel integrity. These findings support further research activities towards clinical translation.

  • Domain agnostic 2D-3D deformable registration Application to fluoroscopic guidance without contrast agent

    by François Lecomte-Denis, Juan Verde, Jean-Louis Dillenseger, Stéphane Cotin


  • Towards Real-Time Intrahepatic Vessel Identification in Intraoperative Ultrasound-Guided Liver Surgery

    by Karl-Philippe Beaudet, Alexandros Karargyris, Sidaty El Hadramy, Stéphane Cotin, Jean-Paul Mazellier, Nicolas Padoy, Juan Verde


  • Cryotrack: Planning and Navigation for Computer Assisted Cryoablation

    by Henry J. Krumb, Jonas Mehtali, Juan Verde, Anirban Mukhopadhyay, Caroline Essert


  • Open Access

    Characterization of susceptibility artifacts in magnetic resonance thermometry images during laser interstitial thermal therapy: dimension analysis and temperature error estimation

    by Martina De Landro, Céline Giraudeau, Juan Verde, Khalid Ambarki, Sanzhar Korganbayev, Alexey Wolf, Henrik Odéen, Paola Saccomandi

    Objective. Laser interstitial thermal therapy (LITT) is a minimally invasive procedure used to treat a lesion through light irradiation and consequent temperature increase. Magnetic resonance thermometry imaging (MRTI) provides a multidimensional measurement of the temperature inside the target, thus enabling accurate monitoring of the damaged zone during the procedure. In proton resonance frequency shift-based thermometry, artifacts in the images may strongly interfere with the estimated temperature maps. In our work, after noticing the formation of the dipolar-behavior artifact linkable to magnetic susceptibility changes during in vivo LITT, an investigation of susceptibility artifacts in tissue-mimicking phantoms was implemented. Approach. The artifact was characterized: (i) by measuring the area and total volume of error regions and their evolution during the treatment; and (ii) by comparison with temperature reference provided by three temperature sensing needles. Lastly, a strategy to avoid artifacts formation was devised by using the temperature-sensing needles to implement a temperature-controlled LITT. Main results. The artifact appearance was associated with gas bubble formation and with unwanted treatment effects producing magnetic susceptibility changes when 2 W laser power was set. The analysis of the artifact’s dimension demonstrated that in the sagittal plane the dipolar-shape artifact may consistently spread following the temperature trend until reaching a volume 8 times bigger than the ablated one. Also, the artifact shape is quite symmetric with respect to the laser tip. An absolute temperature error showing a negative Gaussian profile in the area of susceptibility artifact with values up to 64.4 °C was estimated. Conversely, a maximum error of 2.8 °C is measured in the area not-affected by artifacts and far from the applicator tip. Finally, by regulating laser power, susceptibility artifacts formation was avoided, and appreciable thermal damage was induced. Significance. These findings may help in improving the MRTI-based guidance of thermal therapies.


  • Robotically assisted augmented reality system for identification of targeted lymph nodes in laparoscopic gynecological surgery: a first step toward the identification of sentinel node

    by Lise Lecointre, Juan Verde, Laurent Goffin, Aïna Venkatasamy, Barbara Seeliger, Massimo Lodi, Lee L. Swanström, Chérif Akladios, Benoît Gallix

    Background To prove feasibility of multimodal and temporal fusion of laparoscopic images with preoperative computed tomography scans for a real-time in vivo-targeted lymph node (TLN) detection during minimally invasive pelvic lymphadenectomy and to validate and enable such guidance for safe and accurate sentinel lymph node dissection, including anatomical landmarks in an experimental model. Methods A measurement campaign determined the most accurate tracking system (UR5-Cobot versus NDI Polaris). The subsequent interventions on two pigs consisted of an identification of artificial TLN and anatomical landmarks without and with augmented reality (AR) assistance. The AR overlay on target structures was quantitatively evaluated. The clinical relevance of our system was assessed via a questionnaire completed by experienced and trainee surgeons. Results An AR-based robotic assistance system that performed real-time multimodal and temporal fusion of laparoscopic images with preoperative medical images was developed and tested. It enabled the detection of TLN and their surrounding anatomical structures during pelvic lymphadenectomy. Accuracy of the CT overlay was > 90%, with overflow rates < 6%. When comparing AR to direct vision, we found that scores were significatively higher in AR for all target structures. AR aided both experienced surgeons and trainees, whether it was for TLN, ureter, or vessel identification. Conclusion This computer-assisted system was reliable, safe, and accurate, and the present achievements represent a first step toward a clinical study. Graphical abstract


  • Open Access

    Steering resilience in nursing practice: Examining the impact of digital innovations and enhanced emotional training on nurse competencies

    by Dieu Hack-Polay, Ali B. Mahmoud, Irene Ikafa, Mahfuzur Rahman, Maria Kordowicz, Juan Manuel Verde


  • Image-Guided Surgical Simulation in Minimally Invasive Liver Procedures: Development of a Liver Tumor Porcine Model Using a Multimodality Imaging Assessment

    by Alain García Vázquez, María Rita Rodríguez-Luna, Juan Verde, Etienne Piantanida, Giuseppe Alonci, Mariano Palermo, Edgardo Serra, Luisa De Cola, Mariano Eduardo Giménez

    Background: Image-guided liver surgery and interventions are growing as part of the current trend to translate liver procedures into minimally invasive approaches. Hands-on surgical training in such techniques is required. Consequently, a meaningful and realistic liver tumor model using multi-imaging modalities, such as ultrasound (US), computed tomography (CT), magnetic resonance (MR), cone beam-CT (CBCT), is mandatory. The first aim of this study is to develop a novel tumor-mimic model and assess it with multi-imaging modalities. The second aim is to evaluate the usefulness of the model during image-guided liver procedures. Materials and Methods: The tumor-mimic model is made of a composition of hydrogel, smashed muscle, and gadolinium contrast solution. Five ex vivo livers and three pigs were included in the study. Procedures were performed in an experimental hybrid operating room. Under general anesthesia, US guidance was required to inject the biotumor formula into the pig's liver. US, CT, CBCT, and MR acquisitions were then performed after the initial injection. In vivo models were then used to perform liver procedures, including US-guided biopsy, radiofrequency ablation, and laparoscopic resection. Results: The formula developed is easily injected generating a tissue-like material. Visualization using multi-imaging modalities was appropriate, thereby allowing to perform image-guided techniques. Conclusion: A novel design of an in vivo and ex vivo tissue-like tumor liver model is presented. Due to the multimodality imaging appraisal, it may provide a realistic and meaningful model allowing to perform image-guided liver procedures.


  • Percutaneous transhepatic cholangioscopy using a single-operator cholangioscope (pSOC), a retrospective, observational, multicenter study

    by Christian Gerges, Alain García Vázquez, Andrea Tringali, Juan Manuel Verde, Tobias Dertmann, Eduardo Houghton, Alessandro Cina, Torsten Beyna, Federico Sylvestre Begnis, Margherita Pizzicannella, et al.

    Background and aims Percutaneous cholangioscopy (PC) is more complex and invasive than a transpapillary approach, with the need for a large percutaneous tract of 16 French (Fr) on average in order to advance standard percutaneous cholangioscopes. The aim of this study was to investigate whether percutaneous single-operator cholangioscopy (pSOC) using the SpyGlass™ DS system is feasible, safe, and effective in PC for diagnostic and therapeutic indications. Materials and methods The data of 28 patients who underwent pSOC in 4 tertiary referral centers were retrospectively analyzed. Technical and clinical success for therapeutic procedures was assessed as well as diagnostic accuracy of pSOC-guided biopsies and visualization. Adverse events and the required number and size of dilatations were reviewed. Results 25/28 (89%) patients had a post-surgical altered anatomy. The average number of percutaneous dilatations prior to pSOC was 1.25 with a mean dilatation size of 11 French. Histopathology showed a 100% accuracy. Visual impression showed an overall accuracy of 96.4%. Technical and clinical success was achieved in 27/28 (96%) of cases. Adverse events occurred in 3/28 (10.7%) cases. Conclusion pSOC is a feasible, safe, and effective technique for diagnostic and therapeutic indications. It may be considered an alternative approach in clinical cases where gastrointestinal anatomy is altered. It has the potential to reduce peri-procedural adverse events and costs. Prospective randomized-controlled trials are necessary to confirm the previously collected data.